Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Capillary absorption spectroscopy for high temporal resolution measurements of stable carbon isotopes in soil and plant-based systems

Capillary Absorption Spectroscopy (CAS) is a relatively new analytical technique for performing stable isotope analysis. Here, we demonstrate the utility of CAS by recording and quantifying variation in 13C in controlled and biologically relevant applications. We calibrated CAS system response to increased 13CO2, with an observed ~4‰ increase in measured Δ13C for each 0.03 ppm shift in 13CO2 concentration. We leveraged this calibration to quantify rates of biogeochemical processes using a 13C tracer. For example, we monitored microbial respiration of 13C-glucose within an agricultural soil at 10 s quantification intervals and results demonstrated 8.6% ± 0.4 of added glucose was converted to 13CO2 within 1.5 h of incubation. We expanded the demonstration by adapting a rhizobox to permit continuous monitoring of 13CO2 in a soil (as distinct from plant) headspace to track the timing and quantify respiration rates of fresh plant photosynthate and observed a 3.5 h delay between plant exposure to a13CO2 tracer and the first signs of respiration by soil biota. These experiments highlight CAS is effective in producing high temporal resolution quantification of 13CO2 and demonstrate potential applications.

13CO2↗

Expansion of the Petroleum Refinery Life Cycle Inventory Model (PRELIM) to Support Characterization of a Full Suite of Commonly Tracked Impact Potentials

This study updates the Petroleum Refinery Life Cycle Inventory Model (PRELIM) to provide a more complete gate-to-gate life cycle inventory and to allow for the calculation of a full suite of impact potentials commonly used in life cycle assessment (LCA) studies. We updated the model to add criteria air pollutants, hazardous air pollutants, releases to water, releases to land, and managed wastes reflecting 2014 reported releases and waste management practices using data from the U.S. Environmental Protection Agency Greenhouse Gas Reporting Program, National Emissions Inventory, Discharge Monitoring Reports, and Toxic Release Inventory together with process unit capacities and fuel consumption data from the U.S. Energy Information Administration (U.S. EIA). The expanded version of PRELIM offers users a reliable, transparent, and streamlined tool for estimating the effect of changes in petroleum refineries on LCIA results in the context of policy analysis.

Source record↗

Functional metal–organic frameworks as effective sensors of gases and volatile compounds

Developing efficient sensor materials with superior performance for selective, fast and sensitive detection of gases and volatile organic compounds (VOCs) is essential for human health and environmental protection, through monitoring indoor and outdoor air pollutions, managing industrial processes, controlling food quality and assisting early diagnosis of diseases. Metal–organic frameworks (MOFs) are a unique type of crystalline and porous solid material constructed from metal nodes (metal ions or clusters) and functional organic ligands. They have been investigated extensively for possible use as high performance sensors for the detection of many different gases and VOCs in recent years, due to their large surface area, tunable pore size, functionalizable sites and intriguing properties, such as electrical conductivity, magnetism, ferroelectricity, luminescence and chromism. The high porosity of MOFs allows them to interact strongly with various analytes, including gases and VOCs, thus resulting in easily measurable responses to different physicochemical parameters. Although much of the recent work on MOF-based luminescent sensors have been summarized in several excellent reviews (up to 2018), a comprehensive overview of these materials for sensing gases and VOCs based on chemiresistive, magnetic, ferroelectric, and colorimertic mechanisms is missing. In this review, we highlight the most recent progress in developing MOF sensing and switching materials with an emphasis on sensing mechanisms based on electricity, magnetism, ferroelectricity and chromism. We provide a comprehensive analysis on the MOF–analyte interactions in these processes, which play a key role in the sensing performance of the MOF-based sensors and switches. We discuss in detail possible applications of MOF-based sensing and switching materials in detecting oxygen, water vapor, toxic industrial gases (such as hydrogen sulfide, ammonia, sulfur dioxide, nitrous oxide, carbon oxides and carbon disulfide) and VOCs (such as aromatic and aliphatic hydrocarbons, ketones, alcohols, aldehydes, chlorinated hydrocarbons and N,N'-dimethylformamide). Altogether, this review serves as a timely source of information and provides insight for the future development of advanced MOF materials as next-generation gas and VOC sensors.

36 MATERIALS SCIENCE↗

Coherent control of the isomerization of retinal in bacteriorhodopsin in the high intensity regime

Coherent control protocols provide a direct experimental determination of the relative importance of quantum interference or phase relationships of coupled states along a selected pathway. These effects are most readily observed in the high intensity regime where the field amplitude is sufficient to overcome decoherence effects. The coherent response of retinal photoisomerization in bacteriorhodopsin to the phase of the photoexcitation pulses was examined at fluences of 10{sup 15}- 2.5 x 10{sup 16} photons per square centimeter, comparable to or higher than the saturation excitation level of the S{sub 0}-S{sub 1} retinal electronic transition. At moderate excitation levels of {approx}6 x 10{sup 15} photons/cm{sup 2} (<100 GW/cm{sup 2}), chirping the excitation pulses increases the all-trans to 13-cis isomerization yield by up to 16% relative to transform limited pulses. The reported results extend previous weak-field studies [Prokhorenko et al., Science 313, 1257 (2006)] and further illustrate that quantum coherence effects persist along the reaction coordinate in strong fields even for systems as complex as biological molecules. However, for higher excitation levels of {approx}200 GW/cm{sup 2}, there is a dramatic change in photophysics that leads to multiphoton generated photoproducts unrelated to the target isomerization reaction channel and drastically changes the observed isomerization kinetics that appears, in particular, as a red shift of the transient spectra. These results explain the apparent contradictions of the work by Florean et al.[Proc. Natl. Acad. Sci. U.S.A. 106, 10896 (2009)] in the high intensity regime. We are able to show that the difference in observations and interpretation is due to artifacts associated with additional multiphoton-induced photoproducts. At the proper monitoring wavelengths, coherent control in the high intensity regime is clearly observable. The present work highlights the importance of conducting coherent control experiments in the low intensity regime to access information on quantum interference effects along specific reaction coordinates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Luminescence quenching of conductive Si nanocrystals via “Linkage emission”: Hopping-like propagation of infrared-excited Auger electrons

Phosphorus (P) is an n-type dopant for conductive silicon nanocrystals (Si-nc's), the electrical activation of which may be monitored through a non-radiative Auger recombination process that quenches the Si-nc luminescence. We investigated this quenching mechanism through electrical measurements of Si-nc's. Infrared-excited Auger electron emission as the non-radiative process was directly probed and the dynamics of the process are determined from a frequency response analysis. To explain the dynamics, we propose a model in which Auger electrons with a low kinetic energy establish a local inter-nanocrystal conductance and the repetition of this local conductance results in a constant photocurrent (“linkage emission”). This emission becomes significant by electron filling in the Si-nc's owing to the electrical activation of P, which is consistent with observed luminescence quenching behavior. We found that the IR photo-excited emission is distinct from the thermally induced hopping conduction and show that confined, rather than trapped, charges are the source of the Auger electrons. Thus, the process consumes both confined charges and the recombination energy for Auger emission, which explains the luminescence quenching mechanism of Si-nc:P.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: Elastic wave velocity measurement using ultrasonic system with two-reflectors

We show an experiment protocol for ultrasonic velocity measurements carried out in a synchrotron-based multi-anvil high-pressure apparatus. By adding a second reflector in the cell assembly, ultrasonic signals are significantly stabilized for experiments where samples experience structural changes such as phase transition or partial melting. Features of the elastic wave can be calculated from acoustic impedance allowing us to evaluate the possible interference between the sample reflection and other internal multiple reflections. This new protocol allows various forms of samples including cold-pressed powder samples, for which grain size and porosity can be monitored and controlled in situ during the annealing process.

47 OTHER INSTRUMENTATION↗

Optimization of switch diagnostics on the MAIZE linear transformer driver

The MAIZE Linear Transformer Driver is made of 40 capacitor-switch-capacitor `bricks' connected in parallel. When these 40 bricks are charged to 100-kV and then discharged synchronously, the MAIZE facility generates a 1-MA current pulse with a 100-ns rise time into a matched load impedance. Discharging each of the capacitors in a brick is carried out by the breakdown of a spark-gap switch, a process which results in the emission of light. Monitoring this output light with a fiber optic coupled to a photomultiplier tube (PMT) and an oscilloscope channel provides information on switch performance and timing jitter– whether a switch red early, late, or in phase with the other switches. However, monitoring each switch with a dedicated detector- oscilloscope channel can be problematic for facilities where the number of switches to be monitored (e.g., 40 on MAIZE) greatly exceeds the number of detector-oscilloscope channels available. The technique of using fibers to monitor light emission from switches can be optimized by treating a PMT as a binary digit or bit and using a combinatorial encoding scheme, where each switch is monitored by a unique combination of fiber- PMT-oscilloscope channels simultaneously. By observing the unique combination of ber-PMT-oscilloscope channels that are turned on, the pre-firing or late-firing of a single switch on MAIZE can be identified by as few as six PMT-oscilloscope channels. The number of PMT-oscilloscope channels, N , required to monitor X switches can be calculated by 2 N = X + 1, where the number '2' is selected because the PMT-oscilloscope acts as a bit. Here, we demonstrate the use of this diagnostic technique on MAIZE. In conclusion, we also present an analysis of how this technique could be scaled to monitor the tens of thousands of switches proposed for various next generation pulsed power facilities.

47 OTHER INSTRUMENTATION↗

Comparison of modular analytical wake models to the Lillgrund wind plant

Efficient and accurate wake models are required for wind plant performance modeling and the suite of engineering processes that support wind plant layout, control, and monitoring. Although many analytical and engineering wake models with low computational costs have been proposed, their ability to represent the power production of large wind plants in a wide range of atmospheric conditions is not completely understood. The following validation study reviews the underlying theory for analytical wake models, outlines quality control procedures for observational data, and compares model results with observational data from the Lillgrund Wind Plant. Lillgrund makes a valuable case study for wake modeling because of its regular arrangement and the relatively close spacing of constituent wind turbines, which lead to regular and significant wake interactions within the wind plant and the development of deep array flow conditions. Formulations for the velocity deficit, wake-added turbulence, and wake superposition methods are considered in a modular sense, yielding many possible configurations to represent wind turbine wakes, of which seven are examined in detail. Velocity deficit models that account for flow conditions in the near wake are better able to reproduce power production for wind turbines in the transitional region of the wind plant, where wind turbines experience as many as five wakes from upstream turbines. Finally, in the deep array, where power production reaches asymptotic values and wake statistics become quasi-periodic, wake superposition schemes become the largest driver in error reduction; using the linear or maximum wake superposition methods can reduce the relative root mean square error by as much as 40% in the deep array.

17 WIND ENERGY↗

Gamma radiation-induced blue shift of resonance peaks of Bragg gratings in pure silica fibres

We report the first observation of a significant gamma radiation-induced blue shift of the reflection/transmission peak of fibre Bragg gratings inscribed into pure-silica core fibres via multiphoton absorption of femtosecond pulses. At a total dose of ∼100 kGy, the shift is ∼20 pm. The observed effect is attributable to the ionising radiation-induced decrease in the density of the silica glass when the rate of colour centre formation is slow. We present results of experimental measurements that provide the key parameters of the dynamics of the gratings for remote dosimetry and temperature sensing. (laser crystals and braggg ratings)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of haemodilution on the optical properties of blood during coagulation studied by optical coherence tomography

We report an investigation of the effects of blood dilution with hypertonic (7.5 %) and normal (0.9 %) saline on its optical properties during coagulation in vitro using optical coherence tomography. The light penetration depth and attenuation coefficient are obtained from the dependences of reflectance on the depth. Normal whole blood has served as the control group. The average coagulation time is equal to 420±16,418±16 and 358±14 s with blood volume replacement of 2 %, 11 %, and 20 % by 0.9 % normal saline, respectively. With 2 %, 11% and 20% blood volume replacement with 7.5 % hypertonic saline, the average coagulation time is 422±17,1160±45 and 1730±69 s, respectively. For normal whole blood, the average coagulation time amounts to 425±19 s. it is shown that dilution with normal saline has a procoagulant effect when it replaces 20 % of blood volume, and hypertonic saline has an anticoagulant effect if it replaces 11 % or more of blood volume. It is concluded that optical coherence tomography is a potential technique to quantify and monitor the liquid – gel transition during the coagulation process of blood diluted by normal and hypertonic saline. (biophotonics)

60 APPLIED LIFE SCIENCES↗

Chemical bond reorganization in intramolecular proton transfer revealed by ultrafast X-ray photoelectron spectroscopy

Time-resolved X-ray photoelectron spectroscopy (TR-XPS) is used in a simulation study to monitor the excited state intramolecular proton transfer between oxygen and nitrogen atoms in 2-(iminomethyl)phenol. Real-time monitoring of the chemical bond breaking and forming processes is obtained through the time evolution of excited-state chemical shifts. By employing individual atomic probes of the proton donor and acceptor atoms, we predict distinct signals with opposite chemical shifts of the donor and acceptor groups during proton transfer. Details of the ultrafast bond breaking and forming dynamics are revealed by extending the classical electron spectroscopy chemical analysis to real time. Through a comparison with simulated time-resolved photoelectron spectroscopy at the valence level, the distinct advantage of TR-XPS is demonstrated thanks to its atom specificity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Raman spectroscopy of oxygen carrier particles in harsh environments

Fossil fuel combustion processes generate CO2, a greenhouse gas of considerable concern. To reduce this emission, the National Energy Technology Laboratory (NETL) is evaluating alternative combustion approaches, including chemical looping combustion (CLC). This technique generates relatively pure CO2, suitable for subsequent capture and storage. CLC uses oxygen-carrier particles (OCPs) such as iron oxides, copper oxides, calcium sulfates, etc. to provide oxygen for the combustion process. Optimization of the overall combustion process requires knowledge of the oxidation state (e.g., content of Fe2O3 vs. Fe3O4) of the OCPs during the different stages of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of OCPs in harsh environments is lacking and new sensors need to be developed. We are evaluating non-contact, stand-off Raman spectroscopy to determine the relative concentrations of the oxidized and reduced forms of OCPs at temperatures between 800 °C and 1000 °C, and pressures of about 10 atm. Using cw and pulsed Raman spectroscopy, in combination with a pressurized high-temperature sample chamber, we have optimized the operating parameters such as laser wavelength, laser intensity, collection optic design, focal spot size, etc. and measured Raman spectra of various OCP materials at high temperatures. To extract from the Raman spectra relevant information such as the concentration ratio of a material in different oxidation states, the measured data needs to be processed, and statistical modeling and multivariate calibration need to be performed.

20 FOSSIL-FUELED POWER PLANTS↗

SU-G-JeP4-10: Measurement of Prostate Motion Trajectories During Prostate SBRT Boost Treatments with a Rectafix

Purpose: To determine prostate motion during SBRT boost treatments with a Rectafix rectal sparing device in place using kV imaging during treatment. Methods: Patients each had three gold fiducial markers inserted into the prostate and received two VMAT boost fractions of 9.5–10 Gy under the PROMETHEUS clinical trial protocol with a Rectafix rectal retractor in place. Two-dimensional kilovoltage images of fiducial markers were acquired continuously during delivery. Three patients were treated on a Varian Clinac iX linear accelerator (6X, 600 MU/min), where kV images were acquired at 5 Hz during treatment. Seven patients were treated on a Varian Truebeam linear accelerator (10XFFF, 2400 MU/min) where kV images were acquired every 3 seconds. Images were processed off-line using the Kilovoltage Intrafraction Monitoring (KIM) software after treatment. KIM determines prostate position in three dimensions from 2D kV projections using a probability density model and a pre-treatment kV arc. The 3D displacement of the prostate was quantified as a function of time throughout each fraction. Results: From all fractions analyzed, it was found that the prostate had moved less than 1 mm in any direction from its initial position 84.6% of the time. The prostate was between 1 and 2 mm from its initial position 14.2% of the time, between 2 and 3 mm of its initial position 0.8% of the time and was greater than 3 mm from its initial position only 0.4% of the time. Conclusion: The amount of prostate motion observed during prostate SBRT boost treatments with a Rectafix device in place was minimal and lower than that observed in non-Rectafix studies. The Rectafix device reduces rectal dose as well as immobilizing the prostate. Kimberley Legge is the recipient of an Australian Postgraduate Award.

60 APPLIED LIFE SCIENCES↗

Devices for Diagnostics and Lithium Collection on the T-11M and T-10 Tokamaks. First Results

The use of lithium as a material of the tokamak in-vessel plasma-facing components made it necessary to develop appropriate diagnostic instruments. For the T-10 and T-11M tokamaks, devices have been developed that allow one to investigate the processes of lithium transport in the tokamak scrape-off layer, the dynamics of lithium deposition at different temperatures of the collecting surface in real time by using a piezoelectric quartz detector, adsorption and desorption of the plasma-forming gas by lithium, and the influence of the electric field on the process of lithium collection. The plasma parameters are monitored using Langmuir probes. The developed devices can be used to extract lithium deposited on the tokamak vessel wall without breaking vacuum conditions. For these purposes, a gateway and a vacuum input without bellows have been designed on the basis of an innovative liquid-metal coupling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation Source Mapping with Bayesian Inverse Methods

In this work, we present a method to map the spectral and spatial distributions of radioactive sources using a limited number of detectors. Locating and identifying radioactive materials is important for border monitoring, in accounting for special nuclear material in processing facilities, and in cleanup operations following a radioactive material spill. Most methods to analyze these types of problems make restrictive assumptions about the distribution of the source. In contrast, the source mapping method presented here allows an arbitrary three-dimensional distribution in space and a gamma peak distribution in energy. To apply the method, the problem is cast as an inverse problem where the system’s geometry and material composition are known and fixed, while the radiation source distribution is sought. A probabilistic Bayesian approach is used to solve the resulting inverse problem since the system of equations is ill-posed. The posterior is maximized with a Newton optimization method. The probabilistic approach also provides estimates of the confidence in the final source map prediction. A set of adjoint, discrete ordinates flux solutions, obtained in this work by the Denovo code, is required to efficiently compute detector responses from a candidate source distribution. These adjoint fluxes form the linear mapping from the state space to the response space. The test of the method’s success is simultaneously locating a set of 137 Cs and 60 Co gamma sources in a room. This test problem is solved using experimental measurements that we collected for this purpose. Because of the weak sources available for use in the experiment, some of the expected photopeaks were not distinguishable from the Compton continuum. However, by supplanting 14 flawed measurements (out of a total of 69) with synthetic responses computed by MCNP, the proof-of-principle source mapping was successful. The locations of the sources were predicted within 25 cm for two of the sources and 90 cm for the third, in a room with an ~4-x 4-m floor plan. Finally, the predicted source intensities were within a factor of ten of their true value.

07 ISOTOPE AND RADIATION SOURCES↗

Complexity and entropy representation for machine component diagnostics

The Complexity-entropy causality plane (CECP) is a parsimonious representation space for time series. It has only two dimensions: normalized permutation entropy and Jensen-Shannon complexity of a time series. This two-dimensional representation allows for detection of slow or rapid drifts in the condition of mechanical components monitored through sensor measurements. The CECP representation can be used for both predictive analytics and visual monitoring of changes in component condition. This method requires minimal pre-processing of raw signals. Furthermore, it is insensitive to noise, stationarity, and trends. These desirable properties make CECP a good candidate for machine condition monitoring and fault diagnostics. In this work we study the effectiveness of CECP on three rotary component condition assessment applications. We use CECP representation of vibration signals to differentiate various machine component health conditions for rotary machine components, namely roller bearing and gears. The results confirm that the CECP representation is able to detect, with high accuracy, changes in underlying dynamics of machine component degradation states. From class separability perspective, the CECP representation is able to generate linearly separable classes for the classification of different fault states. This classification performance improves with increasing signal length. For signal length of 16,384 data points, the fault classification accuracy varies from 90% to 100% for bearing applications, and from 85% to 100% for gear applications. We observed that the optimum parameter for CECP representating depends on the application. For bearing applications we found that embedding dimension D = 4, 5, 6, and embedding delay τ = 1, 2, 3 are suitable for good fault classification. For gear applications we find that embedding dimension D = 4, 5, and embedding delay τ = 1, 5 are suitable for fault classification.

47 OTHER INSTRUMENTATION↗

Lab-Scale Demonstration of Plutonium Purification by Anion Exchange, Plutonium(IV) Oxalate Precipitation, and Calcination to Plutonium Oxide to Support the MOX Feed Mission

H-Canyon and HB-Line are tasked with the production of PuO 2 from a feed of plutonium metal. The PuO 2 will provide feed material for the MOX Fuel Fabrication Facility. After dissolution of the Pu metal in H-Canyon, the solution will be transferred to HB-Line for purification by anion exchange. Subsequent unit operations include Pu(IV) oxalate precipitation, filtration and calcination to form PuO 2 . This report details the results from SRNL anion exchange, precipitation, filtration, calcination, and characterization tests, as requested by HB-Line1 and described in the task plan. This study involved an 80-g batch of Pu and employed test conditions prototypical of HB-Line conditions, wherever feasible. In addition, this study integrated lessons learned from earlier anion exchange and precipitation and calcination studies. H-Area Engineering selected direct strike Pu(IV) oxalate precipitation to produce a more dense PuO 2 product than expected from Pu(III) oxalate precipitation. One benefit of the Pu(IV) approach is that it eliminates the need for reduction by ascorbic acid. The proposed HB-Line precipitation process involves a digestion time of 5 minutes after the time (44 min) required for oxalic acid addition. These were the conditions during HB-line production of neptunium oxide (NpO 2 ). In addition, a series of small Pu(IV) oxalate precipitation tests with different digestion times were conducted to better understand the effect of digestion time on particle size, filtration efficiency and other factors. To test the recommended process conditions, researchers performed two nearly-identical larger-scale precipitation and calcination tests. The calcined batches of PuO 2 were characterized for density, specific surface area (SSA), particle size, moisture content, and impurities. Because the 3013 Standard requires that the calcination (or stabilization) process eliminate organics, characterization of PuO 2 batches monitored the presence of oxalate by thermogravimetric analysis-mass spectrometry (TGA-MS). To use the TGA-MS for carbon or oxalate content, some method development will be required. However, the TGA-MS is already used for moisture measurements. Therefore, SRNL initiated method development for the TGA-MS to allow quantification of oxalate or total carbon. That work continues at this time and is not yet ready for use in this study. However, the collected test data can be reviewed later as those analysis tools are available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗