Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Correlation of Scan and Sample Measurements Using Appropriate Sample Size

At a former nuclear fuel cycle facility, radiological site characterization performed in the 1990's relied on surface soil samples collected and analyzed on a systematic sampling grid, supplemented by 100% scans of the property to identify soil exceeding decommissioning criteria. Biased sampling was performed as indicated by these measurements to provide more precise delineation of material exceeding the decommissioning criteria of 0.37 Bq/g total thorium (the Criteria). All material exceeding the Criteria was to be excavated for shipment to a licensed disposal facility. The site characterization plan called for collection of {approx}100-gram soil samples on a ten-meter grid, at which locations the gamma exposure rate was recorded at a height of 1 meter above grade. While 25-gram aliquots of the soil samples were being counted by gamma spectroscopy, the area was surveyed with a 7.6 cm X 1.27 cm (3'' X 1/2'') NaI gamma detector positioned 1 meter above grade. Count rates were recorded every two seconds while the detector moved at less than one meter per second, resulting in readings at nearly one-meter intervals. Scan records were reviewed; locations exceeding a pre-determined threshold were sampled to identify material exceeding the decommissioning criteria not identified in the systematic sampling effort. Location data (X, Y, and Z) were imported into an interactive database with {mu}R/hr measurements, sample count results, and scan readings. Data was graphically portrayed by color-coding data and superimposing the measurements on maps. Data reviewers could thereby review all types of data superimposed on each other to minimize review time, and to easily identify areas requiring further investigation. Data reviewers observed that in one area covering several acres, scan and sample measurements did not correlate. In some locations, scans indicated near-background gamma count rates while soil samples yielded several times the decommissioning criteria. At other locations, gamma count rates were elevated, but samples yielded background concentrations of thorium. Gamma scans tended to correlate with gamma exposure rate measurements. The lack of correlation between scan and sample data threatened to invalidate the characterization methodology, because neither method demonstrated reliability in identifying material which required excavation, shipment, and disposal. The NRC-approved site decommissioning plan required the excavation of any material that exceeded the Criteria based on either measurement. It was necessary to resolve the differences between the various types of measurements. Health Physics technicians selected 27 locations where the relationship between scan measurements and sample counts was highly variable. To determine if 'shine' was creating this data-correlation problem, they returned to those 27 locations to collect gamma count rates with a lead shielded NaI detector. Figure 2 shows that the shielded and unshielded count rates correlated fairly well for those locations. However, the technicians also noted the presence of 'tar balls' in this area. These small chunks of tarry material typically varied in size from 2 - 10 mm in diameters. Thorium-contaminated tars had apparently been disked into the soil to biodegrade the tar. The technicians evaluated the samples, and determined that the samples yielding higher activity contained more tar balls, and the samples yielding near background levels had fewer or none. The tar was collected for analysis, and its thorium activity varied from 2 - 3 Bq/g (60 - 90 pCi/g) total thorium. Since the sample mass was small, these small tar balls greatly impacted the sample activity. Technicians determined that the maximum particle size was less than 20 mm in diameter. Based on this maximum 'particle size', over one kilogram of sample would be required to minimize the impact of the tar balls on sample results. They returned to the same 27 locations and collected soil samples containing at least one kilogram of material. The samples were thoroughly ground and blended. Aliquots were then counted using 25-gram sample bottles, as in the initial characterization effort. Figure 3 shows the significantly improved correlation between counts per minute (using the original unshielded detector measurements) and soil sample results. Licensed material is not always homogeneously distributed in environmental media. When licensed material becomes concentrated in a particular material type, such as fine-grained soil or (as was the case at this site) hydrocarbon contaminated material, large blended samples may be required to provide adequate correlation between in-situ measurements, such as gamma scans, and sample activity. Sample size should be sufficiently large to yield a sample truly representative of the soil being surveyed, and should be thoroughly blended to ensure homogeneous distribution of the licensed material in the aliquot being analyzed. If blending is not practical, the entire sample should be counted in aliquots, and the average activity should be used as the true volumetric activity of the material being surveyed.

54 ENVIRONMENTAL SCIENCES↗

The locational value of distributed energy resources: A parcel-level evaluation of solar and wind potential in New York state

We report distributed energy resources (DERs) are poised to play a significant role in evolving power systems because of their flexibility to be sited in areas of high value to the grid. Traditional DER compensation frameworks, specifically net energy metering (NEM), inadequately communicate differences in the locational and temporal value of DER generation to the grid. As a transition from NEM, New York State's (NYS's) Value of Distributed Energy Resources (VDER) framework provides a methodology for calculating different value components that DERs offer the grid. To study the impacts of VDER frameworks on DER deployment, we developed a model to assess the value of distributed solar and wind systems configured as either a behind-the-meter system or a front-of-the-meter system for each parcel of land in NYS. Using parcel-level granularity, we can closely evaluate DER locational value and siting availability, particularly in urban and suburban settings. Our analysis finds while most DER generators would be modestly compensated for deferred transmission and distribution infrastructure upgrades (~0.01 $\$$/kWh for solar PV), a subset of projects receive significant value from this component (0.035 to 0.089 $\$$/kWh for top 5% of parcels for solar PV). Finally, our analysis finds VDER provides less overall compensation than NEM to the average DER generator, however, it increases access to compensation for front-of-the-meter DERs - a large and emerging market.

14 SOLAR ENERGY↗

Compensation for Distributed Solar. A Survey of Options to Preserve Stakeholder Value

Compensation mechanisms for electricity generation systems installed behind the meter are under scrutiny in several jurisdictions in the United States. Legislators in 29 states introduced bills to amend net metering provisions in 2014, and in 33 states in the 2015 legislative session as of August 20, 2015. Some utilities have also sought to increase the revenue they receive from net-metered customers through rate redesign. The circumstances that have triggered the recent push for change include a growing percentage of net-metered customers, potential effects of distributed generation on cost allocation, decreasing photovoltaic (PV) system costs, the challenges of integrating high levels of solar generation in the distribution network, and increasing pressure on utility business models. This report presents a survey of options to charge and compensate PV customers, as well as options that may preserve utility revenues in scenarios with increased DG. These options could be used as building blocks to create a distributed generation (DG) compensation policy that may preserve the value of the different stakeholders and balance their interests.

14 SOLAR ENERGY↗

Energy End-Use Patterns in Full-Service Hotels: A Case Study

The U.S. Department of Energy (DOE) recently initiated a program -- Commercial Building Partnerships (CBP) -- to work with private-sector companies in the design of highly-efficient retrofit and new construction projects. Pacific Northwest National Laboratory (PNNL) is conducting a project with a major hotel company to retrofit a full-service, large hotel with the goal of reducing energy consumption by at least 30%. The first step of the project was an intensive metering and monitoring effort aimed at understanding energy end use patterns in the hotel. About 10% of the guest rooms (32), as well as circuits for most of the end uses in public spaces (lighting, elevators, air handlers and other HVAC system components, and various equipment), were equipped with meters. Data are being collected at 1- or 5-minute intervals and downloaded on a monthly basis for analysis. This paper presents results from the first four months of the monitoring effort, which revealed energy end-use consumption patterns, variability of guest room energy use, daily load curves, monthly variations, and other aspects of hotel energy use. Metered end-use data for hotels at this level of detail are not available from any currently-available public sources. This study presents unique information and insight into energy end-use patterns in the lodging sector of commercial buildings and can also serve as a case study of a complex sub-metering project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of gamma-ray spectral analysis methods for thick-walled UF 6 cylinders

Three data analysis methods were compared for gamma ray spectra collected by planar and coaxial high-purity germanium detectors (HPGe) on thick-walled uranium hexafluoride cylinders. The cylinder contents range from natural to low-enriched uranium (4.95% 235 U). Each spectrum was analyzed with the traditional 185.7 keV enrichment meter method, a 185.7/1001 keV ratio method, and the Fixed Energy Response Function Analysis with Multiple Efficiency (FRAM) software that utilizes low- and high-energy gamma rays and X-rays. When results for all cylinders were compared, the enrichment meter method and the 185.7/1001 keV peak ratio method consistently provided the most accurate data for all detector types. The error on the enrichment calculations analyzed with FRAM did not meet the international target value whereas those calculated with the enrichment meter and ratio method did. Enrichments calculated by FRAM were found to skew to higher values on natural uranium and to lower values on low-enriched uranium. FRAM calculated the least-precise enrichments; replicate analyses of single cylinders resulted in 235 U values that varied by as much as 19%. FRAM does have the significant advantages in that it does not require the use of calibration cylinders, infinite thickness criteria are not necessary, and it can be applied to any HPGe detector. Finally, if calibration cylinders are available, the enrichment meter and 185.7/1001 peak ratio are the recommended methods as they are the most accurate and precise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Ground Motion Characteristics on the Seismic Response of a Monumental Concrete Arch Bridge

Railway network in Turkey dates back to more than a hundred years ago and according to official records, there are approximately 18,000 railway bridges with spans varying between 50 cm up to 150 meters. One of them is a monumental concrete arch bridge with a total length of 210 meters having three major spans of 30 meters and a height of 65 meters, located in an earthquake-prone region in southern part of the country. Three-dimensional finite element model of the bridge was generated using a commercially available general finite element analysis software and based on the outcomes of a series of in-depth acceleration measurements that were conducted on-site, the model was refined. Types of ground motion records were used to investigate the seismic response and vulnerability of this massive structure in order to provide information regarding (i) damage-susceptible regions of the structure for monitoring purposes, and, (ii) seismic loads to be taken into account during evaluation and possible strengthening phases for this type of structures.

58 GEOSCIENCES↗

The Study of Electromagnetic Field Response Using Very Low Frequency Methods in Geothermal Area, Sabang

Electromagnetic field measurements have been performed using the method of Very Low Frequency tilt angle pattern in Jaboi, Sabang. A site survey was conducted and carried out to identify the anomalies of location, depth and geometry of hydrothermal based on tilt angle measurement and ellipse. Objective of this study is to see the response of the magnetic and electric field in relation to location, depth and hydrothermal geometry. The devices of T-VLF-R IRIS was used in this study, while the (NWC) station was selected as main station and (JJF4) station was selected as comparison station. The electromagnetic field survey was recorded for a line spanned as long as 900 meters at the interval of 10 meter depth. The results of this study show the greatest anomaly occurred at line interval between 400-600 meters with a depth of 10-140 meters. Anomaly pattern of each depth shows that the propagation pattern of hydrothermal is in the form of vertical pipe flow.

58 GEOSCIENCES↗

The effects of sampling location and turbulence on discharge estimates in short converging turbine intakes

Standards provide recommendations for best practices when installing current meters to measure fluid flow in closed conduits. A central guideline requires the velocity distribution to be regular and the flow steady. Because of the nature of the short converging intakes typical of low-head hydroturbines, these assumptions may be invalid if current meters are intended to be used to estimate discharge. Usual concerns are (1) the effects of the number of devices, (2) the sampling location and (3) the high turbulence caused by blockage from submersible traveling screens usually deployed for safe downstream fish passage. These three effects were examined in the present study by using 3D simulated flow fields in both steady-state and transient modes. In the process of describing an application at an existing hydroturbine intake at Ice Harbor Dam, the present work outlined the methods involved, which combined computational fluid dynamics, laboratory measurements in physical models of the hydroturbine, and current meter performance evaluations in experimental settings. The main conclusions in this specific application were that a steady-state flow field sufficed to determine the adequate number of meters and their location, and that both the transverse velocity and turbulence intensity had a small impact on estimate errors. However, while it may not be possible to extrapolate these findings to other field conditions and measuring devices, the study laid out a path to conduct similar assessments in other applications.

computational fluid dynamics (CFD)↗

McGee Mountain Shallow (2m) Temperature Survey, Humboldt County, Nevada 2009

This shapefile contains location and attribute data for a shallow (2 meter) temperature survey conducted by Geothermal Technical Partners, Inc. during late 2008 and early 2009. Temperatures at 2m depth were measured at 192 separate points as outlined by Coolbaugh et al., 2007. The purpose of the survey was to try and detect a shallow thermal anomaly associated with the McGee Mountain geothermal area as discovered by Phillips Petroleum and Earth Power Resources in the late 1970’s. Drilling identified ~120oC temperatures at ~100m depth. This 2-meter survey delineated what was interpreted as a steam-heated fault zone centered along a range front fault in the vicinity of the drilled holes and fumaroles. Coolbaugh, M.F., Sladek, C., Faulds, J.E., Zehner, R.E., and Oppliger, G.L., 2007, Use of rapid temperature measurements at a 2-meter depth to augment deeper temperature gradient drilling: Proceedings, 32nd Workshop on Geothermal Reservoir Engineering, Stanford University, Stanford, CA, Jan. 22-24, 2007, p. 109-116. Zehner, R., Tullar, K., and Rutledge, E., 2012, Effectiveness of 2-Meter and geoprobe shallow temperature surveys in early stage geothermal exploration: Geothermal Resources Council Transactions, v. 36, in press.

15 GEOTHERMAL ENERGY↗

Spinning Reserve From Hotel Load Response: Initial Progress

This project was motivated by the fundamental match between hotel space conditioning load response capability and power system contingency response needs. As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. At ORNL s suggestion, Digital Solutions Inc. adapted its hotel air conditioning control technology to supply power system spinning reserve. This energy saving technology is primarily designed to provide the hotel operator with the ability to control individual room temperature set-points based upon occupancy (25% to 50% energy savings based on an earlier study [Kirby and Ally, 2002]). DSI added instantaneous local load shedding capability in response to power system frequency and centrally dispatched load shedding capability in response to power system operator command. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host the spinning reserve test. The Tennessee Valley Authority supplied real-time metering equipment in the form of an internet connected Dranetz-BMI power quality meter and monitoring expertise to record total hotel load during both normal operations and test results. The Sevier County Electric System installed the metering. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. These results are prior to implementing control over the common area air conditioning loads. Testing was also not at times of highest system or hotel loading. Full response occurred in 12 to 60 seconds from when the system operator s command to shed load was issued. The load drop was very rapid, essentially as fast as the 2 second metering could detect, with all units responding essentially simultaneously. Load restoration was ramped back in over several minutes. The restoration ramp can be adjusted to the power system needs. Frequency response testing was not completed. Initial testing showed that the units respond very quickly. Problems with local power quality generated false low frequency signals which required testing to be stopped. This should not be a problem in actual operation since the frequency trip points will be staggered to generate a droop curve which mimics generator governor response. The actual trip frequencies will also be low enough to avoid power quality problems. The actual trip frequencies are too low to generate test events with sufficient regularity to complete testing in a reasonable amount of time. Frequency response testing will resume once the local power quality problem is fully understood and reasonable test frequency settings can be determined. Overall the preliminary testing was extremely successful. The hotel response capability matches the power system reliability need, being faster than generation response and inherently available when the power system is under the most stress (times of high system and hotel load). Periodic testing is scheduled throughout the winter and spring to characterize hotel response capability under a full range of conditions. More extensive testing will resume when summer outdoor temperatures are again high enough to fully test hotel response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wind Generation on Winnebago Tribal Lands

The Winnebago Wind Energy Study evaluated facility-scale, community-scale and commercial-scale wind development on Winnebago Tribal lands in northeastern Nebraska. The Winnebago Tribe of Nebraska has been pursuing wind development in various forms for nearly ten years. Wind monitoring utilizing loaned met towers from NREL took place during two different periods. From April 2001 to April 2002, a 20-meter met tower monitored wind data at the WinnaVegas Casino on the far eastern edge of the Winnebago reservation in Iowa. In late 2006, a 50-meter tower was installed, and subsequently monitored wind data at the WinnaVegas site from late 2006 through late 2008. Significant challenges with the NREL wind monitoring equipment limited the availability of valid data, but based on the available data, average wind speeds between 13.6 – 14.3 miles were indicated, reflecting a 2+/3- wind class. Based on the anticipated cost of energy produced by a WinnaVegas wind turbine, and the utility policies and rates in place at this time, a WinnaVegas wind project did not appear to make economic sense. However, if substantial grant funding were available for energy equipment at the casino site, and if either Woodbury REC backup rates were lower, or NIPCO was willing to pay more for wind power, a WinnaVegas wind project could be feasible. With funding remaining in the DOE-funded project budget,a number of other possible wind project locations on the Winnebago reservation were considered. in early 2009, a NPPD-owned met tower was installed at a site identified in the study pursuant to a verbal agreement with NPPD which provided for power from any ultimately developed project on the Western Winnebago site to be sold to NPPD. Results from the first seven months of wind monitoring at the Western Winnebago site were as expected at just over 7 meters per second at 50-meter tower height, reflecting Class 4 wind speeds, adequate for commercial development. If wind data collected in the remaining months of the twelve-month collection period is consistent with that collected in the first seven months, the Western Winnebago site may present an interesting opportunity for Winnebago. Given the distance to nearby substations, and high cost of interconnection at higher voltage transmission lines, Winnebago would likely need to be part of a larger project in order to reduce power costs to more attractive levels. Another alternative would be to pursue grant funding for a portion of development or equipment costs, which would also help reduce the cost of power produced. The NREL tower from the WinnaVegas site was taken down in late 2008, re-instrumented and installation attempted on the Thunderway site south of the Winnebago community. Based on projected wind speeds, current equipment costs, and the project’s proximity to substations for possible interconnection, a Thunderway community-scale wind project could also be feasible.

17 WIND ENERGY↗

Profiling Real-Time Electricity Consumption Data for Process Monitoring and Control

Today, smart meters serve as key assets to utilities and their customers because they are capable of recording and communicating real-time energy usage data; thus, enabling better understanding of energy usage patterns. Other potential benefits of smart meters data include the ability to improve customer experience, grid reliability, outage management, and operational efficiency. Despite these tangible benefits, many utilities are inundated by data and remain uncertain about how to extract additional value from these deployed assets outside of billing operations. One way to overcome this challenge is the development of new metrics for classifying utility customers. Traditionally, utilities classified their customers based on their business nature (residential, commercial, and industrial) and/or their total annual consumption. While this classification is useful for some operational functions, it is too limited for designing effective monitoring and control strategies. In this paper, a data mining methodology is proposed for clustering and profiling smart meters data in order to form unique classes of customers exhibiting similar usage patterns. The developed clusters could help utilities in identifying opportunities for achieving some of the benefits of smart meters data.

consumer engagement↗

Impact of system parameters and geospatial variables on the reliability of residential systems with PV and energy storage

A reliable power supply is the foundation of modern society, enabling technologies used to function within a society. Residential systems are places where the end users directly consume power, enabling technologies to sustain life. With the emergence of behind-the-meter resources, the end-users have some control over power supply reliability. The intermittency and variability of these resources impact residential system reliability. In this work, we study the reliability performance of a grid-supplemented residential system with behind-the-meter Distributed Energy Resources(DER) subject to various system parameters and geospatial variables. We propose a multistate reliability model for the behind-the-meter microinverter-based Photo Voltaic (PV) system and integrated inverter-based energy storage (ES) system. A sequential Monte Carlo method is then presented to evaluate the reliability indices for the residential system with behind-the-meter DERs as the main supply and the grid as the backup. The sequential Monte Carlo method is used to analyze the reliability performance of the residential model at the top 100 populous counties of the United States, where actual load and solar irradiance data at the counties is used. In the analysis, the sensitivity of indices to system parameters such as DER size and the sensitivity of the indices to climate zone and gross horizontal irradiation (GHI), which affects the load conditions and the PV output of the residential system, is performed. The analysis results show that the system parameters and the geospatial variables significantly impact the residential system’s reliability. The insights from this analysis will be of immense value to the distribution system planners to provide zone-specific guidelines for DER system sizing and toward the evolution of utility business models. Finally, the methodology developed can be used to extend the analysis to other locations.

14 SOLAR ENERGY↗

The impact of capillary heterogeneity on CO 2 flow and trapping across scales

Capillary heterogeneity has been identified over the last decade as a key control on subsurface CO 2 flow behavior during geological CO 2 sequestration. These heterogeneities can be formed in all sedimentary rocks, ranging from slight variations in the sand grain sizes to extensive sequences of interbedded sands, shales, and limestones. Capillary heterogeneity has been largely, although not entirely, overlooked in subsurface flow modeling because it is assumed to only directly influence fluid redistribution over scales of centimeters to meters. However, even small-scale fluid movements can result in dramatic impacts on the mobility and trapping of the CO 2 over kilometers. Therefore, neglecting capillary heterogeneity at multiple scales could potentially lead to errors in modeling and predicting field-scale plume migration. In this review paper, we aim to provide a consistent overview to (1) establish that capillary heterogeneity can have a major impact on CO 2 plume migration, (2) establish the respective length scales at which capillary heterogeneity matters, and (3) provide guidance for numerical modeling. This review covers pertinent literature and extracts key observations from the core to the field scales. Experimental studies have shown that millimeter-decimeter scale capillary heterogeneity can cause the so-called capillary heterogeneity trapping in addition to pore-scale residual trapping. Even at such a small scale, capillary heterogeneity can already lead to complex upscaled constitutive relationships, such as flow-rate dependent and anisotropic relative permeability, which affects field-scale CO 2 migration even when field-scale heterogeneities are present. Under gravity-dominated flow regimes, centimeter-meter scale capillary heterogeneity can entrap a significant amount of CO 2 at field scale, not just after imbibition but also during drainage. In certain cases, the presence of capillary heterogeneity can even completely stop the vertical movement of the CO 2 plume, hence greatly reducing leakage risks. At meter-kilometer scale, the influence of capillary heterogeneity is more pronounced and can hinder or redirect CO 2 migration in both lateral and vertical directions. The impact of capillary heterogeneity across multiple spatial scales poses a great challenge in modeling CO 2 migration at field scale, because it is practically impossible to build a field-scale earth model with grid blocks at millimeter scale. We recommend a hierarchical modeling approach to address this challenge. At field scale, earth models are built to capture geological features and heterogeneities in high but still practical grid resolutions. For each facies or rock type of the field-scale model, high- resolution meter-scale “conceptual” models are built with millimeter-scale grid blocks to capture representative fine-scale bedding geometries and heterogeneities in various environments of deposition, bridging the gap from subcore scale to the size of a field-scale simulation grid block. Upscaling is then used to preserve the smaller-scale flow dynamics of various rock types in field-scale simulations. Here, future work is needed to (1) refine, improve, and validate the hierarchical modeling approach; (2) build libraries of fine-scale bedding models for facies in various environments of deposition; (3) quantify multiscale capillary heterogeneity effects under subsurface uncertainties; (4) gain learning from different storage formations; and (5) establish best practices that balance accuracy and computational speed.

Capillary heterogeneity↗

Precision Polarimetry of Solid HD Photonuclear Targets at LEGS

We have constructed and operated a NMR polarimeter for high-accuracy measurements of hydrogen and deuterium polarization in a frozen-spin solid HD photonuclear physics target. The heart of this polarimeter is a pair of crossed (orthogonal) RF coils that form a transformer that responds only to precessing spins in the sample. We have performed a complete electronic circuit analysis of this crossed coil polarimeter (CC-Meter), and have determined the optimum conditions for its operation. From this analysis, which is confirmed by NMR measurements on hydrogen and deuterium in solid HD, we conclude that the CC-meter can be operated to give a very high signal-to-noise ratio (SNR) for thermal equilibrium polarization while also producing a highly linear response for fully polarized targets. In general, we find that a well-designed and properly constructed CC-Meter can provide a larger SNR at similar nonlinearity, compared to the more commonly used Q-meter. We have used this polarimeter to produce H polarization measurements for a new, high precision determination of the GDH integral for the proton.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, construction, and testing of no-insulation small subscale solenoids for compact tokamaks

Fusion energy systems studies (FESS) for next-step devices based on the most promising magnetic configurations indicate that high magnetic fields and high current density for magnet coil systems may reduce device size and lower the cost. High current density and radiation resistant fusion magnets are particularly beneficial for low cost, low aspect ratio compact reactor designs such as Fusion Nuclear Science Facility (FNSF), Fusion Pilot Plant (FPP) of low-aspect ratio spherical tokamak (ST) or compact stellarators. Unlike typical high field magnets for nuclear magnetic resonance (NMR), magnetic resonance imaging (MRI), or high energy physics research applications, neutron irradiation damage to organic insulations in the coil winding pack is a critical issue for next generation fusion reactors where orders of magnitude higher neutron fluence than those in present experimental reactors such as ITER are expected. Moreover, a high coil winding pack current density is needed for high field magnets in low cost, compact radial build next step fusion reactors. The slow current charging time, however, is an issue in fully non-insulated coils. In this work, we present the design, construction and testing of subscale Nb3Sn solenoids, up to half the diameter of the central solenoid (CS) for National Spherical Torus Experiment (NSTX), with and without inter-layer insulation for enhancing radiation resistance while improving the winding pack current density and coil performance. The major radius for the NSTX/NSTX-Upgrade (reference for compact ST) is 0.854/0.934 meter, and 4.8 meters for FNSF. The magnetic field for NSTX/NSTX-U at the plasma center is 0.6/1 Tesla and 9 Tesla for FNSF. The inner diameter of the central solenoid coil is 0.2/0.4 meter for NSTX/NSTX-U and 1.2 meters for FNSF. The current charging and discharging behavior of the prototype solenoids was investigated to quantify performance advantages of a simplified coil fabrication without error-prone vacuum pressure impregnation (VPI) for the removal of epoxy organic insulation. Scalability of the no insulation concept for fusion can be addressed via engineered coating for novel insulation on contact resistance or intra-layer no insulations. Radiation resistance and coil winding efficiency were significantly improved in the no insulation coils for next step compact fusion reactors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of cosmic ray events with high muon multiplicity using the ALICE detector at the CERN Large Hadron Collider

ALICE is one of four large experiments at the CERN Large Hadron Collider near Geneva, specially designed to study particle production in ultra-relativistic heavy-ion collisions. Located 52 meters underground with 28 meters of overburden rock, it has also been used to detect muons produced by cosmic ray interactions in the upper atmosphere. Here, we present the multiplicity distribution of these atmospheric muons and its comparison with Monte Carlo simulations. Our analysis exploits the large size and excellent tracking capability of the ALICE Time Projection Chamber. A special emphasis is given to the study of high multiplicity events containing more than 100 reconstructed muons and corresponding to a muon areal density rho(mu) > 5.9 m(-2). Similar events have been studied in previous underground experiments such as ALEPH and DELPHI at LEP. While these experiments were able to reproduce the measured muon multiplicity distribution with Monte Carlo simulations at low and intermediate multiplicities, their simulations failed to describe the frequency of the highest multiplicity events. In this work we show that the high multiplicity events observed in ALICE stem from primary cosmic rays with energies above 10(16) eV and that the frequency of these events can be successfully described by assuming a heavy mass composition of primary cosmic rays in this energy range. Furthermore, the development of the resulting air showers was simulated using the latest version of QGSJET to model hadronic interactions. This observation places significant constraints on alternative, more exotic, production mechanisms for these events.

43 PARTICLE ACCELERATORS↗

Coherent versus incoherent sequential quantum measurements

We compare a trade-off between knowledge and decoherence for the incoherent and coherent partial sequential compatible measurements on single-qubit systems. The individual partial measurement nondestructively monitors basis states of the system by single-qubit meter. For the same decoherence caused by this unbiased measurement, the individual coherent measurement gives more knowledge than the incoherent one. For identical sequential coherent measurements, knowledge accumulated not additively increases more slowly than for the incoherent measurements. The overall knowledge can be accumulated using an adaptive measurement strategy on the meters if the single-qubit coherence of meters is kept. On the other hand, preservation of the mutual qubit coherence between the meters necessary for the collective measurement strategy is not required. A loss of single-qubit coherence degrades the coherent measurements back to the incoherent ones. Since the decoherence caused by the measurement process is a quadratic function of knowledge extracted by the individual measurement, Zeno-like behavior can be observed for repetitive weak compatible measurements. This unconditional universal effect does not depend on any dynamics of the qubit and it is a direct consequence of optimally controlled sequential evolution of quantum information.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗