Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Magnetic frustration driven by conduction carrier blocking in Nd 2 Co 0.85 Si 2.88

The intermetallic compound Nd 2 Co 0.85 Si 2.88 having a triangular lattice could be synthesized in single phase only with defect crystal structure. Investigation through different experimental techniques indicate the presence of two magnetic transitions in the system. As verified experimentally and theoretically, the high-temperature transition $T_H$ ~ 140 K is associated with the development of ferromagnetic interaction between itinerant Co moments, whereas the low-temperature transition at $T_L$ ~ 6.5 K is due to the coupling among Nd–4$\textit{f}$ and Co–3$\textit{d}$ moments, which is antiferromagnetic in nature. Detailed studies of temperature-dependent dc magnetic susceptibility, field dependence of isothermal magnetization, nonequilibrium dynamical behavior, viz., magnetic relaxation, aging effect, magnetic-memory effect, and temperature dependence of heat capacity, along with density functional theory (DFT) calculations, suggest that the ground state is magnetically frustrated spin glass in nature, having competing magnetic interactions of equivalent energies. DFT results further reveal that the 3$\textit{d}$/5$\textit{d}$-conduction carriers are blocked in the system and act as a barrier for the 4$\textit{f}$–4$\textit{f}$ RKKY interactions, resulting in spin frustration. Presence of vacancy defects in the crystal are also conducive to the spin frustration. This is an unique mechanism of magnetic frustration, not emphasized so far in any of the ternary $R_2TX_3$ ($\textit{R}$ = rare earth, $\textit{T}$ = transition elements, and $\textit{X}$ = Si, Ge, In) type compounds. Due to the competing character of the itinerant 3$\textit{d}$ and localized 4$\textit{f}$ moments, the compound exhibits anomalous field dependence of magnetic coercivity. Further, the system also exhibits a considerable magnetic entropy change of –Δ$S_M$ ~ 13.3 J/kg K with a relative cooling power (RCP) of 220 J/kg and adiabatic temperature change $ΔT_{\text{ad}}$ of 6 K for magnetic field change of 70 kOe.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Neutron Scattering Experiment Automation with Python

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory currently holds the Guinness World Record as the world most powerful pulsed spallation neutron source. Neutrons scattered off atomic nuclei in a sample yield important information about the position, motions, and magnetic properties of atoms in materials. A neutron scattering experiment usually involves sample environment control (temperature, pressure, etc.), mechanical alignment (slits, sample and detector position), magnetic field controllers, neutron velocity selection (choppers) and neutron detectors. The SNS Data Acquisition System (DAS) consists of real-time sub-system (detector read-out with custom electronics, chopper interface), data preprocessing (soft real-time) and a cluster of control and ancillary PCs. The real-time system runs FPGA firmware and programs running on PCs (C++, LabView) typically perform one task such as motor control and communicate via TCP/IP networks. PyDas is a set of Python modules that are used to integrate various components of the SNS DAS system. It enables customized automation of neutron scattering experiments in a rapid and flexible manner. It provides wxPython GUIs for routine experiments as well as IPython command line scripting. Matplotlib and numpy are used for data presentation and simple analysis. We will present an overview of SNS Data Acquisition System and PyDas architectures and implementation along with the examples of use. We will also discuss plans for future development as well as the challenges that have to be met while maintaining PyDas for 20+ different scientific instruments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Chemical tuning of a honeycomb magnet through a critical point

BaCo 2⁢ (AsO 4 )⁢ 2 (BCAO) has seen extensive study since its initial identification as a proximate Kitaev quantum spin liquid candidate. Thought to be described by the highly anisotropic XXZ-J 1 -J 3 model, the ease with which magnetic order is suppressed in the system indicates proximity to a spin liquid phase. Upon chemical tuning via partial arsenic substitution with vanadium, we show an initial suppression of long-range incommensurate order in the BCAO system to T ≈ 3.0 K, followed by increased spin freezing at higher substitution levels. Between these two regions, at around 10% substitution, the system is shown to pass through a critical point where the competing J 1 /J 3 exchange interactions become more balanced, producing a more complex magnetic ground state, likely stabilized by quantum fluctuations. Here, this state shows how slight compositional change in magnetically frustrated systems may be leveraged to tune ground state degeneracies and potentially realize a quantum spin liquid state.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First-Principles Studies on Sc 2 RuZ (Z = Si, Ge, Sn) Inverse Heusler Alloys: Structural, Electronic, and Transport Properties

The continuous demand for efficient, nontoxic, and thermally stable materials for room-temperature energy conversion motivates the exploration of novel thermoelectric systems beyond the traditional magnetic Heusler alloys. While full and half-Heusler compounds, especially Co-, Ni-, and Mn-based systems, have demonstrated promising thermoelectric properties, their typically high operating temperatures and magnetic complexities limit their applicability in ambient thermal management. In this context, we investigate whether Sc-based inverse Heusler alloys can offer a viable nonmagnetic alternative with competitive thermoelectric performance. In this work, we perform a systematic first-principles study of the inverse Heusler compounds Sc 2 RuZ (Z = Si, Ge, Sn), focusing on their structural, electronic, mechanical, and thermodynamic-thermoelectric properties. Density Functional Theory (DFT) was employed to compute optimized lattice structures and band dispersion, while dynamical stability was assessed via phonon calculations. Thermoelectric transport coefficients, including Seebeck coefficient, electrical conductivity, and thermal conductivity, were estimated using the semiclassical Boltzmann transport theory within the constant relaxation time approximation. Our results show that all Sc 2 RuZ compounds are thermodynamically stable semiconductors with indirect band gaps of 0.12–0.16 eV and exhibit high elastic moduli, especially Sc 2 RuSn, which demonstrates superior stiffness and incompressibility. Importantly, all compounds display promising room-temperature thermoelectric characteristics, including high Seebeck coefficients and power factors. These findings reveal that Sc 2 RuZ alloys represent a rare class of stable, nonmagnetic inverse Heusler semiconductors with intrinsic thermoelectric potential at room temperature, unlike many existing Heusler systems optimized for spintronics or high-temperature operation. This work expands the known design space for Heusler-based thermoelectrics and offers a theoretical basis for experimental realization of efficient, low-temperature, nonmagnetic thermoelectric materials.

alloys↗

Automated setup for magnetic hysteresis characterization based on a voltage controlled current source with 500 kHz full power bandwidth and 10 A peak-to-peak current

This paper describes the design of a system for the characterization of magnetic hysteresis behavior in soft ferrite magnetic cores. The proposed setup can test magnetic materials exciting them with controlled arbitrary magnetic field waveforms, including the capability of providing a DC bias, in a frequency bandwidth up to 500 kHz, with voltages up to 32 V peak-to-peak, and currents up to 10 A peak-to-peak. In order to have an accurate control of the magnetic field waveform, the system is based on a voltage controlled current source. The electronic design is described focusing on closed loop feedback stabilization and passive components choice. The system has real-time hysteretic loop acquisition and visualization. The comparisons between measured hysteresis loops of sample magnetic materials and datasheet available ones are shown. Results showing frequency and thermal behavior of the hysteresis of a test sample prove the system capabilities. Moreover, the B-H loops obtained with a multiple waveforms excitation signal, including DC bias, are reported. The proposal is a low-cost and replicable solution for hysteresis characterization of magnetic materials used in power electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Avalanche Detector using Single-Molecule Magnets

Here we discuss the results of the 9 month add-on project: “Magnetic Avalanche Detector using Single-Molecule Magnets”. The key point of the projects was to design a cryogenic system that is capable of applying magnetic fields high enough to magnetize the Single-Molecule Magnets (SMMs), maintain temperatures below 1K, and be able to detect magnetic avalanches of the SMM domains. We were able to achieve these goals. Our system was able to magnetize and sense the magnetization of SMM crystals. Moreover, we were able to detect avalanche demagnetization events caused by an alpha particle interacting with a magnetized SMM.

47 OTHER INSTRUMENTATION↗

Design of pulsed guiding magnetic field for high power microwave generators

In this paper, we present a comprehensive study on designing solenoid together with the corresponding power supply system to excite pulsed magnetic field required for high power microwave generators. Particularly, a solenoid is designed and the excited magnetic field is applied to a Ku-band overmoded Cerenkov generator. It is found in experiment that the electron beam is properly guided by the magnetic field and a 1.1 GW high power microwave is achieved at a central frequency of 13.76 GHz. Pulsed solenoid system has the advantages of compactness and low energy consumption, which are of great interest for repetitive operation. The reported studies and results can be generalized to other applications which require magnetic fields.

43 PARTICLE ACCELERATORS↗

Signal Differentiation of Moving Magnetic Nanoparticles for Enhanced Biodetection and Diagnostics

Magnetic nanoparticles are extensively utilized as markers/signal labelling in various biomedical applications. Detecting and distinguishing magnetic signals from similarly sized moving magnetic nanoparticles in microfluidic systems is crucial yet challenging for biosensing. In this study, we have developed an original method to detect and differentiate magnetic signals from moving superparamagnetic (SPM) and ferrimagnetic (FM) nanoparticles of comparable sizes. Our approach utilizes a highly sensitive magnetic-coil-based sensor that harnesses the combined effects of giant magnetoimpedance (GMI) and an LC-resonance circuit, offering performance superior to that of conventional GMI sensors. Iron oxide nanoparticles, which have similar particle sizes but differing coercivities (zero for SPM and non-zero for FM) or similar zero coercivities but differing particle sizes, flow through the magnetic coil at controlled velocities. Their distinct effects are analyzed through changes in the complex impedance of the sensing system. Our findings provide a unique pathway for utilizing SPM and FM nanoparticles as innovative magnetic markers to identify specific biological entities, thereby expanding their potential applications.

Hwang, Kee Young↗

Manipulation of competing ferromagnetic and antiferromagnetic domains in exchange-biased nanostructures

In this work, using photoemission electron microscopy combined with x-ray magnetic circular dichroism we show that a progressive spatial confinement of a ferromagnet (FM), either through thickness variation or laterally via patterning, actively controls the domains of uncompensated spins in the antiferromagnet (AF) in exchange-biased systems. Direct observations of the spin structure in both sides of the FM/AF interface in a model system, Ni/FeF 2 , show that the spin structure is determined by the balance between the competing FM and AF magnetic energies. Coexistence of exchange bias domains, with opposite directions, can be established in Ni/FeF 2 bilayers for Ni thicknesses below 10 nm. Patterning the Ni/FeF 2 heterostructures with antidots destabilizes the FM state, enhancing the formation of opposite exchange bias domains below a critical antidot separation of the order of a few FeF 2 crystal domains. The results suggest that dimensional confinement of the FM may be used to manipulate the AF spin structure in spintronic devices and ultrahigh-density information storage media. Lastly, the underlying mechanism of the uncompensated AF domain formation in Ni/FeF 2 may be generic to other magnetic systems with complex noncollinear FM/AF spin structures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TU-H-BRA-01: The Physics of High Power Radiofrequency Isolation in a Novel Compact Linear Accelerator Based MRI Guided Radiation Therapy System

Purpose: To develop a method for isolating the radiofrequency waves emanating from linear accelerator components from the magnetic resonance imaging (MRI) system of an integrated MRI-linac. Methods: An MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. The radiofrequency waves created by the accelerating process would degrade MR image quality, so a method for containing the radiofrequency waves and isolating the MR imager from them was developed. The linear accelerator radiofrequency modulator was placed outside the room, so a filter was designed to eliminate the radiofrequency corresponding to the proton Larmour frequency of 14.7 MHz. Placing the radiofrequency emitting components in a typical Faraday cage would have reduced the radiofrequency emissions, but the design would be susceptible to small gaps in the shield due to the efficiency of the Faraday cage reflecting internal radiofrequency emissions. To reduce internal radiofrequency reflections, the Faraday cage was lined with carbon fiber sheets. Carbon fiber has the property of attenuating the radiofrequency energy so that the overall radiofrequency field inside the Faraday cage is reduced, decreasing any radiofrequency energy emitted from small gaps in the cage walls. Results: Within a 1.2 MHz band centered on the Larmor frequency, the radiofrequency (RF) leakage from the Faraday cage was measured to be −90 dB with no RF on, −40 dB with the RF on and no shield, returning to −90 dB with the RF on and shields in place. The radiofrequency filter attenuated the linear accelerator modulator emissions in the 14.7 MHz band by 70 dB. Conclusions: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of isolating the high power RF system from the MRI, has been solved. The measured radiofrequency emissions are sufficiently small to enable system integration. This research was funded by ViewRay, Inc., Oakwood, OH.

60 APPLIED LIFE SCIENCES↗

The Fermilab Muon g-2 experiment: laser calibration system

The anomalous muon dipole magnetic moment can be measured (and calculated) with great precision thus providing insight on the Standard Model and new physics. Currently an experiment is under construction at Fermilab (U.S.A.) which is expected to measure the anomalous muon dipole magnetic moment with unprecedented precision. One of the improvements with respect to the previous experiments is expected to come from the laser calibration system which has been designed and constructed by the Italian part of the collaboration (INFN). Furthermore, an emphasis of this paper will be on the calibration system that is in the final stages of construction as well as the experiment which is expected to start data taking this year.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RHIC 10 Hz global orbit feedback system

Vibrations of the cryogenic triplet magnets at the Relativistic Heavy Ion Collider (RHIC) are suspected to be causing the horizontal beam perturbations observed at frequencies around 10 Hz. Several solutions to counteract the effect have been considered in the past, including a local beam feedback system at each of the two experimental areas, reinforcing the magnet base support assembly, and a mechanical servo feedback system. However, the local feedback system was insufficient because perturbation amplitudes outside the experimental areas were still problematic, and the mechanical solutions are very expensive. A global 10 Hz orbit feedback system consisting of 36 beam position monitors (BPMs) and 12 small dedicated dipole corrector magnets in each of the two 3.8 km circumference counter-rotating rings has been developed and commissioned in February 2011. A description of the system architecture and results with beam will be discussed.

43 PARTICLE ACCELERATORS↗

An O ( N ) and parallel approach to integral problems by a kernel-independent fast multipole method: Application to polarization and magnetization of interacting particles

Large classes of materials systems in physics and engineering are governed by magnetic and electrostatic interactions. Continuum or mesoscale descriptions of such systems can be cast in terms of integral equations, whose direct computational evaluation requires O ( N 2 ) operations, where N is the number of unknowns. Such a scaling, which arises from the many-body nature of the relevant Green's function, has precluded wide-spread adoption of integral methods for solution of large-scale scientific and engineering problems. In this work, a parallel computational approach is presented that relies on using scalable open source libraries and utilizes a kernel-independent Fast Multipole Method (FMM) to evaluate the integrals in O ( N ) operations, with O ( N ) memory cost, thereby substantially improving the scalability and efficiency of computational integral methods. We demonstrate the accuracy, efficiency, and scalability of our approach in the context of two examples. In the first, we solve a boundary value problem for a ferroelectric/ferromagnetic volume in free space. In the second, we solve an electrostatic problem involving polarizable dielectric bodies in an unbounded dielectric medium. Lastly, the results from these test cases show that our proposed parallel approach, which is built on a kernel-independent FMM, can enable highly efficient and accurate simulations and allow for considerable flexibility in a broad range of applications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-resolved investigation of dual high power impulse magnetron sputtering with closed magnetic field during deposition of Ti-Cu thin films

Time-resolved comparative study of dual magnetron sputtering (dual-MS) and dual high power impulse magnetron sputtering (dual-HiPIMS) systems arranged with closed magnetic field is presented. The dual-MS system was operated with a repetition frequency 4.65 kHz (duty cycle {approx_equal}50%). The frequency during dual-HiPIMS is lower as well as its duty cycle (f=100 Hz, duty 1%). Different metallic targets (Ti, Cu) and different cathode voltages were applied to get required stoichiometry of Ti-Cu thin films. The plasma parameters of the interspace between magnetrons in the substrate position were investigated by time-resolved optical emission spectroscopy, Langmuir probe technique, and measurement of ion fluxes to the substrate. It is shown that plasma density as well as ion flux is higher about two orders of magnitude in dual-HiPIMS system. This fact is partially caused by low diffusion of ionized sputtered particles (Ti{sup +},Cu{sup +}) which creates a preionized medium.

36 MATERIALS SCIENCE↗

Oscillating plasma bubble and its associated nonlinear studies in presence of low magnetic field

Oscillating plasma bubbles have been created around a cylindrical mesh grid of 75% optical transparency in a DC plasma system with a low magnetic field. Plasma bubbles are created by developing ion density gradient around a cylindrical grid of 20 cm in diameter and 25 cm in height, inserted into the plasma. Relaxation and contraction of the plasma bubbles in the presence of external conditions, such as magnetic field and pressure, have been studied. A Langmuir probe has been used to detect the plasma floating potential fluctuations at different imposed experimental conditions. Nonlinear behavior of the system has been characterized by adopting nonlinear techniques such as Fast Fourier Transform, Phase Space Plot, and Recurrence Plot. It shows that the system creates highly nonlinear phenomena associated with the plasma bubble under the imposed experimental conditions. A theoretical and numerical model has also been developed to satisfy the observed experimental analysis. Moreover, observations are extended further to study the growth of instability associated with the plasma bubbles. The intention of the present work is to correlate the findings about plasma bubbles and their related instability with the one existing in the equatorial F-region of the ionosphere.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Domain-Wall Movement Control in Co/Au Multilayers by He{sup +}-Ion-Bombardment-Induced Lateral Coercivity Gradients

Defined perpendicular anisotropy gradients in the Co sublayers of a [Co(0.6 nm)/Au(2 nm)]{sub 3} sputter-deposited multilayer have been introduced by light ion bombardment through a wedged Au stopper layer. Within such a layer system, domain walls between up- and down-magnetized areas are controllably movable by an external perpendicular homogeneous magnetic field. This method and layer system is very promising for a controlled magnetic particle transport within the stray fields of the moving domain walls.

36 MATERIALS SCIENCE↗

Guided Self-Assembly and Control of Vortices in Ensembles of Active Magnetic Rollers

Active magnetic colloids are capable of rich collective behavior and complex self-organization. The interplay between short- and long-range interactions taking place away from equilibrium often results in a spontaneous formation of localized dynamic microstructures. Here we report a method for guided self-assembly and control of self-organized colloidal vortices emerging in a ferromagnetic particle ensemble energized by a uniaxial alternating (ac) magnetic field. The structure of a vortex composed of rolling magnetic particles can be stabilized and manipulated by means of an additional strongly localized alternating magnetic field provided by a minicoil. By tuning the parameters of the localized field, we effectively control the dimensions and particle number density in the vortex. We find that the roller vortex self-organization is assisted by field-induced magnetic "steering" rather than magnetic field gradients and is only possible while the system is in the active (magnetic rollers) state. In this work, we demonstrate that parameters of the emergent vortex are efficiently tuned by a phase shift between alternating magnetic fields. Overall, the method for assisted self-organization of rolling magnetic colloids into a vortex with on-demand characteristics suggests a new tool for active matter control and manipulation that may lead to a development of new approaches toward the guided microscopic transport in active particle systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Decoration of Fe3O4 and CoWO4 nanoparticles over graphitic carbon nitride: Novel visible-light-responsive photocatalysts with exceptional photocatalytic performances

Highlights: • g-C{sub 3}N{sub 4}/Fe{sub 3}O{sub 4}/CoWO{sub 4} nanocomposites as efficient photocatalysts are reported. • The g-C{sub 3}N{sub 4}/Fe{sub 3}O{sub 4}/NiWO{sub 4} (10%) nanocomposite exhibited the highest activity. • Activity was 12.5-folds greater than g-C{sub 3}N{sub 4} in RhB degradation under visible light. • The nanocomposite is magnetically separated from the treated solution. - Abstract: In this work, nanoparticles of Fe{sub 3}O{sub 4} and CoWO{sub 4} were decorated over graphitic carbon nitride (g-C{sub 3}N{sub 4}) to fabricate very efficient visible-light-responsive photocatalysts through a facile refluxing-calcination method. Among the fabricated photocatalysts, the g-C{sub 3}N{sub 4}/Fe{sub 3}O{sub 4}/CoWO{sub 4} (10%) nanocomposite displayed superior activity in degradation of RhB, which is 12.5 and 11.5 times superior than the pristine g-C{sub 3}N{sub 4} and g-C{sub 3}N{sub 4}/Fe{sub 3}O{sub 4} photocatalysts, respectively. Additionally, exceptional performance of the ternary photocatalyst was confirmed in degradations of three organic pollutants under visible light. Higher harvesting ability of visible light and effective separation of electron/hole pairs from recombination are two main factors responsible for the observed exceptional photocatalytic activity of the ternary nanocomposite. Due to enough saturation magnetization of the ternary nanocomposite, the photocatalyst was entirely separated from the degradation system by a conventional magnet. Finally, photostability of the ternary photocatalyst during four successive runs was confirmed.

36 MATERIALS SCIENCE↗