Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Relative accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Building America Case Study: Predicting Envelope Leakage in Attached Dwellings (Fact Sheet)

'The cost for blower testing is high, because it is labor intensive, and it may disrupt occupants in multiple units. This high cost and disruption deters program participants, and dissuades them from pursuing energy improvements that would trigger air leakage testing, such as improvements to the building envelope.' This statement found in a 2012 report by Heschong Mahone Group emphasizes the importance of reducing the cost and complexity of blower testing in multifamily buildings. Energy efficiency opportunities are being bypassed. The cost of single blower testing is on the order of $300. The cost for guarded blower door testing, the more appropriate test for assessing energy savings opportunities, could easily be six times that and that's only if you have the equipment and simultaneous access to multiple apartments. Thus, the proper test is simply not performed. The objective of the 2013 research project was to develop the model for predicting fully guarded test results (FGT), using unguarded test data and specific building features of apartment units. The model developed has a coefficient of determination R2 value of 0.53 with a root mean square error (RMSE) of 0.13. Both statistical metrics indicate that the model is relatively strong. When tested against data that was not included in the development of the model, prediction accuracy was within 19%, which is reasonable given that seasonal differences in blower door measurements can vary by as much as 25%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Subgrid Treatment of Spacer Grids in the 2D/1D Subplane Approach

Recent efforts have focused on improving the performance of the 2D/1D subplane implementation in MPACT. One of the developments recently added, presented here, focuses on treating spacer grids using a subgrid approach within each subplane, avoiding the extra computation and potentially improving stability issues that can be present by explicitly modeling the spacer grid with a separate MOC plane. From the cases analyzed, it seems that the approach does a sufficient job of maintaining the accuracy of explicitly meshing the spacer grid (<10 pcm and <1% max pin power error) while offering relatively modest performance gains. Overall, the success of the approach with spacer grids opens up possibilities to apply similar approaches to other structural components, particularly those in the axial reflectors to reduce the number of MOC planes and overall computational burden.

Stimpson, Shane G.↗

Side-by-Side Comparison of Subhourly Clipping Models

Over the past several years there have been numerous attempts at quantifying the inherent power clipping of inverters due to sub-hourly irradiance variability that is not captured in hourly PV performance models. Different models have been proposed to correct for these clipping losses in PV performance estimates, including matrix lookup models, distribution modeling of the PV power performance within a given hour, and machine learning methods. To date, there have been few comprehensive quantitative comparisons of these inverter clipping correction modeling approaches to evaluate the effectiveness of these approaches in predicting the actual behavior of PV system inverter clipping. In this study, we perform such a comparison, evaluating the Allen and Walker correction loss modeling approaches recently implemented in the System Advisor Model (SAM) against clipping losses modeled with 1-minute climate data. These comparisons were performed across a variety of climate locations and inverter loading ratios to thoroughly analyze the effectiveness of these modeling approaches relative to each other. Results from this analysis reveal that both clipping correction approaches improve annual energy accuracy to within 2% of 1-minute modeled energy yield. The two models predict annual clipping loss more accurately than simple hourly power limit clipping, with the Allen method typically being slightly more accurate at typical ILR values and the Walker method often being slightly more accurate at high ILR values The models can improve accuracy over the status quo clipping approach up to 3 percentage points in systems with ILR of 2.0, showing the importance of this modeling factor in energy yield estimates.

ENERGY PLANNING, POLICY, AND ECONOMY,MATHEMATICS A↗

Side-by-Side Comparison of Subhourly Clipping Models: Preprint

Over the past several years there have been numerous attempts at quantifying the inherent power clipping of inverters due to inter-hourly irradiance variability that is not captured in hourly PV performance models. Different models have been proposed to correct for these clipping losses in PV performance estimates, including matrix lookup models, distribution modeling of the PV power performance within a given hour, and machine learning methods. To date, there have been few comprehensive quantitative comparisons of these inverter clipping correction modeling approaches to evaluate the effectiveness of said approaches in predicting the actual behavior of PV system inverter clipping. In this study, we perform such a comparison, evaluating two different clipping correction loss modeling approaches recently implemented in the System Advisor Model (SAM) against clipping losses modeled with 1-minute climate data. These comparisons will be performed across a variety of climate locations and inverter loading ratios to thoroughly analyze the effectiveness of these modeling approaches relative to each other. Results from this analysis reveal that both clipping correction approaches improve annual energy accuracy to within 2% of 1-minute modeled energy yield. The models can improve accuracy up to 3% in systems with ILR of 2.0, showing the importance of this modeling factor in energy yield estimates.

clipping↗

Tool-Based Case Studies on Strategic Deployment of Untapped Micro-Pumped Hydro Storage in Michigan

With most classical hydropower sites already utilized and the global push for rapid integration of renewable energy sources accelerating, there is a critical need to identify alternative energy storage solutions. Pumped hydro energy storage, which accounts for the vast majority of global grid-scale storage, remains one of the most cost-effective and long-duration storage technologies available. Hence, this study presents a novel tool designed to assess the untapped potential of inland lakes and reservoirs for micro-PSH, using Michigan’s relatively flat landscape as a case study due to its extensive but underutilized water infrastructure. To ensure accuracy and reliability, the tool incorporates extensive data gathered from authorized sources, covering more than 420 water facilities and potential reservoirs in the state. The tool evaluates key parameters such as horizontal and vertical distances, volume, and the total storage capacity of each reservoir. Its robust assessment framework integrates these metrics to evaluate each site’s potential. The tool’s intuitive interface and geospatial visualizations support actionable insights for planners and scalable deployment of distributed storage infrastructure.

13 HYDRO ENERGY↗

Three-body problem in heteronuclear mixtures with resonant interspecies interaction

We use the zero-range approximation to study a system of two identical bosons interacting resonantly with a third particle. The method is derived from effective field theory. It reduces the three-body problem to an integral equation which we then solve numerically. We also develop an alternative approach which gives analytic solutions of the integral equation in coordinate representation in the limit of vanishing total energy. The atom-dimer scattering length, the rates of atom-dimer relaxation, and the three-body recombination to shallow and to deep molecular states are calculated either analytically or numerically with a well-controlled accuracy for various energies as functions of the mass ratio, scattering length, and three-body parameter. We discuss in detail the relative positions of the recombination loss peaks, which in the universal limit depend only on the mass ratio. Our results have implications for ongoing and future experiments on Bose-Bose and Bose-Fermi atomic mixtures.

74 ATOMIC AND MOLECULAR PHYSICS↗

Assessment of the sources of error affecting the quantitative accuracy of SPECT imaging in small animals

Small animal SPECT imaging systems have multiple potential applications in biomedical research. Whereas SPECT data are commonly interpreted qualitatively in a clinical setting, the ability to accurately quantify measurements will increase the utility of the SPECT data for laboratory measurements involving small animals. In this work, we assess the effect of photon attenuation, scatter and partial volume errors on the quantitative accuracy of small animal SPECT measurements, first with Monte Carlo simulation and then confirmed with experimental measurements. The simulations modeled the imaging geometry of a commercially available small animal SPECT system. We simulated the imaging of a radioactive source within a cylinder of water, and reconstructed the projection data using iterative reconstruction algorithms. The size of the source and the size of the surrounding cylinder were varied to evaluate the effects of photon attenuation and scatter on quantitative accuracy. We found that photon attenuation can reduce the measured concentration of radioactivity in a volume of interest in the center of a rat-sized cylinder of water by up to 50percent when imaging with iodine-125, and up to 25percent when imaging with technetium-99m. When imaging with iodine-125, the scatter-to-primary ratio can reach up to approximately 30percent, and can cause overestimation of the radioactivity concentration when reconstructing data with attenuation correction. We varied the size of the source to evaluate partial volume errors, which we found to be a strong function of the size of the volume of interest and the spatial resolution. These errors can result in large (>50percent) changes in the measured amount of radioactivity. The simulation results were compared with and found to agree with experimental measurements. The inclusion of attenuation correction in the reconstruction algorithm improved quantitative accuracy. We also found that an improvement of the spatial resolution through the use of resolution recovery techniques (i.e. modeling the finite collimator spatial resolution in iterative reconstruction algorithms) can significantly reduce the partial volume errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

INFLUENCE OF THE GALACTIC GRAVITATIONAL FIELD ON THE POSITIONAL ACCURACY OF EXTRAGALACTIC SOURCES

We investigate the influence of random variations of the Galactic gravitational field on the apparent celestial positions of extragalactic sources. The basic statistical characteristics of a stochastic process (first-order moments, an autocorrelation function and a power spectral density) are used to describe a light ray deflection in a gravitational field of randomly moving point masses as a function of the source coordinates. We map a 2D distribution of the standard deviation of the angular shifts in positions of distant sources (including reference sources of the International Celestial Reference Frame) with respect to their true positions. For different Galactic matter distributions the standard deviation of the offset angle can reach several tens of μ as (microarcsecond) toward the Galactic center, decreasing down to 4–6 μ as at high galactic latitudes. The conditional standard deviation (“jitter”) of 2.5 μ as is reached within 10 years at high galactic latitudes and within a few months toward the inner part of the Galaxy. The photometric microlensing events are not expected to be disturbed by astrometric random variations anywhere except the inner part of the Galaxy as the Einstein–Chvolson times are typically much shorter than the jittering timescale. While a jitter of a single reference source can be up to dozens of μ as over some reasonable observational time, using a sample of reference sources would reduce the error in relative astrometry. The obtained results can be used for estimating the physical upper limits on the time-dependent accuracy of astrometric measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Current status and prospects for development of thermometry

The paper deals with results of an analysis carried out at the VNIIM with the purpose to ascertain the current status of thermometry as well as to make an attempt to determine a line of development of this field of measurements in future. The analysis was based on a survey of 150 industrial enterprises and scientific organizations. The results of the survey showed that during two last decades the accuracy of measuring instruments used in science and industry was increased almost tenfold. However, advances in the improvement of temperature measuring instruments were achieved not owing to new principles of designing thermometers, but due to rapid development of electronics, which allowed to solve the problem of accurate measurements of resistance and electromotive force and automatize measurement information processing. In most cases the contemporary measuring instruments perfectly meet the requirements to the measurement accuracy claimed by the enterprises surveyed and are provided with a necessary metrological assurance. Although there is a general understanding of the necessity to use the thermodynamic scale rather than the conditional one, we have no objective evidence with regard to how close we have to bring the international scale used in our everyday practice to the thermodynamic scale and what will be a benefit for development of science and industry. Increasing the accuracy of national standards does not affect, as a rule, the accuracy of temperature measurements in industry and scientific research since the main contribution to a total measurement error is made by components caused by an improper measurement procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of different coarse graining strategies to simulate polydisperse gas-solids flow

Continuum methods require the additional development of solids stress closures for polydisperse powders based on complex kinetic theories that are non-trivial to develop, code, and numerically converge for the wide range of fluidization regimes from very dilute to dense/frictional flow limit. On the other hand, it is straightforward to model the flow of polydisperse granular materials by treating particles as discrete rigid bodies that are tracked following simple physical laws of motion. The coarsening of these discrete methods by lumping several particles in a parcel alleviates the significant computational cost associated with these discrete methods while introducing some inaccuracies in the numerical results. In this research, we explore two different coarse graining methods that can be applied to polydisperse powders, namely the same statistic weight method (SSW) and the same size parcel method (SSP), and assess their accuracy by comparison with the finest simulation results obtained with a discrete element method (DEM). For Geldart group B powders fluidized at a relative low superficial velocity, the numerical results indicate that the SSW is more accurate than the SSP method. For type A powders fluidized at relatively high velocity, these two methods predict similar results. Interestingly, up to four times increase in the speed of simulation of the SSP method was obtained because the original polydisperse powder is scaled to a mono-disperse system in terms of particle-particle collision. Lastly, these results suggest that the SSP method is more favorable for the simulation of fluidized beds due to its accuracy and efficiency while the SSW method may be used for granular flow and dense fluidized bed systems where capturing the size segregation of particles due to collision is important.

42 ENGINEERING↗

The radio continuum-star formation rate relation in WSRT sings galaxies

We present a study of the spatially resolved radio continuum-star formation rate (RC-SFR) relation using state-of-the-art star formation tracers in a sample of 17 THINGS galaxies. We use SFR surface density (Σ{sub SFR}) maps created by a linear combination of GALEX far-UV (FUV) and Spitzer 24 μm maps. We use RC maps at λλ22 and 18 cm from the WSRT SINGS survey and Hα emission maps to correct for thermal RC emission. We compare azimuthally averaged radial profiles of the RC and FUV/mid-IR (MIR) based Σ{sub SFR} maps and study pixel-by-pixel correlations at fixed linear scales of 1.2 and 0.7 kpc. The ratio of the integrated SFRs from the RC emission to that of the FUV/MIR-based SF tracers is R{sub int}=0.78±0.38, consistent with the relation by Condon. We find a tight correlation between the radial profiles of the radio and FUV/MIR-based Σ{sub SFR} for the entire extent of the disk. The ratio R of the azimuthally averaged radio to FUV/MIR-based Σ{sub SFR} agrees with the integrated ratio and has only quasi-random fluctuations with galactocentric radius that are relatively small (25%). Pixel-by-pixel plots show a tight correlation in log-log diagrams of radio to FUV/MIR-based Σ{sub SFR}, with a typical standard deviation of a factor of two. Averaged over our sample we find (Σ{sub SFR}){sub RC}∝(Σ{sub SFR}){sub hyb}{sup 0.63±0.25}, implying that data points with high Σ{sub SFR} are relatively radio dim, whereas the reverse is true for low Σ{sub SFR}. We interpret this as a result of spectral aging of cosmic-ray electrons (CREs), which are diffusing away from the star formation sites where they are injected into the interstellar medium. This is supported by our finding that the radio spectral index is a second parameter in pixel-by-pixel plots: those data points dominated by young CREs are relatively radio dim, while those dominated by old CREs are slightly more RC bright than what would be expected from a linear extrapolation. We studied the ratio R of radio to FUV/MIR-based integrated SFR as a function of global galaxy parameters and found no clear correlation. This suggests that we can use RC emission as a universal star formation tracer for galaxies with a similar degree of accuracy as other tracers, if we restrict ourselves to global or azimuthally averaged measurements. We can reconcile our finding of an almost linear RC-SFR relation and sub-linear resolved (on 1 kpc scale) RC-Σ{sub SFR} relation by proposing a non-linear magnetic field-SFR relation, B∝SFR{sub hyb}{sup 0.30±0.02}, which holds both globally and locally.

79 ASTRONOMY AND ASTROPHYSICS↗

AXIS: An instrument for imaging Compton radiographs using the Advanced Radiography Capability on the NIF

Compton radiography is an important diagnostic for Inertial Confinement Fusion (ICF), as it provides a means to measure the density and asymmetries of the DT fuel in an ICF capsule near the time of peak compression. The AXIS instrument (ARC (Advanced Radiography Capability) X-ray Imaging System) is a gated detector in development for the National Ignition Facility (NIF), and will initially be capable of recording two Compton radiographs during a single NIF shot. The principal reason for the development of AXIS is the requirement for significantly improved detection quantum efficiency (DQE) at high x-ray energies. AXIS will be the detector for Compton radiography driven by the ARC laser, which will be used to produce Bremsstrahlung X-ray backlighter sources over the range of 50 keV–200 keV for this purpose. It is expected that AXIS will be capable of recording these high-energy x-rays with a DQE several times greater than other X-ray cameras at NIF, as well as providing a much larger field of view of the imploded capsule. AXIS will therefore provide an image with larger signal-to-noise that will allow the density and distribution of the compressed DT fuel to be measured with significantly greater accuracy as ICF experiments are tuned for ignition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanical characterization of the Varian Exact-arm and R-arm support systems for eight aS500 electronic portal imaging devices

Purpose: The aim of this study is to compare the positioning accuracy at different gantry angles of two electronic portal imaging devices (EPIDs) support arm systems by using EPID difference images as a measure for displacement. This work presents a comparison of the mechanical performance of eight Varian aS500 (Varian Medical Systems, Palo Alto, CA) EPIDs, mounted using either the Varian Exact-arm or R-arm. Methods: The mechanical performance of the two arm systems was compared by investigating the variation in sensitivity with gantry angle, both before and after the EPID position was adjusted after gantry rotation. Positional errors were investigated by subtracting images from a reference image taken at gantry 0 deg., and the amplitude of the peaks and troughs at the field edges for longitudinal (radial) and lateral (transverse) profiles across the resulting image was related to the distance of displacement. Calibration curves based on a pixel-by-pixel shift were generated for each EPID and the Varian hand pendant accuracy was compared to the calibration data. Results: The response of the EPIDs was found to change with gantry rotation, with the largest difference at 180 deg. The Exact-arm was found to correct well for any displacement, while the R-arm tended to overcorrect following repositioning using the hand pendant. The calibration curves were consistent within each set of matched linacs, and the hand pendant accuracy was similar for both arm systems, although generally in different directions. With respect to gantry rotation effects, the mechanical performance of the Exact-arm systems was found to be much better than that of the R-arm systems. At gantry positions 90 deg., 270 deg., and 180 deg. the average misalignment in the longitudinal direction was +4.2{+-}0.2, +1.8{+-}1.6, and +7.4{+-}0.5 mm for the R-arms, and +2.9{+-}0.2, +2.1{+-}0.8, and +4.9{+-}0.7 mm for the Exact-arms. In the lateral direction the average positional errors were +2.1{+-}0.4, -4.7{+-}0.4, and -2.5{+-}0.5 mm for the R-arms, and -0.3{+-}0.3, -0.5{+-}0.3, and -0.4{+-}0.2 mm for the Exact-arms. The hand pendant correction had minimal impact in the lateral direction for both arm systems. However in the longitudinal direction the mean errors for the R-arms were +3.4{+-}0.7, +1.5{+-}0.6, and +4.6{+-}0.7 mm at gantry angles 90 deg., 270 deg., and 180 deg., and the equivalent Exact-arm errors were +0.9{+-}0.3, +1.2{+-}0.3, and +1.9{+-}0.9 mm, respectively. Conclusions: The performance of the EPIDs demonstrate that the Exact-arm system provides a more reproducible position and better agreement with the EPID position as indicated on the EPID pendant at all gantry angles than the R-arm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effective point of measurement of ionization chambers and the build-up anomaly in MV x-ray beams

A precision experimental investigation of the effective point of measurement (EPOM) of ion chambers in megavoltage beams has been carried out. A one-dimensional scanning phantom system was developed with an overall accuracy in the positioning of a chamber of better than 0.15 mm. Depth-dose data were acquired for a 25 MV beam from an Elekta Precise linac (field sizes of 10x10 cm and 25x25 cm) for measurement depths in the range 0.6-6 cm. The results confirmed the Monte Carlo calculations of an earlier theoretical investigation by Kawrakow [Med. Phys. 33, 1829-1839 (2006)] that the standard shift for cylindrical chambers, recommended in dosimetry protocols of -0.6r (where r is the internal radius of the cavity), is incorrect. A wide range of ion chambers were investigated and it was found that errors of up to 1.4 mm could occur for certain chamber designs (although typical errors for common chambers were around 0.5 mm). A comparison between measurements and Monte Carlo simulations showed that once the correct EPOM is used, the details of the linac geometry are correct, and the parameters of the electron beam striking the bremsstrahlung target have been adequately determined, the EGSnrc Monte Carlo package is capable of reproducing the experimental data to 0.2 mm or better. The investigation also confirmed that for the highest accuracy depth-dose curves in megavoltage photon beams one should use a well-guarded parallel-plate ion chamber. Three chamber designs were tested here and found to be satisfactory--the Scanditronix-Wellhoefer NACP-02, PTW Roos and Exradin All.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and construction of the 1{sup st} proton CT scanner

This paper discusses the design and operation of the 1{sup st} proton CT scanner for 3D imaging. Reduction of proton range uncertainties and improved dose accuracy in the patient for treatment planning are central goals. A central CT slice acquired by reconstruction of 134 million proton tracks through a 14 cm spherical polystyrene phantom with high and low density inserts is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PADÉ APPROXIMANTS FOR THE EQUATION OF STATE FOR RELATIVISTIC HYDRODYNAMICS BY KINETIC THEORY

A two-point Padé approximant (TPPA) algorithm is developed for the equation of state (EOS) for relativistic hydrodynamic systems, which are described by the classical Maxwell–Boltzmann statistics and the semiclassical Fermi–Dirac statistics with complete degeneracy. The underlying rational function is determined by the ratios of the macroscopic state variables with various orders of accuracy taken at the extreme relativistic limits. The nonunique TPPAs are validated by Taub's inequality for the consistency of the kinetic theory and the special theory of relativity. The proposed TPPA is utilized in deriving the EOS of the dilute gas and in calculating the specific heat capacity, the adiabatic index function, and the isentropic sound speed of the ideal gas. Some general guidelines are provided for the application of an arbitrary accuracy requirement. The superiority of the proposed TPPA is manifested in manipulating the constituent polynomials of the approximants, which avoids the arithmetic complexity of struggling with the modified Bessel functions and the hyperbolic trigonometric functions arising from the relativistic kinetic theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-432: A Rapid and Comprehensive Procedure for Daily Proton QA

Purpose: The objective is to develop a rapid and comprehensive daily QA procedure implemented at the S. Lee Kling Proton Therapy Center at Barnes-Jewish Hospital. Methods: A scribed phantom with imbedded fiducials is used for checking lasers accuracy followed by couch isocentricity and for X-ray imaging congruence with isocenter. A Daily QA3 device (Sun Nuclear, FL) was used to check output, range and profiles. Five chambers in the central region possess various build-ups. After converting the thickness of the inherent build-ups into water equivalent thickness (WET) for proton, range of any beam can be checked with additional build-up on the Daily QA3 device. In our procedure, 3 beams from 3 bands (large, small and deep) with nominal range of 20 cm are checked daily. 17cm plastic water with WET of 16.92cm are used as additional build-up so that four chambers sit on the SOBP plateau at various depths and one sit on the distal fall off. Reading from the five chambers are fitted to an error function that has been parameterized to match the SOBP with the same nominal range. Shifting of the error function to maximize the correlation between measurements and the error function is deemed as the range shift from the nominal value. Results: We have found couch isocentricity maintained over 180 degrees. Imaging system exhibits accuracy in regard to imaging and mechanical isocenters. Ranges are within 1mm accuracy from measurements in water tank, and sensitive to change of sub-millimeter. Data acquired since the start of operation show outputs, profiles and range stay within 1% or 1mm from baselines. The whole procedure takes about 40 minutes. Conclusion: Taking advantage of the design of Daily QA3 device turns the device originally designed for photon and electron into a comprehensive and rapid tool for proton daily QA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo based, patient-specific RapidArc QA using Linac log files

Purpose: A Monte Carlo (MC) based QA process to validate the dynamic beam delivery accuracy for Varian RapidArc (Varian Medical Systems, Palo Alto, CA) using Linac delivery log files (DynaLog) is presented. Using DynaLog file analysis and MC simulations, the goal of this article is to (a) confirm that adequate sampling is used in the RapidArc optimization algorithm (177 static gantry angles) and (b) to assess the physical machine performance [gantry angle and monitor unit (MU) delivery accuracy]. Methods: Ten clinically acceptable RapidArc treatment plans were generated for various tumor sites and delivered to a water-equivalent cylindrical phantom on the treatment unit. Three Monte Carlo simulations were performed to calculate dose to the CT phantom image set: (a) One using a series of static gantry angles defined by 177 control points with treatment planning system (TPS) MLC control files (planning files), (b) one using continuous gantry rotation with TPS generated MLC control files, and (c) one using continuous gantry rotation with actual Linac delivery log files. Monte Carlo simulated dose distributions are compared to both ionization chamber point measurements and with RapidArc TPS calculated doses. The 3D dose distributions were compared using a 3D gamma-factor analysis, employing a 3%/3 mm distance-to-agreement criterion. Results: The dose difference between MC simulations, TPS, and ionization chamber point measurements was less than 2.1%. For all plans, the MC calculated 3D dose distributions agreed well with the TPS calculated doses (gamma-factor values were less than 1 for more than 95% of the points considered). Machine performance QA was supplemented with an extensive DynaLog file analysis. A DynaLog file analysis showed that leaf position errors were less than 1 mm for 94% of the time and there were no leaf errors greater than 2.5 mm. The mean standard deviation in MU and gantry angle were 0.052 MU and 0.355 deg., respectively, for the ten cases analyzed. Conclusions: The accuracy and flexibility of the Monte Carlo based RapidArc QA system were demonstrated. Good machine performance and accurate dose distribution delivery of RapidArc plans were observed. The sampling used in the TPS optimization algorithm was found to be adequate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗