Pre-Sodiated Ti3C2Tx MXene Structure and Behavior as Electrode for Sodium-Ion Capacitors
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Here, the oxidation of boride and carbide-based ultra-high-temperature ceramics is the primary limiting factor for their use as aerodynamic surfaces. Understanding the behaviour of the oxides that can result from oxidation of metal borides and carbides at very high temperatures is essential to optimise and tailor the performance of these materials; yet experimental thermodynamic and structural data for refractory oxides above 2000°C are mostly absent. The following techniques that can be applied to fill this gap are discussed: (i) commercial ultra-high-temperature differential thermal analysis for investigation of phase transformations and melting in inert environments to 2500°C, (ii) a combination of laser heating with a splittable nozzle aerodynamic levitator for splat quenching and drop calorimetry from temperatures limited only by sample evaporation, (iii) synchrotron X-ray and neutron diffraction on laser-heated aerodynamically levitated oxide samples for in situ observation of phase transformations in variable atmospheres, refinement of high-temperature structures and thermal expansion. Recent experimental findings include anomalous thermal expansion of the defect fluorite phase of YSZ, thermodynamics of pyrochlore–fluorite transformation from high-temperature structure refinements, and measurement of thermal expansion to the melting temperatures and fusion enthalpies of Zr, Hf, La, Yb and Lu oxides. These methods provide temperatures, enthalpies and volume change for phase transformations above 2000°C, which are required for thermodynamic assessments and calculation of phase diagrams of multicomponent systems.
Since the last past years, the Nuclear Measurement Laboratory of CEA Cadarache, France, together with Partners from European and National projects, has been studying the application of fast neutron interrogation with the Associated Particle Technique for material identification in different areas of homeland and maritime security, and for the characterisation of the materials constituting radioactive waste. Fast 14 MeV neutrons are produced from the H-3(H-2,n)alpha fusion reaction in a sealed tube neutron generator embedding an alpha detector. The alpha particle is used to tag neutron direction and emission time, thus allowing the electronic selection of neutron-induced gamma spectra in the voxels of interest. Gamma rays emitted by tagged neutron interactions on the present nuclei (C, O, N, Fe, Al, Si, Cl, etc.) are recorded with spectroscopic detectors and analysed to determine elemental proportions, thus allowing material identification. Investigations have been conducted for the detection of explosives, illicit drugs and contraband materials in cargo containers, for the inspection of objects lying on the sea floor suspected to contain explosives like mines, bombs, torpedoes, etc., for the recognition of an improvised chemical device, and for material identification in radioactive waste packages. Recently the detection of special nuclear materials is being investigated using time correlation analysis between induced fission particles, instead of gamma-ray spectroscopy. The paper presents an overview of these studies and last results. (authors)
We report circular dichroism measurements on the helix-coil transition of poly(L-glutamic acid) in solution with polyethylene glycol (PEG) as a crowding agent. The PEG solutions have been characterized by small angle neutron scattering and are well described by the picture of a network of mesh size {xi}, usual for semi-dilute chains in good solvent. We show that the increase of PEG concentration stabilizes the helices and increases the transition temperature. But more unexpectedly, we also notice that the increase of concentration of crowding agent reduces the mean helix extent at the transition, or in other words reduces its cooperativity. This result cannot be taken into account for by an entropic stabilization mechanism. Comparing the mean length of helices at the transition and the mesh size of the PEG network, our results strongly suggest two regimes: helices shorter or longer than the mesh size.
The BC8 silicon allotrope has a lattice thermal conductivity 1–2 orders of magnitude lower than that of diamond-cubic silicon. In the current work, the phonon density of states, phonon dispersion, and lattice thermal conductivity are investigated by inelastic neutron scattering measurements and first-principles calculations. Flat phonon bands are found to play a critical role in the reduction of lattice thermal conductivity in BC8–Si. Such bands in the low-energy range enhance the phonon scattering between acoustic and low-energy optical phonons, while bands in the intermediate-energy range act as a scattering bridge between the high- and low-energy optical phonons. Further, they significantly enlarge the phonon-phonon scattering phase space and reduces the lattice thermal conductivity in this novel silicon allotrope. This work provides insights into the significant reduction of the lattice thermal conductivity in BC8–Si, thus expanding the understanding of novel silicon allotropes and their development for electronic devices.
The effects of neutron irradiation to a dose of 3 dpa at 600 C and creep for 38,555 h at 800 C on the microstructure of a commercial MA957 alloy were investigated by atom probe tomography. The size, number density and composition of the 2-nm-diameter Ti-, Y-, O-enriched nanoclusters were similar in the unirradiated, crept and neutron irradiated conditions indicating that the microstructure of this nanostructured ferritic alloy has remarkable tolerance to radiation damage.
Here, a reduced activation ferritic/martensitic steel, Eurofer97, was neutron irradiated in the vicinity of 300 °C in the High Flux Isotope Reactor (HFIR) up to 72 dpa. Advanced analytical scanning transmission electron microscopy and conventional transmission electron microscopy were applied to investigate the radiation-induced segregation and phase instability behavior after neutron irradiation. Amorphization was observed in M 23 C 6 carbides. Cr-rich clusters were seen within the matrix, near the lath boundaries and close to the M 23 C 6 carbides. Cr enrichment and Fe depletion were detected at both prior austenite grain boundaries and lath boundaries, despite different segregation magnitude. In addition, the enrichment of Ni, the depletion of V, and tiny cavities (presumably helium bubbles) are also found at lath boundaries. This work interrogates the evolution of microstructures after neutron irradiation, which provides detailed understanding on the microstructural aspects controlling the mechanical integrity of Eurofer97 under high-dose neutron damage.
An array of lithium indium diselenide (LISe) scintillators were investigated for application in neutron imaging. The sensors, varying in thickness and surface roughness, were tested using both reflective and anti-reflective mounting to the aluminum window. The spatial resolution of each LISe scintillator was calculated using the knife-edge test and a modulation transfer function analysis. It was found that the anti-reflective backing yielded a significantly higher spatial resolution over the reflective backing, and in most cases far exceeded the spatial resolution of a 50 μm-thick ZnS(Cu): 6 LiF scintillation screen. Further, an apparent relationship between the observed increase in spatial resolution when using an anti-reflective backing and the quotient of the surface roughness to the thickness of the LISe scintillator was observed. Lastly, the LISe scintillator array was used in neutron computational tomography to investigate the features of halyomorpha halys.
The phosphorylation of specific residues in a flexible disordered activation loop yields precise control of signal transduction. One paradigm is the phosphorylation of S339/S340 in the intrinsically disordered tail of the multi-domain scaffolding protein NHERF1, which affects the intracellular localization and trafficking of NHERF1 assembled signaling complexes. Using neutron spin echo spectroscopy (NSE), we show salt-concentration-dependent excitation of nanoscale motion at the tip of the C-terminal tail in the phosphomimic S339D/S340D mutant. The “tip of the whip” that is unleashed is near the S339/S340 phosphorylation site and flanks the hydrophobic Ezrin-binding motif. The kinetic association rate constant of the binding of the S339D/S340D mutant to the FERM domain of Ezrin is sensitive to buffer salt concentration, correlating with the excited nanoscale dynamics. The results suggest that electrostatics modulates the activation of nanoscale dynamics of an intrinsically disordered protein, controlling the binding kinetics of signaling partners. Furthermore NSE can pinpoint the nanoscale dynamics changes in a highly specific manner.
We present and discuss the operational principle of a new fast-neutron detector concept suitable for either energy-selective imaging or for imaging spectroscopy. The detector is comprised of a series of energy-selective stacks of converter foils immersed in a noble-gas based mixture, coupled to a position-sensitive charge readout. Each foil in the various stacks is made of two layers of different thicknesses, fastened together: a hydrogen-rich (plastic) layer for neutron-to-proton conversion, and a hydrogen-free coating to selectively stop/absorb the recoil protons below a certain energy cut-off. The neutron-induced recoil protons, that escape the converter foils, release ionization electrons in the gas gaps between consecutive foils. The electrons are then drifted towards and localized by a position-sensitive charge amplification and readout stage. Comparison of the images detected by stacks with different energy cut-offs allows energy-selective imaging. Neutron energy spectrometry is realized by analyzing the responses of a sufficient large number of stacks of different energy response and unfolding techniques. In this paper, we present the results of computer simulation studies and discuss the expected performance of the new detector concept. Potential applications in various fields are also briefly discussed, in particularly, the application of energy-selective fast-neutron imaging for nuclear safeguards application, with the aim of determining the plutonium content in Mixed Oxide (MOX) fuels.
Kirkpatrick-Baez (KB) neutron supermirrors can efficiently focus polychromatic neutron beams to micrometre dimensions. The ultimate size is determined mainly by the perfection of the mirrors and by the size of the beam needed to have sufficient experimental signal. Nested or Montel KB mirrors can collect ~2.6 times more beam than standard sequential KB optics, but require good figure perfection at the edge of one mirror. This paper describes the characterization of the figure errors over the important reflective portions of the two mirrors needed for a Montel focusing pair. The measurements are placed in context with theoretical predictions and are used to predict mirror focusing performance. Strategies to improve on the focusing of this class of optics are suggested and early results from these mirrors installed on the Spallation Neutrons at Pressure (SNAP) Beamline 3 at the Spallation Neutron Source (SNS) at Oak Ridge are presented.
As an mRNA-based vaccine, the Pfizer-BioNTech COVID-19 vaccine has stringent cold storage requirements to preserve functionality of the mRNA active ingredient. To this end, lipid components of the vaccine formulation play an important role in stabilizing and protecting the mRNA molecule for long-term storage. The purpose of the current study was to measure molecular-level dynamics as a function of temperature in the Pfizer-BioNTech COVID-19 vaccine to gain microscopic insight into its thermal stability. Materials and Methods: We used quasielastic and inelastic neutron scattering to probe (1) the vaccine extracted from the manufacturer-supplied vials and (2) unperturbed vaccine in the original manufacturer-supplied vials. The latter measurement was possible due to the high penetrative power of neutrons. Upon warming from the low-temperature frozen state, the vaccine in its original form exhibits two-step melting, indicative of a two-phase morphology. Once the melting is completed (above 0 °C), vaccine re-freezing cannot restore its original two-phase state. This observation is corroborated by the changes in the molecular vibrational spectra. The molecular-level mobility measured in the resulting single-phase state of the re-frozen vaccine greatly exceeds the mobility measured in the original vaccine. Even a brief melting (above 0 °C) leads to an irreversible alteration of the two-phase morphology of the original vaccine formulation. Re-freezing of the vaccine results in a one-phase morphology with much increased molecular-level mobility compared to that in the original vaccine, suggesting irreversible deterioration of the vaccine’s in-storage stability. Neutron scattering can be used to distinguish between the vibrational spectra characteristic of the original and deteriorated vaccines contained in the unperturbed original manufacturer-supplied vials.
Radiation induced structural and energetic changes have been widely studied in crystalline materials, but studied to a much lesser extent in amorphous solids. Using a combination of neutron pair distribution function (PDF) analysis and high temperature oxide melt solution calorimetry, we obtained critical insights into the structural and energetic evolution in a swift heavy ion irradiated amorphous SiOC polymer-derived ceramic. The radiation modified SiOC structure becomes energetically less stable by 24.0±1.6 kJ/mol compared to the unirradiated structure. This destabilization is related to decreased connectivity of the Si-O-C network and destruction of free carbon. In comparison with unirradiated SiOC, the irradiated structure is more likely to become phase separated during subsequent thermal annealing. Here, our study has important implications for evaluating amorphous SiOC ceramic as a possible radiation resistant structure for nuclear applications.
Silicon carbide (SiC) is a widely preferred material within many industries due to its favorable properties, most notably its low electrical resistivity at high temperatures, excellent thermal conductivity, and sturdy mechanical properties. Doping, particularly n-type doping, is shown to extremely reduce electrical resistivity, but due to structural changes within the lattice caused by interaction with thermal neutrons, it is possible that other attributes of SiC may also be affected. In addition to review of past literature and data, four-point probe testing, scanning electron microscopy, nanoindentation, strength tests, differential scanning calorimetry and laser flash analysis were used to investigate the effects of n-doping 3C ß-phase SiC. According to temperature dependent measurements, electric resistivity and thermal conductivity both declined as dopant levels increases. Dopant levels are shown to have a significant effect on the mechanical performance of SiC, with the highest dopant levels (4 x 1018 cm-3) providing a 40% decrease in elastic modulus from 420 GPa to 258 GPa and a 30% decrease in hardness from 40 GPa to 27.7 GPa. These values are still above average and doped SiC may prove valuable for nuclear applications.
Topological insulator–magnetic insulator (TI–MI) heterostructures hold significant promise in the field of spintronics, offering the potential for manipulating magnetization through topological surface state–enabled spin-orbit torque. However, many TI–MI interfaces are plagued by issues such as contamination within the magnetic insulator layer and the presence of a low-density transitional region of the topological insulator. These interfacial challenges often obscure the intrinsic behavior of the TI–MI system. In this study, we addressed these challenges by depositing sputtered Bi 2 Te 3 on liquid phase epitaxy grown Y 3 Fe 5 O 12 /Gd 3 Ga 5 O 12 . The liquid phase epitaxy grown Y 3 Fe 5 O 12 has been previously shown to have exceptional interface quality, without an extended transient layer derived from interdiffusion processes of the substrate or impurity ions, thereby eliminating rare-earth impurity-related losses in the MI at low temperatures. At the TI–MI interface, high-resolution depth-sensitive polarized neutron reflectometry confirmed the absence of a low-density transitional growth region of the TI. By overcoming these undesirable interfacial effects, we isolate and probe the intrinsic low-temperature magnetization dynamics and transport properties of the TI–MI interface. In conclusion, our findings revealed strong spin pumping at low temperatures, accompanied by an additional in-plane anisotropy. The enhanced spin pumping at low temperatures is correlated with the observed suppression of bulk conduction and the weak antilocalization in the TI film, highlighting the interplay between the transport and spin pumping behavior in the TI–MI system.
Based on the M5{sup R}* alloy metallurgy, the Q12{sup TM} alloy (Zr-1Nb-0.5Sn-0.1Fe) was developed by AREVA NP for structural components, with ultra-low tin addition and slightly increased iron content. The behavior of this alloy was tested under irradiation in a pressurized water reactor (PWR) and has shown improvement in irradiation creep strength and similar free growth compared with M5. This paper provides results on dimensional stability and details the microstructural evolution of the Q12 alloy under neutron irradiation in PWRs. The Q12 microstructural evolution under irradiation was studied for fast neutron fluences up to 13 X 10{sup 25} n/m{sup 2} (E>1 MeV) with analytical transmission electron microscopy observations. We focused on radiation-enhanced needle-like particles, Laves phases, and the linear density of -component loops. These results are compared with other quaternary zirconium-niobium-tin-iron alloys and with M5. All these results allow a general discussion about microstructural evolution and behavior under irradiation of quaternary-type alloys compared to M5 alloy. This study, in agreement with previous works on Zr-1Nb and quaternary alloys, seems to show that increasing the iron content with the presence of niobium and tin will decrease the -component loop linear density and delay the growth breakaway. (authors)
The Goal of the Imaging X-Ray Polarimetry Explorer (IXPE) Mi SMEX), is to expand understanding of high-energy astrophysical processes and sources, in support of NASA’s first science objective in Astrophysics: “Discover how the universe works.” IXPE, an international collaboration, will conduct X-ray imaging polarimetry for multiple categories of cosmic X-ray sources such as neutron stars, stellar-mass black holes, supernova remnants and active galactic nuclei. The Observatory uses a single science operational mode capturing the X-ray data from the targets. The IXPE Observatory consists of spacecraft and payload modules built up in parallel to form the Observatory during system integration and test. The payload includes three X-ray telescopes each consisting of a polarization-sensitive, gas pixel X-ray detector, paired with its corresponding grazing incidence mirror module assembly (MMA). A deployable boom provides the correct separation (focal length) between the detector units (DU) and MMAs. These payload elements are supported by the IXPE spacecraft which is derived from the BCP-small spacecraft architecture. This paper summarizes the IXPE mission science objectives, updates the Observatory implementation concept including the payload and spacecraft ts and summarizes the mission status since last year’s conference.
Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1-inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the CVs. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of special nuclear material (SNM) in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of {le}100-g {sup 239}Pu equivalent in a vessel for safeguards termination. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements.