Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Improved limits on n → n ' transformation from the Spallation Neutron Source

Conversions between neutrons n and dark matter candidate sterile neutrons n' have been proposed as a mechanism for baryon number $\mathscr{B}$ violation. In the case that there is a small mass difference Δ⁢m between the n and the n' states, oscillations can be induced by compensating for Δ⁢m with a magnetic field. A search for such neutron oscillations was performed at the Spallation Neutron Source by looking for anomalous neutron transmission through a strongly absorbing cadmium wafer inside of a 6.6 T magnet. The approach described here saw no regenerated neutrons above background, which provides an improved limit for neutron–sterile neutron transformations for a range of Δ⁢m between 0.1 and 1000 neV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new online detector for estimation of peripheral neutron equivalent dose in organ

Purpose: Peripheral dose in radiotherapy treatments represents a potential source of secondary neoplasic processes. As in the last few years, there has been a fast-growing concern on neutron collateral effects, this work focuses on this component. A previous established methodology to estimate peripheral neutron equivalent doses relied on passive (TLD, CR39) neutron detectors exposed in-phantom, in parallel to an active [static random access memory (SRAMnd)] thermal neutron detector exposed ex-phantom. A newly miniaturized, quick, and reliable active thermal neutron detector (TNRD, Thermal Neutron Rate Detector) was validated for both procedures. This first miniaturized active system eliminates the long postprocessing, required for passive detectors, giving thermal neutron fluences in real time. Methods: To validate TNRD for the established methodology, intrinsic characteristics, characterization of 4 facilities [to correlate monitor value (MU) with risk], and a cohort of 200 real patients (for second cancer risk estimates) were evaluated and compared with the well-established SRAMnd device. Finally, TNRD was compared to TLD pairs for 3 generic radiotherapy treatments through 16 strategic points inside an anthropomorphic phantom. Results: The performed tests indicate similar linear dependence with dose for both detectors, TNRD and SRAMnd, while a slightly better reproducibility has been obtained for TNRD (1.7% vs 2.2%). Risk estimates when delivering 1000 MU are in good agreement between both detectors (mean deviation of TNRD measurements with respect to the ones of SRAMnd is 0.07 cases per 1000, with differences always smaller than 0.08 cases per 1000). As far as the in-phantom measurements are concerned, a mean deviation smaller than 1.7% was obtained. Conclusions: The results obtained indicate that direct evaluation of equivalent dose estimation in organs, both in phantom and patients, is perfectly feasible with this new detector. This will open the door to an easy implementation of specific peripheral neutron dose models for any type of treatment and facility.

60 APPLIED LIFE SCIENCES↗

Production and applications of neutrons using particle accelerators

Advances in neutron science have gone hand in hand with the development and of particle accelerators from the beginning of both fields of study. Early accelerator systems were developed simply to produce neutrons, allowing scientists to study their properties and how neutrons interact in matter, but people quickly realized that more tangible uses existed too. Today the diversity of applications for industrial accelerator-based neutron sources is high and so to is the actual number of instruments in daily use is high, and they serve important roles in the fields where they're used. This chapter presents a technical introduction to the different ways particle accelerators are used to produce neutrons, an historical overview of the early development of neutron-producing particle accelerators, a description of some current industrial accelerator systems, narratives of the fields where neutron-producing particle accelerators are used today, and comments on future trends in the industrial uses of neutron producing particle accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Some Notes on Neutron Up-Scattering and the Doppler-Broadening of High-Z Scattering Resonances

When neutrons are scattered by target nuclei at elevated temperatures, it is entirely possible that the neutron will actually gain energy (i.e., up-scatter) from the interaction. This phenomenon is in addition to the more usual case of the neutron losing energy (i.e., down-scatter). Furthermore, the motion of the target nuclei can also cause extended neutron down-scattering, i.e., the neutrons can and do scatter to energies lower than predicted by the simple asymptotic models. In recent years, more attention has been given to temperature-dependent scattering cross sections for materials in neutron multiplying systems. This has led to the inclusion of neutron up-scatter in deterministic codes like Partisn and to free gas scattering models for material temperature effects in Monte Carlo codes like MCNP and cross section processing codes like NJOY. The free gas scattering models have the effect of Doppler Broadening the scattering cross section output spectra in energy and angle. The current state of Doppler-Broadening numerical techniques used at Los Alamos for scattering resonances will be reviewed, and suggestions will be made for further developments. The focus will be on the free gas scattering models currently in use and the development of new models to include high-Z resonance scattering effects. These models change the neutron up-scattering behavior.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Fission-like Neutron Spectrum Shaping Assembly based on D-T Generator

For nearly five decades, 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. While there appear to be no other radionuclide neutron sources that would match the 252 Cf performance characteristics, all of them, including 252 Cf, present similar concerns in terms of hazards, safety, and security. As a possible solution to this issue, the Pacific Northwest National Laboratory (PNNL) developed a low-risk, cost-efficient alternative to produce fission-like spectra based on commercially available deuterium-tritium (D-T) neutron generators. The alternative of producing a fission-like neutron spectrum without any fissionable materials or beryllium would enable the nuclear facilities across the entire complex to eliminate their reliance on high intensity 252 Cf sources for nuclear safety and radiation protection applications, substantially reducing risks and associated costs. This report describes efforts of designing the spectrum shaping assembly, its construction and characterization of the neutron field produced. Performance of this newly developed D-T generator based neutron field is demonstrated via calibration of a criticality detector, neutron survey instruments, and personal dosimeters verified against current standardized fields produced by 252 Cf spontaneous fission sources.

42 ENGINEERING↗

Report on the "Symposium on Advancements in Simulating Neutron Scattering Instruments and Experiments"

An international group of researchers gathered for the “Symposium on Advancements in Simulating Neutron Scattering Instruments and Experiments” at Oak Ridge National Laboratory (ORNL) on October 29- 30, 2024. The symposium highlighted state-of-the-art advancements in neutron scattering instrument simulations and the development of digital twins for scattering instruments. This document summarizes the recurring themes from the 19 talks and discussions. A key focus was on the role of neutronics simulations in the design, analysis, and performance optimization of neutron instruments. Presentations featured the most widely used software packages, such as McStas, McVine, Vitess, and MCNP. Another major theme addressed the analysis and interpretation of experimental neutron data, where materials models and simulations play a critical role. Talks on relevant software tools, including NCrystal, OCLimax, and Paradyse, were delivered by their respective developers. During the symposium, both talks and breakout sessions explored strategies to enhance the interplay between neutronics simulations and materials models. A key question emerged: How can we develop a RealTime Explainable Digital Twin of a neutron scattering experiment? Discussions include the idea that the Digital Twin concept has implications for instrument control and testing. Through this symposium, we gained valuable insights into the challenges and requirements for developing a Real-Time Explainable Digital Twin of a neutron scattering experiment. The discussions and presentations paved the way for future innovations in this rapidly advancing field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo modeling and analyses of YALINA-booster subcritical assembly part 1: analytical models and main neutronics parameters.

This study was carried out to model and analyze the YALINA-Booster facility, of the Joint Institute for Power and Nuclear Research of Belarus, with the long term objective of advancing the utilization of accelerator driven systems for the incineration of nuclear waste. The YALINA-Booster facility is a subcritical assembly, driven by an external neutron source, which has been constructed to study the neutron physics and to develop and refine methodologies to control the operation of accelerator driven systems. The external neutron source consists of Californium-252 spontaneous fission neutrons, 2.45 MeV neutrons from Deuterium-Deuterium reactions, or 14.1 MeV neutrons from Deuterium-Tritium reactions. In the latter two cases a deuteron beam is used to generate the neutrons. This study is a part of the collaborative activity between Argonne National Laboratory (ANL) of USA and the Joint Institute for Power and Nuclear Research of Belarus. In addition, the International Atomic Energy Agency (IAEA) has a coordinated research project benchmarking and comparing the results of different numerical codes with the experimental data available from the YALINA-Booster facility and ANL has a leading role coordinating the IAEA activity. The YALINA-Booster facility has been modeled according to the benchmark specifications defined for the IAEA activity without any geometrical homogenization using the Monte Carlo codes MONK and MCNP/MCNPX/MCB. The MONK model perfectly matches the MCNP one. The computational analyses have been extended through the MCB code, which is an extension of the MCNP code with burnup capability because of its additional feature for analyzing source driven multiplying assemblies. The main neutronics parameters of the YALINA-Booster facility were calculated using these computer codes with different nuclear data libraries based on ENDF/B-VI-0, -6, JEF-2.2, and JEF-3.1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NEUTRON MEASUREMENTS AT HANFORD’S PLUTONIUM FINISHING PLANT

The Pacific Northwest National Laboratory (PNNL) conducted neutron measurements at Hanford’s Plutonium Finishing Plant (PFP). The measurements were performed to evaluate the performance of the Hanford Standard Dosimeter (HSD) and the 8816 TLD component of the Hanford Combination Neutron Dosimeter (HCND) in the neutron fields responsible for worker neutron exposures. For this study, TEPC detectors and multisphere spectrometers were used to measure neutron dose equivalent rate, and multispheres were used to measure average neutron energy. Water-filled phantoms holding Hanford dosimeters were positioned at each measurement location. The phantoms were positioned in the same location where a multisphere measurement was taken and TEPCs were also positioned there. Plant survey meters were also used to measure neutron dose rates at all locations. Three measurement locations were chose near the HC-9B glovebox in room 228A of Building 234-5. The multisphere spectrometers measured average neutron energies in the range of 337 to 555 keV at these locations. Personal dose equivalent, Hp(10)n, as measured by the multisphere and TEPC, ranged from 2.7 to 9.7 mrem/h in the three locations. Effective dose assuming a rotational geometry (EROT) was substantially lower than Hp(10), ranging from 1.3 to 3.6 mrem/h. These values were lower than the reported values from dosimeters exposed on a rotating phantom. Effective dose assuming an AP geometry (EAP) was also substantially lower than Hp(10), ranging from 2.3 to 6.5 mrem/h. These values were lower than the reported values from the dosimeters on slab phantoms. Since the effective dose values were lower than reported values from dosimeters, the dosimeters were shown to be conservative estimates of the protection quantities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Front-End Design for SiPM-Based Monolithic Neutron Double Scatter Imagers

Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to enable emission imaging of neutron sources. Due to the relatively low coincidence detection efficiency of fast neutrons in organic scintillator arrays, imaging efficiency for double scatter cameras can also be low. One method to realize significant gains in neutron coincidence detection efficiency is to develop neutron double scatter detectors which employ monolithic blocks of organic scintillator, instrumented with photosensor arrays on multiple faces to enable 3D position and multi-interaction time pickoff. Silicon photomultipliers (SiPMs) have several advantageous characteristics for this approach, including high photon detection efficiency (PDE), good single photon time resolution (SPTR), high gain that translates to single photon counting capabilities, and ability to be tiled into large arrays with high packing fraction and photosensitive area fill factor. However, they also have a tradeoff in high uncorrelated and correlated noise rates (dark counts from thermionic emissions and optical photon crosstalk generated during avalanche) which may complicate event positioning algorithms. We have evaluated the noise characteristics and SPTR of Hamamatsu S13360-6075 SiPMs with low noise, fast electronic readout for integration into a monolithic neutron scatter camera prototype. The sensors and electronic readout were implemented in a small-scale prototype detector in order to estimate expected noise performance for a monolithic neutron scatter camera and perform proof-of-concept measurements for scintillation photon counting and three-dimensional event positioning.

47 OTHER INSTRUMENTATION↗

Differential neutron energy spectra measured on spacecraft in low Earth orbit

Two methods for measuring neutrons in the range from thermal energies to dozens of MeV were used. In the first method, alpha-particles emitted from the 6Li(n,alpha)T reaction are detected with the help of plastic nuclear track detectors, yielding results on thermal and resonance neutrons. Also, fission foils are used to detect fast neutrons. In the second method, fast neutrons are recorded by nuclear photographic emulsions (NPE). The results of measurements on board various satellites are presented. The neutron flux density does not appear to correlate clearly with orbital parameters. Up to 50% of neutrons are due to albedo neutrons from the atmosphere while the fluxes inside the satellites are 15-20% higher than those on the outside. Estimates show that the neutron contribution to the total equivalent radiation dose reaches 20-30%.

Cosmos 1887 Project↗

New Pulsed Neutron Die-Away Experiments in Light Water

Thermal neutron scattering laws are important data for many nuclear science and engineering applications, especially criticality safety. Recently, pulsed-neutron die-away experiments have been proposed and used as an experiment to validate thermal neutron scattering laws. These experiments involve irradiating a target moderating material with pulses of neutrons from a neutron generator. The physics of thermal scattering greatly affect how the neutron population in the target exponentially decays via absorption and leakage. Herein, we present experimental results from a new pulsed-neutron die-away experiment of light water that was performed at Lawrence Livermore National Laboratory. The experiments were done with cylindrical targets of varying dimensions to modulate the experiment’s sensitivity to thermal scattering and to absorption. We compare the measured integral parameter of the experiment to simulations with MCNP6.2 ® and to past experiments in literature. The integral parameters that were more sensitive to TSLs showed a larger bias. This validation study is known to have errors because the model of the experiment lacks key features about the detectors and neutron generator. These features will be included in the final benchmark evaluation of the experiment which will be submitted to the International Criticality Safety Benchmark Evaluation Project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiogenic lead with dominant content of {sup 208}Pb: New coolant and neutron moderator for innovative nuclear reactors

The advantages of radiogenic lead with dominant content of {sup 208}Pb as a reactor coolant with respect to natural lead are caused by unique nuclear properties of {sup 208}Pb which is a double-magic nucleus with closed proton and neutron shells. This results in significantly lower micro cross section and resonance integral of radiative neutron capture by {sup 208}Pb than those for numerous light neutron moderators. The extremely weak ability of {sup 208}Pb to absorb neutrons results in the following effects. Firstly, neutron moderating factor (ratio of scattering to capture cross sections) is larger than that for graphite and light water. Secondly, age and diffusion length of thermal neutrons are larger than those for graphite, light and heavy water. Thirdly, neutron lifetime in {sup 208}Pb is comparable with that for graphite, beryllium and heavy water what could be important for safe reactor operation. The paper presents some results obtained in neutronics and thermal-hydraulics evaluations of the benefits from the use of radiogenic lead with dominant content of {sup 208}Pb instead of natural lead as a coolant of fast breeder reactors. The paper demonstrates that substitution of radiogenic lead for natural lead can offer the following benefits for operation of fast breeder reactors. Firstly, improvement of the reactor safety thanks to the better values of coolant temperature reactivity coefficient and, secondly, improvement of some thermal-hydraulic reactor parameters. Radiogenic lead can be extracted from thorium sludge without isotope separation as {sup 208}Pb is a final isotope in the decay chain of {sup 232}Th. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

YAP:Ce scintillator characteristics for neutron detection

YAP:Ce (YAlO{sub 3}:Ce{sup +}, Yttrium Aluminum Perovskite, Ce{sup +} doped) crystals with appropriate converters seem like prospective scintillators for neutron detection. An important aspect for neutron detection with inorganic scintillators is the ability to discriminate neutron radiation from gamma radiation by pulse height of signals. For a detailed measurement of the aspect, a YAP:Ce crystal scintillator with lithium or hydrogen converters and a photomultiplier was used. A plutonium-beryllium neutron source and horizontal neutron channel beams of the LVR-15 research reactor were used as neutron sources. The measurement confirmed the possibility to use the YAP:Ce scintillator for neutron radiation detection. The degree of discrimination between neutron and gamma radiation for different detection configurations was studied. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring alpha eigenvalue of a subcritical system by a intense pulsed neutron source

Intense-Pulsed-Neutron-Source (IPNS) technique is a new approach to measure the subcriticality of a reactor system, which has been theoretically analyzed by us while not been verified in experiment in other reference. In INPS technique the reactivity is derived via the system response to a prompt pulsed neutron source. The method utilizes very intense neutron pulses (about 1010 neutrons/pulse) with the duration ranging from 10 ns to 100 ns, which are generated by the dense plasma focus (DPF) device filled with pure DT mixture as the working gas. The neutron pulse in high intensity provides the opportunity to measure the signal using a scintillator and a photo-multiplier tube (PMT) (the intense pulse radiation measure method) with the flight distance of only twenty centimeters. The attenuation of the dense plasma focus device must be faster than the subcritical system so that the attenuation of the system can be researched. In this paper, after a neutron pulse is injected into the subcritical reactor, the subcriticality is determined by measuring the instantaneous characteristics of the leaking reactor neutron. The Monte Carlo analysis shows that, with the linear arrangement of the dense plasma focus, the subcritical system and the detector, the signal-to-noise ratio at the measure point meets the investigate requirement, in which the 14 MeV neutrons are attenuated by the subcritical system. The detector is close with the subcritical system to reduce the influence of the outer background and the spread of time-of-flight of the neutrons. The measure system utilizing gated detection technology is characterized with fast attenuation time and large linear current, the a value obtained with this method is 2.05 μs{sup -1} while the measurements using the {sup 252}Cf stochastic pulsed source method and the Rossi-a method were 2.18μs{sup -1} and 2.16μs{sup -1}.It showed that the measured result obtained with dense plasma focus instantaneous pulsed source is consistent with those obtained with the other two traditional methods. This new method utilized only a single-shot pulse to determine the a value of the reactor system. Therefore, this quick measure method is recommendable. The influence caused by energy response of the detector should been taken into account since the measured result reflects the time behavior of group particle. The influence is discussed preliminarily in this paper. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Challenges and Recent Developments of Neutron Non-Destructive Assay with UO{sub 2}F{sub 2}-Bearing Materials - 17336

In the enrichment process of an operating Gaseous Diffusion Plant (GDP), such as the Portsmouth and Paducah facilities, UF6 gas will immediately hydrolyze forming the chemical compound UO{sub 2}F{sub 2} (Uranyl Fluoride). This mostly happens in Alumina (Al{sub 2}O{sub 3}) traps where the UF6 adsorbs to moistened Alumina pellets forming a UO{sub 2}F{sub 2} layer around the pellet. Similarly, NaF.UF{sub 6} absorption traps produce the complex Na{sub 2}UF{sub 8} which also hydrolyzes when exposed to moist air. UO{sub 2}F{sub 2} can also be formed in many other processes where UF6 gas comes into contact with moisture within structures and objects such as pipes, converters compressors and coolers. When the structures are refurbished, or designated for D and D, UO{sub 2}F{sub 2}-bearing objects are generated both in situ and ex situ requiring fissile (U-235) characterization. In addition, ex situ waste streams are generated when UO{sub 2}F{sub 2}-bearing materials are placed in drummed or boxed waste containers. Gamma spectroscopy Non-Destructive Assay (NDA) is commonly utilized to characterize UO{sub 2}F{sub 2}-bearing waste but generally has high associated Total Measurement Uncertainties (TMU's) and, in some cases, Data Quality Objectives (DQO's) cannot be met. In addition, high UO{sub 2}F{sub 2} mass loadings, such as hold-up materials, require gamma modeling when infinitely thick to the Uranium energy lines. A common neutron NDA technique, or method, is to exploit the neutrons generated from the F-19(a, n)Na-22 reaction which has an appreciable reaction cross-section. The isotopes of Uranium are a-emitters, and, in particular, U-234 has a significantly higher a-decay reaction cross-section leading to a significant relative neutron Specific Activity (nSA). Neutron NDA is appealing since, in some cases, it has potentially lower TMU's than gamma NDA and neutron detector slabs facilitate surrounding large, complex-shaped, objects. Characterizing UO{sub 2}F{sub 2}-bearing waste for fissile content using neutrons generated from U-234, requires the U-235/U-234 ratio as well as the enrichment as well as the corresponding nSA's. It is also noted that U-238 has a considerable, relative, spontaneous fission nSA and this is a higher concern for low-enrichments where the mass of U-238 dominates. Additional neutron interfering elements include cosmic-ray induced spallation within the objects and background from other, in situ, UO{sub 2}F{sub 2}-bearing objects. In this paper we present the challenges and recently developed hardware and algorithmic strategies for quantifying fissile mass both in situ and ex situ using neutron NDA that works in conjunction to gamma spectroscopy NDA, or process knowledge, for objects and drummed/boxed waste containing UO{sub 2}F{sub 2}-bearing materials leading to minimal TMU's and achievable DQO's. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recent Progress on the PNL Accelerator-Based Intense Fusion Neutron Source

Phoenix Nuclear Labs (PNL) has developed a full line of accelerator-based neutron generators. This paper describes the highest yield DD fusion-based system. This device utilizes a microwave ion source (MWS), 300 kV DC accelerator, magnetic solenoid focus element, differential pumping system, and gaseous deuterium target to achieve DD neutron yields of 3x10{sup 11} n/s. Lower-yield variations of the device have been built using variable voltages and a solid titanium target, and design for a DT version of the gas target system is underway that will increase neutron yield to 5x10{sup 13} n/s. PNL has delivered a number of systems to government and commercial customers and has identified a number of longer-term commercial applications for this high-yield neutron generator. These include medical isotope production, neutron radiography, active interrogation for explosives and SNM detection, and Cf-252 replacement. Most applications require the development of specialized moderator assemblies and fixtures to meet customer requirements. A photograph of the neutron generator prototype is provided in Figure 1. This state-of-the-art neutron generator technology is essential for many applications of critical global importance including neutron radiography, medical isotope production, detection of explosives and nuclear material, materials characterization, and others. The presentation will discuss these applications and recent progress made on the base accelerator technology. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Comparing Thick Target Neutron Yield Calculations for Alphas on F-19 using MCNP6 1.1 Beta with TENDL 2012 Libraries

Because of the heritage of MCNPX, the first production release of MCNP6{sup TM} used physics models, instead of ACE (A Compact Evaluated Nuclear Data File) formatted libraries, for simulating the transport of alpha particles at all energies, as MCNPX could not yet read ACE formatted light ion libraries. For non-Coulombic interactions, the physics models have suggested minimums of ∼ 20-200 MeV. The first production release of MCNP6, MCNP6{sup TM} 1.0, was still capable of transporting alphas to low energies; however, the physics models resulted in poor prediction of inelastic reactions at energies below the suggested minimums. This poorer prediction at low energies resulted in orders of magnitude lower neutron yields for events resulting from light ion interactions at low energies. For example, F-19(α,n)Na-22 from U-234 decay in UF{sub 6} produced poor neutron production results. Modeling these types of interactions correctly is vital for signal analysis for nonproliferation safeguards and nuclear security as well as for correctly characterizing source terms for radiation protection and shielding calculations. The TALYS computer code was developed to simulate nuclear reactions involving neutrons, photons, protons, deuterons, tritons, alphas and He-3 particles, in the 1 keV - 200 MeV energy range. TENDL is a nuclear data library, which provides the output of the TALYS nuclear model code system for direct use in applications (i.e. ACE formatted cross sections). Since 2008, TENDL had publicly provided ACE formatted libraries for alpha transport; however, not until the release of MCNP6{sup TM} 1.1 beta, had MCNP6 publicly possessed the capability to read such libraries. At the Radiation Protection and Shielding Division topical meeting in 2014, initial testing of MCNP6 1.1 beta showed that MCNP6 using TENDL 2012 resulted in poor prediction when compared to the compilation of experiment data provided in R. Heaton et al. Further comparisons for PuBe sources, using the MCNP6 1.1 beta spontaneous decay alpha feature coupled with alpha transport, were also given in the winter American Nuclear Society meeting in 2014, where the results showed large discrepancies with measured data. For F-19(α,n)Na-22 interactions, the R. Heaton et al. paper is a conglomeration of several important references; and the data provided by R. Heaton et al. used a numerical fit of the excitation function provided by Norman et al.. Norman et al. has recently published their (α,n) thick target yield data for PbF{sub 2} in tabular form, backing out the thick target yields of F-19(α,n)Na-22 and computing F{sub 2} and UF{sub 6} thick target neutron yields (as supplements to the PbF{sub 2} data). Here we compared measured thick target yields of E. B. Norman et al. to MCNP6 1.1 beta using TENDL 2012 libraries. Deterministically backing out the thick target yield from measured values involves using the stopping power. MCNP uses either the SPAR code or an interpolation of the Spar code and Bethe-Boch formula for computing stopping powers. As a result one may believe that these separate methods will arrive at separate thick target yields independent of the production cross section. In our MCNP calculations, we simulated the alpha until the alpha completely stopped in the medium. The energy loss in the condensed history algorithm is not continuous but discrete and related to the stopping powers. Because the neutron production yield is energy dependent, the energy loss dictates the emission of secondary neutrons; and therefore the difference in stopping powers used may have some slight effect on the yield difference. For this study, we chose to use the default condensed history algorithm setup, while future studies should address tightening steps in the condensed history algorithm to prove whether or not choice of stopping power actually matters. The fact that all 5 evaluated isotopic compositions resulted in different thick target yield percent differences does warrant this type of investigation. A typical user may not be only interested in integral emission, taking 10 s to 100 s of processor hours to simulate, but rather a timely generation of the spectra. Such an application would require biasing the production of secondaries from alpha sources such that millions of secondaries could be produced, emulating a converged energy dependent spectra. Neutron production biasing from alpha sources does not currently exist; however, developing a biasing algorithm for neutron production from alpha sources should be investigated in the future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Fusion Neutronics Methodology, Software, and Testing Facility in FDS Team

Fusion neutronics including methodology, software, experiments, etc. is studied concerning the generation, utilizing and protection of neutrons in fusion facilities. Achievements have been made in the past decades to solve the new problems fusion neutronics. However there is still some way to go such as following. Automatic modeling method based on CAD has been developed to avoid the heavy burden of manual geometry description. The pre-processing costs much time to simplify the CAD model for converting to Constructive Solid Geometry (CSG), 2D or 3D mesh based geometry. This problem has become a new focus. Deep penetration of radiation shielding is notable problem for fusion. Adaptive variance reduction methods such as Consistent Adjoint Driven Importance Sampling (CADIS) were developed to accelerate convergence. However the gap still exists between engineering requirements and current methodology. The geometry simplification, homogenizing based tally, error in nuclear data and error propagation in coupled calculation, etc., causes considerable uncertainty, which leads to 'safety factor' applied in simulation results to achieve required safety margin. It can significantly raise the cost and even makes it impractical to initiate the fusion facilities. Uncertainty qualification, error analysis and error propagation problem should be studied. New methodology and software should be validated. For example the (n,p), (n,a), (n,t) cross section of Cu, Fe, W, Ni which is important for evaluation of material radiation damage is absent. The validation of neutronics properties of special components such as first wall, blanket and coil are needed. The D-T fusion neutron generator can directly represent the neutron environment in fusion reactors. However the neutron yield is several orders of magnitudes lower than requirements. To resolve obstacles in fusion neutronics, broad improvements of methodology, software and testing facility have been achieved by FDS Team in recent years and the main progress was introduced in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗