Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Insulated Concrete Form Walls Integrated With Mechanical Systems in a Cold Climate Test House

Transitioning from standard light frame to a thermal mass wall system in a high performance home will require a higher level of design integration with the mechanical systems. The much higher mass in the ICF wall influences heat transfer through the wall and affects how the heating and cooling system responds to changing outdoor conditions. This is even more important for efficient, low-load homes with efficient heat pump systems in colder climates where the heating and cooling peak loads are significantly different from standard construction. This report analyzes a range of design features and component performance estimates in an effort to select practical, cost-effective solutions for high performance homes in a cold climate. Of primary interest is the influence of the ICF walls on developing an effective air sealing strategy and selecting an appropriate heating and cooling equipment type and capacity. The domestic water heating system is analyzed for costs and savings to investigate options for higher efficiency electric water heating. A method to ensure mechanical ventilation air flows is examined. The final solution package includes high-R mass walls, very low infiltration rates, multi-stage heat pump heating, solar thermal domestic hot water system, and energy recovery ventilation. This solution package can be used for homes to exceed 2012 International Energy Conservation Code requirements throughout all climate zones and achieves the DOE Challenge Home certification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Landing Characteristics of the Apollo Spacecraft with Deployed Heat Shield Impact Attenuation Systems

An experimental investigation was made to determine the landing characteristics of a 1/4-scale dynamic model of the Apollo spacecraft command module using two different active (heat shield deployed prior to landing) landing systems for impact attenuation. One landing system (configuration 1) consisted of six hydraulic struts and eight crushable honeycomb struts. The other landing system (configuration 2), consisted of four hydraulic struts and six strain straps. Tests made on water and the hard clay-gravel composite landing surfaces simulated parachute letdown (vertical) velocities of 23 ft/sec (7.0 m/s) (full scale). Landings made on the sand landing surface simulated vertical velocities of 30 ft/sec (9.1 m/s). Horizontal velocities of from 0 to 50 ft/sec (15 m/s) were simulated. Landing attitudes ranged from -30'degrees to 20 degrees, and the roll attitudes were O degrees, 90 degrees, and 180 degrees. For configuration 1, maximum normal accelerations at the vehicle center of gravity for landings on water, sand, and the hard clay-gravel composite surface were 9g, 20g, and 18g, respectively. The maximum normal center-of-gravity acceleration for configuration 2 which was landed only on the hard clay-gravel landing surface was approximately 19g. Accelerations for configuration 2 were generally equal to or lower than accelerations for configuration 1 and normal.

EXPERIMENTS↗

Radioisotope Power System Cask Trailer Chiller Low Heat Load Study

This report documents the study of the Radioisotope Thermoelectric Generator Transport System (RTGTS) chillers capability to transport a Radioisotope Power System (RPS) with low heat loads in the cask. Tests of the RTGTS chillers included setting the glycol/water (coolant) temperature to a control set point of 40° and 60°F while applying heat loads ranging from 2500 to 0 W heat load. The tests performed showed that the chiller systems could handle the entire range of heat loads. However, a noise/vibration started to occur when the set point was 60°F with low heat loads. Three recommended changes to the RTGTS chillers are recommended with varying implementation windows. The first is an operational change that can be implemented immediately. The RTGTS chillers should have a set point of 40°F when transporting an RPS less than 1500 W. The second is a short-term change (within the next two years) augmenting RPS heat by utilizing one RTGTS onboard heater (2500 W) while transporting an RPS with less than 1500 W which will also require a change to the Instrument and Data Acquisition System (IDAS) to allow monitoring and possible control of power to the onboard heaters. However, if the heater does fail during transport, no emergency actions or immediate repairs will be required due to the chillers’ ability to handle low heat loads. Running a 2500 W heater when transporting low heat loads aids in prolonging the life of the chillers. The remaining recommended long-term change is to replace the current chillers with a new portable or permanently installed chiller system in the next five to ten years. This time frame takes advantage of the proven reliability and durability of the current chillers while the new chillers are phased in and proven to the RPS program.

42 ENGINEERING↗

Facilitating Energy Savings through Enhanced Usability of Thermostats

Residential thermostats play a key role in controlling heating and cooling systems. Occupants often find the controls of programmable thermostats confusing, sometimes leading to higher heating consumption than when the buildings are controlled manually. A high degree of usability is vital to a programmable thermostat's effectiveness because, unlike a more efficient heating system, occupants must engage in specific actions after installation to obtain energy savings. We developed a procedure for measuring the usability of thermostats and tested this methodology with 31 subjects on five thermostats. The procedure requires first identifying representative tasks associated with the device and then testing the subjects ability to accomplish those tasks. The procedure was able to demonstrate the subjects wide ability to accomplish tasks and the influence of a device's usability on success rates. A metric based on the time to accomplish the tasks and the fraction of subjects actually completing the tasks captured the key aspects of each thermostat's usability. The procedure was recently adopted by the Energy Star Program for its thermostat specification. The approach appears suitable for quantifying usability of controls in other products, such as heat pump water heaters and commercial lighting.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Heat Rejection Concepts for Brayton Power Conversion Systems

This paper describes potential heat rejection design concepts for closed Brayton cycle (CBC) power conversion systems. Brayton conversion systems are currently under study by NASA for Nuclear Electric Propulsion (NEP) applications. The Heat Rejection Subsystem (HRS) must dissipate waste heat generated by the power conversion system due to inefficiencies in the thermal-to-electric conversion process. Space Brayton conversion system designs tend to optimize at efficiencies of about 20 to 25 percent with radiator temperatures in the 400 to 600 K range. A notional HRS was developed for a 100 kWe-class Brayton power system that uses a pumped sodium-potassium (NaK) heat transport loop coupled to a water heat pipe radiator. The radiator panels employ a sandwich construction consisting of regularly-spaced circular heat pipes contained within two composite facesheets. Heat transfer from the NaK fluid to the heat pipes is accomplished by inserting the evaporator sections into the NaK duct channel. The paper evaluates various design parameters including heat pipe diameter, heat pipe spacing, and facesheet thickness. Parameters were varied to compare design options on the basis of NaK pump pressure rise and required power, heat pipe unit power and radial flux, radiator panel areal mass, and overall HRS mass.

Siamidis, John↗

Thermodynamic analysis of dilute ternary systems. 1. The Ag-Au-Sn system

The heats of solution of silver and gold in dilute Ag-Au-Sn alloys have been determined as a function of alloy composition using liquid metal solution calorimetry. From the values obtained, the various enthalpy interaction parameters in the liquid solutions have been calculated. The results are interpreted in terms of the probably bonding changes taking place between silver, gold and tin atoms.

P J Spencer↗

Thermodynamic analysis of dilute ternary systems. I.

The heats of solution of silver and gold in dilute Ag-Au-Sn alloys have been determined as a function of alloy composition using liquid metal solution calorimetry. From the values obtained, the various enthalpy interaction parameters in the liquid solutions have been calculated. The results are interpreted in terms of the probably bonding changes taking place between silver, gold and tin atoms.

P J Spencer↗

Thermal modeling of lithium systems

The heat generation during cell discharge and its distribution are discussed. The effects of casing materials, thickness of current collectors, discharge environments, and entropies are described. A number of calorimetric experiments are described which quantify the heat during cell discharge.

Kim, K. Y.↗

Comparison of methodologies for describing relaxation in nonequilibrium gaseous systems

The heat transfer process in hypervelocity vehicles is dominated by nonequilibrium gas dynamics. One model used in computational fluid dynamics (CFD) codes to predict hypervelocity heat transfer is the 'two-temperature' model. An analysis has been made to test the validity of the two-temperature model for predicting another nonequilibrium phenomenon, sound absorption and deviation of signal speed in a high temperature gas. It is found that the two temperature model's prediction capabilities degenerate with increasing temperature. These results are felt to have significance concerning the two-temperature's ability to predict heat transfer in hypervelocity flows.

Schreiber, Willard C.↗

FY23 Report on Water NSTF Testing at Two-Phase Conditions: Off-normal Scenarios

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report details the experimental activities and upgrades performed during the program’s fifth year of water-based operation. The theme of this year of testing was examining off-normal scenarios. In practice, that meant examining scenarios with blockages or other design basis conditions. From a maintenance and capability standpoint that meant assessing valving options for implementing blockages, assessing drain and refill capabilities, and ensuring in all cases that operators could safely, efficiently, and repeatably bring the facility to an off-normal condition and return it to the normal operating state. In one notable case, no solution existed, nor was a solution commercially available, that met the facility needs for implementing blockages within the two-phase region of the chimney. A valve and feedthrough were custom-designed for NSTF to operate submerged in saturated water while being safely actuated from outside the tank. The fifth year of testing included eight matrix tests consisting of 162 hours of active heating, 9,735 kWh of electrical heating, with seven tests classified as Accepted per NQA-1 and one as Trending. All matrix tests were performed at two-phase flow conditions. The power parametric series from previous years was extended to include another scenario with a decay load equivalent to 1.75 MWt, full scale, further resolving the system flow oscillation response as a function of input power. A depletion test was performed to extend previous work and examine the system’s approach to stagnation and geysering that were not previously observed. This test began at an initial inventory level of 50%, prototypic power of 2.1 MWt, and employed an accelerated drain of 0.75 gpm plus boiloff until stagnation conditions were achieved and multiple geysering events were recorded. Further exploring the geysering phenomenon was a separate effects test examining static boiling in the risers and chimney. This static boiling test was performed at 48 kWe, a higher power than testing in the previous year, and included enhancements to the drain system to remove inventory in a better-controlled and more reliable manner. Two tests were performed, at prototypic conditions of 1.4 MWt and 2.4 MWt, respectively, examining the system response to throttled conditions in the singlephase region of the piping. A ball valve immediately before he riser inlet header was increasingly throttled, progressing the system through a repeatable pattern of two-phase oscillations and stable regimes before ultimately inducing stagnation and geysering. Concluding the year, two tests were performed at baseline conditions of 70% initial inventory level and 2.1 MWt of prototypic decay heat to examine both repeatability and the response to throttling within the two-phase region, at the inventory tank inlet using the custom valve mentioned above. The first such test repeated transient operating conditions and revealed significant sensitivity t

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Exponential quadratic operators and evolution of bosonic systems coupled to a heat bath

Using exponential quadratic operators, we present a general framework for studying the exact dynamics of system-bath interaction in which the Hamiltonian is described by the quadratic form of bosonic operators. To demonstrate the versatility of the approach, we study how the environment affects the squeezing of quadrature components of the system. We further propose that the squeezing can be enhanced when parity kicks are applied to the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heat pipes for terrestrial applications in dehumidification systems

A novel application of heat pipes which greatly enhances dehumidification performance of air-conditioning systems is presented. When an air-to-air heat pipe heat exchanger is placed between the warm return air and cold supply air streams of an air conditioner, heat is efficiently transferred from the return air to the supply air. As the warm return air precools during this process, it moves closer to its dew-point temperature. Therefore, the cooling system works less to remove moisture. This paper discusses the concept, its benefits, the challenges of incorporating heat pipes in an air-conditioning system, and the preliminary results from a field demonstration of an industrial application.

Khattar, Mukesh K.↗

Novel Controls for Economic Dispatch of Combined Cooling, Heating and Power (CHP) Systems

This fact sheet describes a project by University of California, Irvine, in collaboration with Siemens Corporate Research, to develop and demonstrate novel algorithms and dynamic control technology for optimal economic use of CHP systems under 5 MW. The control systems and technologies are increasing market penetration of CHP systems in the light industrial, commercial, and institutional markets.

Algorithm↗

Low temperature barriers for use with in situ processes

A method of forming and maintaining a low temperature zone around at least a portion of a subsurface treatment area is described. The method includes reducing a temperature of heat transfer fluid with a refrigeration system. The heat transfer fluid is circulated through freeze well canisters and placed in a formation around at least a portion of the subsurface treatment area. An initial temperature of the heat transfer fluid supplied to a first freeze well canister is in a range from about -35 .degree. C. to about -55 .degree. C. At least one of the well canisters includes carbon steel. The heat transfer fluid is returned to the refrigeration system.

36 MATERIALS SCIENCE↗

Beam Induced Effects in the ITER Electrostatic Residual Ion Dump

The effect of beam generated plasma in the channels of the ITER electrostatic residual ion dump (ERID) is investigated. The space charge due to the plasma and the separating positive and negative ion beams could cause the ERID to fail if the plasma density is sufficiently high. The gas density at which this occurs is derived for both the heating and diagnostic beam systems. For the heating beam system this critical density is a factor of 75 higher than the normal operational gas density, so no problems are anticipated. For the diagnostic beam, the critical density is only a factor of 3 higher and under certain circumstances could be exceeded.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scaling Analysis for the Direct Reactor Auxillary Cooling System For AHTRS

The Direct Reactor Auxiliary Cooling System (DRACS) is a passive heat removal system proposed for the Advanced High-Temperature Reactor (AHTR) that combines the coated particle fuel and graphite moderator with a liquid fluoride salt as the coolant. The DRACS features three coupled natural circulation/convection loops relying completely on buoyancy as the driving force. In the DRACS, two heat exchangers, namely, the DRACS Heat Exchanger (DHX) and the Natural Draft Heat Exchanger (NDHX) are used to couple these loops. In addition, a fluidic diode is employed to minimize the parasitic flow during normal operation of the reactor and to activate the DRACS in accidents. While the DRACS concept has been proposed, there are no actual prototypic DRACS systems for AHTRs built and tested in the literature. In this paper, a detailed scaling analysis for the DRACS is performed, which will provide guidance for the design of the scaled-down DRACS test facilities. Based on the Boussinesq assumption and one-dimensional flow formulation, the governing equations are non-dimensionalized by introducing appropriate dimensionless parameters. The key dimensionless numbers that characterize the DRACS system are obtained straightforwardly from the non-dimensional governing equations. Based on the dimensionless numbers and non-dimensional governing equations, similarity laws are proposed. In addition, a scaling methodology has also been developed, which consists of the core scaling and loop scaling. The consistence between the core and loop scaling is examined through the reference volume ratio, which can be obtained from the core and loop scaling processes. The scaling methodology and similarity laws have been applied to obtain a design of the scaled-down high-temperature DRACS test facility (HTDF).

Scaling auxiliary AHTRS DRACS liquid salt molten r↗

The Added Economic and Environmental Value of Solar Thermal Systems in Microgrids with CombinedHeat and Power

The addition of solar thermal and heat storage systems can improve the economic, as well as environmental attraction of micro-generation systems, e.g. fuel cells with or without combined heat and power (CHP) and contribute to enhanced CO2 reduction. However, the interactions between solar thermal collection and storage systems and CHP systems can be complex, depending on the tariff structure, load profile, etc. In order to examine the impact of solar thermal and heat storage on CO2 emissions and annual energy costs, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program. The objective is minimization of annual energy costs. This paper focuses on analysis of the optimal interaction of solar thermal systems, which can be used for domestic hot water, space heating and/or cooling, and micro-CHP systems in the California service territory of San Diego Gas and Electric (SDG&E). Contrary to typical expectations, our results indicate that despite the high solar radiation in southern California, fossil based CHP units are dominant, even with forecast 2020 technology and costs. A CO2 pricing scheme would be needed to incent installation of combined solar thermal absorption chiller systems, and no heat storage systems are adopted. This research also shows that photovoltaic (PV) arrays are favored by CO2 pricing more than solar thermal adoption.

03 NATURAL GAS↗