Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

MAGNETIC LIQUID DEFORMABLE MIRRORS FOR ASTRONOMICAL APPLICATIONS: ACTIVE CORRECTION OF OPTICAL ABERRATIONS FROM LOWER-GRADE OPTICS AND SUPPORT SYSTEM

Deformable mirrors are increasingly used in astronomy. However, they still are limited in stroke for active correction of high-amplitude optical aberrations. Magnetic liquid deformable mirrors (MLDMs) are a new technology that has the advantages of high-amplitude deformations and low costs. In this paper, we demonstrate extremely high strokes and interactuator strokes achievable by MLDMs which can be used in astronomical instrumentation. In particular, we consider the use of such a mirror to suggest an interesting application for the next generation of large telescopes. We present a prototype 91 actuator deformable mirror made of a magnetic liquid (ferrofluid). This mirror uses a technique that linearizes the response of such mirrors by superimposing a large and uniform magnetic field on the magnetic field produced by an array of small coils. We discuss experimental results that illustrate the performance of MLDMs. A most interesting application of MLDMs comes from the fact they could be used to correct the aberrations of large and lower optical quality primary mirrors held by simple support systems. We estimate basic parameters of the needed MLDMs, obtaining reasonable values.

79 ASTRONOMY AND ASTROPHYSICS↗

Atomic resolution scanning tunneling microscopy in a cryogen free dilution refrigerator at 15 mK

Pulse tube refrigerators are becoming more common, because they are cost efficient and demand less handling than conventional (wet) refrigerators. However, a downside of a pulse tube system is the vibration level at the cold-head, which is in most designs several micrometers. We implemented vibration isolation techniques which significantly reduced vibration levels at the experiment. These optimizations were necessary for the vibration sensitive magnetic resonance force microscopy experiments at milli-kelvin temperatures for which the cryostat is intended. With these modifications we show atomic resolution scanning tunneling microscopy on graphite. This is promising for scanning probe microscopy applications at very low temperatures.

42 ENGINEERING↗

A system for low field imaging of laser-polarized noble gas

We describe a device for performing MRI with laser-polarized noble gas at low magnetic fields (<50 G). The system is robust, portable, inexpensive, and provides gas-phase imaging resolution comparable to that of high field clinical instruments. At 20.6 G, we have imaged laser-polarized (3)He (Larmor frequency of 67 kHz) in both sealed glass cells and excised rat lungs, using approximately 0.1 G/cm gradients to achieve approximately 1 mm(2) resolution. In addition, we measured (3)He T(2)(*) times greater than 100 ms in excised rat lungs, which is roughly 20 times longer than typical values observed at high ( approximately 2 T) fields. We include a discussion of the practical considerations for working at low magnetic fields and conclude with evidence of radiation damping in this system. Copyright 1999 Academic Press.

NASA Program Biomedical Research and Countermeasur↗

High-sensitivity cooled coil system for nuclear magnetic resonance in kHz range

In several low-field Nuclear Magnetic Resonance (LF-NMR) and surface nuclear magnetic resonance applications, i.e., in the frequency range of kHz, high sensitivity magnetic field detectors are needed. Usually, low-T{sub c} superconducting quantum interference devices (SQUIDs) with a high field sensitivity of about 1 fT/Hz{sup 1/2} are employed as detectors. Considering the flux trapping and operational difficulties associated with low-T{sub c} SQUIDs, we designed and fabricated liquid-nitrogen-cooled Cu coils for NMR detection in the kHz range. A cooled coil system consisting of a 9-cm diameter Cu coil and a low noise preamplifier was systematically investigated and reached a sensitivity of 2 fT/Hz{sup 1/2} at 77 K, which is 3 times better compared to the sensitivity at 300 K. A Q-switch circuit as an essential element for damping the ringing effects of the pickup coil was developed to acquire free induction decay signals of a water sample with minimum loss of signal. Our studies demonstrate that cooled Cu coils, if designed properly, can provide a comparable sensitivity to low-T{sub c} SQUIDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High resolution diagnostic tools for superconducting radio frequency cavities

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 –10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two high-resolution diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system, which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. This setup has a spatial resolution of ~ 13 μm in the azimuthal direction and ~ 1 cm along the cavity contour. The second setup is a stationary, combined magnetic and temperature mapping system, which uses anisotropic magnetoresistance sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. This system has a spatial resolution of 5 mm close to the iris and 11 mm at the equator. Initial results show a non-uniform distribution of trapped flux on the cavities’ surfaces, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Focusing of nonducted whistlers by the equatorial anomaly

Impulsive ELF/VLF electric field bursts observed by the vector electric field instrument (VEFI) on the Dynamics Explorer 2 (DE 2) satellite on almost every crossing of the geomagnetic equator in the evening hours are interpreted as originating in lightning discharges. These signals that peak in intensity near the magnetic equator are observed within 5-20 deg latitude of the geomagnetic equator at altitudes of 300-500 km with amplitudes of the order of approximately mV/m in the 512- or 1024-Hz frequency band of the VEFI instrument. Whistler-mode ELF/VLF wave propagation through a horizontally stratified ionosphere predicts strong attenuation of subionospheric signals reaching the equator at low altitudes. However, ray tracing analysis shows that the presence of the equatorial density anomaly, commonly observed in the upper ionosphere during evening hours, leads to the focusing of the wave energy from lightning near the geomagnetic equator at low altitudes, thus accounting for all observed aspects of the phenomenon. The observations presented here indicate that during certain hours in the evening, almost all the energy input from lightning discharges entering the ionosphere at less than 30 deg latitude remains confined to a small region (in altitude and latitude) near the geomagnetic equator. The net wideband electric field, extrapolated from the observed electric field values in the 512- to 1024-Hz band, can be approximately 10 mV/m or higher. These strong electric fields generated in the ionosphere by lightning at local evening times may be important for the equatorial electrodynamics of the ionosphere.

Sonwalkar, Vikas S.↗

Sensitivity to neutrino mixing parameters with atmospheric neutrinos

We have analyzed the atmospheric neutrino data to study the octant of {theta}{sub 23} and the precision of the oscillation parameters for a large iron calorimeter detector. The iron calorimeter being a tracking detector has the ability to measure the energy and the direction of the muon with high resolution. From bending of the track in the magnetic field it can also distinguish its charge. We have generated events by Nuance and then considered only the muons (directly measurable quantities) produced in charge current interactions in our analysis. This encounters the main problem of wide resolutions of energy and baseline. The energy-angle correlated two-dimensional resolution functions are used to migrate the energy and the zenith angle of the neutrino to those of the muon. A new type of binning has been introduced to get better reflection of the oscillation pattern in {chi}{sup 2} analysis. Then the marginalization of the {chi}{sup 2} over all parameters has been carried out for neutrinos and antineutrinos separately. We find that the measurement of {theta}{sub 13} is possible at a significant precision with atmospheric neutrinos. The precisions of {delta}m{sub 32}{sup 2} and sin{sup 2}{theta}{sub 23} are found {approx}8% and 38%, respectively, at 90% C.L. The discrimination of the octant as well as the deviation from maximal mixing of atmospheric neutrinos is also possible for some combinations of ({theta}{sub 23},{theta}{sub 13}). We also discuss the impact of the events at near horizon on the precision studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An investigation of short period oscillations of the solar irradiance and their time variations

Measurements of solar irradiance fluctuations by the Active Cavity Radiometer (ACRIM) instrument onboard the Solar Maximum Mission (SMM) show variations on a time scale of about 5 minutes due to solar p-mode oscillations, as well as longer-term variations related to solar magnetic activity. The question was studied whether the p-mode frequencies change with time as a result of changing solar structure associated with the activity cycle. The ACRIM data on SMM are particularly well-suited for this purpose, because the instrument operated continuously from February 1980 to December 1980 and again from May 1984 to the present. The main activity entailed a detailed study of the observational data to determine if a change in the p-mode frequencies is evident from the time of solar maximum to that of solar minimum. It was concluded that the measured eigenfrequencies were significantly higher during the 1980 time frame than during the 1984 to 1986 time frame. The conclusion that there is significant change in the eigenfrequencies with the activity cycle remains only tentative, and needs confirmation from analysis of more data during the upcoming solar maximum.

Noyes, Robert W.↗

Design, development, and results from a charge-collector diagnostic for a toroidal electron plasma experiment

A suitable charge-collector has been designed and developed to estimate charge-content of electron plasmas in a Small Aspect Ratio Toroidal Experiment in a C-shaped trap (SMARTEX-C). The electrons are periodically injected and held in the trap with the aid of electrostatic end-fields and a toroidal magnetic field. After a preset “hold” time, the trapped charges are dumped onto a grounded collector (by gating it). As the charges flow along the magnetic field lines onto the collector, the integrated current gives the charge-content of the plasma at the instant of dump. In designing such a charge collector, several challenges peculiar to the geometry of the trap and the nature of the plasma had to be addressed. Instantaneous charge measurements synchronised with the E × B drift of the plasma, along with fast transit times of electrons to the collector (few 100 ns or less) (due to the low aspect ratio of the trap) essentially require fast gating of the collector. The resulting large capacitive transients alongside low charge content (few nC) of such plasmas further lead to increasing demands on response and sensitivity of the collector. Complete cancellation of such transients is shown to be possible, in principle, by including the return path in our measurement circuit but the “non-neutrality” of the plasma acts as a further impediment. Ultimately, appropriate shielding and measurement circuits allow us to (re)distribute the capacitance and delineate the paths of these currents, leading to effective cancellation of transients and marked improvement in sensitivity. Improved charge-collector has thus been used to successfully estimate the time evolution of total charge of the confined electron plasma in SMARTEX-C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of the Heliospheric Radial Magnetic Field from the Standoff Distance of a CME-Driven Shock Observed by the Stereo Spacecraft

We report on the determination of radial magnetic field strength in the heliocentric distance range from 6 to 120 solar radii (R-solar) using data from Coronagraph 2 (COR2) and Heliospheric Imager I (HI1) instruments on board the Solar Terrestrial Relations Observatory spacecraft following the standoff-distance method of Gopalswamy & Yashiro. We measured the shock standoff distance of the 2008 April 5 coronal mass ejection (CME) and determined the flux-rope curvature by fitting the three-dimensional shape of the CME using the Graduated Cylindrical Shell model. The radial magnetic field strength is computed from the Alfven speed and the density of the ambient medium. We also compare the derived magnetic field strength with in situ measurements made by the Helios spacecraft, which measured the magnetic field at the heliocentric distance range from 60 to 215 R-solar.We found that the radial magnetic field strength decreases from 28 mG at 6 R-solar to 0.17 mG at 120 R-solar. In addition, we found that the radial profile can be described by a power law.

CMEs↗

Ion Accumulation Approaches for Increasing Sensitivity and Dynamic Range in the Analysis of Complex Samples

EXTERNAL ACCUMULATION OF IONS FOR FTICR DETECTION The need for higher mass accuracy and precision in analysis of e.g. biological compounds is now commonly addressed by storing charged particles in an ion trap using a superposition of the constant static magnetic and spatially inhomogeneous electric fields, often referred to as Penning trap. The Penning trap has been successfully employed in Fourier Transform Ion Cyclotron Resonance (FTICR) MS instrumentation. Since its inception in 1973,1 FTICR has been the subject of multiple reviews,2-9 several journal issues10,11 and books12,13 that give a full-range technical introduction to both single ion and more populated ion clouds (a group of ions who’s motion is to some extent influenced by the other ions in the cloud) behavior in combined magnetic and electric fields, subsequent signal processing, and technique applications. Principles and design of geometric and electrical configurations of ICR traps have been also reviewed.14 The reader is referred to these publications for more information. Herein, we will give a brief overview of the ion cloud behavior in the superimposed magnetic and electric fields, with an emphasis on ICR trap design, and highlight FTICR performance improvements due to accumulation of ions in another trap external to FTICR.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The MAGNEX large acceptance spectrometer

The main features of the MAGNEX large acceptance magnetic spectrometer are described. It has a quadrupole + dipole layout and a hybrid detector located at the focal plane. The aberrations due to the large angular (50 msr) and momentum (+- 13%) acceptance are reduced by an accurate hardware design and then compensated by an innovative software ray-reconstruction technique. The obtained resolution in energy, angle and mass are presented in the paper. MAGNEX has been used up to now for different experiments in nuclear physics and astrophysics confirming to be a multipurpose device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An electron/ion spectrometer with the ability of low energy electron measurement for fast ignition experiments

An electron energy spectrometer (ESM) is one of the most fundamental diagnostics in the fast ignition experiment. It is necessary to observe the spectra down to a low energy range in order to obtain the accurate deposition efficiency toward the core. Here, we realize the suitable ESM by using a ferrite magnet with a moderate magnetic field of 0.3 T and a rectangular magnetic circuit covered with a steel plate in the inlet side.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An interchangeable scanning Hall probe/scanning SQUID microscope

We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10{sup −7} T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La{sub 2/3}Ca{sub 1/3}MnO{sub 3} thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-screen single-shot electron spectrometer for laser wakefield accelerated electron beams

The laser wakefield acceleration electron beams can essentially deviate from the axis of the system, which distinguishes them greatly from beams of conventional accelerators. In case of energy measurements by means of a permanent-magnet electron spectrometer, the deviation angle can affect accuracy, especially for high energies. A two-screen single-shot electron spectrometer that correctly allows for variations of the angle of entry is considered. The spectrometer design enables enhancing accuracy of measuring narrow electron beams significantly as compared to a one-screen spectrometer with analogous magnetic field, size, and angular acceptance.

43 PARTICLE ACCELERATORS↗

DETERMINATION OF THE HELIOSPHERIC RADIAL MAGNETIC FIELD FROM THE STANDOFF DISTANCE OF A CME-DRIVEN SHOCK OBSERVED BY THE STEREO SPACECRAFT

We report on the determination of radial magnetic field strength in the heliocentric distance range from 6 to 120 solar radii (R {sub Sun }) using data from Coronagraph 2 (COR2) and Heliospheric Imager I (HI1) instruments on board the Solar Terrestrial Relations Observatory spacecraft following the standoff-distance method of Gopalswamy and Yashiro. We measured the shock standoff distance of the 2008 April 5 coronal mass ejection (CME) and determined the flux-rope curvature by fitting the three-dimensional shape of the CME using the Graduated Cylindrical Shell model. The radial magnetic field strength is computed from the Alfven speed and the density of the ambient medium. We also compare the derived magnetic field strength with in situ measurements made by the Helios spacecraft, which measured the magnetic field at the heliocentric distance range from 60 to 215 R {sub Sun }. We found that the radial magnetic field strength decreases from 28 mG at 6 R {sub Sun} to 0.17 mG at 120 R {sub Sun }. In addition, we found that the radial profile can be described by a power law.

79 ASTRONOMY AND ASTROPHYSICS↗

The application of wavelet shrinkage denoising to magnetic Barkhausen noise measurements

The application of Magnetic Barkhausen Noise (MBN) as a non-destructive method of defect detection has proliferated throughout the manufacturing community. Instrument technology and measurement methodology have matured commensurately as applications have moved from the R and D labs to the fully automated manufacturing environment. These new applications present a new set of challenges including a bevy of error sources. A significant obstacle in many industrial applications is a decrease in signal to noise ratio due to (i) environmental EMI and (II) compromises in sensor design for the purposes of automation. The stochastic nature of MBN presents a challenge to any method of noise reduction. An application of wavelet shrinkage denoising is proposed as a method of decreasing extraneous noise in MBN measurements. The method is tested and yields marked improvement on measurements subject to EMI, grounding noise, and even measurements in ideal conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Individual NSLS-II Multipole Magnet Alignment by Laser Trackers

The magnet alignment of the 90 th and final multipole girder assembly was completed January 17 th , 2013. Our procedure of “rough” pre-alignment by laser trackers and final alignment by vibrating wire & “Differential Variable Reluctance Transducers” (DVRT) has been quite successful, achieving magnet to magnet alignment well under the 30 micron specification. The pre-alignment accuracy is verified by the initial scan from the vibrating wire. The alignment residuals can be calculated from the offsets of a best fit line. The results are impressive, especially considering the environment of the Building 902 Annex (which has a large bay door that would open during pre-alignment, without fail), the sloppiness of the magnets’ fiducials, and especially the fact that the girders were pre-aligned to their mechanical centers, but the vibrating wire reports the magnetic centers which may be considerably different. This result hints at the potential feasibility of alignment with laser trackers for replacement magnets of NSLS-II and maybe even all magnets of future accelerators. But, it is difficult to predict the achievable accuracy until the main three error sources (a.k.a. Survey group excuses) are eliminated: measuring environment, bad magnet fiducials, and mechanical/magnetic center differences. The test performed on a large aperture quadrupole on girder assembly C19G4 was designed to answer the following questions with the aforementioned error sources either eliminated or simulated: 1) How accurately can a NSLS-II multipole be realigned after repair or other disturbance given the existing fiducials? 2) How accurately can a replacement NSLS-II multipole be installed in situ if its magnetic center is known relative to good fiducials? 3) If the current NSLS-II spares are never magnetically fiducialized, how well can they be installed using only mechanical data? 4) Could the magnets of a future accelerator (with similar alignment specifications as NSLS-II) be aligned using commercially available metrology instruments? This paper will answer these questions.

36 MATERIALS SCIENCE↗