Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Isotopic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Sulfur isotopes from the Paleoproterozoic Francevillian Basin record multigenerational pyrite formation, not depositional conditions

Bulk-rock sulfur isotope data from pyrite in the ~2.1 billion-year sedimentary rocks of the Francevillian Basin, Gabon, have underpinned ideas about initial oxygenation of Earth’s surface environments and eukaryote evolution. In this paper, we show, using micro-scale analytical methods, that the bulk sulfur isotope record represents progressive diagenetic modification. Our findings indicate no significant change in microbial sulfur cycling processes and seawater sulfate composition throughout that initial phase of atmosphere-ocean oxygenation of Paleoproterozoic time. This offers an alternative view of Earth system evolution during the transition from an anoxic to an oxic state and highlights the need for a judicious reappraisal of conceptual models using sulfur isotope data as primary depositional signals linked to global-scale biogeochemical processes.

58 GEOSCIENCES↗

High resolution isotopic analysis of U-bearing particles via fusion of SIMS and EDS images

Image fusion of secondary ion mass spectrometry (SIMS) images and X-ray elemental maps from energy-dispersive spectroscopy (EDS) was performed to facilitate the isolation and re-analysis of isotopically unique U-bearing particles where the highest precision SIMS measurements are required. Image registration, image fusion and particle micromanipulation were performed on a subset of SIMS images obtained from a large area pre-screen of a particle distribution from a sample containing several certified reference materials (CRM) U129A, U015, U150, U500 and U850, as well as a standard reference material (SRM) 8704 (Buffalo River Sediment) to simulate particles collected on swipes during routine inspections of declared uranium enrichment facilities by the International Atomic Energy Agency (IAEA). In total, fourteen particles, ranging in size from 5 – 15 µm, were isolated and re-analyzed by SIMS in multi-collector mode identifying nine particles of CRM U129A, one of U150, one of U500 and three of U850. These identifications were made within a few percent errors from the National Institute of Standards and Technology (NIST) certified atom percent values for 234U, 235U and 238U for the corresponding CRMs. This work represents the first use of image fusion to enhance the accuracy and precision of isotope ratio measurements for isotopically unique U-bearing particles for nuclear safeguards applications. Implementation of image fusion is essential for the identification of particles of interests that fall below the spatial resolution of the SIMS images.

EDS↗

Characterization of extreme ultraviolet laser ablation mass spectrometry for actinide trace analysis and nanoscale isotopic imaging

The purpose of this research was to characterize Extreme Ultraviolet Time-of-Flight (EUV TOF) Laser Ablation Mass Spectrometry for high spatial resolution elemental and isotopic analysis. We compare EUV TOF results with Secondary Ionization Mass Spectrometry (SIMS) to orient the EUV TOF method within the overall field of analytical mass spectrometry. Using the well-characterized NIST 61x glasses, we show that the EUV ionization approach produces relatively few molecular ion interferences in comparison to TOF SIMS. We demonstrate that the ratio of element ion to element oxide ion is adjustable with EUV laser pulse energy and that the EUV TOF instrument has a sample utilization efficiency of 0.014%. The EUV TOF system also achieves a lateral resolution of 80 nm and we demonstrate this lateral resolution with isotopic imaging of closely spaced particles or uranium isotopic standard materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isotope-resolved atomic beam laser spectroscopy of natural uranium

Here, we present our results on the development of a technique for conducting laser absorption spectroscopy of uranium in a collimated atomic beam using a compact and potentially fieldable device. A solid natural uranium metal sample is vaporized in a modest vacuum of several mTorr via resistive heating of a tantalum foil micro-crucible. A temperature of over 2000 °C is reached by applying only 200 W of electrical power to the crucible. At this temperature, the vapor pressure of uranium is large enough to generate a stable atomic beam. A diode laser is tuned around the 861.031 nm uranium transition, which allows the observation of absorption bands from both the 238 U and 235 U isotopes. The isotopic composition of uranium Standard Reference Material 960 is obtained from the absorption signal, in excellent agreement with the nominal value. In conclusion, our approach can be readily applied to the isotopic analysis of other actinides, and it is expected to lead to the development of compact, fieldable instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An approach to separating Pu, U, and Ti from high-purity graphite for isotopic analysis by MC-ICP-MS

Information about elemental and isotopic systematics of ultra-trace level actinides (e.g. U and Pu) and main group elements (e.g. Ti) present within nuclear grade graphite is vital to the nuclear community for improved reactor operation and security. In support of this, extensive effort has been placed on improving analysis methods (i.e., inductively coupled plasma-mass spectrometry). However, significantly less effort has been devoted to the optimization of chemical separation methods. Within the separation community, commercially available Eichrom™ resins are often employed, as their elution characteristics for various elements have been well studied, but the direct optimization of actinides and trace metal separations from a single sample have not been widely investigated. Here, methods using various Eichrom pre-packed cartridges were explored to achieve separation of ultra-trace levels of U, Pu, and Ti from a variety of graphite samples. Once the validity of the combined separation scheme was established using certified reference materials, the method was applied to historic, unirradiated and irradiated, graphite samples. For all samples investigated, precise isotope ratio measurements for the titanium isotope systems were made.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Application of saturation absorption spectroscopy to study the hyperfine structure of 235U and accurate 235U/238U isotope ratio determinations at 861.031 nm

The uranium transition 5f 3 6d7s 2 ( 5 L 6 ) → 5f 3 7s 2 7p ( 5 K 5 ) at 861.031 nm was studied using saturation absorption spectroscopy. The hyperfine structure of the 235 U isotope was determined by measuring the Doppler-suppressed absorption spectrum, and the hyperfine structure constants were obtained by employing transition-specific line strength theory and spectral fitting. The magnetic-dipole and electric-quadrupole constants were determined to be A = -3.2887 ± 0.1957 mK and B = 31.8712 ± 8.0789 mK for the upper state 5f 3 7s 2 7p ( 5 K 5 ). A theoretical calculation for the hyperfine structure constants of the 235 U isotope was also carried out by the relativistic configuration-interaction (RCI) method, and the obtained values were found to be in agreement with the measured values. In addition, the line profile of 238 U was experimentally investigated for different excitation intensities and modeled using the RCI method for estimating the transition probability and oscillator strength, with various residual broadening mechanisms considered beyond the radiative decay. Finally, we show that these results allow us to make improvements on the precision of spectral measurements using our previously developed technique for isotope ratio determinations in atomic beams.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum dynamics of the temporary capture of light atoms by superfluid helium nanodroplets at very low collision energies (≈1–13 meV): the case of the hydrogen atom and its isotopes

The capture dynamics of a H atom and isotopic variants [D, T and Q (hypothetical isotope of mass equal to four times the mass of H)] by a superfluid helium nanodroplet (HeND) has been investigated theoretically. The HeND (T = 0.37 K) is ( 4 He) N=400 and a mean field quantum hybrid approach [TDDFT (helium) + quantum wave packet (H, D, T or Q)] at zero angular momentum, is used to explore a rather wide range of very low initial kinetic energies (E k,0 ≈ 10–150 K). The analysis of the capture mechanism shows the existence of a dynamical barrier and a dynamical minimum that play key roles to understand the time evolution of the capture, especially the former property. In general, the H atom shows a different behavior from the other isotopes, with the behavior of T and Q being very similar to each other and the D atom behaving inbetween H and T. Besides, it is worth noting that, in principle, at the very low initial kinetic energies considered only “short” and “long” lived atom⋯HeND collision complexes are formed, i.e., in the atom-helium nanodroplet collision only the temporary capture of the atom takes place. The different behaviors observed have been interpreted considering the faster motion of the H atom when colliding with ( 4 He) N=400 and the more quantum character of the H behavior both due to its significantly lower mass. As far as we know, this is the first quantum dynamics study carried out on the collision of light atoms with HeNDs at very low energies.

Sternberg, Michael [Argonne National Laboratory (A↗

Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)↗

Direct and rapid uranium isotopic analysis of environmental sample swipes via microextraction – LS-APGD/Orbitrap mass spectrometry

Accurate and precise isotopic analysis of actinides collected on environmental sample swipes from within nuclear facilities is an important safeguarding measure for detecting undeclared materials and activities. Traditional isotope ratio (IR) analysis of actinides using a bulk digestion approach can be laborious and time-consuming. Recently, direct analysis of environmental swipe samples using a microextraction approach has been explored as an alternative to conventional bulk digestion methods. The present study further evaluates this approach for accurate and precise isotopic analysis of uranium (U) in cotton swipe samples using the liquid sampling-atmospheric pressure glow discharge (LS-APGD)/Orbitrap-FTMS Booster detection system. The instrumental parameters were optimized, and quantitative capabilities were demonstrated through excellent linearity (R2 = 0.99) across a deposited mass range of 1 to 500 ng, with a limit of detection of 90 pg (in a 2 × 4 mm region) for total U; well below typical U concentrations (ng–mg range) in environmental sample swipes. The 235U/238U ratio showed excellent accuracy (−0.3% relative difference from the certificate value), with ∼20× improvement over previous microextraction-Orbitrap methods. Precision (∼1% relative standard deviation) was also greatly enhanced by ∼5×. This study also demonstrates that figures of merit achieved with neat U solution were not highly degraded when various external interfering elements/matrices were introduced. Finally, the developed method was successfully applied to analyze practical swipe samples representative of laboratory and outdoor environments. The presented figures of merit and applicability to practical samples further validate the capability of the platform for rapid analysis (<7 minutes) of environmental swipe samples.

Shrestha, Suraj [Clemson University, SC]↗

Ion-beam mixing in crystalline and amorphous germanium isotope multilayers

Gallium (Ga) implantation induced self-atom mixing in crystalline and amorphous germanium (Ge) is investigated utilizing isotopically controlled Ge multilayer structures grown by molecular beam epitaxy. The distribution of the Ga ions and the ion-beam induced depth-dependent mixing of the isotope structure was determined by means of secondary ion mass spectrometry. Whereas the distribution of Ga in the crystalline and amorphous Ge is very similar and accurately reproduced by computer simulations based on binary collision approximation (BCA), the ion-beam induced self-atom mixing is found to depend strongly on the state of the Ge structure. The experiments reveal stronger self-atom mixing in crystalline than in amorphous Ge. Atomistic simulations based on BCA reproduce the experimental results only when unphysically low Ge displacement energies are assumed. Analysis of the self-atom mixing induced by silicon implantation confirms the low displacement energy deduced within the BCA approach. This demonstrates that thermal spike mixing contributes significantly to the overall mixing of the Ge isotope structures. The disparity observed in the ion-beam mixing efficiency of crystalline and amorphous Ge indicates different dominant mixing mechanisms. We propose that self-atom mixing in crystalline Ge is mainly controlled by radiation enhanced diffusion during the early stage of mixing before the crystalline structure turns amorphous, whereas in an already amorphous state self-atom mixing is mediated by cooperative diffusion events.

36 MATERIALS SCIENCE↗

Nondestructive identification of isotopes using nuclear resonance fluorescence

Nondestructive identification of heavy isotopes concealed in a thick iron box has been demonstrated by using nuclear resonance fluorescence. A quasi-monochromatic photon beam produced by the collision of laser quanta with high energy electrons was used for resonant excitation of nuclear levels in {sup 206}Pb and {sup 208}Pb. By measuring the resonant {gamma} rays emitted from {sup 206}Pb and {sup 208}Pb, each of these isotopes were clearly identified. The ratio of the effective thickness, i.e., concentration distribution, of these isotopes was deduced from the relative intensities of the measured nuclear resonance fluorescence strengths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic-scale characterization of germanium isotopic multilayers by atom probe tomography

We report comparison of the interfacial sharpness characterization of germanium (Ge) isotopic multilayers between laser-assisted atom probe tomography (APT) and secondary ion mass spectrometry (SIMS). An alternating stack of 8-nm-thick naturally available Ge layers and 8-nm-thick isotopically enriched {sup 70}Ge layers was prepared on a Ge(100) substrate by molecular beam epitaxy. The APT mass spectra consist of clearly resolved peaks of five stable Ge isotopes ({sup 70}Ge, {sup 72}Ge, {sup 73}Ge, {sup 74}Ge, and {sup 76}Ge). The degree of intermixing at the interfaces between adjacent layers was determined by APT to be around 0.8 {+-} 0.1 nm which was much sharper than that obtained by SIMS.

36 MATERIALS SCIENCE↗

Resonance ionization laser ion sources for on-line isotope separators (invited)

A Resonance Ionization Laser Ion Source (RILIS) is today considered an essential component of the majority of Isotope Separator On Line (ISOL) facilities; there are seven laser ion sources currently operational at ISOL facilities worldwide and several more are under development. The ionization mechanism is a highly element selective multi-step resonance photo-absorption process that requires a specifically tailored laser configuration for each chemical element. For some isotopes, isomer selective ionization may even be achieved by exploiting the differences in hyperfine structures of an atomic transition for different nuclear spin states. For many radioactive ion beam experiments, laser resonance ionization is the only means of achieving an acceptable level of beam purity without compromising isotope yield. Furthermore, by performing element selection at the location of the ion source, the propagation of unwanted radioactivity downstream of the target assembly is reduced. Whilst advances in laser technology have improved the performance and reliability of laser ion sources and broadened the range of suitable commercially available laser systems, many recent developments have focused rather on the laser/atom interaction region in the quest for increased selectivity and/or improved spectral resolution. Much of the progress in this area has been achieved by decoupling the laser ionization from competing ionization processes through the use of a laser/atom interaction region that is physically separated from the target chamber. A new application of gas catcher laser ion source technology promises to expand the capabilities of projectile fragmentation facilities through the conversion of otherwise discarded reaction fragments into high-purity low-energy ion beams. A summary of recent RILIS developments and the current status of laser ion sources worldwide is presented.

43 PARTICLE ACCELERATORS↗

Communication: Ab initio simulations of hydrogen-bonded ferroelectrics: Collective tunneling and the origin of geometrical isotope effects

Ab initio simulations that account for nuclear quantum effects have been used to examine the order-disorder transition in squaric acid, a prototypical H-bonded antiferroelectric crystal. Our simulations reproduce the >100 K difference in transition temperature observed upon deuteration as well as the strong geometrical isotope effect observed on intermolecular separations within the crystal. We find that collective transfer of protons along the H-bonding chains – facilitated by quantum mechanical tunneling – is critical to the order-disorder transition and the geometrical isotope effect. This sheds light on the origin of isotope effects and the importance of tunneling in squaric acid which likely extends to other H-bonded ferroelectrics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved repetition rate mixed isotope CO{sub 2} TEA laser

A compact CO{sub 2} TEA laser has been developed for remote chemical detection that operates at a repetition rate of 250 Hz. It emits 700 mJ/pulse at 10.6 μm in a multimode beam with the {sup 12}C{sup 16}O{sub 2} isotope. With mixed {sup 12}C{sup 16}O{sub 2} plus {sup 13}C{sup 16}O{sub 2} isotopes it emits multiple lines in both isotope manifolds to improve detection of a broad range of chemicals. In particular, output pulse energies are 110 mJ/pulse at 9.77 μm, 250 mJ/pulse at 10 μm, and 550 mJ/pulse at 11.15 μm, useful for detection of the chemical agents Sarin, Tabun, and VX. Related work shows capability for long term sealed operation with a catalyst and an agile tuner at a wavelength shift rate of 200 Hz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theory of the Helium Isotope Shift

Theory of the isotope shift of the centroid energies of light few-electron atoms is reviewed. Numerical results are presented for the isotope shift of the 2{sup 3}P-2{sup 3}S and 2{sup 1}S-2{sup 3}S transition energies of {sup 3}He and {sup 4}He. By comparing theoretical predictions for the isotope shift with the experimental results, the difference of the squares of the nuclear charge radii of {sup 3}He and {sup 4}He, δR{sup 2}, is determined with high accuracy.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nitrogen use efficiency evaluation of aerobic rice under field capacity water potential using {sup 15}N isotopic tracer technique

This study was carried out to evaluate the efficiency use of the nitrogen fertilizer on aerobic rice varieties MR219-4 and MR219-9 which were grown aerobically under field capacity water potential at the controlled environment area or shield house. Direct {sup 15}N isotope tracer method was used in this study, whereby the {sup 15}N isotope was utilized as a tracer for nitrogen nutrient uptake. {sup 15}N isotope presence in the samples is determined by using emission spectrometer analysis and percentage of total nitrogen is determined by using Kjeldahl method. {sup 15}N atom access value contained in the sample will be used in determining the effectiveness of the use of nitrogen in fertilizers through the specific calculation formulas. In this work, the data several data of nitrogen derived from fertilizer (Ndff), total nitrogen, nitrogen uptake and nitrogen use efficiency was obtained.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Several levels of theory for description of isotope effects in ozone: Effect of resonance lifetimes and channel couplings

In this study, two levels of theory are developed to determine the role of scattering resonances in the process of ozone formation. At the lower theory level, we compute resonance lifetimes in the simplest possible way, by neglecting all couplings between the diabatic vibrational channels in the problem. This permits to determine the effect of “shape” resonances, trapped behind the centrifugal barrier and populated by quantum tunneling. At the next level of theory, we include couplings between the vibrational channels, which permits to determine the role of Feshbach resonances and interaction of different reaction pathways on the global PES of ozone. Pure shape resonances are found to contribute little to the overall recombination process since they occur rather infrequently in the spectrum, in the vicinity of the top of the centrifugal barrier only. Moreover, the associated isotope effects are found to disagree with experimental data. By contrast, Feshbach-type resonances are found to make dominant contribution to the process. They occur in a broader range of spectrum, and their density of states is much higher. The properties of Feshbach resonances are studied in detail. They explain the isotopic ζ-effect, giving theoretical prediction in good agreement with experiments for both singly and doubly substituted ozone molecules. Importantly, Feshbach resonances also contribute to the isotopic η-effect, moving theoretical predictions in the right direction. Some differences with experimental data remain, which indicates that there may be another additional source of the η-effect.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗