Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLUGGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

A comprehensive experimental and kinetic modeling study of di-isobutylene isomers: Part 2

A wide variety of high temperature experimental data obtained in this study complement the data on the oxidation of the two di-isobutylene isomers presented in Part I and offers a basis for an extensive validation of the kinetic model developed in this study. Due to the increasing importance of unimolecular decomposition reactions in high-temperature combustion, we have investigated the di-isobutylene isomers in high dilution utilizing a pyrolysis microflow reactor and detected radical intermediates and stable products using vacuum ultraviolet (VUV) synchrotron radiation and photoelectron photoion coincidence (PEPICO) spectroscopy. Additional speciation data at oxidative conditions were also recorded utilizing a plug flow reactor at atmospheric pressure in the temperature range 725-1150 K at equivalence ratios of 1.0 and 3.0 and at residence times of 0.35 s and 0.22 s, respectively. Combustion products were analyzed using gas chromatography (GC) and mass spectrometry (MS). Ignition delay time measurements for di-isobutylene were performed at pressures of 15 and 30 bar at equivalence ratios of 0.5, 1.0, and 2.0 diluted in 'air' in the temperature range 900-1400 K using a high-pressure shock-tube facility. New measurements of the laminar burning velocities of di-isobutylene/air flames are also presented. The experiments were performed using the heat flux method at atmospheric pressure and initial temperatures of 298-358 K. Moreover, data consistency was assessed with the help of analysis of the temperature and pressure dependencies of laminar burning velocity measurements, which was interpreted using an empirical power-law expression. Electronic structure calculations were performed to compute the energy barriers to the formation of many of the product species formed. The predictions of the present mechanism were found to be in adequate agreement with the wide variety of experimental measurements performed.

09 BIOMASS FUELS↗

Drilling and abandonment preparation of CO₂ storage wells – Experience from the Ketzin pilot site

At Ketzin, located west of Berlin, the GFZ German Centre for Geosciences is operating Europe's largest CO₂ research storage site. This pilot site has been developed since 2004 and is comprised of one combined injection/observation well and four monitoring wells. From June 2008 to August 2013, a total of 67 kilotons of CO₂ were safely injected into the sandstone units of the Upper Triassic Stuttgart Formation in a depth between 630 to 650 m. The paper discusses the well designs and lessons learned in drilling engineering and operations. The abandonment phase started in Ketzin with the first plug cementation of the observation well Ktzi 202 shortly after shut-in of CO₂ injection. The experience with the first CO₂ well killing operation will be reviewed.

54 ENVIRONMENTAL SCIENCES↗

Enhancing the rate capability of high capacity xLi{sub 2}MnO{sub 3} {sm_bullet} (1-x)LiMO{sub 2} (M=Mn, Ni, Co) electrodes.

The rate capability of high capacity xLi{sub 2}MnO{sub 3} {center_dot} (1 - x)LiMO{sub 2} (M = Mn, Ni, Co) electrodes for lithium-ion batteries has been significantly enhanced by stabilizing the electrode surface by reaction with a Li-Ni-PO{sub 4} solution, followed by a heat-treatment step. Reversible capacities of 250 mAh/g at a C/11 rate, 225 mAh/g at C/2 and 200 mAh/g at C/1 have been obtained from 0.5Li{sub 2}MnO{sub 3} {center_dot} 0.5LiNi{sub 0.44}Co{sub 0.25}Mn{sub 0.31}O{sub 2} electrodes between 4.6 and 2.0 V. The data bode well for their implementation in batteries that meet the 40-mile range requirement for plug-in hybrid vehicles.

25 ENERGY STORAGE↗

Sulfone-based electrolytes for high voltage li-ion batteries.

Sulfone-based electrolytes have been investigated as electrolytes for lithium-ion cells using high-voltage positive electrodes, such as LiMn{sub 2}O{sub 4} and LiNi{sub 0.5}Mn{sub 1.5}O{sub 4} spinels, and Li{sub 4}Ti{sub 5}O{sub 12} spinel as negative electrode. In the presence of imide salt (LiTFSI) and ethyl methyl sulfone or tetramethyl sulfone (TMS) electrolytes, the Li{sub 4}Ti{sub 5}O{sub 12}/LiMn{sub 2}O{sub 4} cell exhibited a specific capacity of 80 mAh g{sup -1} with an excellent capacity retention after 100 cycles. In a cell with high-voltage LiNi{sub 0.5}Mn{sub 1.5}O{sub 4} positive electrode and 1 M LiPF{sub 6} in TMS as electrolyte, the capacity reached 110 mAh g{sup -1} at the C/12 rate. When TMS was blended with ethyl methyl carbonate, the Li{sub 4}Ti{sub 5}O{sub 12}/LiNi{sub 0.5}Mn{sub 1.5}O{sub 4} cell delivered an initial capacity of 80 mAh g{sup -1} and cycled fairly well for 1000 cycles under 2C rate. The exceptional electrochemical stability of the sulfone electrolytes and their compatibility with the Li{sub 4}Ti{sub 5}O{sub 12} safer and stable anode were the main reason behind the outstanding electrochemical performance observed with high-potential spinel cathode materials. These electrolytes could be promising alternative electrolytes for high-energy density battery applications such as plug-in hybrid and electric vehicles that require a long cycle life.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Occupancy schedules learning process through a data mining framework

Building occupancy is a paramount factor in building energy simulations. Specifically, lighting, plug loads, HVAC equipment utilization, fresh air requirements and internal heat gain or loss greatly depends on the level of occupancy within a building. Developing the appropriate methodologies to describe and reproduce the intricate network responsible for human-building interactions are needed. Extrapolation of patterns from big data streams is a powerful analysis technique which will allow for a better understanding of energy usage in buildings. A three-step data mining framework is applied to discover occupancy patterns in office spaces. First, a data set of 16 offices with 10 minute interval occupancy data, over a two year period is mined through a decision tree model which predicts the occupancy presence. Then a rule induction algorithm is used to learn a pruned set of rules on the results from the decision tree model. Finally, a cluster analysis is employed in order to obtain consistent patterns of occupancy schedules. Furthermore, the identified occupancy rules and schedules are representative as four archetypal working profiles that can be used as input to current building energy modeling programs, such as EnergyPlus or IDA-ICE, to investigate impact of occupant presence on design, operation and energy use in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spatial distribution of internal heat gains: A probabilistic representation and evaluation of its influence on cooling equipment sizing in large office buildings

Internal heat gains from occupants, lighting, and plug loads are significant components of the space cooling load in an office building. Internal heat gains vary with time and space. The spatial diversity is significant, even for spaces with the same function in the same building. The stochastic nature of internal heat gains makes determining the peak cooling load to size air-conditioning systems a challenge. The traditional conservative practice of considering the largest internal heat gain among spaces and applying safety factors overestimates the space cooling load, which leads to oversized air-conditioning equipment and chiller plants. In this study, a field investigation of several large office buildings in China led to the development of a new probabilistic approach that represents the spatial diversity of the design internal heat gain of each tenant as a probability distribution function. In a large office building, a central chiller plant serves all air handling units (AHUs), with each AHU serving one or more floors of the building. Therefore, the spatial diversity should be considered differently when the peak cooling loads to size the AHUs and chillers are calculated. Finally, the proposed approach considers two different levels of internal heat gains to calculate the peak cooling loads and size the AHUs and chillers in order to avoid oversizing, improve the overall operating efficiency, and thus reduce energy use.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A framework for quantifying the impact of occupant behavior on energy savings of energy conservation measures

To improve energy efficiency—during new buildings design or during a building retrofit—evaluating the energy savings potential of energy conservation measures (ECMs) is a critical task. In building retrofits, occupant behavior significantly impacts building energy use and is a leading factor in uncertainty when determining the effectiveness of retrofit ECMs. Current simulation-based assessment methods simplify the representation of occupant behavior by using a standard or representative set of static and homogeneous assumptions ignoring the dynamics, stochastics, and diversity of occupant's energy-related behavior in buildings. The simplification contributes to significant gaps between the simulated and measured actual energy performance of buildings. This paper presents a framework for quantifying the impact of occupant behaviors on ECM energy savings using building performance simulation. During the first step of the study, three occupant behavior styles (austerity, normal, and wasteful) were defined to represent different levels of energy consciousness of occupants regarding their interactions with building energy systems (HVAC, windows, lights and plug-in equipment). Next, a simulation workflow was introduced to determine a range of the ECM energy savings. Then, guidance was provided to interpret the range of ECM savings to support ECM decision making. Finally, a pilot study was performed in a real building to demonstrate the application of the framework. Simulation results show that the impact of occupant behaviors on ECM savings vary with the type of ECM. Occupant behavior minimally affects energy savings for ECMs that are technology-driven (the relative savings differ by less than 2%) and have little interaction with the occupants; for ECMs with strong occupant interaction, such as the use of zonal control variable refrigerant flow system and natural ventilation, energy savings are significantly affected by occupant behavior (the relative savings differ by up to 20%). Finally, the study framework provides a novel, holistic approach to assessing the uncertainty of ECM energy savings related to occupant behavior, enabling stakeholders to understand and assess the risk of adopting energy efficiency technologies for new and existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A novel occupancy detection solution using low-power IR-FPA based wireless occupancy sensor

Significant energy savings can be achieved by operating heating, ventilation, and air conditioning control systems with indoor occupancy measurement information. This paper presents a novel plug-and-play occupancy sensing method which will enable temporal minimization of building energy consumption to meet building usage behavior without privacy concerns. The proposed wireless occupancy sensing platform is based on long-wave infra-red (LWIR) focal-plane arrays (FPAs), or thermal imagers, that detect thermal energy rather than visible light. We developed an advanced sensor package consisting of multiple thermal imagers with low-cost optical enhancements to increase field of view and increase sensitivity to occupant detection (filtering building clutter). These imagers can be coupled with radio frequency and ultrasonic-based radar to enhance data collection at key occupant zone boundaries to improve accuracy. Standard filtering and estimation techniques from the image processing and computer vision communities are introduced to overcome the accuracy issues suffered by traditional PIR based sensing, especially when occupants remain relatively still. Accurate low-level counting of individuals can be achieved with minimal impact on privacy. As a result, the proposed occupancy detection method can work as a retrofit to enable real-time understanding of the building operational state and usage behavior. Sensor data obtained from real test building zones was used to test the efficacy of the method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Swarm intelligence–based distributed stochastic model predictive control for transactive operation of networked building clusters

To maximize potential energy and cost savings, networked clusters of local buildings are formed for energy transactions. Both centralized and distributed decision approaches were explored in past decades as a way to enable efficient transactive operations. However, online distributed stochastic transactive operation has been overlooked in the literature. To bridge gaps in the research, a bi-level distributed stochastic model predictive control framework was proposed to study the transactive operations of building clusters where a system-level agent is employed to coordinate multiple building agents at the subsystem level. The energy transaction is optimized by a marginal price-based particle swarm optimizer at the system level. Given the energy transaction decisions, each building can independently solve a scenario-based two-stage stochastic model to optimally dispatch the electricity and ancillary services for optimal energy performance. The effectiveness of the proposed framework and coordination algorithm are demonstrated in deterministic, stochastic, and online operations and compared to centralized decisions using several sets of experiments. Additionally, the proposed approach can realize autonomous transactive operation and be extended to community-level building clusters in a plug-and-play way.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Real time side-by-side experimental validation of energy and comfort performance of a zero net energy retrofit package for small commercial buildings

Making buildings zero-net energy (ZNE) is one of the major strategies for achieving carbon emission reduction goals. For this strategy to be successful, it entails a very significant reduction in energy use – 50% or more. In small commercial buildings, however, owners and building management teams usually have limited resources for identifying, analyzing, and procuring appropriate retrofit measures for reducing such use. An approach to overcome this limitation is the development of bundles of energy efficiency measures that can be presented to building owners/operators as a comprehensive package. The research presented in this paper focuses on an experimental evaluation of the impacts of a retrofit package developed for small office buildings in California. Performing this evaluation in a full-scale whole-building integrated systems test facility allowed a side-by-side evaluation in real time, against a reference case, of the impact of the retrofit package not only on energy use but also on visual and thermal comfort. Here, the retrofit package evaluated is comprised of a combination of HVAC, lighting (including daylighting), and plug load measures. The evaluation occurred at different times of the year in order to account for seasonal variations in environmental conditions, including solar angles and weather. The experimental facility allowed testing for two different façade orientations: south and west. Results show that the proposed ZNE retrofit package can save significant amounts of energy for small commercial buildings. During cooling-prevalent periods, total energy savings were 65% for south orientation and 68% for west orientation; during heating-prevalent periods total energy savings were 22% for south orientation and 25% for west orientation. Measurements indicate that the ZNE retrofit package resulted in small but not very significant changes in comfort levels for building occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Component-Level Analysis of Heating and Cooling Loads in the U.S. Residential Building Stock

The residential building sector accounts for a substantial portion of total energy consumption in the United States and offers a significant opportunity for energy reduction and decarbonization through improvements in energy efficiency. Heating and air conditioning are the primary contributors to residential energy usage and electricity system peak demand. However, due to the diversity of the housing stock and the complexity of factors affecting heating and cooling demand, identifying the relative contributions to heating and cooling loads poses challenges. To address this, we applied the ResStock analysis tool to simulate 550,000 building energy models, providing statistical representation of residential buildings in the contiguous United States. We introduced outputs that quantified the heating and cooling influence of different components of a home, such as air leakage, envelope components (ceilings, walls, windows, foundations), internal heat gains from people, lighting, plug loads, and duct losses and gains. Leveraging the granularity of ResStock, we present a dataset to enable deeper understanding of the contributors to heating and cooling loads as a function of housing characteristics such as location, envelope efficiency, and building type. This work aims to support prioritization of research and development and informed decision-making for residential building decarbonization.

building simulation↗

An economic and technical feasibility analysis of a dual-source heat pump using both the air and the ground

The study investigates the economic and technical performance of a novel dual-source heat pump (DSHP) compared with that of air-source heat pumps (ASHPs) and ground-source heat pumps (GSHPs). The DSHP can use both ambient air and the ground as a heat source or heat sink. It uses ambient air when its temperature is favorable for efficient heat pump operation. When the ambient temperature is too hot or cold, the ground source is used to retain high-efficiency heat pump operation. Since the DSHP can alternately use either the ground heat exchanger (GHE) or ambient air to meet the thermal load, the required size of GHE can be smaller than those of GSHPs. This study models the DSHP using a whole building energy simulation tool (EnergyPlus) coupled with a Python plug-in and Heat Pump Design Model (HPDM) to simulate its heating and cooling performance for a typical single-family home in 15 US climate zones. The required GHE size of the DSHP system is determined through simulations and compared with that of GSHPs. DSHP deployment can reduce electricity use compared to ASHPs, especially in cold climates where it shows a reduction of around 50%. When compared to GSHPs, DSHPs use 20%–40% more electricity in warm climates but consume around the same amount in moderate and colder climates. Since the DSHP can use air source when the ambient temperature is mild, the GHE size needed for the DSHP is about 40% less than that needed for GSHPs in hot climates and about 25% less in cold climates. In conclusion, the life cycle cost analysis shows that the DSHP is economically more feasible than ASHPs in colder regions and economically more feasible than GSHPs in hot and cold regions.

Dual-source heat pumps↗

Understanding the impacts of inorganic species in woody biomass for preprocessing and pyrolysis–A review

Woody biomass represents an abundant resource for sustainable biofuels, biochemicals, and bioproducts. Technologies for converting woody biomass have been established for decades, and research consistently highlights the critical role of inorganic species and ash plays in feedstock handling and conversion processes, including equipment plugging, corrosion, and catalyst deactivation. A thorough understanding of the variability, transport behavior, and downstream impact of inorganic species in woody biomass is essential for defining feedstock quality specifications and developing effective management strategies for conversion processes. This review compiles critical information in five main sections: 1) inorganic species concentration in woody biomass, based on anatomical fractions and their sources of variability; 2) technique features for quantifying inorganic elemental chemical analysis; 3) impacts of inorganic species on biomass preprocessing; 4) impacts of inorganic species on pyrolysis, and 5) mitigation strategies. Additionally, this review explores future challenges and opportunities in addressing the impacts of inorganic species on biomass quality. These insights aim to support the sustainable development of the biomass-to-bioenergy pipeline and ensure high-quality lignocellulosic feedstocks for efficient downstream conversions. The findings offer valuable guidance to policy makers, industry stakeholders, and researchers in developing effective strategies for managing inorganic species in woody biomass and fostering the sustainable processes for lignocellulosic biorefineries.

09 BIOMASS FUELS↗

New trends in solar: A comparative study assessing the attitudes towards the adoption of rooftop PV

The factors affecting the adoption of conventional solar PV have been broadly addressed in the recent literature. However, it is still to determine the public's acceptance of innovations of the traditional solar PV architecture. Building applied photovoltaic technology (BAPV) is a technological innovation that can be installed over existing building surfaces. This study compares an evaluation of the conscious and subconscious attitudinal, control and normative beliefs of American homeowners when randomly primed with two brochures depicting the purchasing, installation, and commissioning of solar PV systems, developed according to the characteristics of conventional and an adhesive “plug and play” BAPV system. The survey instrument (N = 400 survey participants) was designed in consonance to the Theory of Planned Behavior (TPB). When comparing the direct measures for each solar PV technology, no significant differences were found. This may indicate that for those unfamiliar with PV technology, placing an adhesive backing module on the roof is standard procedure and does not impact purchasing intentions. The evaluation further showed that unlike the subconscious control beliefs, social norms and attitudes have a significant impact on forming intentions to adopt solar PV. The implications of these findings for strategy, policy and future research are explored.

14 SOLAR ENERGY↗

How to support EV adoption: Tradeoffs between charging infrastructure investments and vehicle subsidies in California

Supporting the adoption of zero-emission vehicle (ZEVs), including plug-in electric vehicles (EVs), has become a priority for governments due to their ability to reduce petroleum demand, improve air quality, and reduce carbon dioxide (CO2) emissions. Optimal strategies to accelerate EV adoption must weigh the relative value of alternative policy mechanisms to consumers, including public charging infrastructure and vehicle purchase subsidies. We use a historically validated light-duty vehicle consumer choice tool, the ADOPT model, to simulate personal light-duty vehicle adoption and related emissions in California. ADOPT is updated to incorporate a quantification of the tangible value of public charging infrastructure, allowing us to simulate the impact of investments in public charging infrastructure and vehicle purchase subsidies under different scenarios. We show that both policies result in increased EV adoption, with the most effective policy varying depending on vehicle technology assumptions. Under conservative technology improvement assumptions, infrastructure investments are most effective in promoting EV sales and reducing CO2 emissions, while under optimistic technology improvement assumptions a combination of infrastructure and subsidies best supports EV sales and CO2 emission reductions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cooperative fault management for resilient integration of renewable energy

Cooperative fault management (CFM) is designed herein to control different types of renewable energy resources cooperatively during electrical faults. This paper studies systems with a high penetration of photovoltaic (PV) energy and wind energy. First, CFM leverages power converters of PV farms to boost the ride-through capability of nearby doubly-fed induction generators (DFIGs). By controlling PV farms’ output voltages to change smoothly during both fault initiation and fault clearance, the widely used crowbar in DFIGs is less likely to be activated. Crowbar activation adversely makes DFIGs lose controllability and absorb reactive power. The second contribution is the development of a software-defined CFM controller and a controller in-the-loop demonstration of the real-time performance of this optimization-based CFM. CFM capitalizes on distributed optimization formulation to enable flexibility, plug-and-play, and privacy-preserving. Computation time, however, is a major concern for optimization-based dynamics control. Here, real-time controller-in-the-loop simulation results show optimization-based CFM can output reference values around 60 ms and is quick enough for dynamic control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Areal sweep efficiency improvement by integrating preformed particle gel and low salinity water flooding in fractured reservoirs

The oil recovery from fractured reservoirs is usually low, which is usually caused by the existence of areal formation heterogeneity. Two existing enhanced oil recovery (EOR) technologies, low salinity water flooding (LSWF) and preformed particle gel treatment (PPG), have recently drawn great interest from the oil industry. We integrated both of these technologies into one process to improve both oil displacement and areal sweep efficiency. The objective of this study was to test how the integrated method could be used effectively to increase oil recovery and control water production. The semi-transparent five-spot models, which were made of sandstone cores and acrylic plates, were built. We investigated the effect of four parameters on the improvement of oil recovery and areal sweep efficiency of oil, including gel strength, water salinity, injection rate, and number of fractures. Two approaches were followed during core flooding, sequential mode and mixed mode. Here the result shows that PPG and LSW injected together as one mixture improved oil recovery factor more than the first approach. PPGs plugged the fractures and successfully improved areal sweep efficiency; however, they have little effect on displacement efficiency. LWSF increased displacement efficiency but had little or no effect on sweep efficiency. The integrated methods bypassed the limitations of each method when used individually and improved both displacement and sweep efficiency.

58 GEOSCIENCES↗