Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SANS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Integration of ultra-low coverage whole-genome sequences for reconstructing the evolutionary history of Galapagos giant tortoises

Genomic data from contemporary and historical samples often need to be coupled for evolutionary reconstructions of multitaxon complexes. However, the genetic data recovered from historical samples may result only in ultra-low coverage whole-genome sequences (ulcWGS; <0.15× depth), leading to inaccurate evolutionary inferences given a preponderance of missing data. Using the Galapagos giant tortoise radiation as a study system (Chelonoidis spp., composed of 13 extant and four extinct lineages), we assembled a novel methodological pipeline that removes potential noise introduced by the missing data and enhances the evolutionary signal from ulcWGS samples. We leveraged existing tools for phylogenomic placement (EPA-ng), population genomic structure (smartsnp) and admixture (Admixfrog, NGSadmix) to demonstrate that the evolutionary history of samples can be uncovered with sequencing depths as low as 0.008–0.139×. Importantly, these approaches do not use genotype imputation of the ulcWGS samples, which would require extensive reference datasets. Our application to two cases of extinct lineages of Galapagos giant tortoises, with and without references from the same lineage, demonstrates the general value of the approach. We confirm where the extinct lineages from San Cristóbal and Santa Fe islands fit into the Galapagos giant tortoise radiation, and that these lineages were evolutionarily distinct entities.

ancient DNA↗

Factors affecting the output pulse flatness of the linear transformer driver cavity systems with 5th harmonics

Here, we describe the study we have undertaken to evaluate the effect of component tolerances in obtaining a voltage output flat top for a linear transformer driver (LTD) cavity containing 3rd and 5th harmonic bricks [A. A. Kim et al., in Proc. IEEE Pulsed Power and Plasma Science PPPS2013 (San Francisco, California, USA, 2013), pp. 1354–1356.] and for 30 cavity voltage adder. Our goal was to define the necessary component value precision in order to obtain a voltage output flat top with no more than ±0.5% amplitude variation.

43 PARTICLE ACCELERATORS↗

Exploring the origins of the Dzyaloshinskii-Moriya interaction in MnSi

By using magnetization and small-angle neutron scattering (SANS) measurements, we have investigated the magnetic behavior of the Mn 1-x Ir x Si system to explore the effect of increased carrier density and spin-orbit interaction on the magnetic properties of MnSi. We determine estimates of the spin wave stiffness and the Dzyalloshinski-Moriya (DM) interaction strength and compare with Mn 1-x Co x Si and Mn 1-x Fe x Si. Despite the large differences in atomic mass and size of the substituted elements, Mn 1-x Co x Si and Mn 1-x Ir x Si show nearly identical variations in their magnetic properties with substitution. We find a systematic dependence of the transition temperature, the ordered moment, the helix period, and the DM interaction strength with electron count for Mn 1-x Ir x Si, Mn 1-x Co x Si, and Mn 1-x Fe x Si, indicating that the magnetic behavior is primarily dependent upon the additional carrier density, rather than on the mass or size of the substituting species. This indicates that the variation in magnetic properties, including the DM interaction strength, is primarily controlled by the electronic structure, as Co and Ir are isovalent. Our work suggests that although the rigid band model of electronic structure, along with Moriya’s model of weak itinerant magnetism, describes this system surprisingly well, phenomenological models for the DM interaction strength are not adequate to describe this system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic Field Control of Cycloidal Domains and Electric Polarization in Multiferroic BiFeO 3

The magnetic field induced rearrangement of the cycloidal spin structure in the room-temperaturemultiferroic BiFeO3 is studied using small-angle neutron scattering (SANS). The cycloid propagationvectors are observed to rotate when magnetic fields applied perpendicular to the polar axisexceed a pinning threshold value of ~5T in the studied crystals. In light of these experimentalresults, a phenomenological model is proposed that describes our observations, and we revisit themicroscopic origin of the magnetoelectric effect. A new term describing a coupling between themagnetic anisotropy and the polarization is proposed to explain the recently discovered magneticfield induced in-plane electric polarization.

36 MATERIALS SCIENCE↗

The 40m General Purpose Small-Angle Neutron Scattering Instrument at Oak Ridge National Laboratory

A high-flux, 40m long small-angle neutron scattering (SANS) instrument has been constructed at Oak Ridge National Laboratory (ORNL). The facility utilizes a mechanical velocity selector, pinhole collimation and a high count-rate (> 105 Hz), large-area (1m2) two-dimensional position-sensitive detector. The incident wavelength (λ), resolution (Δλ/λ), incident collimation and sample-detector distance are independently variable under computer control. The detector can translate 45cm off axis to increase the overall Q-range (< 0.001 < Q = 4πλ-1sin θ < 1 Å-1), where 2θ is the angle of scatter. The design and characteristics of this instrument are described along with examples of scattering data to illustrate the performance.

biology↗

A scattering function of star polymers including excluded volume effects

In this work we present a new model for the form factor of a star polymer consisting of self-avoiding branches. This new model incorporates excluded volume effects and is derived from the two point correlation function for a star polymer.. We compare this model to small angle neutron scattering (SANS) measurements from polystyrene (PS) stars immersed in a good solvent, tetrahydrofuran (THF). It is shown that this model provides a good description of the scattering signature originating from the excluded volume effect and it explicitly elucidates the connection between the global conformation of a star polymer and the local stiffness of its constituent branch.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interoperable, Inverter - Based Distributed Energy Resources Enable 100% Renewable and Resilient Utility Microgrids

As microgrids transition away from use of conventional generating resources and increasingly rely on renewable resources towards decarbonization goals, it is crucial to evaluate the capability inverter-based resources to provide microgrid stability and resilience. Particularly, microgrids with a high contribution of intermittent solar photo voltaic generation and higher load variability present unique challenges requiring fast voltage and frequency support. At the San Diego Gas & Electric Company(R) (SDG&E(R)) Borrego Springs Microgrid, a battery inverter was upgraded with grid-forming (GFM) capability to serve as island leader, transitioning responsibility away from diesel generators. An interoperable microgrid control scheme was developed, coordinating GFM and grid-following (GFL) inverters. Hardware-in-the-loop (HIL) simulations using relevant power and controller HIL interfaces between real-time simulators and field equipment are being conducted to de-risk field deployment.

battery energy storage↗

Potential Benefits of Vehicle-to-Grid Technology in California: High Value for Capabilities Beyond One-Way Managed Charging

With Electric Vehicles (EVs) Rapidly becoming more popular, combined with a need for flexible energy storage resources in the electric grid, the development of vehiclegrid integration (VGI) technology has taken on a new urgency. VGI encompasses any technology that helps EVs better integrate with the grid, including management of charging and control of bidirectional charging and discharging. The habit of managing the one-directional flow of power from the grid to vehicles (V1G) is currently being rolled out across California and in many places where EVs have become popular. V1G programs in California include San Diego Gas and Electric's Power Your Drive, EV-specific retail tariffs from Southern California Edison, and the Charge Forward smart charging pilot program from Pacific Gas and Electric in collaboration with automaker BMW.

25 ENERGY STORAGE↗

Considerations for AMI-Based Operations for Distribution Feeders

More than $5 billion in investments in advanced metering infrastructure (AMI) technologies, AMI deployments, as pervasive secondary network voltage monitoring systems, provide opportunities for utility operations and controls. This paper focuses on the considerations for AMI-based tools and techniques as the industry moves toward operationalizing such large data sets. Phase identification is a first such tool. Numerous distribution network analysis, monitoring, and control applications - including volt/volt-ampere reactive control, state estimation, and distribution automation - require accurate phase connectivity information in the system models. The phase connectivity database maintained by utilities is inaccurate because of a significant amount of missing data, restoration activities, and network reconfiguration. Existing phase identification techniques that estimate phase connectivity work well in distribution feeders that have low or no photovoltaic (PV) generation; however, they fail to identify the phases accurately when considerable PV generation is present. This work addresses the phase identification problem in the presence of high PV generation using statistical analysis methods. Further, insights into the AMI data requirements for this application in terms of data window length and resolution are provided using sensitivity analysis performed on an actual distribution feeder model of San Diego Gas & Electric Company. The results of this study show that the phase connectivity, even in the presence of high PV generation, can be accurately identified using statistical analysis of AMI data of 1 day.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops a machine learning based approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurement. The machine learning model is developed by using random forest algorithm. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

advanced metering infrastructure↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data

Many distribution network monitoring and control applications - including state estimation, volt/VAR optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure↗

Spatial-Temporal PV Hosting Capacity Estimation and Evaluation

Evaluating Photovoltaic Hosting Capacity (PVHC) is an essential step in the process of integrating solar energy into power grids, particularly when focusing on the distribution network (DN) as the primary integration target. PVHC needs to be investigated, especially in cases where the grids are unbalanced, and their operational conditions vary spatially and temporally. This motivation prompted us to propose a scalable model tailored to this application. In this paper, we applied linearization to the alternating current optimal power flow (AC-OPF) and solar inverters, transforming the original problem into a mixed-integer linear programming (MILP) problem. Additionally, we accounted for the battery energy storage system (BESS) as a time-coupling factor for calculating PVHC. We then compared the PVHC results between the IEEE-13 bus and SMART-DS San Francisco (SFO) cases and discussed the extent to which BESS can enhance the PVHC of a DN. Furthermore, we designed a web-based graphical visualization for the SFO case, enabling user interaction with raw data and simulation results on a map through a graphical user interface (GUI). In summary, our results and findings provide valuable insights for future three-phase unbalanced AC-OPF PVHC practices and their visualization.

AC-optimal power flow↗

An Energy Storage Cost Comparison: Li-Ion Batteries vs Distributed Load Control

In 2017, San Diego Gas & Electric installed a 30 MW, 120 MWh lithium-ion battery storage facility-the world's largest at the time. But, recent work demonstrates that local control can enable flexible loads to provide equivalent battery-like services to the grid. Our cost comparison shows that it is much cheaper to acquire 30 MW, 120 MWh of capacity by retro-fitting 120,000 water heaters with control hardware and telecommunications. Surprisingly, it may even be cheaper to give away 120,000 'smart' water heaters!

25 ENERGY STORAGE↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation

Utilities have been installing microgrids because of the increased resilience and reliability advantages they may provide to the distribution system. A microgrid controller is a critical component in microgrids. It is of great benefit to derisk the installation of microgrid controllers before field deployment. Hardware-in-the-loop (HIL) testing is used by controller developers and utilities to evaluate the controllers under stressful conditions. In this work, a microgrid control function developed by the Synchrophasor Grid Monitoring and Automation (SyGMA) laboratory at the University of California, San Diego is tested in a remote HIL (RHIL) setup. The digital real-time simulation of the detailed microgrid system was operated at the National Renewable Energy Laboratory's Energy Systems Integration Facility. Under such RHIL setup, successful controller operation is contingent on understanding and characterizing the communications channel and in particular network latencies. The novelty of this paper is the proposed use of a RHIL setup that leverages existing power system communications protocols to evaluate the controller in conjunction with the simulation capabilities of a remote facility. The work presented here will provide the complete setup of the HIL evaluation platform, the details of the communications protocols used by the setup for data transfer between the two organizations, test cases developed to evaluate the controller, and the results from the experiments.

controller hardware-in-the-loop↗

PV Hosting Capacity Estimation: Experiences with Scalable Framework

Hosting capacity is an indication of the amount of solar photovoltaics (PV) that can be hosted in a distribution system without additional changes to infrastructure or oper-ations. This paper presents a framework for estimating the PV hosting capacity at scale. First, we analyze computational, modeling and other key challenges of performing relevant, large-scale simulations, provided along with the experiences and lessons learned. Then, we develop two open-source Python-based software tools to conduct repeatable distribution analyses: the Distribution Integration Solution Cost Options (DISCO) for configuring and analyzing simulations and the Job Automation and Deployment Engine (JADE) for parallelizing jobs on high-performance computing clusters. A case study of hosting capacity estimation for the SMART-DS San Francisco (SFO) 2000+ synthetic feeders, is used to demonstrate the capability of the developed DISCO+JADE framework and tools. The framework and tools can help utilities assess the overall hosting capacity of their service territory, which can help them better plan for the overall upgrade costs to integrate more PV in the future. The experiences are shared to aid the tool users and researchers to conduct relevant studies and research.

distributed energy resources↗

Scalable Earthquake Simulation on Petascale Supercomputers

NPetascale simulations are needed to understand the rupture and wave dynamics of the largest earthquakes at shaking frequencies required to engineer safe structures (> 1 Hz). Toward this goal, we have developed a highly scalable, parallel application (AWP-ODC) that has achieved “M8”: a full dynamical simulation of a magnitude-8 earthquake on the southern San Andreas fault up to 2 Hz. M8 was calculated using a uniform mesh of 436 billion 40-m 3 cubes to represent the three-dimensional crustal structure of Southern California, in a 800 km by 400 km area, home to over 20 million people. This production run producing 360 sec of wave propagation sustained 220 Tflop/s for 24 hours on NCCS Jaguar using 223,074 cores. As the largest-ever earthquake simulation, M8 opens new territory for earthquake science and engineering - the physics-based modeling of the largest seismic hazards with the goal of reducing their potential for loss of life and property.

Cui, Yifeng↗

Simulation-Based Analysis of Feeder Operation with Different PV Smart Inverter Functions on an Actual Distribution System: Preprint

High penetration of photovoltaics (PV) in distribution feeders can cause problems, such as overvoltage, reverse power flow, and large net load changes. Traditional voltage regulation devices, such as capacitors and voltage regulators, can solve some of these problems but might have some delays. Today, smart inverters are gradually being used to provide voltage regulation and frequency support in distribution systems. Different smart inverter settings have been recommended in various rules and standards; however, the potential benefits and their impacts on distribution system operation are not well compared and studied. This paper presents a comparison of different smart inverter settings as applied to a distribution system. An actual feeder model from San Diego Gas & Electric Company is used to conduct the simulation. Additionally, a load disaggregation method is proposed to disaggregate the load and PV profile for each load location using advanced metering infrastructure net load measurements. Then, different smart inverter settings are applied to the PV systems in the feeder, and the simulation results are compared. The results show that the implementation of specific functions of smart inverters can reduce voltage exceedances, and the utility can determine the specific inverter setting based on its operational requirements.

distribution system↗