Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Rock sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Application LANDSAT imagery to geologic mapping in the ice-free valleys of Antarctica

The author has identified the following significant results. Studies in the Ice-Free Valleys are resulted in the compilation of a sizeable library of maps and publications. Rock reflectance measurements were taken during the Antarctic summer of 1973. Spectral reflectance of rocks (mostly mafic lava flows) in the McMurdo and Ice-Free Valleys areas were measured using a filter wheel photometer equipped to measure reflectances in the four Landsat bands. A series of samples were collected at regular intervals across a large differentiated, mafic sill near Lake Vida. Chemical analyses of the sample suggest that the tonal variations in this sill are controlled by changes in the iron content of the rock. False color images were prepared for a number of areas by the diazo method and with an optical multispectral biviewer. These images were useful in defining boundaries of sea ice, snow cover, and in the study of ablating glaciers, but were not very useful for rock discrimination.

Houston, R. S.↗

Stress-Dependent Voltage Offsets From Polymer Insulators Used in Rock Mechanics and Material Testing

Dielectric insulators are used in a variety of laboratory settings when performing experiments in rock mechanics, petrology, and electromagnetic studies of rocks in the fields of geophysics,material science, and civil engineering. These components may be used to electrically isolate geological samples from the experimental equipment, to perform a mechanical compliance function between brittle samples and the loading equipment, to match ultrasonic transducers, or perform other functions. In manyexperimental configurations the insulators bear the full brunt of force applied to the sample but do not need to withstand high voltages, therefore the insulators are often thin sheets of mechanically tough polymers. From an instrument perspective, transduction from various types of mechanical perturbation has beenqualitatively compared for a number of polymers [1, 2] and these error sources are readily apparent duringhigh-impedance measurements if not mitigated. However even when following best practices, a force dependent voltage signal still remains and its behavior is explored in this presentation. In this experimenttwo thin sheets (0.25 mm) of high-density polyethylene (HDPE) were set up in a stack, held alternatelybetween three aluminum bars; this stack was placed on the platen of a 60T capacity hydraulic testingmachine. The surface area, A, over which the force is applied to the PE sheets in this sandwich is roughly 40 square cm, each sheet forming a parallel-plate capacitor having roughly 320 pF [3], assuming therelative dielectric permittivity of PE is approximately 2.3. The outer two aluminum bars were connected to the LO input ofthe electrometer and the central aluminum bar was connected to the HI input of a Keithley model 617 electrometer. Once the stack is mechanically well-seated with no air gaps, the voltage offset is observed tobe a linear function of the baseline voltage for a given change in applied force. For a periodically appliedforce of 66.7 kN the voltage offsets were measured as a function of initial voltage, and these data were fitwith a linear function that was constrained to pass through the origin. The best fit solution had a correlation coefficient of R=0.85 and a slope of approximately -0.0228 volts/volt. The voltage offset when normalizedis demonstrated to be constant -2.28% for both positive and negative polarities over nearly 3 orders ofbaseline voltage magnitude. From this, the voltage-force coefficient is derived to be -0.34 ppm/N. Thiscorrelates well to a first-order parallel plate capacitor model that assumes constant area, and smalldeformation such that the polymer may be mechanically modeled by a spring that obeys Hookes law. Thissimple model predicts that the coefficient of proportionality is a function of Youngs modulus E= 0.8 GPaand surface area of the insulator, theoretically -1EA= -0.31 ppm/N. The outcome of this work is animproved insulator made from ultra-high molecular weight (UHMW) polyethylene and other approachestoward the minimization of and compensation for these experimental artifacts.

Electromagnetic Studies of Rocks↗

Ar-40/Ar-39 ages of six Apollo 15 impact melt rocks by laser step heating

Fifteen high resolution (21-51 step) Ar-40/Ar-39 age spectra are obtained for six Apollo 15 impact melt rocks of different compositions, using a continuous laser system on submilligram subsamples and on single crystal plagioclase clasts. Four of the six samples gave reproducible age spectra with well-defined intermediate temperature plateaus over 48 percent or more of the Ar-39 released; the plateaus are interpreted as crystallization ages. Samples 15304,7,69, 15294,6,21 and 15314,26,156 gave virtually identical plateau ages whose weighted mean is 3870 + or - 6 Ma. These three melt rocks differ in composition and likely formed in three separate impact events.

Dalrymple, G. B.↗

Remanent magnetization of lunar samples.

The remanent magnetization of samples returned from the moon by the Apollo 11 and 12 missions consists, in most cases, of two distinct components. An unstable component is readily removed upon alternating field (AF) demagnetization in fields less than 100 Oe and is considered to be an isothermal remanence acquired during or after return to earth. The second component is unaltered by demagnetization in fields up to 400 Oe. It is probably a thermoremanent magnetization due to cooling from above 800 C in the presence of a field of a few thousand gammas. Chips from individual rocks have the same direction of magnetization after demagnetization, while the directions of different samples are random. This again demonstrates the high stability. Our data imply that the moon experienced a magnetic field that lasted at least from about 3.0 to 3.8 b.y., which is the age of Apollo 11 and 12 samples. One explanation of the origin of this field is that the moon had a liquid core and a self-exciting dynamo early in its history.

Strangway, D. W.↗

Preliminary Examination Process of Apollo Core 73002 - Insights and Lessons Learned From ANGSA for Future Sample Return Missions

Apollo Sample 73002 is part of a 2-foot long “drive tube” (73001/73002) of regolith that was collected from a landslide deposit near Lara Crater at the Apollo 17 site, Station 3. The double drive tube is believed to have penetrated a lunar landslide deposit that was transported from the slope of the South Massif into the TLV [1]. As part of the ANGSA (Apollo Next Generation Sample Analyses) initiative, preparing preliminary examination (PE) catalog of 73002 is a crucial first step for the early identification of material types such as rock fragments, and potential stratigraphy within the core. PE of Apollo core 73002 is distinct from science activities with the main goal to produces a sample catalog with a level of detail about sample characterization that is sufficient for the ANGSA PIs (and later on the lunar sample community) to select and request the samples to conduct their individual, scientific studies. Ultimately, the PE catalog of 73002 will help to establish a better understanding of the stratigraphy of the land slide deposit; the processes of the landslide including the trigger(s) and possibly number of landslide events, as well as the role of volatiles [1] and will aid in the careful preservation of the material for future studies [2].

Apollo↗

Cerium Stable Isotope Analysis of Synthetic and Terrestrial Rock Reference Materials by MC-ICPMS

Cerium is the most abundant rare earth element (REE) in the solar photosphere, CI chondrites, and the Earth. It has four main stable isotopes (masses: 136,138,140, and 142), with 138Ce being the most studied species, used in geochronology and petrogenesis. In addition, more abundant 140Ce and 142Ce are suggested to be potentially applicable in geochemical investigations. In this work, we developed a modified four-step ion chromatography procedure for Ce chemical separation. Using a MC-ICPMS, we designed a cup configuration to measure 142Ce/140Ce ratio of the samples with an optimized Nd correction equation. A 0.03‰ (2SD) reproducibility was obtained for Ce Ames metal standard. We analyzed ten different igneous and one sedimentary geochemical reference materials. Mean δ142Ce range from −0.07 to 0.32‰. Most of the samples show a heavier Ce isotopic composition than the Ce Ames standard. The majority of rocks have a homogenous δ142Ce. The δ142Ce does not show any correlation with rock chemical composition including their Ce content or rock types. A carbonatite (SARM 40) has a mean δ142Ce of −0.07 ± 0.13‰ (2SD), lower than the other rocks, suggesting the possibility of a pronounced isotopic fractionation. Our work demonstrates the applicability of the developed methodology and the potential of Ce stable isotopes for future geochemical studies. Production of a larger database of δ142Ce values is required to obtain a clearer view on the similarities and differences between different geological material and explaining Ce stable isotope dynamics.

Cerium↗

Lu-Hf and Sm-Nd geochronological constraints on the influence of subduction metamorphism in controlling the Hf-Nd terrestrial array: Evidence from the world’s orogenic belts

To create a better understanding of the influence of subduction metamorphism on the Hf-Nd terrestrial array, this study examines all of the available Lu-Hf and Sm-Nd garnet isochron ages from the world’s orogenic eclogites and amphi bolites. The garnet isochron y-intercept values provide a record of each sample’s epsilon Hf ( ε Hf) and Nd ( ε Nd) at the age recorded by the isochron, which in the case of most orogenic eclogites and amphibolites is the time of prograde metamorphism during subduction. It is further possible to assess the extent to which each sample’s Lu-Hf and Sm-Nd isotope systematics have remained undisturbed since the date recorded by the isochron by comparison of the bulk-rock isotope systematics with the isochron initial value. This approach provides a means of understanding the Lu-Hf and Sm-Nd systematics of post-subduction metamorphic oceanic crust. On a global scale, the coupled Lu-Hf and Sm-Nd isotope systematics of this crust closely align with the Hf-Nd terrestrial array and have average 176 Lu/ 177 Hf and 147 Sm/ 144 Nd ratios within error of the chondritic uniform reservoir values. This is an important finding because it suggests that a reservoir of deeply subducted oceanic crust, possibly residing at the core-mantle boundary, is unlikely to be significantly fractionated from the Hf-Nd terrestrial array. In contrast to the samples of subduction-metamorphosed oceanic crust, metamorphic rocks with a continental crustal protolith demonstrate garnet isochron initial values and bulk-rock Lu-Hf and Sm-Nd isotope systematics indicating significant decoupling from the Hf-Nd terrestrial array. However, because this material is not readily subducted, this strongly decoupled signature is unlikely to be transferred into deep Earth. Mixing calculations aimed at developing a clearer understanding of what factors control decoupling of a sample’s Lu-Hf and Sm-Nd systematics from the Hf-Nd terrestrial array highlight the complexity of mass-transfer regimes operating in the subduction environment.

54 ENVIRONMENTAL SCIENCES↗

Thermal expansion of Apollo lunar samples and Fairfax diabase.

Measured values of the thermal expansion of seven Apollo samples over the temperature range -100 C to +200 C are reported and compared to terrestrial Fairfax diabase. For most of the lunar rocks the measured expansion is significantly lower (30%) than the intrinsic value calculated from Turner's equation for the thermal expansion of an aggregate. The measured expansion of the Fairfax diabase was equal to the intrinsic but was higher for samples of Fairfax which had been previously cycled to high temperatures. The effect of microfractures on the thermal expansion of rocks is discussed.

Baldridge, W. S.↗

Mixing levels, the Apennine Front soil component, and compositional trends in the Apollo 15 soils

New compositional data (by INAA) for 29 samples of Apollo 15 soil fractions are presented along with data for six depth intervals of the bottom half of the double drive tube at station 2 on the Apennine Front. The compositional trends in the Apollo 15 soils are discussed in terms of four techniques used to determine the important components of the regolith: graphical techniques, factor analysis, chemical analysis of individual soil particles, and mixing models. The concept of 'mixing levels' is introduced, which states that a sample of lunar regolith can be considered as a mixture on several different compositional levels (I, igneous rock types; II, local rock types; III, soils), and it is shown that most attempts at modeling lunar soils as mixtures have been directed at level II. It is argued that only four components are required to account for the variation in concentrations of lithophile elements in the Apollo 15 samples: mare basalt, KREEP basalt, green glass, and Apennine front soil (best represented by the station 2 samples).

Korotev, Randy L.↗

An ICP-OES method for the precise and accurate quantification of rare earth elements in natural water: A comparative study from mine waste sites in New Mexico, USA

Inductively coupled plasma techniques such as ICP-OES and ICP-MS are routinely used to determine the concentrations of rare earth elements (REE) in water samples. However, their performance for the determination of REE concentration in mine drainage waters from epithermal vein and porphyry copper mining districts has not been evaluated extensively. In this work, we develop an REE analysis method on an Agilent 5900 ICP-OES instrument and assess the accuracy and precision for the quantification of REE in the natural waters collected from mine adits and an acid seep of mine sites in the Steeple Rock and Hillsboro mining districts, New Mexico, USA. The total REE concentrations in the water samples were measured using the methods we developed for both ICP-OES and ICP-MS. The power of the new ICP-OES method lies in routine analysis of μg/L level concentrations normally analyzed using ICP-MS, including a U.S. Geological Survey standard reference sample, laboratory blank samples spiked with a National Institute of Standards and Technology traceable standard, and surface water samples from mine waste sites. This ICP-OES method achieves low quantification limits ranging from 0.2 to 5 μg/L and excellent analytical accuracy and precision for REE analysis. The precision of light (La-Gd) and heavy (Tb-Lu) REE analysis using this method are better than 5% at average concentrations above 5 ± 4 μg/L and 3 ± 2 μg/L, respectively, and 3% at average concentrations above 10 ± 9 μg/L and 5 ± 4 μg/L, respectively. This method also shows excellent sensitivity and reproducibility for our laboratory and field samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of the Split Hopkinson Resonant Bar Test for Seismic Property Characterization of Hydrate-bearing Sand Undergoing Water Saturation

Conventional resonant bar tests allow the measurement of seismic properties of rocks and sediments at low frequencies (several kilohertz). However, the tests require a long, slender sample which is often difficult to obtain from the deep subsurface and weak and fractured formations. We present an alternative low-frequency measurement technique to the conventional resonant bar tests. This technique involves a jacketed core sample placed between a pair of long, metal extension rods with attached seismic source and receiver—the same geometry as the split Hopkinson pressure bar test for large-strain, dynamic impact experiments. Because of the added length and mass to the sample, the resonance frequency of the entire system can be lowered significantly, compared to the sample alone. The proposed “Split Hopkinson Resonant Bar (SHRB)” test is applied in two steps. In the first step, extension and torsion-mode resonance frequencies and attenuation of the system are measured. Then, numerical inversions for the compressional and shear wave velocities and attenuation are performed. We initially applied the SHRB test to synthetic materials (plastics) for testing its accuracy, then used it for measuring the seismic velocities and attenuation of a rock core containing supercritical CO 2 , and a sediment core while methane hydrate formed in the pore space.

54 ENVIRONMENTAL SCIENCES↗

The first X-ray diffraction measurements on Mars

The Mars Science Laboratory landed in Gale crater on Mars in August 2012, and the Curiosity rover then began field studies on its drive toward Mount Sharp, a central peak made of ancient sediments. CheMin is one of ten instruments on or inside the rover, all designed to provide detailed information on the rocks, soils and atmosphere in this region. CheMin is a miniaturized X-ray diffraction/X-ray fluorescence (XRD/XRF) instrument that uses transmission geometry with an energy-discriminating CCD detector. CheMin uses onboard standards for XRD and XRF calibration, and beryl:quartz mixtures constitute the primary XRD standards. Four samples have been analysed by CheMin, namely a soil sample, two samples drilled from mudstones and a sample drilled from a sandstone. Rietveld and full-pattern analysis of the XRD data reveal a complex mineralogy, with contributions from parent igneous rocks, amorphous components and several minerals relating to aqueous alteration. In particular, the mudstone samples all contain one or more phyllosilicates consistent with alteration in liquid water. In addition to quantitative mineralogy, Rietveld refinements also provide unit-cell parameters for the major phases, which can be used to infer the chemical compositions of individual minerals and, by difference, the composition of the amorphous component.

Chemistry↗

Fluid-Evaporation Records Preserved in Meridiani Rocks

We have shown earlier that the high SO3/Cl ratios found in secondary mineral assemblages in shergottite GRIM glasses (Gas-Rich Impact-Melt) likely resulted from interactions of regolith materials with sulfate-rich (and Cl-poor) solutions. The low SO3/Cl ratios determined in secondary salts in nakhalite fracture-fillings presumably formed by rock interactions with chloride-rich (and SO4-poor) solutions near Mars surface. The SO3 and Cl abundances determined by APXS in abraded rocks (RAT) from Endurance, Fram and Eagle craters indicate that these salt assemblages likely formed by evaporative concentration of brine fluids at Meridiani. The SO3/Cl ratios in the abraded rocks are examined here, instead of their absolute abundances, because the abundance ratios might provide better guide-lines for tracking the evolution of evaporating fluids at Meridiani. The SO3/Cl ratios in these samples, in turn, might provide clues for the mobile element ratios of the altering fluids that infiltrated into the Meridiani rocks.

Rao, M. N.↗

Exploring the Utilization of Low-Pressure, Piston-Cylinder Experiments to Determine the Bulk Compositions of Finite, Precious Materials

Determining the bulk composition of precious materials with a finite mass (e.g., meteorite samples) is extremely important in the fields of Earth and Planetary Science. From meteorite studies we are able to place constraints on large scale planetary processes like global differentiation and subsequent volcanism, as well as smaller scale processes like crystallization in a magma chamber or sedimentary compaction at the surface. However, with meteorite samples in particular, far too often we are limited by how precious the sample is as well as its limited mass. In this study, we have utilized aliquots of samples previously studied for toxicological hazards, including both the fresh samples (lunar mare basalt NWA 4734, lunar regolith breccia NWA 7611, martian basalt Tissint, martian regolith breccia NWA 7034, a vestian basalt Berthoud, a vestian regolith breccia NWA 2060, and a terrestrial mid-ocean ridge basalt (MORB)), and those that underwent iron leaching (Tissint, NWA 7034, NWA 4734, MORB). With these small masses of material, we performed low pressure (approx. 0.75 GPa), high temperature (greater than 1600 degrees Celsius) melting experiments. Each sample was analyzed using a JEOL 8530F electron microprobe to determine the bulk composition of the materials that were previously examined. When available, the results of our microprobe data were compared with bulk rock compositions in the literature. The results of this study show that with this technique, only approx. 50 mg of sample is required to accurately determine the bulk composition of the materials of interest.

Vander Kaaden, K. E.↗

Space Rocks Tell Their Secrets: Space Science Applications of Physics and Chemistry for High School and College Classes

As the scientific community studies Mars remotely for signs of life and uses Martian meteorites as its only available samples, teachers, students, and the general public continue to ask, "How do we know these meteorites are from Mars?" This question sets the stage for a three-lesson instructional package Space Rocks Tell Their Secrets. Expanding on the short answer "It's the chemistry of the rock", students are introduced to the research that reveals the true identities of the rocks. Since few high school or beginning college students have the opportunity to participate in this level of research, a slide presentation introduces them to the labs, samples, and people involved with the research. As they work through the lessons and interpret real data, students realize that the research is an application of basic science concepts they should know, the electromagnetic spectrum and isotopes. They can understand the results without knowing how to do the research or operate the instruments.

Lindstrom, M. M.↗

The Search for Organic Compounds of Martian Origin in Gale Crater by the Sample Analysis at Mars (SAM) Instrument on Curiosity

One of the key objectives of the Mars Science Laboratory rover and the Sample Analysis at Mars (SAM) instrument suite is to determine the inventory of organic and inorganic volatiles in the atmosphere and surface regolith and rocks to help assess the habitability potential of Gale Crater. The SAM instrument on the Curiosity rover can detect volatile organic compounds thermally evolved from solid samples using a combination of evolved gas analysis (EGA) and gas chromatography mass spectrometry (GCMS) (Mahaffy et al. 2012). The first solid samples analyzed by SAM, a scoop of windblown dust and sand at Rocknest, revealed several chloromethanes and a C4-chlorinated hydrocarbon derived primarily from reactions between a martian oxychlorine phase (e.g. perchlorate) and terrestrial carbon from N-methyl-N-(tertbutyldimethylsilyl)- trifluoroacetamide (MTBSTFA) vapor present in the SAM instrument background (Glavin et al. 2013). After the analyses at Rocknest, Curiosity traveled to Yellowknife Bay and drilled two separate holes in a fluvio-lacustrine sediment (the Sheepbed unit) designated John Klein and Cumberland. Analyses of the drilled materials by both SAM and the CheMin X-Ray Diffraction instrument revealed a mudstone consisting of ~20 wt% smectite clays (Ming et al. 2013; Vaniman et al. 2013), which on Earth are known to aid the concentration and preservation of organic matter. Oxychlorine compounds were also detected in the Sheepbed mudstone during pyrolysis; however, in contrast to Rocknest, much higher levels of chloromethanes were released from the Sheepbed materials, suggesting an additional, possibly martian source of organic carbon (Ming et al. 2013). In addition, elevated abundances of chlorobenzene and a more diverse suite of chlorinated alkanes including dichloropropane and dichlorobutane detected in Cumberland compared to Rocknest suggest that martian or meteoritic organic carbon sources may be preserved in the mudstone (Freissinet et al. 2013). Chloromethane and dichloromethane were also identified after thermal volatilization of the surface soils by the GCMS instruments at the Viking landing sites, although no other chlorinated hydrocarbons were reported (Biemann et al. 1977). Here we focus on the origin of the chlorinated hydrocarbons detected in the Sheepbed mudstone by SAM and the implications for the preservation of organic matter in near-surface materials on Mars.

Mars Curiosity Rover↗

Investigating the Sources and Timing of Projectiles Striking the Lunar Surface

The lunar surface is exposed to bombardment by asteroids, comets, and debris from them. Surviving fragments of those projectiles in the lunar regolith provide a direct measure of the sources of exogenous material delivered to the Moon. Con-straining the temporal flux of their delivery will directly address key questions about the bombardment history of the inner Solar System. Regolith breccias, which are consolidated samples of the lunar regolith, were closed to further impact processing at the time they were assembled into rocks [1]. They are, therefore, time capsules of impact bombardment at different times through lunar history. Here we investigate the impact archive preserved in the Apollo 16 regolith breccias and compare this record to evidence of projectile species in other lunar samples.

Joy, K. H.↗

The advanced ion-milling method for preparation of thin film using ion slicer: Application to a sample recovered from diamond-anvil cell

The advanced argon ion-milling technique using a new instrument called ion slicer was newly developed for preparation of thin foil. Compared to the conventional ion-milling methods, this technique facilitates very wide area to be homogeneously thinned by rocking the ion beam source with low angle and the specimen during milling. Here we applied this technique to a sample recovered from a laser-heated diamond-anvil cell (DAC). We obtained the thin film of almost entire cross section of the DAC sample along the compression axis, which possesses of {approx}(10x50) {mu}m{sup 2}. The laser-heated sample is often heterogeneous due to a large temperature gradient. However the chemical analyses are obtained from the whole hot spot under the transmission electron microscope by preparing the thin foil using the ion slicer.

36 MATERIALS SCIENCE↗