Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Dosimetric perturbations due to an implanted cardiac pacemaker in MammoSite{sup Registered-Sign} treatment

Purpose: To investigate dose perturbations for pacemaker-implanted patients in partial breast irradiation using high dose rate (HDR) balloon brachytherapy. Methods: Monte Carlo (MC) simulations were performed to calculate dose distributions involving a pacemaker in Ir-192 HDR balloon brachytherapy. Dose perturbations by varying balloon-to-pacemaker distances (BPD = 50 or 100 mm) and concentrations of iodine contrast medium (2.5%, 5.0%, 7.5%, and 10.0% by volume) in the balloon were investigated for separate parts of the pacemaker (i.e., battery and substrate). Relative measurements using an ion-chamber were also performed to confirm MC results. Results: The MC and measured results in homogeneous media without a pacemaker agreed with published data within 2% from the balloon surface to 100 mm BPD. Further their dose distributions with a pacemaker were in a comparable agreement. The MC results showed that doses over the battery were increased by a factor of 3, compared to doses without a pacemaker. However, there was no significant dose perturbation in the middle of substrate but up to 70% dose increase in the substrate interface with the titanium capsule. The attenuation by iodine contrast medium lessened doses delivered to the pacemaker by up to 9%. Conclusions: Due to inhomogeneity of pacemaker and contrast medium as well as low-energy photons in Ir-192 HDR balloon brachytherapy, the actual dose received in a pacemaker is different from the homogeneous medium-based dose and the external beam-based dose. Therefore, the dose perturbations should be considered for pacemaker-implanted patients when evaluating a safe clinical distance between the balloon and pacemaker.

60 APPLIED LIFE SCIENCES↗

Search for α decay of Te 104 with a novel recoil-decay scintillation detector

A search for superallowed α decay of N = Z nuclei Te 104 and Xe 108 was carried out using a novel recoil-decay scintillator detector at the tandem accelerator facility at the Japan Atomic Energy Agency (JAEA). In this study, inorganic crystal scintillation material YAP:Ce (yttrium aluminum perovskite) coupled to a position-sensitive photomultiplier tube (PSPMT) was implemented for the first time in a radioactive decay experiment. Residues from the fusion-evaporation reaction Ni 58 + Fe 54 → Xe * 112 were separated by the JAEA Recoil Mass Separator (RMS) and implanted into the YAP:Ce crystal. α decays of neutron-deficient tellurium isotopes were identified and proton emission of I 109 was observed. The α -decay chain Xe 109 → Te 105 → Sn 101 was recorded with a time interval of 960 ns between two α pulses. Position localization in the crystal for decays and ions in the energy range from hundreds of keV to 60 MeV was achieved with an accuracy of 0.67 mm, proving that this detector is capable of making temporal and spatial correlations for fast decay events. No conclusive evidence was found for the decay chain Xe 108 → Te 104 → Sn 100 within 3 days of experiment. However, two events were observed with properties consistent with the reported observation at the Fragment Mass Analyzer (FMA), but with a separation between signals of less than 4 ns. The cross section limit of 130 pb was obtained for production of two events of Xe 108 , about an order of magnitude below the expectation based on earlier cross section measurements and the HIVAP fusion-evaporation code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mechanism of Inactivation of Ornithine Aminotransferase by (1S,3S)-3-Amino-4-(hexafluoropropan-2-ylidenyl)cyclopentane-1-carboxylic Acid

The inhibition of ornithine aminotransferase (OAT), a pyridoxal 5'-phosphate-dependent enzyme, has been implicated as a treatment for hepatocellular carcinoma (HCC), the most common form of liver cancer, for which there is no effective treatment. From a previous evaluation of our aminotransferase inhibitors, (1S,3S)-3-amino-4-(perfluoropropan-2-ylidene)cyclopentane-1-carboxylic acid hydrochloride (1) was found to be a selective and potent inactivator of human OAT (hOAT), which inhibited the growth of HCC in athymic mice implanted with human-derived HCC, even at a dose of 0.1 mg/kg. Currently, investigational new drug (IND)-enabling studies with 1 are underway. The inactivation mechanism of 1, however, has proved to be elusive. In this work we propose three possible mechanisms, based on mechanisms of known aminotransferase inactivators: Michael addition, enamine addition, and fluoride ion elimination followed by conjugate addition. On the basis of crystallography and intact protein mass spectrometry, it was determined that 1 inactivates hOAT through fluoride ion elimination to an activated 1,1'-difluoroolefin, followed by conjugate addition and hydrolysis. This result was confirmed with additional studies, including the detection of the cofactor structure by mass spectrometry and through the identification of turnover metabolites. On the basis of this inactivation mechanism and to provide further evidence for the mechanism, analogues of 1 (19, 20) were designed, synthesized, and demonstrated to have the predicted selective inactivation mechanism. These analogues highlight the importance of the trifluoromethyl group and provide a basis for future inactivator design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reducing the uncertainties in particle therapy

The use of fundamental Nuclear Physics in Nuclear Medicine has a significant impact in the fight against cancer. Hadrontherapy is an innovative cancer radiotherapy method using nuclear particles (protons, neutrons and ions) for the treatment of early and advanced tumors. The main goal of proton therapy is to deliver high radiation doses to the tumor volume with minimal damage to healthy tissues and organs. The purpose of this work was to investigate the dosimetric errors in clinical proton therapy dose calculation due to the presence of metallic implants in the treatment plan, and to determine the impact of the errors. The results indicate that the errors introduced by the treatment planning systems are higher than 10% in the prediction of the dose at isocenter when the proton beam is passing directly through a metallic titanium alloy implant. In conclusion, we recommend that pencil-beam algorithms not be used when planning treatment for patients with titanium alloy implants, and to consider implementing methods to mitigate the effects of the implants.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A versatile apparatus for on-line emission channeling experiments

The concept and functionality of an apparatus dedicated to emission channeling experiments using short-lived isotopes on-line at ISOLDE/CERN is described. The setup is assembled in two functional blocks – (a) base stand including beam collimation, implantation and measurement chamber, cryogenic extension, and vacuum control system and (b) Panmure goniometer extension including maneuvering cradle and sample heating furnace. This setup allows for in situ implantation and sample analysis in the as-implanted state and upon cooling down to 50 K and during annealing up to 1200 K. The functionality of the setup will be illustrated with the example of establishing the lattice location of {sup 56}Mn probes implanted into GaAs.

43 PARTICLE ACCELERATORS↗

Combination of imaging mass spectrometry and electron microscopy for quasi nondestructive surface analysis

We report on a combination of imaging mass spectrometry (MS) and scanning electron microscopy (SEM) developed in a custom designed time-of-flight (TOF) MS instrument with laser post-ionization of sputtered atoms. Elemental (by MS) and topographical (by SEM) mapping of surfaces of heavily contaminated Si collectors from the NASA Genesis sample return mission enabled obtaining much more accurate and detailed depth distribution of the Solar Wind Mg and Ca implanted in these collectors. This is because the cleanest areas were identified by the SEM/MS mapping, and high resolution sputter depth profiling at these locations revealed near-surface (0-15 nm) depth distribution of Mg and Ca, that were used for more accurate fluence calculations of these Solar Wind species. MS imaging was virtually nondestructive at primary ion fluence 10(12) cm(-2), causing no effect on accuracy and precision of quantitative depth profiling that followed the imaging. We also demonstrate importance of such an approach by directly comparing high resolution depth profiles measured on clean areas versus arbitrarily selected areas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent control and high-fidelity readout of chromium ions in commercial silicon carbide

Abstract Transition metal ions provide a rich set of optically active defect spins in wide bandgap semiconductors. Chromium (Cr 4+ ) in silicon-carbide (SiC) produces a spin-1 ground state with a narrow, spectrally isolated, spin-selective, near-telecom optical interface. However, previous studies were hindered by material quality resulting in limited coherent control. In this work, we implant Cr into commercial 4H-SiC and show optimal defect activation after annealing above 1600 °C. We measure an ensemble optical hole linewidth of 31 MHz, an order of magnitude improvement compared to as-grown samples. An in-depth exploration of optical and spin dynamics reveals efficient spin polarization, coherent control, and readout with high fidelity (79%). We report T 1 times greater than 1 s at cryogenic temperatures (15 K) with a T 2 * = 317 ns and a T 2 = 81 μs, where spin dephasing times are currently limited by spin–spin interactions within the defect ensemble. Our results demonstrate the potential of Cr 4+ in SiC as an extrinsic, optically active spin qubit.

74 ATOMIC AND MOLECULAR PHYSICS↗

TU-F-CAMPUS-T-04: An Evaluation of Out-Of-Field Doses for Electron Beams From Modern Varian and Elekta Linear Accelerators

Purpose: Accurately determining out-of-field doses when using electron beam radiotherapy is of importance when treating pregnant patients or patients with implanted electronic devices. Scattered doses outside of the applicator field in electron beams have not been broadly investigated, especially since manufacturers have taken different approaches in applicator designs. Methods: In this study, doses outside of the applicator field were measured for electron beams produced by a 10×10 applicator on two Varian 21iXs operating at 6, 9, 12, 16, and 20 MeV, a Varian TrueBeam operating at 6, 9, 12, 16, and 20 MeV, and an Elekta Versa HD operating at 6, 9, 12 and 15 MeV. Peripheral dose profiles and percent depth doses were measured in a Wellhofer water phantom at 100 cm SSD with a Farmer ion chamber. Doses were compared to peripheral photon doses from AAPM’s Task Group #36 report. Results: Doses were highest for the highest electron energies. Doses typically decreased with increasing distance from the field edge but showed substantial increases over some distance ranges. Substantial dose differences were observed between different accelerators; the Elekta accelerator had much higher doses than any Varian unit examined. Surprisingly, doses were often similar to, and could be much higher than, doses from photon therapy. Doses decreased sharply with depth before becoming nearly constant; the dose was found to decrease to a depth of approximately E(MeV)/4 in cm. Conclusion: The results of this study indicate that proper shielding may be very important when utilizing electron beams, particularly on a Versa HD, while treating pregnant patients or those with implanted electronic devices. Applying a water equivalent bolus of Emax(MeV)/4 thickness (cm) on the patient would reduce fetal dose drastically for all clinical energies and is a practical solution to manage the potentially high peripheral doses seen from modern electron beams. Funding from NIH Grant number: #CA180803.

60 APPLIED LIFE SCIENCES↗

Poly(vinyl alcohol) Hydrogels with Broad-Range Tunable Mechanical Properties via the Hofmeister Effect

Hydrogels, exhibiting wide applications in soft robotics, tissue engineering, implantable electronics, etc., often require sophisticately tailoring of the hydrogel mechanical properties to meet specific demands. For examples, soft robotics necessitates tough hydrogels; stem cell culturing demands various tissue-matching modulus; and neuron probes desire dynamically tunable modulus. Herein, a strategy to broadly alter the mechanical properties of hydrogels reversibly via tuning the aggregation states of the polymer chains by ions based on the Hofmeister effect is reported. An ultratough poly(vinyl alcohol) (PVA) hydrogel as an exemplary material (toughness 150 ± 20 MJ m -3 ), which surpasses synthetic polymers like poly(dimethylsiloxane), synthetic rubber, and natural spider silk is fabricated. With various ions, the hydrogel's various mechanical properties are continuously and reversibly in situ modulated over a large window: tensile strength from 50 ± 9 kPa to 15 ± 1 MPa, toughness from 0.0167 ± 0.003 to 150 ± 20 MJ m -3 , elongation from 300 ± 100% to 2100 ± 300%, and modulus from 24 ± 2 to 2500 ± 140 kPa. Importantly, the ions serve as gelation triggers and property modulators only, not necessarily required to remain in the gel, maintaining the high biocompatibility of PVA without excess ions. Overall, this strategy, enabling high mechanical performance and broad dynamic tunability, presents a universal platform for broad applications from biomedicine to wearable electronics.

36 MATERIALS SCIENCE↗

Exploring the effect of ELM and code-coupling frequencies on plasma and material modeling of dynamic recycling in divertors

Abstract Integrated modeling of plasma-surface interactions provides a comprehensive and self-consistent description of the system, moving the field closer to developing predictive and design capabilities for plasma facing components. One such workflow, including descriptions for the scrape-off-layer plasma, ion-surface interactions and the sub-surface evolution, was previously used to address steady-state scenarios and has recently been extended to incorporate time-dependence and two-way information flow. The new model can address dynamic recycling in transient scenarios, such as the application presented in this paper: the evolution of W samples pre-damaged by helium and exposed to ELMy H-mode plasmas in the DIII-D DiMES. A first set of simulations explored the effect of ELM frequency. This study was discussed in detail in this conference’s proceedings and is summarized here. The 2nd set of simulations, which is the focus of this paper, explores the effect of code-coupling frequency. These simulations include initial SOLPS solutions converged to the inter-ELM state, ion impact energy ( E in ) and angles ( A in ) calculated by hPIC2, and an improved heat transfer description in Xolotl. The model predicts increases in particle fluxes and decreases in heat fluxes by 10%–20% with the coupling time-step. Compared with the first set of simulations, the less shallow impact angle leads to smaller reflection rates and significant D implantation. The higher fraction of implanted flux (and deeper), in particular during ELMs, increases the accumulated D content in the W near-surface region. Future expansion of the workflow includes coupling to hPIC2 and GITR to ensure accurate descriptions of E in and A in , and W impurity transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Atmospheres of the Moon and Mercury

Mercury and the Moon have long been considered to be similar objects, but this view was based on limited information at visible wavelengths. It is now known that real differences exist in the atmospheres and in the rock types as deduced from mid-infrared observations. Lunar Ar and perhaps Ne were observed from Apollo landed experiments in spite of a large local background. An ultraviolet spectrometer (UVS) in orbit placed upper limits on a number of gases including H and O. At Mercury, the UVS on Mariner 10 measured H, He, and perhaps O and again a number of upper limits for other gases. Less than a decade ago, emissions of Na and K were observed from the ground, with abundances 2 orders of magnitude smaller on the Moon than on Mercury. It is likely that impacting meteoroids bring a significant amount of water to Mercury, whose atmosphere should therefore contain water vapor. This notion is supported by the recent discovery of radar-bright polar deposits almost certainly composed of ice. A variety of origins is likely for the different components. Impact of meteoroids could supply water, Na, and K, and could also vaporize surface material; Na, K, and Ar could be degassed from the crust. H is probably from the solar wind, and He could reasonably come from degassing or the solar wind. A substantial loss process for all components is photoionization (or dissociation); ions on one side are swept away into the solar wind and on the other are swept back to the surface. This process is complicated at Mercury by its permanent magnetic field, but there is little doubt that both loss and recycling still occur. Some of the recycling probably occurs by way of the magnetotail through night side auroral precipitation; atoms implanted in the surface will diffuse back into the atmosphere shortly after dawn, an effect that seems to be present for K. Finally the light atoms H and He have high enough velocities to escape directly, an effect that may be enhanced by the suprathermal velocity distributions that are likely to be present.

Hunten, D. M.↗

The electroluminescence mechanism of Er³⁺ in different silicon oxide and silicon nitride environments

Rare earth doped metal-oxide-semiconductor (MOS) structures are of great interest for Si-based light emission. However, several physical limitations make it difficult to achieve the performance of light emitters based on compound semiconductors. To address this point, in this work the electroluminescence (EL) excitation and quenching mechanism of Er-implanted MOS structures with different designs of the dielectric stack are investigated. The devices usually consist of an injection layer made of SiO₂ and an Er-implanted layer made of SiO₂, Si-rich SiO₂, silicon nitride, or Si-rich silicon nitride. All structures implanted with Er show intense EL around 1540 nm with EL power efficiencies in the order of 2 × 10⁻³ (for SiO₂:Er) or 2 × 10⁻⁴(all other matrices) for lower current densities. The EL is excited by the impact of hot electrons with an excitation cross section in the range of 0.5–1.5 × 10⁻¹⁵cm⁻². Whereas the fraction of potentially excitable Er ions in SiO₂ can reach values up to 50%, five times lower values were observed for other matrices. The decrease of the EL decay time for devices with Si-rich SiO₂ or Si nitride compared to SiO₂ as host matrix implies an increase of the number of defects adding additional non-radiative de-excitation paths for Er³⁺. For all investigated devices, EL quenching cross sections in the 10⁻²⁰ cm² range and charge-to-breakdown values in the range of 1–10 C cm⁻² were measured. For the present design with a SiO₂ acceleration layer, thickness reduction and the use of different host matrices did not improve the EL power efficiency or the operation lifetime, but strongly lowered the operation voltage needed to achieve intense EL.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exploring the Impact of Copper Oxide Substitution on Structure, Morphology, Bioactivity, and Electrical Properties of 45S5 Bioglass®

In recent decades, the requirements for implantable medical devices have increased, but the risks of implant rejection still exist. These issues are primarily associated with poor osseointegration, leading to biofilm formation on the implant surface. This study focuses on addressing these issues by developing a biomaterial for implant coatings. 45S5 bioglass® has been widely used in tissue engineering due to its ability to form a hydroxyapatite layer, ensuring a strong bond between the hard tissue and the bioglass. In this context, 45S5 bioglasses®, modified by the incorporation of different amounts of copper oxide, from 0 to 8 mol%, were synthesized by the melt–quenching technique. The incorporation of Cu ions did not show a significant change in the glass structure. Since the bioglass exhibited the capacity for being polarized, thereby promoting the osseointegration effectiveness, the electrical properties of the prepared samples were studied using the impedance spectroscopy method, in the frequency range of 102–106 Hz and temperature range of 200–400 K. The effects of CuO on charge transport mobility were investigated. Additionally, the bioactivity of the modified bioglasses was evaluated through immersion tests in simulated body fluid. The results revealed the initiation of a Ca–P-rich layer formation on the surface within 24 h, indicating the potential of the bioglasses to enhance the bone regeneration process.

Hammami, Imen (ORCID:0000000290072221)↗

High-Speed Tandem Mass Spectrometric in Situ Imaging by Nanospray Desorption Electrospray Ionization Mass Spectrometry

Nanospray desorption electrospray ionization (nano-DESI) combined with tandem mass spectrometry (MS/MS), high-resolution mass analysis (m/m=17,500 at m/z 200), and rapid spectral acquisition enabled simultaneous imaging and identification of more than 300 molecules from 92 selected m/z windows (± 1 Da) with a spatial resolution of better than 150 um. Uterine sections of implantation sites on day 6 of pregnancy were analyzed in the ambient environment without any sample pre-treatment. MS/MS imaging was performed by scanning the sample under the nano-DESI probe at 10 um/s while acquiring higher-energy collision-induced dissociation (HCD) spectra for a targeted inclusion list of 92 m/z values at a rate of ~6.3 spectra/s. Molecular ions and their corresponding fragments, separated using high-resolution mass analysis, were assigned based on accurate mass measurement. Using this approach, we were able to identify and image both abundant and low-abundance isobaric species within each m/z window. MS/MS analysis enabled efficient separation and identification of isobaric sodium and potassium adducts of phospholipids. Furthermore, we identified several metabolites associated with early pregnancy and obtained the first 2D images of these molecules.

Environmental Molecular Sciences Laboratory↗

Improving the laser performance of ion beam sputtered dielectric thin films through the suppression of nanoscale defects by employing a xenon sputtering gas

Laser damage-prone precursors in high index materials such as hafnia are believed to be the primary limiter in the performance of dielectric multilayer films to advance ultra-high power and energy laser applications. Removing or suppressing these precursors is the key to fabricating laser damage resistant thin films for the enabling technologies. Early work has revealed that nanobubbles formed by entrapped argon (Ar) working gas in ion beam sputtering (IBS) produced hafnia films are primarily responsible for the onset of laser damage upon exposure to UV, ns-laser pulses. In this study, we demonstrate that the UV ns-laser damage onset of IBS produced hafnia films can be improved to 3.1 +/- 0.2 J/cm 2 by substituting the conventional Ar working gas with xenon (Xe), a nearly 1 J/cm 2 increase from that of the Ar produced hafnia films. In addition to the suppression of the overall point-defect density of the hafnia films, the reduction of the Xe entrapment eliminates the nanobubbles and the generation of plasmas that initiates the laser damage. The defect suppression and its correlation to the increase in laser damage threshold is revealed by the combined analysis of Rutherford backscattering spectroscopy, electron paramagnetic resonance spectroscopy, transmission electron microscopy, and laser damage testing. Monte Carlo simulations suggest a much smaller entrapment of Xe gas by comparison to Ar, which is attributed to the significant difference in the energy of the reflected neutrals (3X) which are likely to be implanted. These results provide an effective process route with a fundamental understanding for producing high laser damage resistant dielectric films for high power and high energy laser applications.

36 MATERIALS SCIENCE↗

Nanoscale Compositional Mapping of Commercial LiNi 0.8 Co 0.15 Al 0.05 O 2 Cathodes Using Atom Probe Tomography

Nickel-rich cathodes provide improved specific capacity that lead to higher gravimetric energy density, critical for electric vehicles. However, poor long-term capacity retention at elevated temperatures/high C-rates (the rate of charge and discharge on a battery) stem from material issues: surface phase changes, corrosive side reactions with the electrolyte, ion dissolution and propagation of cracks. Introducing dopants, developing nanoscale surface coatings and graded core-shell structures have all improved the electrochemical performance of nickel-rich cathodes. However, a material level understanding on the effect of Li composition and distribution in Ni-rich cathodes is limited, due to a lack of characterization methods available that can directly image Li at the nanoscale. Hence, it is critical to establish methods such as atom probe tomography (APT), having both nanometer scale spatial resolution and high compositional sensitivity to quantitatively analyze battery cathodes. To fully realize its potential as a method for quantitative compositional analysis of commercial Li-ion batteries, we provide a comprehensive description of the challenges in sample preparation and analyze the dependency of the analysis parameters, specifically laser pulse energy on the measured stoichiometry of elements in a high Ni content cathode material; LiNi 0.8 Co 0.15 Al 0.05 O 2 (NCA). In this work, our findings show the stoichiometry variations cannot be explained by charge state ratios or Ga implantation damage alone during FIB preparation, indicating that additional factors such as crystallographic orientation may need to be considered to achieve quantitative nanoscale compositional analysis of such battery cathodes using APT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗