Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Nanoscopium: a Scanning Hard X-ray Nanoprobe Beamline at Synchrotron Soleil

Nanoscopium is the single scanning hard X-ray nano-probe beamline planned at SOLEIL. This {approx}155 m long beamline will fully exploit the high brilliance and coherence characteristics of the X-ray beam both for diffraction limited focusing and for contrast formation. It will offer the most advanced imaging techniques in multimodal mode and will be a research tool for a wide user community working in the fields of earth-, environmental-, and life-sciences. The different {mu}-{mu}nano-probe techniques offered by the beamline will permit elemental mapping at trace (ppm) levels (scanning XRF), speciation mapping (XANES), phase gradient mapping (scanning differential phase contrast), and density-contrast based imaging of internal structures (coherent diffraction imaging) in the 30 nm to 1 {mu}m spatial resolution range, also in ''in situ conditions''. Nanoscopium will cover the 5-20 keV energy range. The stability of the nanobeam will be ensured by horizontally reflecting beamline optics (a sagitally and a tangentially pre-focusing mirror, horizontally reflecting monochromators) in front of the overfilled secondary source. Trade-off between high energy resolution ({Delta}E/E{approx}10{sup -4}) and high flux (10{sup 11} ph/s with {Delta}E/E{approx}10{sup -2}) will be achieved by two interchangeable monochromators (a double crystal and a double multilayer one). KB mirror and FZP lenses will be used as focusing devices. The beamline is in the design and construction phase. It is foreseen to be open for users at the beginning of 2013.

43 PARTICLE ACCELERATORS↗

A study of ignition phenomena of bulk metals by radiant heating

Early research on combustion of metals was motivated by the knowledge of the large heat release and corresponding high temperatures associated with metal-oxygen reactions. The advent of space flight brought about an increased interest in the ignition and combustion of metallic particles as additives in solid rocket propellants. More recently, attention has been given to the flammability properties of bulk, structural metals due to the number of accidental explosions of metal components in high-pressure oxygen systems. The following work represents a preliminary study that is part of a broader research effort aimed at providing further insight into the phenomena of bulk metal combustion by looking at the effects of gravity on the ignition behavior of metals. The scope of this preliminary experimental study includes the use of a non-coherent, continuous radiation ignition source, the measurement of temperature profiles of a variety of metals and a qualitative observation of the ignition phenomena at normal gravity. The specific objectives of the investigation include: (1) a feasibility study of the use of a continuous radiation source for metal ignition; (2) testing and characterization of the ignition behavior of a variety of metals; and (3) building a preliminary experimental database on ignition of metals under normal gravity conditions.

Branch, Melvin C.↗

Measurements of excitation functions and photoneutron cross sections of 96,98,99,104 Ru and 100 Mo

Photoneutron cross sections were extracted for isotopes of ruthenium and molybdenum on natural abundance targets via a reduced chi-squared analysis on excitation functions, or activation yields, as function of electron beam energy. Bremsstrahlung photons were produced via an electron linear accelerator and a tungsten radiator at the Idaho Accelerator Center. A total of 16 irradiations were performed with electron beam energies ranging from approximately 8 MeV to 23 MeV. Induced radioactivity was measured using a high purity germanium detector. The cross sections were extracted assuming a three parameter Lorentzian fit with a smooth truncated rise at reaction threshold.

07 - ISOTOPES AND RADIATION SOURCES↗

Time evolution of bremsstrahlung and ion production of an electron cyclotron resonance ion source

Bremsstrahlung radiation measurement is one of the most commonly used plasma diagnostics methods. Most of the bremsstrahlung measurements with electron cyclotron resonance (ECR) ion sources have been performed in continuous operation mode yielding information only on the steady state bremsstrahlung emission. This article describes the results of bremsstrahlung and ion current measurement with the JYFL 14 GHz ECRIS operated in pulsed mode. The experiments reveal information about the bremsstrahlung radiation in plasma conditions before reaching the equilibrium. The time scale of bremsstrahlung production is compared to ion production time scale for different charge states. The bremsstrahlung data is presented with 2 millisecond time intervals as a function of neutral gas pressure and microwave power. Data from hundreds of microwave pulses is combined in order to have a sufficient amount of events at each time step. The relevant plasma physics phenomena during both, the leading and the trailing edge of the RF pulse, are discussed.

43 PARTICLE ACCELERATORS↗

Achieving Vibration Stability of the NSLS-II Hard X-ray Nanoprobe Beamline

The hard x-ray nanoprobe (HXN) beamline of the National Synchrotron Light Source II (NSLS-II) requires high levels of stability in order to achieve the desired instrument resolution. To ensure that the design of the endstation helps meet the stringent criteria and that natural and cultural vibration is mitigated both passively and actively, a comprehensive study complimentary to the design process has been undertaken. Vibration sources that have the potential to disrupt sensitive experiments such as wind, traffic, and NSLS II operating systems have been studied using state-of-the-art simulations and an array of field data. Further, final stage vibration isolation principles have been explored.

07 ISOTOPE AND RADIATION SOURCES↗

Thermal Performance Analysis of a Geologic Borehole Repository

The Brazilian Nuclear Research Institute (IPEN) proposed a design for the disposal of Disused Sealed Radioactive Sources (DSRS) based on the IAEA Borehole Disposal of Sealed Radioactive Sources (BOSS) design that would allow the entirety of Brazil’s inventory of DSRS to be disposed in a single borehole. The proposed IPEN design allows for 170 waste packages (WPs) containing DSRS (such as Co-60 and Cs-137) to be stacked on top of each other inside the borehole. The primary objective of this work was to evaluate the thermal performance of a conservative approach to the IPEN proposal with the equivalent of two WPs and two different inside configurations using Co-60 as the radioactive heat source. The current WP configuration (heterogeneous) for the IPEN proposal has 60% of the WP volume being occupied by a nuclear radioactive heat source and the remaining 40% as vacant space. The second configuration (homogeneous) considered for this project was a homogeneous case where 100% of the WP volume was occupied by a nuclear radioactive heat source. The computational models for the thermal analyses of the WP configurations with the Co-60 heat source considered three different cooling mechanisms (conduction, radiation, and convection) and the effect of mesh size on the results from the thermal analysis. The results of the analyses yielded maximum temperatures inside the WPs for both of the WP configurations and various mesh sizes. The heterogeneous WP considered the cooling mechanisms of conduction, convection, and radiation. The temperature results from the heterogeneous WP analysis suggest that the model is cooled predominantly by conduction with effect of radiation and natural convection on cooling being negligible. From the thermal analysis comparing the two WP configurations, the results suggest that either WP configuration could be used for the design. The mesh sensitivity results verify the meshes used, and results obtained from the thermal analyses were close to being independent of mesh size. The results from the computational case and analytically-calculated case for the homogeneous WP in benchmarking were almost identical, which indicates that the computational approach used here was successfully verified by the analytical solution.

07 ISOTOPE AND RADIATION SOURCES↗

On the use of HDR {sup 60}Co source with the MammoSite Radiation Therapy System

This work summarizes Monte Carlo results in order to evaluate the potential of using HDR {sup 60}Co sources in accelerated partial breast irradiation (APBI) with the MammoSite applicator. Simulations have been performed using the MCNP5 Monte Carlo Code, in simple geometries comprised of two concentric spheres; the internal consisting of selected concentrations, C, of a radiographic contrast solution in water (Omnipaque 300) to simulate the MammoSite balloon and the external consisting of water to simulate surrounding tissue. The magnitude of the perturbation of delivered dose due to the radiographic contrast medium used in the MammoSite applicator is calculated. At the very close vicinity of the balloon surface, a dose build-up region is observed, which leads to a dose overestimation by the treatment planning system (TPS) which depends on Omnipaque 300 solution concentration (and is in order of 2.3%, 3.0%, and 4.5%, respectively, at 1 mm away from the balloon - water interface, for C=10%, 15%, and 20%). However, dose overestimation by the TPS is minimal for points lying at the prescription distance (d=1 cm) or beyond, for all simulated concentrations and radii of MammoSite balloon. An analytical estimation of the integral dose outside the CTV in the simple geometries simulated shows that dose to the breast for MammoSite applications is expected to be comparable using HDR {sup 60}Co and {sup 192}Ir sources, and higher than that for {sup 169}Yb. The higher enegies of {sup 60}Co sources result to approximately twice radiation protection requirements as compared to {sup 169}Ir sources. However, they allow for more accurate dosimetry calculation with currently used treatment planning algorithms for {sup 60}Co sources, compared to {sup 169}Ir.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The origin of infrared emission from the nucleus of NGC 1068

Recent infrared observational results for the nucleus of the Seyfert galaxy NGC 1068 are reviewed and analyzed in terms consistent with information available at other wavelengths. It is concluded that the infrared and optical data imply that more than 85 percent of the infrared emission at 10 microns is radiation from dust grains in the nucleus. Observed reddening of spectral lines implies geometrical optical depths at visual wavelengths of about 7-15 if the nuclear dust cloud is approximately spherically symmetric. The dust grains emitting the infrared radiation could be silicates with a 10-micron optical depth near unity, but this identification is not uniquely established. The grains are heated radiatively by an underlying source or sources of radiation also responsible for ionizing the emission-line-producing gas. The underlying source could be nonthermal, or it could be a hot plasma. Physical constraints on each of these models are derived.

Jones, T. W.↗

Evaluation of Antitumor Efficiency of High Intensity Radiation {sup 169}Yb Source on Experimental Sarcoma M-1

Rats with sarcoma M-1 were exposed to high dose rate irradiation with {sup 169}Yb source. In 25 days after introduction of a trocar with sealed capsule with {sup 169}Yb source into the tumor, complete tumor regression was observed in 70% animals. The results suggest feasibility of using {sup 169}Yb source for high-dose rate brachytherapy and development of the personalized medicine approaches.

60 APPLIED LIFE SCIENCES↗

MicroRT - Small animal conformal irradiator

A novel small animal conformal radiation therapy system has been designed and prototyped: MicroRT. The microRT system integrates multimodality imaging, radiation treatment planning, and conformal radiation therapy that utilizes a clinical {sup 192}Ir isotope high dose rate source as the radiation source (teletherapy). A multiparameter dose calculation algorithm based on Monte Carlo dose distribution simulations is used to efficiently and accurately calculate doses for treatment planning purposes. A series of precisely machined tungsten collimators mounted onto a cylindrical collimator assembly is used to provide the radiation beam portals. The current design allows a source-to-target distance range of 1-8 cm at four beam angles: 0 deg. (beam oriented down), 90 deg., 180 deg., and 270 deg. The animal is anesthetized and placed in an immobilization device with built-in fiducial markers and scanned using a computed tomography, magnetic resonance, or positron emission tomography scanner prior to irradiation. Treatment plans using up to four beam orientations are created utilizing a custom treatment planning system--microRTP. A three-axis computer-controlled stage that supports and accurately positions the animals is programmed to place the animal relative to the radiation beams according to the microRTP plan. The microRT system positioning accuracy was found to be submillimeter. The radiation source is guided through one of four catheter channels and placed in line with the tungsten collimators to deliver the conformal radiation treatment. The microRT hardware specifications, the accuracy of the treatment planning and positioning systems, and some typical procedures for radiobiological experiments that can be performed with the microRT device are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two-Flux Green's Function Analysis for Transient Spectral Radiation in a Composite

An analysis is developed for obtaining transient temperatures in a two-layer semitransparent composite with spectrally dependent properties. Each external boundary of the composite is subjected to radiation and convection. The two-flux radiative transfer equations are solved by deriving a Green's function. This yields the local radiative heat source needed to numerically solve the transient energy equation. An advantage of the two-flux method is that isotropic scattering is included without added complexity. The layer refractive indices are larger than one. This produces internal reflections at the boundaries and the internal interface; the reflections are assumed diffuse. Spectral results using the Green's function method are verified by comparing with numerical solutions using the exact radiative transfer equations. Transient temperature distributions are given to illustrate the effect of radiative heating on one side of a composite with external convective cooling. The protection of a material from incident radiation is illustrated by adding scattering to the layer adjacent to the radiative source.

Siegel, Robert↗

The use of directional interstitial sources to improve dosimetry in breast brachytherapy

The purposes of this study were to investigate the feasibility of improving dosimetry with temporary low-dose-rate (LDR) multicatheter breast implants using directional {sup 125}I (iodine) interstitial sources and to provide a comparison of a patient treatment plan to that achieved by conventional high-dose-rate (HDR) interstitial breast brachytherapy. A novel {sup 125}I source emitting radiation in a specified direction has been developed. The directional sources contain an internal radiation shield that greatly reduces the intensity of radiation in the shielded direction. The sources have a similar dose distribution to conventional nondirectional sources on the unshielded side. The treatment plan for a patient treated with HDR interstitial brachytherapy with {sup 192}Ir (iridium) was compared with a directional {sup 125}I treatment plan using the same data set. Several dosimetric parameters are compared including target volume coverage, volume receiving 50%, 100%, and 150% of the prescription dose (V50, V100, and V150, respectively), dose homogeneity index (DHI), and the skin surface areas receiving 30%, 50%, and 80% of the prescription dose (S30, S50, and S80, respectively). The HDR and LDR prescription doses were 34 Gy in ten fractions delivered over five days and 45 Gy in 108 h, respectively. Similar and excellent target volume coverage was achieved by both directional LDR and HDR plans (99.2% and 97.5%, respectively). For a 170 cm{sup 3} target volume, the dosimetric parameters were similar for LDR and HDR: DHI was 0.82 in both cases, V100 was 214.4 cm{sup 3} and 225.7 cm{sup 3}, and V150 was 39.1 cm{sup 3} and 40.4 cm{sup 3}, respectively. However, with directional LDR, significant reductions in skin dose were achieved: S30 was reduced from 100.6 to 62.5 cm{sup 2}, S50 from 50.6 to 16.1 cm{sup 2}, and S80 from 2 cm{sup 2} to zero. The reduction in V50 for the whole breast was more than 100 cm{sup 3} (386.1 cm{sup 3} for LDR versus 489.2 cm{sup 3} for HDR). In this case study, compared with HDR, directional interstitial LDR {sup 125}I sources allow similar dose coverage to the subcutaneous target volume while lowering the skin dose due to a more conformal dose distribution and quicker falloff beyond the target. The improved dose distribution provided by directional interstitial brachytherapy might enable partial breast treatment to tumors closer to the skin or chest wall or in relatively small breasts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of noise radiated from convected ring sources in coaxial dual flow. Part 1: The noise from unheated jets

The effects of flight on sound radiated from embedded, uncorrelated ring sources convecting along the midst of the primary and the secondary streams of a coaxial dual flow which emerges from a moving nozzle into the ambience are studied. Cold jets are examined. The problem is posed as a double vortex-sheet flow model which involves deliberate suppression of inherent instabilities of the flow and is formulated, as a linear problem, in terms of the combined contributions of two independent uncorrelated quadrupole-type ring sources, the one convecting in the primary flow representing the sources generated due to the interaction at the primary/secondary interface and the other convecting in the secondary flow representing the sources generated due to the interaction at the secondary/ambient interface. The analysis shows that the effects of flight induce (1) amplication of noise in the forward quadrant, (2) reduction of noise in the aft quadrant and (3) absolutely no impact on radiation of noise at Theta = 90 deg to the jet axis.

Dash, R.↗

Quantifying the range of the dust direct radiative effect due to source mineralogy uncertainty

The large uncertainty in the mineral dust direct radiative effect (DRE) hinders projections of future climate change due to anthropogenic activity. Resolving modeled dust mineral speciation allows for spatially and temporally varying refractive indices consistent with dust aerosol composition. Here, for the first time, we quantify the range in dust DRE at the top of the atmosphere (TOA) due to current uncertainties in the surface soil mineralogical content using a dust mineral-resolving climate model. We propagate observed uncertainties in soil mineral abundances from two soil mineralogy atlases along with the optical properties of each mineral into the DRE and compare the resultant range with other sources of uncertainty across six climate models. The shortwave DRE responds region-specifically to the dust burden depending on the mineral speciation and underlying shortwave surface albedo: positively when the regionally averaged annual surface albedo is larger than 0.28 and negatively otherwise. Among all minerals examined, the shortwave TOA DRE and single scattering albedo at the 0.44–0.63 µm band are most sensitive to the fractional contribution of iron oxides to the total dust composition. The global net (shortwave plus longwave) TOA DRE is estimated to be within −0.23 to +0.35 W/sq. m. Approximately 97 % of this range relates to uncertainty in the soil abundance of iron oxides. Representing iron oxide with solely hematite optical properties leads to an overestimation of shortwave DRE by +0.10 W/sq. m at the TOA, as goethite is not as absorbing as hematite in the shortwave spectrum range. Our study highlights the importance of iron oxides to the shortwave DRE: they have a disproportionally large impact on climate considering their small atmospheric mineral mass fractional burden (∼2 %). An improved description of iron oxides, such as those planned in the Earth Surface Mineral Dust Source Investigation (EMIT), is thus essential for more accurate estimates of the dust DRE.

mineral dust↗

Cryogenic Field Measurement of Pr{sub 2}Fe{sub 14}B Undulator and Performance Enhancement Options at the NSLS-II

Short period (14.5mm) hybrid undulator arrays composed of Praseodymium Iron Boron (Pr{sub 2}Fe{sub 14}B) magnets (CR53, NEOMAX, Inc.) and vanadium permendur poles have been fabricated at Brookhaven National Laboratory. Unlike Neodymium Iron Boron (Nd{sub 2}Fe{sub 14}B) magnets which exhibit spin reorientation at a temperatures below 150 K, PrFeB arrays monotonically increase performance with lower operating temperature. It opens up the possibility for use in operating a cryo-permanent magnet undulator (CPMU) in the range of 40 K to 60 K where very efficient cryocoolers are available. Magnetic flux density profiles were measured at various temperature ranges from room temperature down to liquid helium (LHe) using the Vertical Testing Facility (VTF) at the National Synchrotron Light Source-II (NSLS-II). Temperature variations of phase error have been characterized. In addition, we examined the use of textured Dysprosium (Dy) poles to replace permendur poles to obtain further improvement in performance.

43 PARTICLE ACCELERATORS↗

Saturn Neutron Exosphere as Source for Inner and Innermost Radiation Belts

Energetic proton and electron measurements by the ongoing Cassini orbiter mission are expanding our knowledge of the highest energy components of the Saturn magnetosphere in the inner radiation belt region after the initial discoveries of these belts by the Pioneer 11 and Voyager 2 missions. Saturn has a neutron exosphere that extends throughout the magnetosphere from the cosmic ray albedo neutron source at the planetary main rings and atmosphere. The neutrons emitted from these sources at energies respectively above 4 and 8 eV escape the Saturn system, while those at lower energies are gravitationally bound. The neutrons undergo beta decay in average times of about 1000 seconds to provide distributed sources of protons and electrons throughout Saturn's magnetosphere with highest injection rates close to the Saturn and ring sources. The competing radiation belt source for energetic electrons is rapid inward diffusion and acceleration of electrons from the middle magnetosphere and beyond. Minimal losses during diffusive transport across the moon orbits, e.g. of Mimas and Enceladus, and local time asymmetries in electron intensity, suggest that drift resonance effects preferentially boost the diffusion rates of electrons from both sources. Energy dependences of longitudinal gradient-curvature drift speeds relative to the icy moons are likely responsible for hemispheric differences (e.g., Mimas, Tethys) in composition and thermal properties as at least partly produced by radiolytic processes. A continuing mystery is the similar radial profiles of lower energy (<10 MeV) protons in the inner belt region. Either the source of these lower energy protons is also neutron decay, but perhaps alternatively from atmospheric albedo, or else all protons from diverse distributed sources are similarly affected by losses at the moon' orbits, e.g. because the proton diffusion rates are extremely low. Enceladus cryovolcanism, and radiolytic processing elsewhere on the icy moon and ring surfaces, are additional sources of protons via ionization and charge exchange from breakup of water molecules. But one must then account somehow for local acceleration to the observed keV-MeV energies, since moon sweeping and E-ring absorption would remove protons diffusing inward from the middle magnetosphere. Although the main rings block further inward diffusion from the inner radiation belts, the exospheric neutron-decay source, combined with much slower diffusion of protons relative to electrons, may produce an innermost radiation belt in the gap between the upper atmosphere and the D-ring. This innermost belt will first be explored in-situ during the final proximal orbits of the Cassini mission.

Cooper, John↗

Automated management of radioactive sources in Saudi Arabia

For usage of radioactive substances, any facility has to register and take license from relevant authority of the country in which such facility is operating. In the Kingdom of Saudi Arabia (KSA), the authority for managing radioactive sources and providing licenses to organizations for its usage is the National Center of Radiation Protection (NCRP). This paper describes the system that automates registration and licensing process of the National Center of Radiation Protection. To provide 24×7 accesses to all the customers of NCRP, system is developed as web-based application that provide facility to online register, request license, renew license, check request status, view historical data and reports etc. and other features are provided as Electronic Services that would be accessible to users via internet. The system also was designed to streamline and optimize internal operations of NCRP besides providing ease of access to its customers by implementing a defined workflow through which every registration and license request will be routed. In addition to manual payment option, the system would also be integrated with SADAD (online payment system) that will avoid lengthy and cumbersome procedures associated with manual payment mechanism. Using SADAD payment option license fee could be paid through internet/ATM machine or branch of any designated bank, Payment will be instantly notified to NCRP hence delay in funds transfer and verification of invoice could be avoided, SADAD integration is discussed later in the document.

07 ISOTOPE AND RADIATION SOURCES↗