Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROXIMITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

New tool for kinematic regime estimation in semi-inclusive deep-inelastic scattering

We introduce a new phenomenological tool based on momentum region indicators to guide the analysis and interpretation of semi-inclusive deep-inelastic scattering measurements. The new tool, referred to as “affinity”, is devised to help visualize and quantify the proximity of any experimental kinematic bin to a particular hadron production region, such as that associated with transverse momentum dependent factorization. We apply the affinity estimator to existing HERMES and COMPASS data and expected data from Jefferson Lab and the future Electron-Ion Collider. We also provide an interactive notebook based on Machine Learning for fast evaluation of affinity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark Matter searches with photons at the LHC

We unveil blind spot regions in dark matter (DM) direct detection (DMDD), for weakly interacting massive particles with a mass around a few hundred GeV that may reveal interesting photon signals at the LHC. We explore a scenario where the DM primarily originates from the singlet sector within the Z 3 -symmetric Next-to-Minimal Supersymmetric Standard Model (NMSSM). A novel DMDD spin-independent blind spot condition is revealed for singlino-dominated DM, in cases where the mass parameters of the higgsino and the singlino-dominated lightest supersymmetric particle (LSP) exhibit opposite relative signs (i.e., κ < 0), emphasizing the role of nearby bino and higgsino-like states in tempering the singlino-dominated LSP. Additionally, proximate bino and/or higgsino states can act as co-annihilation partner(s) for singlino-dominated DM, ensuring agreement with the observed relic abundance of DM. Remarkably, in scenarios involving singlino-higgsino co-annihilation, higgsino-like neutralinos can distinctly favor radiative decay modes into the singlino-dominated LSP and a photon, as opposed to decays into leptons/hadrons. In exploring this region of parameter space within the singlino-higgsino compressed scenario, we study the signal associated with at least one relatively soft photon alongside a lepton, accompanied by substantial missing transverse energy (E T ) and a hard initial state radiation jet at the LHC. In the context of singlino-bino co-annihilation, the bino state, as the next-to-LSP, exhibits significant radiative decay into a soft photon and the LSP, enabling the possible exploration at the LHC through the triggering of this soft photon alongside large E T and relatively hard leptons/jets resulting from the decay of heavier higgsino-like states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A search for microscopic black holes, string balls, and sphalerons in proton-proton collisions at $\sqrt{s}=13$ TeV

A search for microscopic black holes, string balls, and electroweak sphalerons using proton-proton collisions at $\sqrt{s}=13$ TeV recorded with the CMS detector at the CERN LHC during the 2016–2018 data taking, and corresponding to an integrated luminosity of 138 fb −1 , is presented. Two search strategies based on control samples in data are used. Model-independent limits on the cross section of physics phenomena with multiple energetic jets, leptons, and photons are set using a method that relies on the shape invariance of the scalar sum of the transverse momenta of all objects in the event. Model-dependent limits on black hole and sphaleron production are set using a newly introduced method that has been developed for the identification of collider events with distinct kinematic features by separating them into classes based on phase space proximity. In the context of models with large extra dimensions, semiclassical black holes and string balls with masses below 8.4–11.4 TeV and 9.0–10.7 TeV, respectively, are excluded at 95% confidence level, significantly extending the reach beyond previous searches. Results of a dedicated search for electroweak sphalerons are used to derive an upper limit of 0.0034 at 95% confidence level on the fraction of quark-quark interactions, with a center-of-mass energy above the nominal sphaleron transition energy threshold of 9 TeV, that result in a sphaleron transition.

Beyond Standard Model↗

Linear sigma dark matter

We present a model of self-interacting dark matter based on QCD-like theories and inspired by the proximity of a 0 (980 ± 20) to the $K\bar{K}$ (990) threshold. Dark matter is comprised of dark pions which self-scatter via the σ resonance close to the ππ threshold. While the linear sigma model serves as a qualitative guide, a fully unitary description of the scattering in the strongly coupled regime is given by effective range theory. The introduction of a kinetically mixed dark photon allows the dark pion to either freeze-out or -in. We study the viable parameter space which explains the observed relic abundance while evading all current constraints. Searches for dark matter self interactions at different scales, (in)direct detection signals, and (in)visibly-decaying dark photons will test this model in the near future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In silico investigation of blast-induced intracranial fluid cavitation as it potentially leads to traumatic brain injury

In this paper, we conducted computational macroscale simulations predicting blast-induced intracranial fluid cavitation possibly leading to brain injury. To further understanding of this problem, we developed microscale models investigating the effects of blast-induced cavitation bubble collapse within white matter axonal fiber bundles of the brain. We model fiber tracks of myelinated axons whose diameters are statistically representative of white matter. Nodes of Ranvier are modeled as unmyelinated sections of axon. Extracellular matrix envelops the axon fiber bundle, and gray matter is placed adjacent to the bundle. Cavitation bubbles are initially placed assuming an intracranial wave has already produced them. Pressure pulses, of varied strengths, are applied to the upper boundary of the gray matter and propagate through the model, inducing bubble collapse. Simulations, conducted using the shock wave physics code CTH, predict an increase in pressure and von Mises stress in axons downstream of the bubbles after collapse. This appears to be the result of hydrodynamic jetting produced during bubble collapse. Interestingly, results predict axon cores suffer significantly lower shear stresses from proximal bubble collapse than does their myelin sheathing. Finally, simulations also predict damage to myelin sheathing, which, if true, degrades axonal electrical transmissibility and general health of the white matter structures in the brain.

60 APPLIED LIFE SCIENCES↗

Optimal Control of Evolution Mixed Variational Inclusions

Optimal control problems of primal and dual evolution mixed variational inclusions, in reflexive Banach spaces, are studied. The solvability analysis of the mixed state systems is established via duality principles. The optimality analysis is performed in terms of perturbation conjugate duality methods, and proximation penalty-duality algorithms to mixed optimality conditions are further presented. Applications to nonlinear diffusion constrained problems as well as quasistatic elastoviscoplastic bilateral contact problems exemplify the theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rerouting reductant flux via protein tethering enhances biohydrogen production in Thermococcus kodakarensis

Microbes that generate copious amounts of hydrogen (H 2 ) via dark fermentation are a promising means to evolve and improve renewable biofuels. Many anaerobic hyperthermophilic archaea, such as the fast-growing, genetically tractable, heterotroph Thermococcus kodakarensis, produce generous quantities of H2 and provide an idealized platform to further optimize naturally high levels of biohydrogen reduction. Precise genetic manipulations and modifications to growth conditions have already resulted in substantial increases to H2 output but additional improvements are desired. An unexamined and potentially valuable route towards increased H 2 production is to tether select electron donor and acceptor proteins together to reroute and maximize the flow of electrons towards H 2 production. Such strategies have shown promise in Bacteria and Eukarya but have not yet been investigated in thermophilic Archaea. Here, we generate and evaluate twelve novel T. kodakarensis strains wherein a proteinaceous electron carrier (a ferredoxin, Fd) is physically tethered to the membrane-bound-hydrogenase (MBH), the sole H 2 producing enzyme, to direct electron flux towards biohydrogen generation. Growth assessments and H 2 output measurements demonstrate that strains encoding protein-fusions evolve up to ~ 40% more H2 per cell than the host strain. Eliminating H 2 consumption and alternative routes of electron sinks in concert with protein tethering further increased H2 output per cell for a maximum increase of ~ 66% over the host strain. Our results demonstrate that rerouting electron flux via protein tethering coupled with the elimination of reductant sinks is a promising means towards improved biohydrogen production in T. kodakarensis. KEY POINTS: Protein tethering between redox proteins can reroute electron flux in vivo. Enforced protein proximity results in ~ 40% increases in H2 production per cell. Protein-tethering provides a generalizable framework to redirect redox metabolism.

59 BASIC BIOLOGICAL SCIENCES↗

Application of side-hole catheter technique for transradial arterial chemoembolization in patients with hepatocellular carcinoma

Purpose: The purpose of this study was to retrospectively evaluate the efficacy and safety of side-hole catheter technique for transarterial chemoembolization (TACE) via transradial artery access (TRA) in patients with hepatocellular carcinoma. Materials and methods: From November 2015 to August 2017, a total of 1040 TACE procedures were performed via TRA for hepatocellular carcinoma. In 10 (1%) of these 1040 TACE procedures via TRA, conventional microcatheter technique (CMT) failed and side-hole catheter technique was attempted. Results: Ten procedures of selective catheterizations by CMT failed due to the poor stability of the angiographic catheters or the target artery arising from the very proximal portion of the parent artery. These arteries included the right inferior phrenic artery in eight patients, one left gastric artery, and one right renal capsular artery. Cobra or MPA catheter with the microcatheter through the side-hole yielded a technical success rate of 100%. No procedure-related complications were observed. The mean time required to catheterize the target artery with the side-hole catheter was 9.5 min (5–15 min). Conclusion: Side-hole catheter technique may enable the completion of chemoembolization in cases that a potential tumor-feeding vessel cannot be catheterized by means of CMT for TACE via TRA.

60 APPLIED LIFE SCIENCES↗

Advancing Environmental Flow Science: Developing Frameworks for Altered Landscapes and Integrating Efforts Across Disciplines

Environmental flows represent a legal mechanism to balance existing and future water uses and sustain non-use values. Here, we identify current challenges, provide examples where they are important, and suggest research advances that would benefit environmental flow science. Specifically, environmental flow science would benefit by (1) developing approaches to address streamflow needs in highly modified landscapes where historic flows do not provide reasonable comparisons, (2) integrating water quality needs where interactions are apparent with quantity but not necessarily the proximate factor of the ecological degradation, especially as frequency and magnitudes of inflows to bays and estuaries, (3) providing a better understanding of the ecological needs of native species to offset the often unintended consequences of benefiting non-native species or their impact on flows, (4) improving our understanding of the non-use economic value to balance consumptive economic values, and (5) increasing our understanding of the stakeholder socioeconomic spatial distribution of attitudes and perceptions across the landscape. Environmental flow science is still an emerging interdisciplinary field and by integrating socioeconomic disciplines and developing new frameworks to accommodate our altered landscapes, we should help advance environmental flow science and likely increase successful implementation of flow standards.

54 ENVIRONMENTAL SCIENCES↗

Bifurcated Endograft (Excluder) in the Treatment of Isolated Iliac Artery Aneurysm: Preliminary Report

The aim of this study was to evaluate the effectiveness of endovascular repair in the treatment of isolated iliac artery aneurysm (IAA) using Excluder bifurcated endograft. Eight consecutive patients with IAA were treated during a period of 45 months using Excluder bifurcated endograft. Two patients presented with isolated IAA rupture and were treated emergently, whereas the other six patients underwent elective treatment. All aneurysms lacked sufficient proximal necks and therefore were not suitable for tubular-shaped endograft. Follow-up imaging was performed at 1 week, at every 3 months during the first year, semiannually until 2 years, and annually afterward using angio-computed axial tomography and plain films. Technical success was achieved in all patients. No mortality was seen despite two patients having IAA rupture. Follow-up (12 to 60 months) was done in all but one patient. During this period, complications were observed in three patients. One patient developed sexual impotence at 3-month follow up; one patient presented unilateral gluteal claudication after the procedure, which resolved at 3 months; and one patient developed a graft porosity-related endoleak, which was successfully managed with placement of an additional ipsilateral iliac extension. Endovascular treatment of isolated IAA using bifurcated endograft is safe and can be an alternative to surgical treatment. The benefits from decreased morbidity and mortality of endoluminal treatment of isolated IAA using bifurcated endograft outweigh the minor complications associated with this technique, which are mostly related to occlusion of hypogastric arteries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hepatocellular Carcinoma Supplied by the Right Lumbar Artery

This study evaluated the clinical features of hepatocellular carcinoma (HCC) supplied by the right lumbar artery. Eleven patients with HCC supplied by the right lumbar artery were treated with chemoembolization. The patients' medical records were retrospectively analyzed. All patients underwent 6.7 {+-} 3.7 (mean {+-} SD) chemoembolization sessions, and the hepatic arterial branches were noted as being attenuated. The right inferior phrenic artery (IPA) was also embolized in 10 patients. The interval between initial chemoembolization and chemoembolization of the lumbar artery supply was 53.2 {+-} 26.9 months. Mean tumor diameter was 3.1 {+-} 2.4 cm and was located at the surface of S7 and S6. The feeding-branch arose proximal to the bifurcation of the dorsal ramus and muscular branches (n = 8) or from the muscular branches (n = 3) of the right first (n = 10) or second lumbar artery (n = 1). The anterior spinal artery originated from the tumor-feeding lumbar artery in one patient. All feeders were selected, and embolization was performed after injection of iodized oil and anticancer drugs (n = 10) or gelatin sponge alone in a patient with anterior spinal artery branching (n = 1). Eight patients died from tumor progression 10.1 {+-} 4.6 months later, and two patients survived 2 and 26 months, respectively. The remaining patient died of bone metastases after 32 months despite liver transplantation 10 months after chemoembolization. The right lumbar artery supplies HCC located in the bare area of the liver, especially in patients who undergo repeated chemoembolization, including chemoembolization by way of the right IPA. Chemoembolization by way of the right lumbar artery may be safe when the feeder is well selected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiocephalic Fistula Complicated by Distal Ischemia: Treatment by Ulnar Artery Dilatation

Hand ischemic steal syndrome due to a forearm arteriovenous fistula is a rare occurrence. However, its frequency is increasing with the rise in numbers of elderly and diabetic patients. This complication, which is more common for proximal than for distal accesses, can be very severe and may cause loss of hand function, damage to fingers, and even amputation of fingers or the hand. Its treatment is difficult and often leads to access loss. We report here a case of severe hand ischemia related to a radiocephalic fistula successfully treated by ulnar artery dilatation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Case of Late Femoral Pseudoaneurysm Caused by Stent Disconnection

We present the case of a late superficial femoral artery stent disconnection causing an asymptomatic pseudoaneurysm successfully treated with a stent-graft. A 67-year-old female was referred to our department for evaluation of claudication of the left lower limb and was diagnosed to have a total occlusion of the superficial femoral artery. Three nitinol stents were used to revascularize this artery. At 48 months, duplex-ultrasonography control revealed the presence of a 45-mm saccular femoral dilatation; X-rays and CT angiography showed fractures of the proximal stents and the presence of a pseudoaneurysm at the site of the distal stents disconnection. The pseudoaneurysm was excluded using two stent-grafts. We conclude that patients and surgeons should be aware of structural complications with all stents. Rigorous follow-up controls should be mandatory. Endovascular repair proved to be feasible and durable to manage a previous endovascular procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Central Vein Dilatation Prior to Concomitant Port Implantation

Implantation of subcutaneous port systems is routinely performed in patients requiring repeated long-term infusion therapy. Ultrasound- and fluoroscopy-guided implantation under local anesthesia is broadly established in interventional radiology and has decreased the rate of complications compared to the surgical approach. In addition, interventional radiology offers the unique possibility of simultaneous management of venous occlusion. We present a technique for recanalization of central venous occlusion and angioplasty combined with port placement in a single intervention which we performed in two patients. Surgical port placement was impossible owing to occlusion of the superior vena cava following placement of a cardiac pacemaker and occlusion of multiple central veins due to paraneoplastic coagulopathy, respectively. In both cases the affected vessel segments were dilated with balloon catheters and the port systems were placed thereafter. After successful dilatation, the venous access was secured with a 25-cm-long, 8-Fr introducer sheath, a subcutaneous pocket prepared, and the port catheter tunneled to the venipuncture site. The port catheter was introduced through the sheath with the proximal end connected to a 5-Fr catheter. This catheter was pulled through the tunnel in order to preserve the tunnel and, at the same time, allow safe removal of the long sheath over the wire. The port system functioned well in both cases. The combination of recanalization and port placement in a single intervention is a straightforward alternative for patients with central venous occlusion that can only be offered by interventional radiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adrenal Venous Sampling: Where Is the Aldosterone Disappearing to?

Adrenal venous sampling (AVS) is generally considered to be the gold standard in distinguishing unilateral and bilateral aldosterone hypersecretion in primary hyperaldosteronism. However, during AVS, we noticed a considerable variability in aldosterone concentrations among samples thought to have come from the right adrenal glands. Some aldosterone concentrations in these samples were even lower than in samples from the inferior vena cava. We hypothesized that the samples with low aldosterone levels were unintentionally taken not from the right adrenal gland, but from hepatic veins. Therefore, we sought to analyze the impact of unintentional cannulation of hepatic veins on AVS. Thirty consecutive patients referred for AVS were enrolled. Hepatic vein sampling was implemented in our standardized AVS protocol. The data were collected and analyzed prospectively. AVS was successful in 27 patients (90%), and hepatic vein cannulation was successful in all procedures performed. Cortisol concentrations were not significantly different between the hepatic vein and inferior vena cava samples, but aldosterone concentrations from hepatic venous blood (median, 17 pmol/l; range, 40-860 pmol/l) were markedly lower than in samples from the inferior vena cava (median, 860 pmol/l; range, 460-4510 pmol/l). The observed difference was statistically significant (P < 0.001). Aldosterone concentrations in the hepatic veins are significantly lower than in venous blood taken from the inferior vena cava. This finding is important for AVS because hepatic veins can easily be mistaken for adrenal veins as a result of their close anatomic proximity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Looking for the Ideal Particle: An Experimental Embolization Study

This study sought to compare the most frequently used embolic particles in an animal model. In 16 New Zealand white rabbits, right renal arteries were embolized using four different embolic particles (polyvinyl alcohol [PVA] particles, 150-250 {mu}m; PVA microspheres [PVAMs], 150-300 {mu}m; Tris-acryl gelatin microspheres [TGMs], 100-300 {mu}m; expanding microspheres [EXMs], 50-100 {mu}m). Quantity of embolic material used, embolization time, and angiographic patterns were documented. Fourteen days later, a control angiography was done to document angiographic recanalization and all animals were sacrificed. Histopathological specimens were analyzed for microscopic appearance and granulometric size of the particles, extravasation of the particles, perivascular inflammation, and neocapillarization. The volume of the infarct area in each kidney was calculated. Results revealed a significantly lesser amount of embolic material used in the EXM group (p = 0.020). The angiographic recanalization rate in the EXM group (100%), compared with the PVA (0%) and TGM (0%) groups, was found to be statistically significant (p = 0.014). Although 75% of the renal arteries embolized with PVAMs were recanalized, this was not found to be statistically significant (p = 0.071). Occlusion levels in the PVA group were more proximal than with any of the microspheres. While there was no extravasation in the TGM group, extravasation rates in the PVA, PVAM, and EXM groups were 50%, 25%, and 75%, respectively. A mild degree of inflammation was noted in the PVA, PVAM, and TGM groups. EXMs caused a moderate degree of inflammation in two kidneys (50%). There was neocapillarization in the vessel lumen in all kidneys in the PVA and PVAM groups. The difference was significant (p = 0.014) compared with the TGM and EXM groups, which did not have any neocapillarization. Regarding infarct area volumes, the difference among the groups was significant (p = 0.022). EXMs caused significantly (p = 0.021) less infarction than the other embolic agents. We conclude that EXMs are less efficient due to a high recanalization rate and lesser volume of infarct compared with the other embolic agents in the rabbit kidney model. The most efficient embolization was seen in kidneys embolized with TGMs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Successful Antibiotic Treatment of Severe Staphylococcal Infection of a Long Stent Graft in the Superficial Femoral Artery with Graft Preservation in the Long Term

Introduction: Bacterial infection of endovascular stent grafts is a serious condition, regularly leading to graft replacement by open bypass surgery.Case ReportWe describe the case of a staphylococcal infection of a 150-mm covered stent graft (Gore Viabahn), placed in the superficial femoral artery. Stent graft infection was successfully treated by oral administration of penicillinase-resistant flucloxacillin and the lipopeptide daptomycin with complete graft preservation, not requiring surgical treatment. During 1-year follow-up, the graft infection did not reappear. However, the patient developed restenosis at the proximal margin of the stent with recurrence of mild claudication, so far treated conservatively. Conclusion: With the increased use of covered stent grafts in the peripheral vasculature, the frequency of graft infection will increase. We demonstrate that with newly developed antibiotics, it is possible to treat this severe complication conservatively, with complete graft preservation and without the need for bypass surgery in selected cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Frequency-Domain Intravascular Optical Coherence Tomography of the Femoropopliteal Artery

Purpose: Optical coherence tomography (OCT) is a catheter-based imaging method that employs near-infrared light to produce high-resolution intravascular images. The authors report the safety and feasibility and illustrate common imaging findings of frequency-domain OCT (FD-OCT) imaging of the femoropopliteal artery in a series of 20 patients who underwent infrainguinal angioplasty. Methods: After crossing the lesion of interest, OCT was performed with a dextrose saline flush technique with simultaneous obstructive manual groin compression. An automatic pullback FD-OCT device was employed (each scan acquiring 54 mm of vessel lumen in 271 consecutive frames). OCT images were acquired before and after balloon dilatation and following provisional stenting if necessary and were evaluated for baseline characteristics of plaque or in-stent restenosis (ISR), vessel wall trauma after angioplasty, presence of thrombus, stent apposition, and tissue prolapse. Imaging follow-up was not included in this study's protocol. Results: Twenty-seven obstructive lesions (18 cases of de novo atherosclerosis and 9 of ISR) of the femoropopliteal artery were imaged and 148 acquisitions were analyzed in total. High-resolution intravascular OCT imaging with effective blood clearance was achieved in 93.9%. Failure was mainly attributed to preocclusive proximal lesions and/or collateral flow. Mixed features of lipid pool areas, calcium deposits, necrotic core, and fibrosis were identified in all of the imaged atherosclerotic lesions, whereas ISR was purely fibrotic. After balloon angioplasty, OCT identified extensive intimal tears in all cases and one case of severe dissection that biplane subtraction angiography failed to identify. Conclusions: Infrainguinal frequency-domain optical coherence tomography is safe and feasible and may provide intravascular high-resolution imaging of the femoropopliteal artery during infrainguinal angioplasty procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗