Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Portability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Unattended Dual Current Monitor (UDCM)

Researchers at Los Alamos National Laboratory have developed the Unattended Dual Current Monitor (UDCM). The UDCM is an ideal solution for current measurement needs such as ion chamber gamma measurements. This data acquisition system simplifies hardware requirements for current applications, and provides added reliability, flexibility, and compatibility as compared with the legacy Miniature Gamma Ray and Neutron Detector (MiniGRAND) technology. It is lightweight, can be portable or mounted, is manufactured using COTS parts, and features a modern Internet-of-Things (IoT) enabled design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PETSc Users Manual (Rev. 3.13)

This manual describes the use of PETSc for the numerical solution of partial differential equations and related problems on high-performance computers. The Portable, Extensible Toolkit for Scientific Computation (PETSc) is a suite of data structures and routines that provide the building blocks for the implementation of large-scale application codes on parallel (and serial) computers. PETSc uses the MPI standard for all message-passing communication. PETSc includes an expanding suite of parallel linear solvers, nonlinear solvers, and time integrators that may be used in application codes written in Fortran, C, C++, and Python. PETSc provides many of the mechanisms needed within parallel application codes, such as parallel matrix and vector assembly routines. The library is organized hierarchically, enabling users to employ the level of abstraction that is most appropriate for a particular problem. By using techniques of object-oriented programming, PETSc provides enormous flexibility for users. PETSc is a sophisticated set of software tools; as such, for some users it initially has a much steeper learning curve than a simple subroutine library. In particular, for individuals without some computer science background, experience programming in C, C++, python, or Fortran and experience using a debugger such as gdb or dbx, it may require a significant amount of time to take full advantage of the features that enable efficient software use. However, the power of the PETSc design and the algorithms it incorporates may make the efficient implementation of many application codes simpler than \rolling them" yourself.

97 MATHEMATICS AND COMPUTING↗

High Temperature Polymer Electrolyte Membrane Fuel Cell Electrode Composition: Durable Fuel Cell Power under Anhydrous Conditions

Innovators/Researchers at Los Alamos National Laboratory have developed an electrode composition that improves fuel cell performance under anhydrous conditions above 100°C. It has demonstrated great durability in humidified conditions under 100°C as well. It holds promise for use in fuel cells for heavy duty vehicles while retaining utility for portable and stationary power applications. In coming years this flexibility may be a breakthrough improvement over conventional compositions.

25 ENERGY STORAGE↗

RELAP-7 Application and Enhancement for FLEX Strategies and ATF Behavior under Extended Loss of AC Power Conditions

This report summarizes the results of a three-year research project sponsored by the U.S. Department of Energy (DOE) Nuclear Energy University Program (NEUP) to enhance and apply the RELAP-7 code by adding and improving several important components (e.g., a mechanistic Reactor Core Isolation Cooling (RCIC) system model) for thermal hydraulic studies of LWRs under ELAP conditions and evaluating the time available for transition to portable FLEX equipment. The project team included University of Massachusetts–Lowell, The Ohio State University, Texas A&M University, Idaho National Laboratory and Oak Ridge National Laboratory. In the Fukushima accident, it was found that the RCIC system played a crucial role in delaying core meltdown by almost three days in Fukushima Daiichi Unit 2, because of self-regulated operation of the steam driven RCIC turbine-pump injection system. Steam flow in the convergent-divergent nozzles of the RCIC Terry turbine is two-phase non-equilibrium transonic flow with homogenous nucleation condensation. To more accurately predict the dynamic process and behavior of the transonic compressible steam flow, a one-dimensional transient two-phase analytical model is presented. A simplified four-fluid model was employed in the present work with the consideration of four separate fluid fields: vapor, liquid film, entrained droplets and condensed droplets. The mass, momentum and energy interactions between the fluids were considered and modeled. An extended seven-equation non-equilibrium critical flow model was developed to obtain the critical pressure and velocities of each phase at the nozzle throat. To predict the wetness in the divergent section, a mechanistic nucleation condensation model was integrated in the nozzle analysis model, considering the generation and consequent growth of droplets. The governing differential equations on a staggered grid were discretized using the second-order Lax-Wendroff scheme with a flux limiter, and the Semi-Implicit Method for Pressure-Linked Equation (SIMPLE) algorithm was employed to solve the discrete linear system. To demonstrate the predictability and reliability of the physical models and the numerical method proposed in the present work, three representative nozzles were modeled and simulated. The results show good agreement with the available experimental data, even for condensation shock. Then, the 1D nozzle model was employed to obtain nozzle flow tables of the Terry turbine nozzle for different working pressures which can cover the operation pressure range of the RCIC system. A mechanistic RCIC turbine-pump system model was developed and implemented in the system code TRACE to simulate dynamic responses of the RCIC system under Beyond Design Basis Accident (BDBA) conditions. The turbine-pump governing equations are based on the control volume approach of the angular momentum balance. The physics based mechanistic RCIC model was developed using the TRACE control system components (i.e., signal variables, control blocks, and tables), and incorporated into a TRACE boiling water reactor (BWR) model. The TRACE model in this report has a detailed nodalization of the reactor pressure vessel (RPV), and all of the major flow paths and system components, including the safety relief valves (SRVs) and the containment suppression pool and drywell. Based on the nozzle flow tables generated from the 1D nozzle model developed, the turbine drive torque can be calculated from table lookup. Since the detailed specifications of the RCIC pump are unavailable, the homologous curves for a Bingham pump were used in the current pump component. A station black-out (SBO) accident test problem was selected to demonstrate the TRACE RCIC model. The short-term SBO simulations were performed for two cladding materials: Zircaloy and FeCrAl, to demonstrate the effect of the accident tolerant fuel cladding on fuel heat-up under BDBA accident conditions. The wetwell plays a vital safety role in SBO and other BWR accident scenarios in that it can reduce containment pressure and supply additional core make-up water. The suppression pool temperature distribution has a very large impact on both RPV and containment pressure. Thus, another novel contribution of the project comes mainly from an improved, systems-level wetwell model which can capture buoyancy-induced thermal stratification effects due to steam injection and condensation. A two-zone stratified wetwell model has been implemented in RELAP-7 and some results from that model are presented. This wetwell model is capable of simulating thermal stratification due to a low steam mass injection rate. With a low mass flow rate, the model assumes that all the steam condenses within the pipe and the resulting plume can be approximated with a purely buoyant, heat-source driven model. The wetwell model developed with these assumptions is adequate to simulate slow transients such as extended SBO transients.

42 ENGINEERING↗

PAIN Schubert Review: Experiment [Slides]

These slides detail the experimental section of the PAIN Schubert Review. The PAIN project is investigating the utility of portable neutron radiography for emergency response. Further sections give an overview of the PAIN project and detail the simulation performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of Heat Pipe Failures in Microreactors

Microreactors provide new opportunities for nuclear reactor applications given their long-lived fuel source, compact size, portability, reliability as it relates to safety and their self-regulating nature. To take advantage of these opportunities there are technological challenges that need to be overcome. One advancing technology often used in conjunction with microreactor designs are heat pipes, which are used for heat removal from the reactor core to the power conversion system. Heat pipes are a substitute for the traditional system in which the same fluid used as coolant in the reactor is then used as the working fluid in the power conversion system. This document describes how heat pipes operate, what happens when a heat pipe fails, and what codes can be used to simulate the results. Our analyses show that a single/double heat pipe failure results in a temperature increase of 15-50°C respectively in surrounding heat pipes. Heat pipe microreactors could be easily designed such that this increase is within the maximum parameters allowable for safety and does not result in cascading heat pipe failure. Thus, such failures do not lead to severe degradation of the reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Calculation for T Plant Estimated PTE with Receipt of K Basin Sludge and Filter Media

The purpose of this environmental calculation is to: (1) show compliance with the WAC 173-400-110, New Source Review (NSR) for Sources and Portable Sources requirements and (2) provide the methodology, assumptions and calculation used to estimate the potential to emit (PTE) and Total Effective Dose Equivalent to the Maximally Exposed Individual (TEDE to the MEI) radionuclide airborne emissions associated with the receipt of K Basin sludge and filter media for storage at T Plant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Protect Your Family: Reduce Contamination at Home: A Summary of a Study Conducted by the National Institute for Occupational Safety and Health

Congress enacted the Health Insurance Portability and Accountability Act of 1996 (HIPAA) without including specific provisions for protecting the privacy of healthrelated information. The law gave Congress three years to enact such requirements and provided that if it failed to do so the Secretary of the Department of Health and Human Services (DHHS) was obligated to promulgate regulations to implement the statutory standards. When Congress failed to meet the deadline, the obligation to issue privacy regulations passed to DHHS. DHHS received over 52,000 comments on the proposed regulations. Responses to the comments and the final rule were published in the Federal Register on December 28, 2000. The cost of implementing the regulations over a ten-year period was estimated at $17.6 billion by DHHS. Industry estimates the cost at five times that amount.

54 ENVIRONMENTAL SCIENCES↗

Epithermal Neutron Resonance Analysis Using a Compact D-T Generator

Nuclear material identification and isotopic composition analysis are important capabilities for safeguards and the verification of nuclear arms control and nonproliferation treaties. Epithermal neutron resonance imaging has been proposed for spent fuel assay measurements, and the development of a mobile neutron imaging system could provide such a tool for on-site applications. This technique is highly sensitive to isotopes of interest for safeguards applications (e.g. 235,238 U, 238,239,240 Pu) and yields unique transmission spectra for a target containing actinides and some mid- and high-Z elements. Paired with a position-sensitive neutron detector, such a system could provide spatial information of the target isotopic composition. Recent progress in the development of high intensity neutron sources could make mobile epithermal neutron imaging designs increasingly feasible to serve as a tool for nuclear inspectors. In this work, Monte Carlo (MC) simulations were performed to further optimize a previous design for an epithermal neutron resonance-based analysis apparatus using a D-T portable neutron generator. Additionally, experimental work is being performed to test the feasibility of this method. The MC simulations of moderation time distributions for different moderator compositions and thicknesses were measured to provide a multi-group correction for neutron time-of-flight energy reconstruction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contra: A New Language for Task- and Data-Parallellism [Slides]

A new language is beneficial to take advantage of emerging architectures, and existing and new software technologies. Contra is a new language to provide performance portable code and consists of two innovations, which are described. A current status and illustrations of the code are shown.

97 MATHEMATICS AND COMPUTING↗

Integration of Kokkos into MonteRay [Slides]

Monte Carlo Neutron Transport codes are C++-based and simulate interaction of nuclear particles with materials. MonteRay is a library for accelerating Monte Carlo ray-casting tallies with GPUs. Kokkos is commonly used to write performance portable applications for HPC platforms. A goal is to implement Kokkos into the Expected Path Length file that uses Cuda as a backend. The methodology and results are summarized.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

OrganiCam: First Camera for Noncontact Biodetection in Space

Los Alamos National Laboratory designed a compact laser-induced fluorescence imaging camera with Raman spectrometer to identify organic molecules and biosignatures in environments such as Martian caves, icy-moons, and asteroid surfaces. OrganiCam is the primary instrument on the Laser-Induced Fluorescence Exploration of Caves for Organics and Volatiles using an Elevated Platform (LIFE COVE) NASA mission concept. OrganiCam could also determine if instruments being sent into space for NASA are sterile and analyze samples returned to Earth. OrganiCam’s robust design for extreme environments, portability, simple operation, and low power requirement build on LANL’s 50+ years designing robotic instruments for space applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SEDONA: SpEctroscopic Detection of Nerve Agents

Los Alamos National Laboratory developed the only portable screener to accurately detect the chemical nerve agents, providing results in seconds. Current airport detection system cannot scan for the threat of organophosphorus nerve agents and insecticides. Small quantities of these toxic chemicals can very quickly cause widespread exposure and severe symptoms. SEDONA screens through an unopened bottle using the principles of nuclear magnetic resonance spectroscopy. The system could be deployed and operated with minimal training. SEDONA dramatically reduces the likelihood of a successful nerve agent attack at airports, government buildings, embassies, sporting events, concerts, and political rallies.

47 OTHER INSTRUMENTATION↗

Development of FRET clusters for CBRN Detection

Advanced sensor capabilities for the simultaneous on-site detection of specific chemical, biological, and radiological/nuclear (CBRN) threats is important to significantly limit the risk of exposure to personnel and allow the rapid collection of essential scientific data and critical evidence. Commercially available sensor capabilities are generally complex, and/or require highly specific and ultra-sensitive methods that are often power demanding or require offsite post-analysis for positive detection, leaving personnel vulnerable. The goal of this project is to develop a portable sensor capable of simultaneously detecting CBRN signatures using a multiplexed Förster Resonance Energy Transfer (FRET) based sensor. FRET sensors are tailorable, specific, and highly dependent on the donor-acceptor distance. In this project, nanoparticles were functionalized with aptamers that were designed for the detection of methylphosphonate, a sarin metabolite. FRET was measured between quantum dot donors and dye and metal nanoparticle acceptors using optical spectroscopy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Advanced Moderation Module for High-Temperature Micro-Reactor Applications

Development and deployment of micro-reactors that provide competitive efficiency, prevailing compactness, and inherent safety is an immediate focus of the U.S. nuclear industry. For thermal neutron micro-reactors operating at elevated temperature for optimized efficiency, such as micro molten-salt reactors (MSRs), heat-pipe reactors, and very-high temperature reactors (VHTRs), high-performance moderator based on metal hydride can enhance the neutron economy and therefore achieve reduced weight and enhanced portability. As unclad metal hydride inevitably decomposes at elevated temperature, an enclosure is required for hydride moderator to deliver desired performance at elevated temperatures. Conventional moderator enclosure solutions based on high-temperature alloys introduce extraneous neutron penalty into the micro-reactor, affecting the neutronic benefits provided by the hydride moderator. Additionally, the compatibility between the high-temperature alloy enclosure and the micro-reactor matrix is also a potential issue. In this report, we disclose an Advanced Moderator Module (AMM) concept enabled by an innovative enclosure solution combining the advantages of refractory metals, ceramic matrix composites (CMCs), and advanced coating technology to serve as hydrogen permeation barrier up to very-high temperatures. A schematic description of the AMM structure is illustrated in Figure A1. The AMM contains a moderating material core made of metal hydride with high thermal stability, such as YH 2-x . The hydride core is enclosed by an H 2 barrier layer coated on a ductile refractory metal liner to minimize hydrogen loss during high-temperature operation. A ceramic matrix composite (CMC) cladding is adopted to provide further structural strength, especially during power transients. Between the CMC cladding and metal liner, an extra diffusion barrier coating is inserted to suppress the chemical interaction at elevated temperatures. Hence, based on a series of innovative material solutions, the AMM is capable of containing the metal hydride core at elevated temperature (>900oC) inside coated and lined CMC envelop with negligible hydrogen loss throughout the microreactor lifetime. The benefit of the AMM technology was assessed based on a comprehensive multi-stage reactor-physics analysis. Advanced moderation based on hydride metals (such as YH2-x) enables reaching optimum moderation with higher fuel content than traditional VHTR technology, which is required to design compact micro-reactor cores targeting long-life operation. The AMM enclosure technology provides lower thermal neutron absorption rates than traditional solutions (based on stainless steel or Mo-based alloy such as TZM), which reduces the fissile enrichment requirements by 6-8% on a TRISO-fueled design based on the EMPIRE core. Finally, combining the hydride moderator with neutron transparent enclosure solutions provides significant potential to boost neutronics performance of micro-reactors in terms of increased core lifetime or reduced size and weight by 30-50% on a micro-reactor based on the Holos Quad technology. The progress and plans for on-going development and demonstration efforts are also discussed in this report. The current demonstration of AMM is focused on the hydrogen diffusion barrier demonstration under thermal cycling, while radiation tolerance demonstration is planned. The next step of the demonstration plan will be the assembly of miniature AMM for high-temperature testing, which can be used as a prototype for future pilot scale demonstration.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

PNNL Measurement Results for the 2018 FlatTop Criticality Nuclear Accident Dosimetry Exercise at the Nevada National Security Site (IER-253)

The Pacific Northwest National Laboratory (PNNL) participated in the FlatTop exercise IER-253 at the National Nuclear Security Site (NNSS) during the week of May 21, 2018. This report summarizes the measurements of the personal nuclear accident dosimeters (PNAD). Additionally, portable survey instrument readings and measurements of the simulated biological samples are included. The FlatTop exercise (IER-253) tested only PNADs and did not include fixed nuclear accident dosimeters (FNAD). Previous PNAD results obtained in 2016 at the Godiva-IV exercise IER-148 were summarized in PNNL Measurement Results for the 2016 Criticality Accident Dosimetry Exercise at the Nevada National Security Site IER-148 (PNNL-26497). The results clearly indicated that the previous dose conversions were a historical legacy of the Hanford Site and corresponded closer to kerma dose (or first collision dose, and not to Hp(10) dose). The technical basis for PNAD dose was based on the Godiva-IV exercise and documented in A New Dose Calculation Methodology for New PNAD and FNAD Designs at PNNL (PNNL-27023). The configuration of the PNAD was described in these two documents. The FlatTop exercise was the first time PNNL tested this new dose calculation methodology. Results were generally favorable with some results conservatively over reported that fell above the performance criteria. The reported gamma dose results fell non-conservatively low because only the default parameters obtained from the Godiva-IV exercise were used, and because the OSL gamma dosimeter has an energy dependency. The results from the simulated biological samples were also favorable, and in several cases conservatively over reported.

61 RADIATION PROTECTION AND DOSIMETRY↗

Magnetic Detection of Chemical Threats

Los Alamos researchers have developed a technology to quickly detect chemical threats using a fieldable detector that provides real-time detection to ensure safety for warfighters, agricultural workers, and the general public. Traditional laboratory-based detection does not allow for agile response to threats on the battlefield or to our food supply chain. Our portable detector brings the laboratory to the field for real-time detection of chemical agents in samples without needing to send the samples to a remote location for analysis. This technology fits a market need in public safety, military sensor design, and pesticide detection. We have proven that this technology works on the benchtop, and are working to miniaturize the system to enable deployment. We are seeking qualified licensing or CRADA partners to finalize development of this system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling a ring magnet in ALEGRA

We show here that Sandia's ALEGRA software can be used to model a permanent magnet in 2D and 3D, with accuracy matching that of the open-source commercial software FEMM. This is done by conducting simulations and experimental measurements for a commercial-grade N42 neodymium alloy ring magnet with a measured magnetic field strength of approximately 0.4 T in its immediate vicinity. Transient simulations using ALEGRA and static simulations using FEMM are conducted. Comparisons are made between simulations and measurements, and amongst the simulations, for sample locations in the steady-state magnetic field. The comparisons show that all models capture the data to within 7%. The FEMM and ALEGRA results agree to within approximately 2%. The most accurate solutions in ALEGRA are obtained using quadrilateral or hexahedral elements. In the case where iron shielding disks are included in the magnetized space, ALEGRA simulations are considerably more expensive because of the increased magnetic diffusion time, but FEMM and ALEGRA results are still in agreement. The magnetic field data are portable to other software interfaces using the Exodus file format.

36 MATERIALS SCIENCE↗