Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Phase control with two-beam interferometry method in a terahertz dielectric wakefield accelerator

High-gradient, beam-driven wakefield acceleration in THz structures is a promising technology for future free electron lasers and colliders. In this scheme, the main beam is accelerated by the wakefield of the high current drive beam. The time separation between the main and drive beams has to be chosen carefully to ensure that the main beam is in an accelerating phase of the drive's wakefield. THz accelerating structures provide high gradient acceleration due to their small apertures, but their phase control is difficult due to the picosecond-scale period. Here, we report on a wakefield acceleration experiment in a 460 GHz dielectric wakefield accelerator (DWA). The optimum phase of the main beam during the experiment is determined with a two-beam wakefield interferometry (TBI) measurement. This is performed without the measurement of the main and drive beam bunch lengths or their separation. In TBI, the interference of the wakefields produced by the drive and main beams is measured with an integrating THz detector. The TBI signal, as a function of separation between the drive and main beams, exhibits a minimum due to destructive interference of these wakefields, which corresponds to maximum acceleration of the main beam as is confirmed by the energy spectrometer measurement. The maximum energy gain of 0.8 MeV and maximum energy loss of 1.2 MeV for the main beam have been measured, which agrees well with theoretical predictions. Published by AIP Publishing.

43 PARTICLE ACCELERATORS↗

Sensitivity Analysis of X-ray Spectra from Scanning Electron Microscopes

The primary goal of this project is to evaluate x-ray spectra generated within a scanning electron microscope (SEM) to determine elemental composition of small samples. This will be accomplished by performing Monte Carlo simulations of the electron and photon interactions in the sample and in the x-ray detector. The elemental inventories will be determined by an inverse process that progressively reduces the difference between the measured and simulated x-ray spectra by iteratively adjusting composition and geometric variables in the computational model. The intended benefit of this work will be to develop a method to perform quantitative analysis on substandard samples (heterogeneous phases, rough surfaces, small sizes, etc.) without involving standard elemental samples or empirical matrix corrections (i.e., true standardless quantitative analysis).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cantilevered probe detector with piezoelectric element

A disclosed chemical detection system for detecting a target material, such as an explosive material, can include a cantilevered probe, a probe heater coupled to the cantilevered probe, and a piezoelectric element disposed on the cantilevered probe. The piezoelectric element can be configured as a detector and/or an actuator. Detection can include, for example, detecting a movement of the cantilevered probe or a property of the cantilevered probe. The movement or a change in the property of the cantilevered probe can occur, for example, by adsorption of the target material, desorption of the target material, reaction of the target material and/or phase change of the target material. Examples of detectable movements and properties include temperature shifts, impedance shifts, and resonant frequency shifts of the cantilevered probe. The overall chemical detection system can be incorporated, for example, into a handheld explosive material detection system.

47 OTHER INSTRUMENTATION↗

Cantilevered probe detector with piezoelectric element

A disclosed chemical detection system for detecting a target material, such as an explosive material, can include a cantilevered probe, a probe heater coupled to the cantilevered probe, and a piezoelectric element disposed on the cantilevered probe. The piezoelectric element can be configured as a detector and/or an actuator. Detection can include, for example, detecting a movement of the cantilevered probe or a property of the cantilevered probe. The movement or a change in the property of the cantilevered probe can occur, for example, by adsorption of the target material, desorption of the target material, reaction of the target material and/or phase change of the target material. Examples of detectable movements and properties include temperature shifts, impedance shifts, and resonant frequency shifts of the cantilevered probe. The overall chemical detection system can be incorporated, for example, into a handheld explosive material detection system.

47 OTHER INSTRUMENTATION↗

Cantilevered probe detector with piezoelectric element

A disclosed chemical detection system for detecting a target material, such as an explosive material, can include a cantilevered probe, a probe heater coupled to the cantilevered probe, and a piezoelectric element disposed on the cantilevered probe. The piezoelectric element can be configured as a detector and/or an actuator. Detection can include, for example, detecting a movement of the cantilevered probe or a property of the cantilevered probe. The movement or a change in the property of the cantilevered probe can occur, for example, by adsorption of the target material, desorption of the target material, reaction of the target material and/or phase change of the target material. Examples of detectable movements and properties include temperature shifts, impedance shifts, and resonant frequency shifts of the cantilevered probe. The overall chemical detection system can be incorporated, for example, into a handheld explosive material detection system.

47 OTHER INSTRUMENTATION↗

Cantilevered probe detector with piezoelectric element

A disclosed chemical detection system for detecting a target material, such as an explosive material, can include a cantilevered probe, a probe heater coupled to the cantilevered probe, and a piezoelectric element disposed on the cantilevered probe. The piezoelectric element can be configured as a detector and/or an actuator. Detection can include, for example, detecting a movement of the cantilevered probe or a property of the cantilevered probe. The movement or a change in the property of the cantilevered probe can occur, for example, by adsorption of the target material, desorption of the target material, reaction of the target material and/or phase change of the target material. Examples of detectable movements and properties include temperature shifts, impedance shifts, and resonant frequency shifts of the cantilevered probe. The overall chemical detection system can be incorporated, for example, into a handheld explosive material detection system.

Adams, Jesse D↗

Cantilevered probe detector with piezoelectric element

A disclosed chemical detection system for detecting a target material, such as an explosive material, can include a cantilevered probe, a probe heater coupled to the cantilevered probe, and a piezoelectric element disposed on the cantilevered probe. The piezoelectric element can be configured as a detector and/or an actuator. Detection can include, for example, detecting a movement of the cantilevered probe or a property of the cantilevered probe. The movement or a change in the property of the cantilevered probe can occur, for example, by adsorption of the target material, desorption of the target material, reaction of the target material and/or phase change of the target material. Examples of detectable movements and properties include temperature shifts, impedance shifts, and resonant frequency shifts of the cantilevered probe. The overall chemical detection system can be incorporated, for example, into a handheld explosive material detection system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Board of Regents of the Nevada System of Higher Education, on behalf of the University of Nevada, Reno

A disclosed chemical detection system for detecting a target material, such as an explosive material, can include a cantilevered probe, a probe heater coupled to the cantilevered probe, and a piezoelectric element disposed on the cantilevered probe. The piezoelectric element can be configured as a detector and/or an actuator. Detection can include, for example, detecting a movement of the cantilevered probe or a property of the cantilevered probe. The movement or a change in the property of the cantilevered probe can occur, for example, by adsorption of the target material, desorption of the target material, reaction of the target material and/or phase change of the target material. Examples of detectable movements and properties include temperature shifts, impedance shifts, and resonant frequency shifts of the cantilevered probe. The overall chemical detection system can be incorporated, for example, into a handheld explosive material detection system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cantilevered probe detector with piezoelectric element

A disclosed chemical detection system for detecting a target material, such as an explosive material, can include a cantilevered probe, a probe heater coupled to the cantilevered probe, and a piezoelectric element disposed on the cantilevered probe. The piezoelectric element can be configured as a detector and/or an actuator. Detection can include, for example, detecting a movement of the cantilevered probe or a property of the cantilevered probe. The movement or a change in the property of the cantilevered probe can occur, for example, by adsorption of the target material, desorption of the target material, reaction of the target material and/or phase change of the target material. Examples of detectable movements and properties include temperature shifts, impedance shifts, and resonant frequency shifts of the cantilevered probe. The overall chemical detection system can be incorporated, for example, into a handheld explosive material detection system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Irreversibility Line Measurement and Vortex Dynamics in High Magnetic Fields in Ni- and Co-Doped Iron Pnictide Bulk Superconductors

The de-pinning or irreversibility lines were determined by ac susceptibility, magnetization, radio-frequency proximity detector oscillator (PDO), and resistivity methods in Ba(Fe 0.92 Co 0.08 ) 2 As 2 ( T c = 23.2 K), Ba(Fe 0.95 Ni 0.05 ) 2 As 2 ( T c = 20.4 K), and Ba(Fe 0.94 Ni 0.06 ) 2 As 2 ( T c = 18.5 K) bulk superconductors in ac, dc, and pulsed magnetic fields up to 65 T. A new method of extracting the irreversibility fields from the radio-frequency proximity detector oscillator induction technique is described. Wide temperature broadening of the irreversibility lines, for any given combination of ac and dc fields, is dependent on the time frame of measurement. Increasing the magnetic field sweep rate (dH/dt) shifts the irreversibility lines to higher temperatures up to about dH/d t = 40,000 Oe/s; for higher dH/dt, there is little impact on the irreversibility line. There is an excellent data match between the irreversibility fields obtained from magnetization hysteresis loops, PDO, and ac susceptibility measurements, but not from resistivity measurements in these materials. Lower critical field vs. temperature phase diagrams are measured. Their very low values near 0 T indicate that these materials are in mixed state in nonzero magnetic fields, and yet the strength of the vortex pinning enables very high irreversibility fields, as high as 51 T at 1.5 K for the Ba(Fe 0.92 Co 0.08 ) 2 As 2 polycrystalline sample, showing a promise for liquid helium temperature applications.

36 MATERIALS SCIENCE↗

Chemical changes in thirdhand smoke associated with remediation using an ozone generator

Ozonation is a common remediation approach to eliminate odors from mold, tobacco and fire damage in buildings. Little information exists to: 1) assess its effectiveness; 2) provide guidance on operation conditions; and 3) identify potential risks associated with the presence of indoor ozone and ozonation byproducts. The goal of this study is to evaluate chemical changes in thirdhand smoke (THS) aerosols induced by high levels of ozone, in comparison with THS aerosols aged under similar conditions in the absence of ozone. Samples representing different stages of smoke aging in the absence of ozone, including freshly emitted secondhand smoke (SHS) and THS, were collected inside an 18-m 3 room-sized chamber over a period of 42 h after six cigarettes were consumed. The experiments involved collection and analysis of gas phase species including volatile organic compounds (VOCs), volatile carbonyls, semivolatile organic compounds (SVOCs), and particulate matter. VOC analysis was carried out by gas chromatography/mass spectrometry with a thermal desorption inlet (TD-GC/MS), and volatile carbonyls were analyzed by on-line derivatization with dinitrophenylhydrazine (DNPH), followed by liquid chromatography with UV/VIS detection. SVOCs were extracted from XAD-coated denuders and Teflon-coated fiberglass filters in the absence of ozone. In those extracts, tobacco-specific nitrosamines (TSNAs) and other SVOCs were analyzed by gas chromatography with positive chemical ionization-triple quadrupole mass spectrometric detection (GC/PCI-QQQ-MS), and polycyclic aromatic hydrocarbons (PAHs) were quantified by gas chromatography with ion trap mass spectrometric detection (GC/IT-MS) in selected ion monitoring mode. Particulate matter concentration was determined gravimetrically. In a second experiment, a 300 mg h -1 commercial ozone generator was operated during 1 h, one day after smoke was generated, to evaluate the remediation of THS by ozonation. VOCs and volatile carbonyls were analyzed before and after ozonation. Extracts from fabrics that were exposed in the chamber before and after ozonation as surrogates for indoor furnishings were analyzed by GC/IT-MS, and aerosol size distribution was studied with a scanning mobility particle sizer. Ozone concentration was measured with a photometric detector. An estimated 175 mg ozone reacted with THS after 1 h of treatment, corresponding to 58% of the total O 3 released during that period. Fabric-bound nicotine was depleted after ozonation, and the surface concentration of PAHs adsorbed to fabric specimens decreased by an order of magnitude due to reaction with ozone, reaching pre-smoking levels. These results suggest that ozonation has the potential to remove harmful THS chemicals from indoor surfaces. However, gas phase concentrations of volatile carbonyls, including formaldehyde, acetaldehyde and acetone were higher immediately after ozonation. Ultrafine particles (UFP, in most cases with size <60 nm) were a major ozonation byproduct. UFP number concentrations peaked shortly after ozonation ended, and remained at higher-than background levels for several hours. Based on these results, minimum re-entry times after ozone treatment were predicted for different indoor scenarios. Clearly defining re-entry times can serve as a practical measure to prevent acute exposures to ozone and harmful ozonation byproducts after treatment. This study evaluated potential benefits and risks associated with THS remediation using ozone, providing insights into this technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of inclusive and differential cross sections in the H → ZZ * → 4ℓ decay channel in pp collisions at $ \sqrt{s}=13 $ TeV with the ATLAS detector

Inclusive and differential fiducial cross sections of Higgs boson production in proton-proton collisions are measured in the H → ZZ * → 4ℓ decay channel. The proton-proton collision data were produced at the Large Hadron Collider at a centre-of-mass energy of 13 TeV and recorded by the ATLAS detector in 2015 and 2016, corresponding to an integrated luminosity of 36.1 fb –1 . The inclusive fiducial cross section in the H → ZZ * → 4ℓ decay channel is measured to be 3.62±0.50(stat) –0.20 +0.25 (sys) fb, in agreement with the Standard Model prediction of 2.91 ± 0.13 fb. The cross section is also extrapolated to the total phase space including all Standard Model Higgs boson decays. Several differential fiducial cross sections are measured for observables sensitive to the Higgs boson production and decay, including kinematic distributions of jets produced in association with the Higgs boson. Good agreement is found between data and Standard Model predictions. Here, the results are used to put constraints on anomalous Higgs boson interactions with Standard Model particles, using the pseudo-observable extension to the kappa-framework.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of ZZ production cross-sections in the four-lepton final state in pp collisions at $\sqrt{s}$ = 13.6 TeV with the ATLAS experiment

This paper reports cross-section measurements of ZZ production in pp collisions at $\sqrt{s}$ = 13.6 TeV at the Large Hadron Collider. The data were collected by the ATLAS detector in 2022, and correspond to an integrated luminosity of 29 fb -1 . Events in the ZZ → 4ℓ(ℓ = e, μ) final states are selected and used to measure the inclusive and differential cross-sections in a fiducial region defined close to the analysis selections. The inclusive cross-section is further extrapolated to the total phase space with a requirement of 66 < m Z < 116 GeV for both Z bosons, yielding 16.8 ± 1.1 pb. The results are well described by the Standard Model predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Surface x-ray diffraction of complex metal oxide surfaces and interfaces--a new era

The availability of high-brilliance hard x-ray synchrotron radiation and the advent of novel photon counting area detectors have brought surface x-ray diffraction (SXRD) into a new era. It is now possible to record large numbers of structure factors with much improved reliability within reasonable beamtime durations. As a result, structural determination of the surfaces and interfaces of complex crystallographic systems and heterostructures has now become feasible, especially in conjunction with phase-retrieval methods. It is thereby hoped that detailed structural information will shed light on the unusual physical properties of these systems. Complex metal oxide systems investigated at the Materials Science beamline of the Swiss Light Source, including the surface of SrTiO{sub 3}, the interface between LaAlO{sub 3} and SrTiO{sub 3}, and the structure of YBa{sub 2}Cu{sub 3}O{sub 7} grown on NdGaO{sub 3}, SrTiO{sub 3}, and (LaSr)(AlTa)O{sub 3} will be presented as examples of what is now possible using SXRD.

36 MATERIALS SCIENCE↗

Analyzer-based phase-contrast imaging system using a micro focus x-ray source

Here we describe a new in-laboratory analyzer based phase contrast-imaging (ABI) instrument using a conventional X-ray tube source (CXS) aimed at bio-medical imaging applications. Phase contrast-imaging allows visualization of soft tissue details usually obscured in conventional X-ray imaging. The ABI system design and major features are described in detail. The key advantage of the presented system, over the few existing CXS ABI systems, is that it does not require high precision components, i.e., CXS, X-ray detector, and electro-mechanical components. To overcome a main problem introduced by these components, identified as temperature stability, the system components are kept at a constant temperature inside of three enclosures, thus minimizing the electrical and mechanical thermal drifts. This is achieved by using thermoelectric (Peltier) cooling/heating modules that are easy to control precisely. For CXS we utilized a microfocus X-ray source with tungsten (W) anode material. In addition the proposed system eliminates tungsten's multiple spectral lines by selecting monochromator crystal size appropriately therefore eliminating need for the costly mismatched, two-crystal monochromator. The system imaging was fine-tuned for tungsten Kα{sub 1} line with the energy of 59.3 keV since it has been shown to be of great clinical significance by a number of researchers at synchrotron facilities. In this way a laboratory system that can be used for evaluating and quantifying tissue properties, initially explored at synchrotron facilities, would be of great interest to a larger research community. To demonstrate the imaging capability of our instrument we use a chicken thigh tissue sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic in J-PARC/Hyper-K

The Hyper-Kamiokande (Hyper-K) detector is a next generation underground water Chrenkov detector. The J-PARC to Hyper-K experiment has good potential for precision measurements of neutrino oscillation parameters and discovery reach for CP violation in the lepton sector. With a total exposure of 10 years to a neutrino beam produced by the 750 kW J-PARC proton synchrotron, it is expected that the CP phase δ can be determined to better than 18 degree for all possible values of δ if sin{sup 2} 2θ{sub 13} > 0.03 and the mass hierarchy is known. Control of systematic uncertainties is critical to make maximum use of the Hyper-K potential. Based on learning from T2K experience, a strategy to reduce systematic uncertainties in J-PARC/Hyper-K are developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗