Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

ON THE ORIGIN OF THE ANGULAR MOMENTUM PROPERTIES OF GAS AND DARK MATTER IN GALACTIC HALOS AND ITS IMPLICATIONS

We perform a set of non-radiative hydrodynamical simulations of merging spherical halos in order to understand the angular momentum (AM) properties of the galactic halos seen in cosmological simulations. The universal shape of AM distributions seen in simulations is found to be generically produced as a result of mergers. The universal shape is such that it has an excess of low AM material and hence cannot explain the exponential structure of disk galaxies. A resolution to this is suggested by the spatial distribution of low AM material which is found to be in the center and a conical region close to the axis of rotation. A mechanism that preferentially discards the material in the center and prevents the material along the poles from falling onto the disk is proposed as a solution. We implement a simple geometric criterion for the selective removal of low AM material and show that in order for 90% of halos to host exponential disks one has to reject at least 40% of material. Next, we explore the physical mechanisms responsible for distributing the AM within the halo during a merger. For dark matter there is an inside-out transfer of AM, whereas for gas there is an outside-in transfer, which is due to differences between collisionless and gas dynamics. This is responsible for the spin parameter {lambda} and the shape parameter {alpha} of AM distributions being higher for gas compared to dark matter. We also explain the apparent high spin of dark matter halos undergoing mergers and show that a criterion stricter than what is currently used would be required to detect such unrelaxed halos. Finally, we demonstrate that the misalignment of AM between gas and dark matter only occurs when the intrinsic spins of the merging halos are not aligned with the orbital AM of the system. The self-misalignment (orientation of AM when measured in radial shells not being constant), which could be the cause of warps and anomalous rotation in disks galaxies, also occurs under similar conditions. The frequency and amplitude of this misalignment are roughly consistent with the properties of warps seen in disk galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

28nm front end ASIC and 12” LGADs for 3D integration

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (≈10 μm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present the design and results from a 28 nm CMOS ASIC prototype, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. We also report on the co-design and characterization of reticle-scale LGAD sensors with 50 μm and 100 μm pixels and introduce the next 10k-pixel ASIC designed for full 3D integration. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

CT reconstruction techniques for improved accuracy of lung CT airway measurement

Purpose: To determine the impact of constrained reconstruction techniques on quantitative CT (qCT) of the lung parenchyma and airways for low x-ray radiation dose. Methods: Measurement of small airways with qCT remains a challenge, especially for low x-ray dose protocols. Images of the COPDGene quality assurance phantom (CTP698, The Phantom Laboratory, Salem, NY) were obtained using a GE discovery CT750 HD scanner for helical scans at x-ray radiation dose-equivalents ranging from 1 to 4.12 mSv (12–100 mA s current–time product). Other parameters were 40 mm collimation, 0.984 pitch, 0.5 s rotation, and 0.625 mm thickness. The phantom was sandwiched between 7.5 cm thick water attenuating phantoms for a total length of 20 cm to better simulate the scatter conditions of patient scans. Image data sets were reconstructed using STANDARD (STD), DETAIL, BONE, and EDGE algorithms for filtered back projection (FBP), 100% adaptive statistical iterative reconstruction (ASIR), and Veo reconstructions. Reduced (half) display field of view (DFOV) was used to increase sampling across airway phantom structures. Inner diameter (ID), wall area percent (WA%), and wall thickness (WT) measurements of eight airway mimicking tubes in the phantom, including a 2.5 mm ID (42.6 WA%, 0.4 mm WT), 3 mm ID (49.0 WA%, 0.6 mm WT), and 6 mm ID (49.0 WA%, 1.2 mm WT) were performed with Airway Inspector (Surgical Planning Laboratory, Brigham and Women’s Hospital, Boston, MA) using the phase congruency edge detection method. The average of individual measures at five central slices of the phantom was taken to reduce measurement error. Results: WA% measures were greatly overestimated while IDs were underestimated for the smaller airways, especially for reconstructions at full DFOV (36 cm) using the STD kernel, due to poor sampling and spatial resolution (0.7 mm pixel size). Despite low radiation dose, the ID of the 6 mm ID airway was consistently measured accurately for all methods other than STD FBP. Veo reconstructions showed slight improvement over STD FBP reconstructions (4%–9% increase in accuracy). The most improved ID and WA% measures were for the smaller airways, especially for low dose scans reconstructed at half DFOV (18 cm) with the EDGE algorithm in combination with 100% ASIR to mitigate noise. Using the BONE + ASIR at half BONE technique, measures improved by a factor of 2 over STD FBP even at a quarter of the x-ray dose. Conclusions: The flexibility of ASIR in combination with higher frequency algorithms, such as BONE, provided the greatest accuracy for conventional and low x-ray dose relative to FBP. Veo provided more modest improvement in qCT measures, likely due to its compatibility only with the smoother STD kernel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager

Purpose: The increasing need for better image quality and high spatial resolution for successful endovascular image-guided interventions (EIGIs) and the inherent limitations of the state-of-the-art detectors provide motivation to develop a detector system tailored to the specific, demanding requirements of neurointerventional applications.Method: A microangiographic fluoroscope (MAF) was developed to serve as a high-resolution, region-of-interest (ROI) x-ray imaging detector in conjunction with large lower-resolution full field-of-view (FOV) state-of-the-art x-ray detectors. The newly developed MAF is an indirect x-ray imaging detector capable of providing real-time images (30 frames per second) with high-resolution, high sensitivity, no lag and low instrumentation noise. It consists of a CCD camera coupled to a Gen 2 dual-stage microchannel plate light image intensifier (LII) through a fiber-optic taper. A 300 {mu}m thick CsI(Tl) phosphor serving as the front end is coupled to the LII. The LII is the key component of the MAF and the large variable gain provided by it enables the MAF to operate as a quantum-noise-limited detector for both fluoroscopy and angiography. Results: The linear cascade model was used to predict the theoretical performance of the MAF, and the theoretical prediction showed close agreement with experimental findings. Linear system metrics such as MTF and DQE were used to gauge the detector performance up to 10 cycles/mm. The measured zero frequency DQE(0) was 0.55 for an RQA5 spectrum. A total of 21 stages were identified for the whole imaging chain and each stage was characterized individually. Conclusions: The linear cascade model analysis provides insight into the imaging chain and may be useful for further development of the MAF detector. The preclinical testing of the prototype detector in animal procedures is showing encouraging results and points to the potential for significant impact on EIGIs when used in conjunction with a state-of-art flat panel detector (FPD).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-H-CAMPUS-IeP3-01: Simultaneous PET Restoration and PET/CT Co-Segmentation Using a Variational Method

Purpose: PET images are usually blurred due to the finite spatial resolution, while CT images suffer from low contrast. Segment a tumor from either a single PET or CT image is thus challenging. To make full use of the complementary information between PET and CT, we propose a novel variational method for simultaneous PET image restoration and PET/CT images co-segmentation. Methods: The proposed model was constructed based on the Γ-convergence approximation of Mumford-Shah (MS) segmentation model for PET/CT co-segmentation. Moreover, a PET de-blur process was integrated into the MS model to improve the segmentation accuracy. An interaction edge constraint term over the two modalities were specially designed to share the complementary information. The energy functional was iteratively optimized using an alternate minimization (AM) algorithm. The performance of the proposed method was validated on ten lung cancer cases and five esophageal cancer cases. The ground truth were manually delineated by an experienced radiation oncologist using the complementary visual features of PET and CT. The segmentation accuracy was evaluated by Dice similarity index (DSI) and volume error (VE). Results: The proposed method achieved an expected restoration result for PET image and satisfactory segmentation results for both PET and CT images. For lung cancer dataset, the average DSI (0.72) increased by 0.17 and 0.40 than single PET and CT segmentation. For esophageal cancer dataset, the average DSI (0.85) increased by 0.07 and 0.43 than single PET and CT segmentation. Conclusion: The proposed method took full advantage of the complementary information from PET and CT images. This work was supported in part by the National Cancer Institute Grants R01CA172638. Shan Tan and Laquan Li were supported in part by the National Natural Science Foundation of China, under Grant Nos. 60971112 and 61375018.

60 APPLIED LIFE SCIENCES↗

Use of Thallium to Identify Monovalent Cation Binding Sites in GroEL

GroEL is a bacterial chaperone protein that assembles into a homotetradecameric complex exhibiting D{sub 7} symmetry and utilizes the co-chaperone protein GroES and ATP hydrolysis to assist in the proper folding of a variety of cytosolic proteins. GroEL utilizes two metal cofactors, Mg{sup 2+} and K{sup +}, to bind and hydrolyze ATP. A K{sup +}-binding site has been proposed to be located next to the nucleotide-binding site, but the available structural data do not firmly support this conclusion. Moreover, more than one functionally significant K{sup +}-binding site may exist within GroEL. Because K{sup +} has important and complex effects on GroEL activity and is involved in both positive (intra-ring) and negative (inter-ring) cooperativity for ATP hydrolysis, it is important to determine the exact location of these cation-binding site(s) within GroEL. In this study, the K{sup +} mimetic Tl{sup +} was incorporated into GroEL crystals, a moderately redundant 3.94 {angstrom} resolution X-ray diffraction data set was collected from a single crystal and the strong anomalous scattering signal from the thallium ion was used to identify monovalent cation-binding sites. The results confirmed the previously proposed placement of K{sup +} next to the nucleotide-binding site and also identified additional binding sites that may be important for GroEL function and cooperativity. These findings also demonstrate the general usefulness of Tl{sup +} for the identification of monovalent cation-binding sites in protein crystal structures, even when the quality and resolution of the diffraction data are relatively low.

36 MATERIALS SCIENCE↗

Extreme low-temperature molecular beam epitaxy of ZnO-based quantum structures

We report on extreme low-temperature growth of ZnO by plasma-assisted molecular beam epitaxy. Epilayers and quantum well (QW) structures with very good structural and optical properties are prepared at substrate temperatures as low as 50 deg. C. The growth proceeds in a single crystalline layer-by-layer mode. ZnO QWs prepared on a-plane sapphire show bright excitonic luminescence with a very narrow linewidth of only 6 meV at 5 K. High-resolution transmission electron micrographs confirm that low-temperature single crystalline growth is not restricted to a particular surface termination of ZnO but works also for crystal growth along a nonpolar direction.

36 MATERIALS SCIENCE↗

Interpretation of the Si K{alpha} x-ray spectra accompanying the stopping of swift Ca ions in low-density SiO{sub 2} aerogel

This article presents a detailed analysis of the K{alpha} x-ray spectra of Si induced by 11.4 MeV/u Ca projectiles penetrating a low-density SiO{sub 2} aerogel target measured with high spectral and spatial resolution at the UNILAC accelerator at GSI-Darmstadt. The low-density material used in the experiment was crucial for the space-resolved studies of the Si x-ray radiation (for different energies of stopping Ca ions). The stopping length of the 11 MeV/u Ca ions reaches up to 10 mm in the low-density SiO{sub 2} aerogel, whereas in regular quartz solid targets it is about 100 times shorter. The analysis of the x-ray spectra emitted by the stopping medium has shown a high level of the L-shell ionization, especially in the later considered phase (E{sub p{approx}}5 MeV/u) of the stopping process. It has been further demonstrated that the population of the highly ionized states produced in the ion-atom collisions can be substantially reduced in the time between the collision and the x-ray emission due to the very intense rearrangement processes occurring in Si situated in the chemical environment of oxygen atoms. Moreover, comparison of the experimental values of the K{alpha} L-shell satellite energy shifts with the results of the multiconfiguration Dirac-Fock calculations allows us to find that Si valence electron configuration is enriched due to electron transfer from valence-electron-rich oxygen atoms into highly ionized silicon atoms. Our results indicate that the Coulomb explosion in a highly ionized track core is prevented by rapid neutralization in the femtosecond time scale.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spectroscopic Validation of Low-metallicity Stars from RAVE

We present results from a medium-resolution (R ∼ 2000) spectroscopic follow-up campaign of 1694 bright (V < 13.5), very metal-poor star candidates from the RAdial Velocity Experiment (RAVE). Initial selection of the low-metallicity targets was based on the stellar parameters published in RAVE Data Releases 4 and 5. Follow up was accomplished with the Gemini-N and Gemini-S, the ESO/NTT, the KPNO/Mayall, and the SOAR telescopes. The wavelength coverage for most of the observed spectra allows for the determination of carbon and α-element abundances, which are crucial for considering the nature and frequency of the carbon-enhanced metal-poor (CEMP) stars in this sample. We find that 88% of the observed stars have [Fe/H] ≤ −1.0, 61% have [Fe/H] ≤ −2.0, and 3% have [Fe/H] ≤ −3.0 (with four stars at [Fe/H] ≤ −3.5). There are 306 CEMP star candidates in this sample, and we identify 169 CEMP Group I, 131 CEMP Group II, and 6 CEMP Group III stars from the A(C) versus [Fe/H] diagram. Inspection of the [α/C] abundance ratios reveals that five of the CEMP Group II stars can be classified as “mono-enriched second-generation” stars. Gaia DR1 matches were found for 734 stars, and we show that transverse velocities can be used as a confirmatory selection criteria for low-metallicity candidates. Selected stars from our validated list are being followed-up with high-resolution spectroscopy to reveal their full chemical-abundance patterns for further studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Deformation of elastomeric pyramid pen arrays in cantilever-free scanning probe lithography

Cantilever-free scanning probe lithography (SPL) employs soft elastomeric pen arrays to deliver material or energy to a surface to achieve a high-resolution, high-throughput, and low-cost nanopatterning. In particular, microscale elastomeric pyramid pen arrays are often adopted as the cantilever-free architecture owing to their distinct structural and mechanical properties. To better understand the mechanical behavior of the elastomeric pyramid pen array during the lithographic printing process, we numerically investigate the compression of an elastomeric pyramid array in a nonadhesive and frictionless contact with a rigid substrate. Simple scaling laws of the width of the contact surface with respect to the compression displacement and force are found and compared with previous models and experiments. By changing the interpyramid distance or the thickness of the base of the pyramid array, increasing deviations from the established scaling laws are observed and explained. Finally, we demonstrate that the unique morphology of a compressed pyramid primarily determines the unusual shape of the features fabricated by a specific cantilever-free SPL technique.

36 MATERIALS SCIENCE↗

Endovascular Treatment in Emergency Setting of Acute Arterial Injuries After Orthopedic Surgery

Purpose: To assess the feasibility and effectiveness of emergency endovascular treatment of acute arterial injuries after orthopedic surgery. Materials and Methods: Fifteen patients (mean age 68.3 years) with acute arterial injuries after orthopedic surgery were observed, in particular, 5 patients with pseudoaneurysm, 9 patients with active bleeding, and 1 patient with arterial dissection. Transarterial embolization (TAE) and positioning of covered and noncovered stents were the treatments performed. Follow-up after stent implantation (mean 36 months) was performed with color Doppler US (CDU) at 1, 3, 6, and 12 months and yearly thereafter. Plain X-ray was performed to evidence dislodgment or fracture of the graft. A minimum of 12 months' follow-up is available after TAE. Results: Immediate technical success was obtained in all cases. No major complications occurred. Overall clinical success rate was 100%. During mean follow-up, stent-graft occlusions did not occurred. No recurrence and/or consequence of TAE was registered during a minimum follow-up of 12 months. Conclusions: Percutaneous treatment is a feasible and safe tool for treating arterial injuries because it can provide fast and definitive resolution of the damage. This low-invasiveness approach can be proposed as first-line treatment in patients with acute injuries after orthopedic surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mesodynamics in the SARS nucleocapsid measured by NMR field cycling

Protein motions on all timescales faster than molecular tumbling are encoded in the spectral density. The dissection of complex protein dynamics is typically performed using relaxation rates determined at high and ultrahigh field. Here we expand this range of the spectral density to low fields through field cycling using the nucleocapsid protein of the SARS coronavirus as a model system. The field-cycling approach enables site-specific measurements of R1 at low fields with the sensitivity and resolution of a high-field magnet. These data, together with high-field relaxation and heteronuclear NOE, provide evidence for correlated rigid-body motions of the entire b-hairpin, and corresponding motions of adjacent loops with a time constant of 0.8 ns (mesodynamics). MD simulations substantiate these findings and provide direct verification of the time scale and collective nature of these motions.

59 BASIC BIOLOGICAL SCIENCES↗

Studies on the growth, structural, optical, mechanical properties of 8-hydroxyquinoline single crystal by vertical Bridgman technique

Highlights: {yields} Growth of bulk single crystal of 8-hydroxyquinoline (8-HQ) by vertical Bridgman technique for the first time. {yields} The crystalline perfection is reasonably good. {yields} The photoluminescence spectrum shows that the material is suitable for blue light emission. -- Abstract: Single crystal of organic nonlinear optical material, 8-hydroxyquinoline (8-HQ) of dimension 52 mm (length) x 12 mm (dia.) was grown from melt using vertical Bridgman technique. The crystal system of the material was confirmed by powder X-ray diffraction analysis. The crystalline perfection of the grown crystal was examined by high-resolution X-ray diffraction study. Low angular spread around 400'' of the diffraction curve and the low full width half maximum values show that the crystalline perfection is reasonably good. The recorded photoluminescence spectrum shows that the material is suitable for blue light emission. Optical transmittance for the UV and visible region was measured and mechanical strength was estimated from Vicker's microhardness test along the growth face of the grown crystal.

36 MATERIALS SCIENCE↗

Characterization of high purity germanium point contact detectors with low net impurity concentration

High Purity germanium point-contact detectors have low energy thresholds and excellent energy resolution over a wide energy range, and are thus widely used in nuclear and particle physics. In rare event searches, such as neutrinoless double beta decay, the point-contact geometry is of particular importance since it allows for pulse-shape discrimination, and therefore for a significant background reduction. In this paper we investigate the pulse-shape discrimination performance of ultra-high purity germanium point contact detectors. It is demonstrated that a minimal net impurity concentration is required to meet the pulse-shape performance requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Ablation-Aerosol Mass Spectrometry-Chemical Ionization Mass Spectrometry for Ambient Surface Imaging

Mass spectrometry imaging is becoming an increasingly common analytical technique due to its ability to provide spatially resolved chemical information. In this paper, we report a novel imaging approach combining laser ablation with two mass spectrometric techniques, aerosol mass spectrometry and chemical ionization mass spectrometry, separately and in parallel. Both mass spectrometric methods provide the fast response, rapid data acquisition, low detection limits, and high-resolution peak separation desirable for imaging complex samples. Additionally, the two techniques provide complementary information with aerosol mass spectrometry providing near universal detection of all aerosol molecules and chemical ionization mass spectrometry with a heated inlet providing molecular-level detail of both gases and aerosols. The two techniques operate with atmospheric pressure interfaces and require no matrix addition for ionization, allowing for samples to be investigated in their native state under ambient pressure conditions. We demonstrate the ability of laser ablation-aerosol mass spectrometry-chemical ionization mass spectrometry (LA-AMS-CIMS) to create 2D images of both standard compounds and complex mixtures. Finally, the results suggest that LA-AMS-CIMS, particularly when combined with advanced data analysis methods, could have broad applications in mass spectrometry imaging applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultranarrow TaS 2 Nanoribbons

Imposing additional confinement in two-dimensional (2D) materials can yield further control over the associated electronic, optical, and topological properties. However, synthesis of ultra-narrow nanoribbons (NRs) remains a challenge, particularly for the transition metal dichalcogenides (TMDs), and synthesizing TMD NRs narrower than 50 nm has remained elusive. In this paper, we report the vapor-phase synthesis of ultra-narrow TaS 2 NRs. The NRs are grown within the hollow cavity of carbon nanotubes, thereby limiting their lateral dimensions and layer number, while simultaneously stabilizing them against the environment. The NRs reach the monolayer (ML) limit and exhibit widths as low as 2.5 nm. Atomic-resolution scanning transmission electron microscopy (STEM) reveals the detailed atomic structure of the ultra-narrow NRs and we observe a hitherto unseen atomic structure supermodulation phenomenon of ordered defect arrays within the NRs. First-principles calculations based on density functional theory (DFT) show the presence of flat bands, as well as edge- and boundary-localized states, and help identify the atomic configuration of the supermodulation. Nanotube-templated synthesis represents a unique, transferable, and broadly deployable route toward ultra-narrow TMD NR growth.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Quantifying the Impact of Metal Population Distribution in MFI-Supported Mo Catalysts for Methane Dehydroaromatization

Precise evaluation of intrinsic kinetic behavior in Mo/MFI catalysts for methane dehydroaromatization (MDA) is confounded by variations in Mo dispersion and speciation, which are influenced by metal loading and zeolite acidity. This work advances the utility of H 2 -temperature programmed reduction (H 2 -TPR) for characterizing Mo/MFI catalysts by enabling quantitative comparison of MoO x populations distinguished by reduction behavior and linked to initial catalytic performance. A comprehensive H 2 reduction pathway is established through systematic H 2 - TPR studies varying catalyst composition (1–10 wt % Mo, Si/Al = 15, 40, ∞), supplemented by UV-Raman spectroscopy, X-ray powder diffraction, N 2 physisorption, NH 3 -TPD, and advanced spectroscopic analysis (in situ XAS with principal component analysis/multivariate curve resolution—alternating least squares). Two low-temperature H 2 -TPR regions capture distinct Mo populations undergoing initial Mo(VI)→Mo(IV) reduction: a lower-temperature population (Mo-RI) associated primarily with highly dispersed, anchored MoO x species expected to predominantly reside within MFI channels, and a higher-temperature population (Mo-RII) corresponding to a broader set of MoO x species that becomes increasingly bulk-like/extrazeolitic at higher Mo loading. Quantification of these populations provides practical, kinetically relevant descriptors for comparing initial MDA rates across catalysts with varying Mo loading, Si/Al ratio, and MoO x heterogeneity. Application of lower-temperature Mo-RI estimates to kinetic measurements reveals a minimum threshold of ∼0.12 × 10 –3 mol Mo-RI/g cat , above which initial forward benzene rates normalized to this population converge despite differences in metal loading and zeolite Brønsted acidity. This threshold coincides with a transition toward a common C 2 -mediated benzene-forming regime, as indicated by approach-to-equilibrium analysis of methane-to-ethane, ethane-to-ethylene, and ethylene-to-benzene reaction steps. Above this threshold, normalized initial benzene rates are nearly invariant with increasing Mo-RII/Mo-RI population ratio, indicating that excess Mo-RII populations, including bulk-like/extrazeolitic MoO x domains present at higher loading, do not measurably suppress benzene formation associated with anchored and mostly channel-confined Mo population under the initial-rate conditions examined.

Mo/MFI↗