Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Flow velocity measurement with the nonlinear acoustic wave scattering

A problem of noninvasive measurement of liquid flow velocity arises in many practical applications. To this end the most often approach is the use of the linear Doppler technique. The Doppler frequency shift of signal scattered from the inhomogeneities distributed in a liquid relatively to the emitted frequency is proportional to the sound frequency and velocities of inhomogeneities. In the case of very slow flow one needs to use very high frequency sound. This approach fails in media with strong sound attenuation because acoustic wave attenuation increases with frequency and there is limit in increasing sound intensity, i.e. the cavitation threshold. Another approach which is considered in this paper is based on the method using the difference frequency Doppler Effect for flows with bubbles. This method is based on simultaneous action of two high-frequency primary acoustic waves with closed frequencies on bubbles and registration of the scattered by bubbles acoustic field at the difference frequency. The use of this method is interesting since the scattered difference frequency wave has much lower attenuation in a liquid. The theoretical consideration of the method is given in the paper. The experimental examples confirming the theoretical equations, as well as the ability of the method to be applied in medical diagnostics and in technical applications on measurement of flow velocities in liquids with strong sound attenuation is described. It is shown that the Doppler spectrum form depends on bubble concentration velocity distribution in the primary acoustic beams crossing zone that allows one to measure the flow velocity distribution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous parametric generation and up-conversion of entangled optical images

A quantum theory of parametric amplification and frequency conversion of an optical image in coupled nonlinear optical processes that include one parametric amplification process at high-frequency pumping and two up-conversion processes in the same pump field is developed. The field momentum operator that takes into account the diffraction and group velocities of the waves is used to derive the quantum equations related to the spatial dynamics of the images during the interaction. An optical scheme for the amplification and conversion of a close image is considered. The mean photon number density and signal-to-noise ratio are calculated in the fixed-pump-field approximation for images at various frequencies. It has been established that the signal-to-noise ratio decreases with increasing interaction length in the amplified image and increases in the images at the generated frequencies, tending to asymptotic values for all interacting waves. The variance of the difference of the numbers of photons is calculated for various pairs of frequencies. The quantum entanglement of the optical images formed in a high-frequency pump field is shown to be converted to higher frequencies during the generation of sum frequencies. Thus, two pairs of entangled optical images are produced in the process considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High power frequency comb based on mid-infrared quantum cascade laser at λ ∼ 9 μm

We investigate a frequency comb source based on a mid-infrared quantum cascade laser at λ ∼ 9 μm with high power output. A broad flat-top gain with near-zero group velocity dispersion has been engineered using a dual-core active region structure. This favors the locking of the dispersed Fabry-Pérot modes into equally spaced frequency lines via four wave mixing. A current range with a narrow intermode beating linewidth of 3 kHz is identified with a fast detector and spectrum analyzer. This range corresponds to a broad spectral coverage of 65 cm{sup −1} and a high power output of 180 mW for ∼176 comb modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Resolution Versus Error for Computational Electron Microscopy

Images that are collected via scanning transmission electron microscopy (STEM) can be undersampled to avoid damage to the specimen while maintaining resolution [1, 2]. We have used BPFA to impute missing data and reduce noise [3]. The reconstruction is typically evaluated using the peak signal-to-noise ratio (PSNR). This measure is too conservative for STEM images and we propose that the Fourier ring correlation (FRC) is used instead to evaluate the reconstruction. We are not concerned with exact reconstruction of the truth image, and therefore PSNR is a conservative estimation of the quality of the reconstruction. Instead, we are concerned with the visual resolution of the image and whether atoms can be distinguished. We have evaluated the reconstruction of a simulated STEM image using the FRC and compared the results with the PSNR measurements. The FRC captures the resolution of the image and is not affected by a large MSE if the atom peaks are still distinguishable. The noisy and reconstructed images are shown in Figure 1. The simulated STEM image was sampled at 100%, 80%, 40%, and 20% of the original pixels to simulate an undersampled scan. The reconstruction was done using BPFA with a patch size of 10 x 10 and no overlapping patches. Not having overlapping patches produces inferior results but they are still acceptable. The dictionary size is 64 and 30 iterations were completed during each reconstruction. The 100% image was denoised instead of reconstructed. Poisson noise was applied to the simulated image with λ values of 500, 50, and 5 to simulate lower imaging dose. The original simulated STEM image was also included in our calculations and was generated using a dose of 1000. The simulated STEM image is 100 by 100 pixels and has essentially no high frequency components. The image reconstruction tends to smooth the data, also resulting in no high frequency components. This causes the FRC of the two images to be large at higher resolutions and may be misleading. For this reason, the BPFA has no overlap to avoid excessive smoothing. Moreover, the resolution of the simulated image is approximately 9.2 (1/nm), so we only look that far in the frequency domain when performing FRC. If the FRC curve does not crossover the threshold, a resolution value of 9.2 is used. We emphasize that our reported results are conservative. The FRC and PSNR values using the ground truth and the reconstructed images are shown in Tables 1 and 2. The left side show the metrics without using BPFA (missing pixels) and the right side show the metrics after using BPFA. When we did not use BPFA, the Fourier transform was estimated [4]. Some threshold curves have been studied [5], but they are derived for additive noise models. Since we have a Poisson noise model, we have used the more conservative threshold of 0.5 for our calculations. Ten images were used to construct each cell of tables in the form of the mean of the metric plus or minus its standard deviation. As expected, the PSNR dies off much quicker than the FRC values for the same image. For the 100% and 80% sampled versions of the truth image, the resolution only dies off when the dose is 5. However, the PSNR dies off rapidly as the dose is reduced. For the 1000, 500, and 50 dose images, the FRC is the maximum, or close, until we undersample at 20%. The PSNR for these values tapers down as we get into the bottom right hand corner of the table, even though the resolution remains high. Overall, we find that undersampled images can be reconstructed to acceptable resolution even when the dose per pixel is also reduced[6]. References: [1]A Stevens, H Yang, L Carin et al. Microscopy 63(1), (2014), pp. 41. [2]A Stevens, L Kovarik, P Abellan et al. Advanced Structural and Chemical Imaging 1(1), (2015), pp. 1. [3]M Zhou, H Chen, J Paisley et al. Image Processing, IEEE Transactions on 21(1), (2012), pp. 130. [4]V. Y. Liepin’sh. Automatic control and computer sciences 30(3), (1996), pp. 20.

Luzi, Lorenzo↗

Modular power conversion system with galvanic insulation

A modular power conversion system is provided which includes a plurality of building blocks comprised of transformers and power conversion bridges, and a high frequency AC link that transfers power and provides galvanic isolation between the building blocks. The high frequency link includes an insulating tube separating an AC link conductor and the building blocks. The insulating tube is further provided with conductive or semiconductive layers on its inner and outer surfaces for referencing them to the electric potentials of the adjacent conductors and windings, thereby placing the high electric fields substantially directly across the tube and reducing electric fields and partial discharge or corona in the adjoining space or media. The building blocks may be arranged in multiple stacks for DC or AC interface, preferably with neutral or lower voltage connections at the outer edges of the stacks and higher voltage terminals at the centers of the stack.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The impact of hierarchically constrained dynamics with a finite mean of cluster sizes on relaxation properties

In this paper, a stochastic scenario of relaxation underlying the generalization (Kahlau et al., 2010) [15] of the Cole–Davidson (CD) and Kohlrausch–Williams–Watts (KWW) functions is proposed. As it has been shown (Kahlau et al., 2010) [15], the new three-parameter time-domain fitting function provides a very flexible description of the dielectric spectroscopy data for viscous glass-forming liquids. In relation to that result we discuss a hierarchically-constrained model yielding the proposed relaxation fitting function. Within the “exponentially decaying relaxation contributions” framework we show origins of the high-frequency (short-time, respectively) fractional power law, i.e., the characteristic feature of the new, as well as, of both CD and KWW response functions. We also bring into light a reason for which their common behavior in the opposite frequency limit is linear on external field frequency. Finally, we relate the new relaxation pattern (Kahlau et al., 2010) [15] with the Generalized Gamma (GG) survival probability of an imposed, non-equilibrium initial state in a relaxing system. -- Highlights: ► Combine the empirical Kohlrausch–Williams–Watts and Cole–Davidson laws of relaxation. ► Establish a microscopic stochastic scenario explaining the generalized law. ► Derive a frequency-domain relaxation function fitting the dielectric spectroscopy data. ► Find the low- and high-frequency properties for the relaxation pattern.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear excitation of zonal flows and streamers in plasmas

Nonlinear excitation of zonal flows and streamers in plasmas is considered. The emphasis is given to the nonlinear interaction of low- and high-frequency drift waves which can result in the excitation of zonal flows and streamers in a plasma of fusion devices. For this purpose, an inhomogeneous nonisothermal plasma in a strong external magnetic field whose characteristic frequencies are lower than the ion Langmuir frequency but higher than the collision frequency is studied. The excitation of a long-wavelength low-frequency drift wave during the development of the nonlinear modulational interaction of a high-frequency drift pump wave is investigated. The growth rates of the modulational instability are obtained, and the conditions for its development are determined. Self-organized structures described by solutions of evolutionary equations for the modulational interaction are associated with zonal flows and streamers. A possible relation of the modulational interaction in Earth's ionospheric plasma to the formation of dust flows and transport of dust particles in the ionosphere is also discussed. It is shown that one of the ways of transport of dust particles in the ionosphere is vertical flows (streamers), which are generated by dust vortices as a result of development of the modulational instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE HUNT FOR EXOMOONS WITH KEPLER (HEK). II. ANALYSIS OF SEVEN VIABLE SATELLITE-HOSTING PLANET CANDIDATES

From the list of 2321 transiting planet candidates announced by the Kepler Mission, we select seven targets with favorable properties for the capacity to dynamically maintain an exomoon and present a detectable signal. These seven candidates were identified through our automatic target selection (TSA) algorithm and target selection prioritization (TSP) filtering, whereby we excluded systems exhibiting significant time-correlated noise and focused on those with a single transiting planet candidate of radius less than 6 R{sub Circled-Plus }. We find no compelling evidence for an exomoon around any of the seven Kepler Objects of Interest (KOIs) but constrain the satellite-to-planet mass ratios for each. For four of the seven KOIs, we estimate a 95% upper quantile of M{sub S} /M{sub P} < 0.04, which given the radii of the candidates, likely probes down to sub-Earth masses. We also derive precise transit times and durations for each candidate and find no evidence for dynamical variations in any of the KOIs. With just a few systems analyzed thus far in the ongoing ''Hunt for Exomoons with Kepler'' (HEK) project, projections on eta-moon would be premature, but a high frequency of large moons around Super-Earths/Mini-Neptunes would be premature, but a high frequency of large moons around Super-Earths/Mini-Neptunes would appear to be incommensurable with our results so far.

79 ASTRONOMY AND ASTROPHYSICS↗

Varactor diodes for millimeter and submillimeter wavelengths

Whisker-contacted GaAs Schottky barrier varactor diodes are the most common high-frequency multiplier element in use today. They are inherently simple devices that have very high frequency response and have been used to supply local oscillator power for Schottky heterodyne receivers to frequencies approaching 700 GHz. This paper discusses the development of improved varactor diode technology for space based applications at millimeter and submillimeter wavelengths.

Rizzi, Brian J.↗

Flat microwave spectra seen at X-class flares

We report peculiar spectral activity of four large microwave bursts as obtained from the Solar Arrays at the Owens Valey Radio Observatory during observations of X-class flares on 24 May 1990 and 7, 8, 22 March 1991. Main observational points that we newly uncovered are: (1) flat flux spectra over 1-18 GHz in large amounts of flux ranging from 10(exp 2) to 10(exp 4) s.f.u. at the maximum phase, (2) a common evolutionary pattern in which the spectral region of dominant flux shifts from high frequencies at the initial rise to low frequencies at the decaying phase, and (3) unusual time profiles that are impulsive at high frequencies but more extended at lower frequencies. We carry out the model calculations of microwave spectra under assumptions of gyrosynchrotron mechanism and a dipole field configuration to reproduce the observational characteristics. Our results are summarized as follows. First, a flat microwave spectrum reaching up to 10(exp 2) - 10(exp 4) s.f.u. may occur in a case where a magnetic loop is extended to an angular size of approximately (0.7-7.0) x 10(exp -7) sterad and contains a huge number (N(E greater than 10 keV) approx. 10(exp 36) - 10(exp 38)) of nonthermal electrons with power-law index approx. 3-3.5 over the entire volume. Second, the observed spectral activity could adequately be accounted for by the shrinking of the region of nonthermal electrons to the loop top and by the softening of the power-law spectrum of electrons in a time scale ranging 3-45 min depending on the event. Third, the extended microwave activity at lower frequencies is probably due to electrons trapped in the loop top where magnetic fields are low. Finally, we clarify the physical distinction between these large, extended microwave bursts and the gradual/post-microwave bursts often seen in weak events, both of which are characterized by long-period activity and broadband spectra.

Lee, Jeongwoo W.↗

Measurements and Predictions of the Noise from Three-Stream Jets

An experimental and numerical investigation of the noise produced by high-subsonic and supersonic three-stream jets was conducted. The exhaust system consisted of externally-mixed-convergent nozzles and an external plug. Bypass- and tertiary-to-core area ratios between 1.0 and 2.5, and 0.4 and 1.0, respectively, were studied. Axisymmetric and offset tertiary nozzles were investigated for heated and unheated conditions. For axisymmetric configurations, the addition of the third stream was found to reduce peak- and high-frequency acoustic levels in the peak-jet-noise direction, with greater reductions at the lower bypass-to-core area ratios. For the offset configurations, an offset duct was found to decrease acoustic levels on the thick side of the tertiary nozzle relative to those produced by the simulated two-stream jet with up to 8 dB mid-frequency noise reduction at large angles to the jet inlet axis. Noise reduction in the peak-jet-noise direction was greater for supersonic core speeds than for subsonic core speeds. The addition of a tertiary nozzle insert used to divert the third-stream jet to one side of the nozzle system provided no noise reduction. Noise predictions are presented for selected cases using a method based on an acoustic analogy with mean flow interaction effects accounted for using a Green's function, computed in terms of its coupled azimuthal modes for the offset cases, and a source model previously used for round and rectangular jets. Comparisons of the prediction results with data show that the noise model predicts the observed increase in low-frequency noise with the introduction of a third, axisymmetric stream, but not the high-frequency reduction. For an offset third stream, the model predicts the observed trend of decreased sound levels on the thick side of the jet compared with the thin side, but the predicted azimuthal variations are much less than those seen in the data. Also, the shift of the spectral peak to lower frequencies with increasing polar angle is over-predicted. For an offset third stream with a heated core, it is shown that including the enthalpy-flux source terms in the acoustic analogy model improves predictions compared with those obtained using only the momentum flux.

Three-Stream Jets↗

Measurements and Predictions of the Noise from Three-Stream Jets

An experimental and numerical investigation of the noise produced by high-subsonic and supersonic three-stream jets was conducted. The exhaust system consisted of externally-mixed-convergent nozzles and an external plug. Bypass- and tertiary- to-core area ratios between 1.0 and 2.5, and 0.4 and 1.0, respectively, were studied. Axisymmetric and offset tertiary nozzles were investigated for heated and unheated conditions. For axisymmetric configurations, the addition of the third stream was found to reduce peak- and high-frequency acoustic levels in the peak-jet-noise direction, with greater reductions at the lower bypass-to-core area ratios. For the offset configurations, an offset duct was found to decrease acoustic levels on the thick side of the tertiary nozzle relative to those produced by the simulated two-stream jet with up to 8 dB mid-frequency noise reduction at large angles to the jet inlet axis. Noise reduction in the peak-jet-noise direction was greater for supersonic core speeds than for subsonic core speeds. The addition of a tertiary nozzle insert used to divert the third-stream jet to one side of the nozzle system provided no noise reduction. Noise predictions are presented for selected cases using a method based on an acoustic analogy with mean flow interaction effects accounted for using a Green's function, computed in terms of its coupled azimuthal modes for the offset cases, and a source model previously used for round and rectangular jets. Comparisons of the prediction results with data show that the noise model predicts the observed increase in low-frequency noise with the introduction of a third, axisymmetric stream, but not the high-frequency reduction. For an offset third stream, the model predicts the observed trend of decreased sound levels on the thick side of the jet compared with the thin side, but the predicted azimuthal variations are much less than those seen in the data. Also, the shift of the spectral peak to lower frequencies with increasing polar angle is over-predicted. For an offset third stream with a heated core, it is shown that including the enthalpy-flux source terms in the acoustic analogy model improves predictions compared with those obtained using only the momentum- flux.

Three-Stream Jets↗

Surface plasmons in terahertz metamaterials

We characterize terahertz metamaterials by applying apertureless near-field microscopy with a bandwidth that covers the entire spectral response of the structures. The observations agree with the interpretation of the fundamental mode of the metamaterial. But the high frequency resonance shows properties that deviate from the common interpretation. We show that the high frequency response is governed by surface Plasmon excitations, which have a comparable oscillator strength as the fundamental mode.

36 MATERIALS SCIENCE↗

High Resolution ECG for Evaluation of Heart Function During Exposure to Subacute Hypobaric Hypoxia

High altitude climbing presents a wide spectrum of health risks, including exposure to hypobaric hypoxia. Risks are also typically exacerbated by the difficulty in appropriately monitoring for early signs of organ dysfunction in remote areas. We investigated whether high resolution advanced ECG analysis might be helpful as a non-invasive and easy-to-use tool (e.g., instead of Doppler echocardiography) for evaluating early signs of heart overload in hypobaric hypoxia. Nine non-acclimatized healthy trained alpine rescuers (age 43.7 plus or minus 7.3 years) climbed in four days to the altitude of 4,200 m on Mount Ararat. Five-minute high-resolution 12-lead electrocardiograms (ECGs) were recorded (Cardiosoft) in each subject at rest in the supine position on different days but at the same time of day at four different altitudes: 400 m (reference altitude), 1,700 m, 3,200 m and 4,200 m. Changes in conventional and advanced resting ECG parameters, including in beat-to-beat QT and RR variability, waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG was estimated by calculation of the regression coefficients in independent linear regression models. A p-value of less than 0.05 was adopted as statistically significant. As expected, the RR interval and its variability both decreased with increasing altitude, with trends k = -96 ms/1000 m with p = 0.000 and k = -9 ms/1000 m with p = 0.001, respectively. Significant changes were found in P-wave amplitude, which nearly doubled from the lowest to the highest altitude (k = 41.6 microvolt/1000 m with p = 0.000), and nearly significant changes in P-wave duration (k = 2.9 ms/1000 m with p = 0.059). Changes were less significant or non-significant in other studied parameters including those of waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG. High resolution ECG analysis, particularly of the P wave, shows promise as a tool for monitoring early changes in heart function due to exposure to high altitude.

Zupet, Petra↗

Water-stress-induced breakdown of carbon–water relations: indicators from diurnal FLUXNET patterns

Understanding of terrestrial carbon and water cycles is currently hampered by an uncertainty in how to capture the large variety of plant responses to drought. In FLUXNET, the global network of CO 2 and H 2 O flux observations, many sites do not uniformly report the ancillary variables needed to study drought response physiology. To this end, we outline two data-driven indicators based on diurnal energy, water, and carbon flux patterns derived directly from the eddy covariance data and based on theorized physiological responses to hydraulic and non-stomatal limitations.Hydraulic limitations (i.e. intra-plant limitations on water movement) are proxied using the relative diurnal centroid ( C ET * ), whichmeasures the degree to which the flux of evapotranspiration (ET) is shiftedtoward the morning. Non-stomatal limitations (e.g. inhibitions of biochemical reactions, RuBisCO activity, and/or mesophyll conductance) are characterized by the Diurnal Water–Carbon Index (DWCI), which measures the degree of coupling between ET and gross primary productivity (GPP) within each day.As a proof of concept we show the response of the metrics at six European sites during the 2003 heat wave event, showing a varied response of morning shifts and decoupling. Globally, we found indications of hydraulic limitations in the form of significantly high frequencies of morning-shifted days in dry/Mediterranean climates and savanna/evergreen plant functional types (PFTs), whereas high frequencies of decoupling were dominated by dry climates and grassland/savanna PFTs indicating a prevalence of non-stomatal limitations in these ecosystems. Wholly, both the diurnal centroid and DWCI were associated with high net radiation and low latent energy typical of drought. Using three water use efficiency (WUE) models, we found the mean differences between expected and observed WUE to be - 0.09 to0.44 µ mol mmol -1 and - 0.29 to - 0.40 µ mol mmol -1 for decoupled and morning-shifted days, respectively, compared to mean differences - 1.41 to - 1.42 µ mol mmol -1 in dry conditions, suggesting that morning shifts/hydraulic responses are associated with an increase in WUE,whereas decoupling/non-stomatal limitations are not.

58 GEOSCIENCES↗

Study of noise reduction characteristics of double-wall panels

The noise reduction characteristics of general aviation type, flat, double-wall structures were investigated. The experimental study was carried out on 20-by-20 inch panels with an exposed area of 18 by 18 inches. A frequency range from 20 to 5000 Hz was covered. The experimental results, in general, follow the expected trends. At low frequencies the double-wall structures are no better than the single-wall structures. However, for depths normally used in the general aviation industry, the double-wall panels are very attractive. The graphite-spoxy skin panels have higher noise reduction at very low frequencies ( 100 Hz) than the Kevlar skin panels. But the aluminum panels have higher noise reduction in the high frequency region, due to their greater mass. Use of fiberglass insulation is not effective in the low frequency region, and at times it is even negative. But the insulation is effective in the high-frequency region. The theoretical model for predicting the transmission loss of these multilayered panels is also discussed.

Navaneethan, R.↗

Output Capacitance Loss of GaN HEMTs in Steady-State Switching

The output capacitance (C OSS ) loss, a loss produced when the device’s output capacitor is charged and discharged, has become a concern for GaN high electron mobility transistors (HEMTs) in high-frequency applications. This work presents a new, easy-to-implement method for the C OSS loss characterization based on the unclamped inductive switching (UIS) setup. As compared to prior approaches, this method involves the device’s ON-state conduction and could measure the C OSS loss in a single pulse and the steady-state switching. The C OSS loss of three types of mainstream commercial GaN HEMTs is characterized, which exhibit some common dependencies including a non-monotonic relation with the dv/dt (or resonance frequency), a linear relation with the ON-state current, a power-law relation with the peak blocking voltage, and little temperature dependence. In addition, their C OSS losses all show minimal distinctions in a single pulse and the steady-state switching, despite the increased on-resistance in the steady-state switching. Furthermore, this suggests that the traps accounting for the C OSS loss possess different de-trapping time constants as compared to the traps governing the dynamic on-resistance. Finally, a unified model is established to describe the C OSS loss of all three types of GaN HEMTs. These results provide important references for the high-frequency application of GaN HEMTs and new insights into the physical origin of their C OSS loss.1

42 ENGINEERING↗

Microwave soft x-ray microscopy for nanoscale magnetization dynamics in the 5–10 GHz frequency range

We present a scanning transmission x-ray microscopy setup combined with a novel microwave synchronization scheme for studying high frequency magnetization dynamics at synchrotron light sources. The sensitivity necessary to detect small changes in the magnetization on short time scales and nanometer spatial dimensions is achieved by combining the excitation mechanism with single photon counting electronics that is locked to the synchrotron operation frequency. Our instrument is capable of creating direct images of dynamical phenomena in the 5-10 GHz range, with high spatial resolution. When used together with circularly polarized x-rays, the above capabilities can be combined to study magnetic phenomena at microwave frequencies, such as ferromagnetic resonance (FMR) and spin waves. We demonstrate the capabilities of our technique by presenting phase resolved images of a ∼6 GHz nanoscale spin wave generated by a spin torque oscillator, as well as the uniform ferromagnetic precession with ∼0.1° amplitude at ∼9 GHz in a micrometer-sized cobalt strip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗