Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

High spatial and temporal resolution charge exchange recombination spectroscopy on the HL-2A tokamak

A 32/64-channel charge exchange recombination spectroscopy (CXRS) diagnostic system is developed on the HL-2A tokamak (R = 1.65 m, a = 0.4 m), monitoring plasma ion temperature and toroidal rotation velocity simultaneously. A high throughput spectrometer (F/2.8) and a pitch-controlled fiber bundle enable the temporal resolution of the system up to 400 Hz. The observation geometry and an optimized optic system enable the highest radial resolution up to ~1 cm at the plasma edge. The CXRS system monitors the carbon line emission (C VI, n = 8–7, 529.06 nm) whose Doppler broadening and Doppler shift provide ion temperature and plasma rotation velocity during the neutral beam injection. The composite CX spectral data are analyzed by the atomic data and analysis structure charge exchange spectroscopy fitting (ADAS CXSFIT) code. First experimental results are shown for the case of HL-2A plasmas with sawtooth oscillations, electron cyclotron resonance heating, and edge transport barrier during the high-confinement mode (H-mode)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A cryogenically cooled, ultra-high-energy-resolution, trap-based positron beam

A technique is described to produce a pulsed, magnetically guided positron beam with significantly improved beam characteristics over those available previously. A pulsed, room-temperature positron beam from a buffer gas trap is used as input to a trap that captures the positrons, compresses them both radially and axially, and cools them to 50 K on a cryogenic CO buffer gas before ejecting them as a pulsed beam. The total energy spread of the beam formed using this technique is 6.9 ± 0.7 meV FWHM, which is a factor of ∼5 better than the previous state-of-the-art, while simultaneously having sub-microsecond temporal resolution and millimeter spatial resolution. Possible further improvements in beam quality are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Note: High temporal resolution characterization of gating response time

Purpose: Low temporal latency between a gating ON/OFF signal and the LINAC beam ON/OFF during respiratory gating is critical for patient safety. Here the authors describe a novel method to precisely measure gating lag times at high temporal resolutions. Methods: A respiratory gating simulator with an oscillating platform was modified to include a linear potentiometer for position measurement. A photon diode was placed at linear accelerator isocenter for beam output measurement. The output signals of the potentiometer and diode were recorded simultaneously at 2500 Hz with an analog to digital converter for four different commercial respiratory gating systems. The ON and OFF of the beam signal were located and compared to the expected gating window for both phase and position based gating and the temporal lag times extracted. Results: For phase based gating, a real-time position management (RPM) infrared marker tracking system with a single camera and a RPM system with a stereoscopic camera were measured to have mean gate ON/OFF lag times of 98/90 and 86/44 ms, respectively. For position based gating, an AlignRT 3D surface system and a Calypso magnetic fiducial tracking system were measured to have mean gate ON/OFF lag times of 356/529 and 209/60 ms, respectively. Conclusions: Temporal resolution of the method was high enough to allow characterization of individual gate cycles and was primary limited by the sampling speed of the data recording device. Significant variation of mean gate ON/OFF lag time was found between different gating systems. For certain gating devices, individual gating cycle lag times can vary significantly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-CD-207B-03: How to Quantify Temporal Resolution in X-Ray MDCT Imaging?

Purpose: In modern CT scanners, a quantitative metric to assess temporal response, namely, to quantify the temporal resolution (TR), remains elusive. Rough surrogate metrics, such as half of the gantry rotation time for single source CT, a quarter of the gantry rotation time for dual source CT, or measurements of motion artifact’s size, shape, or intensity have previously been used. In this work, a rigorous framework which quantifies TR and a practical measurement method are developed. Methods: A motion phantom was simulated which consisted of a single rod that is in motion except during a static period at the temporal center of the scan, termed the TR window. If the image of the motion scan has negligible motion artifacts compared to an image from a totally static scan, then the system has a TR no worse than the TR window used. By repeating this comparison with varying TR windows, the TR of the system can be accurately determined. Motion artifacts were also visually assessed and the TR was measured across varying rod motion speeds, directions, and locations. Noiseless fan beam acquisitions were simulated and images were reconstructed with a short-scan image reconstruction algorithm. Results: The size, shape, and intensity of motion artifacts varied when the rod speed, direction, or location changed. TR measured using the proposed method, however, was consistent across rod speeds, directions, and locations. Conclusion: Since motion artifacts vary depending upon the motion speed, direction, and location, they are not suitable for measuring TR. In this work, a CT system with a specified TR is defined as having the ability to produce a static image with negligible motion artifacts, no matter what motion occurs outside of a static window of width TR. This framework allows for practical measurement of temporal resolution in clinical CT imaging systems. Funding support: GE Healthcare; Conflict of Interest: Employee, GE Healthcare.

60 APPLIED LIFE SCIENCES↗

Aerosol Retrieval from Multiangle Multispectral Photopolarimetric Measurements: Importance of Spectral Range and Angular Resolution

We investigated the importance of spectral range and angular resolution for aerosol retrieval from multiangle photopolarimetric measurements over land. For this purpose, we use an extensive set of simulated measurements for different spectral ranges and angular resolutions and subsets of real measurements of the airborne Research Scanning Polarimeter (RSP) carried out during the PODEX and SEAC4RS campaigns over the continental USA. Aerosol retrievals performed from RSP measurements show good agreement with ground-based AERONET measurements for aerosol optical depth (AOD), single scattering albedo (SSA) and refractive index. Furthermore, we found that inclusion of shortwave infrared bands (1590 and/or 2250 nm) significantly improves the retrieval of AOD, SSA and coarse mode microphysical properties. However, accuracies of the retrieved aerosol properties do not improve significantly when more than five viewing angles are used in the retrieval.

angular resolution↗

The Robust Dynamical Contribution to Precipitation Extremes in Idealized Warming Simulations across Model Resolutions

The impact of the circulation shift under climate warming on the distribution of precipitation extremes and the associated sensitivity to model resolution are investigated using the aquaplanet Community Atmosphere Model CAM3. The response of the probability density function of the precipitation to a uniform SST warming can be interpreted as superimposition of a dynamically induced poleward shift and a thermodynamically induced upward shift toward higher intensities, which give rise to manyfold increase in the frequency of the most extreme categories of the precipitation events at the poleward side of the midlatitude storm track. Meanwhile, the thermodynamic contribution to the intensification of the precipitation extremes is substantially less than expected from the Clausius-Clapeyron relation, implicative of significant change in the vertical structure of the precipitation processes. While coarser resolutions underestimate the dynamical contribution to the increase of precipitation extremes, a modest increase of the equator-to-pole SST warming gradient can have a significant opposite effect.

dynamical↗

Exploring the effects of a nonhydrostatic dynamical core in high-resolution aquaplanet simulations

This study explores the impact of a nonhydrostatic dynamical core in high-resolution regional climate simulations using an aquaplanet framework. The Weather Research and Forecasting (WRF) model is used to conduct simulations with both hydrostatic (H) and nonhydrostatic (NH) solvers at horizontal grid spacings (?x) of 36, 12, and 4 km. The differences between the H and NH simulated precipitation (?P) are notable even at ?x = 12 km in the inter-tropical convergence zone and the transition region to the drier subtropics. At gray-zone grid spacing (12 km and 4 km) over the tropics, ?P is sensitive to whether a cumulus parameterization scheme is used or not. With an idealized Witch of Agnesi land mountain, differences in the precipitation and circulation (vertical velocity) between the H and NH simulations are significant even at ?x = 36 km in the tropics due largely to the strong feedbacks related to moist processes. The differences increase as the model grid spacing and mountain half width (a) are reduced, accompanied by a shift towards a more nonhydrostatic flow regime at a = 24 km. Latent heat release drastically enhances the differences between the NH and H simulations and extends the effect of nonhydrostatic dynamics to a broader region over the mountain and downstream over the tropics. Overall, differences exist between H and NH simulations even at resolutions between 12 and 36 km, but the differences are sensitive to the representations of moist physics and other features such as horizontal diffusion used in the WRF model.

nonhydrostatic dynamics, latent heating, nonhydros↗

High‐Resolution Dynamical Downscaling Ensemble Projections of Future Extreme Temperature Distributions for the United States

Abstract The aim of this study is to examine projections of extreme temperatures over the continental United States (CONUS) for the 21st century using an ensemble of high spatial resolution dynamically downscaled model simulations with different boundary conditions. The downscaling uses the Weather Research and Forecast model at a spatial resolution of 12 km along with outputs from three different Coupled Model Intercomparison Project Phase 5 global climate models that provide boundary conditions under two different future greenhouse gas (GHG) concentration trajectories. The results from two decadal‐length time slices (2045–2054 and 2085–2094) are compared with a historical decade (1995–2004). Probability density functions of daily maximum/minimum temperatures are analyzed over seven climatologically cohesive regions of the CONUS. The impacts of different boundary conditions as well as future GHG concentrations on extreme events such as heat waves and days with temperature higher than 95°F are also investigated. The results show that the intensity of extreme warm temperature in future summer is significantly increased, while the frequency of extreme cold temperature in future winter decreases. The distribution of summer daily maximum temperature experiences a significant warm‐side shift and increased variability, while the distribution of winter daily minimum temperature is projected to have a less significant warm‐side shift with decreased variability. Using “business‐as‐usual” scenario, 5‐day heat waves are projected to occur at least 5–10 times per year in most CONUS and ≥95°F days will increase by 1–2 months by the end of the century.

54 ENVIRONMENTAL SCIENCES↗

Monitoring and Modeling the Rapid Evolution of Earth's Newest Volcanic Island: Hunga Tonga Hunga Ha'apai (Tonga) Using High Spatial Resolution Satellite Observations

We have monitored a newly erupted volcanic island in the Kingdom of Tonga, unofficially known as Hunga Tonga Hunga Ha'apai , by means of relatively frequent high spatial resolution (~50 cm) satellite observations. The new ~1.8 km 2 island formed as a tuff cone over the course of a month-long hydromagmatic eruption in early 2015 in the Tonga-Kermadec volcanic arc. Such ash-dominated eruptions usually produce fragile subaerial landscapes that wash away rapidly due to marine erosion, as occurred nearby in 2009. Our measured rates of erosion are ~0.00256 km 3 /year from derived digital topographic models. Preliminary measurements of the topographic expression of the primary tuff cone over ~30 months suggest a lifetime of ~19 years (and potentially up to 42 years). The ability to measure details of a young island's landscape evolution using satellite remote sensing has not previously been possible at these spatial and temporal resolutions.

47 OTHER INSTRUMENTATION↗

An Idealized Test of the Response of the Community Atmosphere Model to Near‐Grid‐Scale Forcing Across Hydrostatic Resolutions

Abstract A set of idealized experiments are developed using the Community Atmosphere Model (CAM) to understand the vertical velocity response to reductions in forcing scale that is known to occur when the horizontal resolution of the model is increased. The test consists of a set of rising bubble experiments, in which the horizontal radius of the bubble and the model grid spacing are simultaneously reduced. The test is performed with moisture, through incorporating moist physics routines of varying complexity, although convection schemes are not considered. Results confirm that the vertical velocity in CAM is to first‐order, proportional to the inverse of the horizontal forcing scale, which is consistent with a scale analysis of the dry equations of motion. In contrast, experiments in which the coupling time step between the moist physics routines and the dynamical core (i.e., the “physics” time step) are relaxed back to more conventional values results in severely damped vertical motion at high resolution, degrading the scaling. A set of aqua‐planet simulations using different physics time steps are found to be consistent with the results of the idealized experiments.

54 ENVIRONMENTAL SCIENCES↗

High-Resolution Imaging of Cellulose Organization in Cell Walls by Field Emission Scanning Electron Microscopy

Field emission scanning electron microscopy (FESEM) is a powerful tool for analyzing surface structures of biological and nonbiological samples. However, when it is used to study fine structures of nanometer-sized microfibrils of epidermal cell walls, one often encounters tremendous challenges to acquire clear and undistorted images because of two major issues: (1) Preparation of samples suitable for high resolution imaging; due to the delicateness of some plant materials, such as onion epidermal cell walls, many things can happen during sample processing, which subsequently result in damaged samples or introduce artifacts. (2) Difficulties to acquire clear images of samples which are electron-beam sensitive and prone to charging artifacts at magnifications over 100,000×. In this chapter we described detailed procedures for sample preparation and conditions for high-resolution FESEM imaging of onion epidermal cell walls. Lastly, the methods can be readily adapted for other wall materials.

59 BASIC BIOLOGICAL SCIENCES↗

High Spatial Resolution MRI of Cystic Adventitial Disease of the Iliofemoral Vein Communicating with the Hip Joint

Venous cystic adventitial disease (CAD) is an extremely rare entity, and so far less than 20 cases have been described in the literature. Herein, we describe the imaging findings of CAD of iliofemoral vein in a 51-year-old woman who presented with leg swelling with special emphasis on high spatial resolution MRI, which demonstrated communication of the cyst with the hip joint. To our knowledge, this is the first description of high spatial resolution MRI findings in venous CAD supporting a new theory about the pathogenesis of venous CAD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Theoretical Models of Low-Resolution Microwave Rotational Spectra of Ethane- and Propanethiol

Additive modeling of low-resolution microwave spectra of heteroisomeric substituted hydrocarbons produced theoretical spectra of ethanethiol and propanethiol in the range 0–2 THz with maxima at 465 ± 20 and 240 ± 20 GHz. More precise calculations in a narrow frequency band of these ranges used spectral line half-widths of 1.5, 0.8, and 0.5 MHz that modeled conditions in different layers of Earth’s troposphere. The strongest extrema of the low-resolution spectra of the studied molecules were found at 486 ± 5, 446 ± 5, and 436 ± 5 (ethanethiol) and at 257 ± 5, 239 ± 5, and 234 ± 5 GHz (propanethiol). Various aspects of the application of the results were discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of borated scintillator screens for high-resolution neutron imaging

The most commonly used screens for neutron imaging consist of 6 LiF + ZnS. This type of screen yields the highest light output per detected neutron. For high resolution, gadolinium oxysulfide (GOS, Gadox) screens are employed, which have a much higher detection efficiency, but a light output so much lower than LiF + ZnS that measurements are often limited by photon statistics. Historically, screens using boron as a neutron-sensitive material have not been very successful. However, a new preparation method was introduced recently that produces light output higher than Gadox with detection efficiency greater than LiF + ZnS. Measurements of these new borated screens were performed at the NeXT facility at ILL, Grenoble, in comparison to a high resolution Gadox screen.

10B↗

An iris biometric protection scheme using 4D hyperchaotic system and modified equal modulus decomposition in hybrid multi resolution wavelet domain

In this paper, a hybrid iris biometric protection scheme using 4D hyperchaotic system by means of coherent superposition and modified equal modulus decomposition in hybrid multi-resolution wavelet domain is proposed. The 4D hyperchaotic framework is employed for producing the permutation keystream for pixel swap-over mechanism. The hybrid multi-resolution is produced by means of Kronecker product of Walsh transform and fractional Fourier transform of different orders. Fractional orders of the hybrid multiresolution wavelet along with the parameters and initial conditions of the 4D hyperchaotic framework, later fill in as additional keys, thus enhancing the key space of the proposed mechanism. The proposed scheme has nonlinear characteristics and has high robustness against brute-force attack attributable to its enormous key-space. Numerical simulations have been carried out on grayscale images to prove the authenticity and efficacy of the proposed cryptosystem. The functioning of the proposed cryptosystem is investigated against various attacks including special attack. Outcomes display that the proposed iris template protection scheme not only has higher robustness against noise attack but is also unassailable to the iterative transform-based attacks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Technological and optical methods for increasing the spatial resolution of thermochemical laser writing on thin metal films

Various techniques, effects, and factors are examined that enable one to increase the spatial resolution of thermochemical direct laser writing on thin metal films. A few specific conditions of experimental laser processing with the focused beam of a CW green laser are investigated therewith. One of the goals of this work was to find a suitable metal and its thickness that would make it possible to implement the through-oxidation regime. When properly adjusting a value of laser exposure, this regime was found to be very useful for increasing the spatial resolution of the laser writing. This is due to bleaching of an oxidized film near the peak of a focused laser spot. Apart from the experimental results concerning the technology of laser processing of the metal films, in this work, there are also considered some ways of reducing a focused spot size used for the direct laser writing.

36 MATERIALS SCIENCE↗

The impact of positron range on PET resolution, evaluated with phantoms and PHITS Monte Carlo simulations for conventional and non-conventional radionuclides

The increasing interest and availability of non-standard positron-emitting radionuclides has heightened the relevance of radionuclide choice in the development and optimization of new positron emission tomography (PET) imaging procedures, both in preclinical research and clinical practice. Differences in achievable resolution arising from positron range can largely influence application suitability of each radionuclide, especially in small-ring preclinical PET where system blurring factors due to annihilation photon acollinearity and detector geometry are less significant. Here, some resolution degradation can be mitigated with appropriate range corrections implemented during image reconstruction, the quality of which is contingent on an accurate characterization of positron range.

43 PARTICLE ACCELERATORS↗