Demonstration Assessment of Light Emitting Diode (LED) Commercial Garage Lights In the Providence Portland Medical Center, Portland, Oregon

This U.S. Department of Energy GATEWAY Demonstration project studied the applicability of light-emitting diode (LED) luminaires for commercial parking garage applications. High-pressure sodium (HPS) area luminaires were replaced with new LED area luminaires. The project was supported under the U.S. Department of Energy (DOE) Solid State Lighting Program. Other participants in the demonstration project included Providence Portland Medical Center in Portland, Oregon, the Energy Trust of Oregon, and Lighting Sciences Group (LSG) Inc. Pacific Northwest National Laboratory (PNNL) conducted the measurements and analysis of the results. PNNL manages GATEWAY demonstrations for DOE and represents their perspective in the conduct of the work. Quantitative and qualitative measurements of light and electrical power were taken at the site for both HPS and LED light sources. Economic costs were estimated and garage users’ responses to the new light sources were gauged with a survey. Six LED luminaires were installed in the below-ground parking level A, replacing six existing 150W HPS lamps spread out over two rows of parking spaces. Illuminance measurements were taken at floor level approximately every 4 ft on a 60-ft x 40-ft grid to measure light output of these LED luminaires which were termed the “Version 1” luminaires. PNNL conducted power measurements of the circuit in the garage to which the 6 luminaires were connected and determined that they drew an average of 82 W per lamp. An improved LED luminaire, Version 2, was installed in Level B of the parking garage. Illuminance measurements were not made of this second luminaire on site due to higher traffic conditions, but photometric measurements of this lamp and Version 1 were made in an independent testing laboratory and power usage for Version 2 was also measured. Version 1 was found to produce 3600 lumens and Version 2 was found to produce 4700 lumens of light and to consume 78 Watts. Maximum and minimum light levels were measured for the HPS and LED Version 1 luminaires and projected for the Version 2 luminaires. Maximum light levels were 23.51 foot candles, 20.54 fc, and 26.7 fc respectively and minimum light levels were 1.49 fc, 1.45 fc, and 1.88 fc. These results indicate very similar or even slightly higher light levels produced by the LED lamps, despite the higher lumen output of the HPS lamp. The LED lamps provide higher luminaire efficacy because all of the light is directed down and out. None of it is “lost” in the fixture. Also the HPS luminaire had poorly designed optics and a plastic covering that tended to get dirty and cracked, further decreasing the realized light output.[is this an accurate way to say this?] Consumer perceptions of the Version 2 LED were collected via a written survey form given to maintenance and security personnel. More than half felt the LED luminaires provided more light than the HPS lamps and a majority expressed a preference for the new lamps when viewing the relamped area through a security camera. Respondents commented that the LED luminaires were less glary, created less shadows, had a positive impact on visibility, and improved the overall appearance of the area. PNNL conducted an economic analysis and found that the Version 1 lamp produced annual energy savings of 955 kWh and energy cost savings of $76.39 per lamp at electricity rates of 6.5 cents per kWh and $105.03 at 11 cents per kWh. PNNL found that the Version 2 lamp produced annual energy savings of 991 kWh and energy cost savings of $79.26 per lamp at electricity rates of 6.5 cents per kWh and $108.98 at 11 cents per kWh. PNNL also calculated simple payback and found that Version 1 showed paybacks of 5.4 yrs at 6.5c/kWh and 4.1 yrs at 11c/kWh while Version 2 showed paybacks of 5.2 yrs at 6.5c/kWh and 3.9 yrs at 11c/kWh.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Survival after aortic valve replacement for severe aortic stenosis with low transvalvular gradients and severe left ventricular dysfunction

OBJECTIVE: We sought to assess whether aortic valve replacement (AVR) among patients with severe aortic stenosis (AS), severe left ventricular (LV) dysfunction and a low transvalvular gradient (TVG) is associated with improved survival. BACKGROUND: The optimal management of patients with severe AS with severe LV dysfunction and a low TVG remains controversial. METHODS: Between 1990 and 1998, we evaluated 68 patients who underwent AVR at our institution (AVR group) and 89 patients who did not undergo AVR (control group), with an aortic valve area < or = 0.75 cm(2), LV ejection fraction < or = 35% and mean gradient < or = 30 mm Hg. Using propensity analysis, survival was compared between a cohort of 39 patients in the AVR group and 56 patients in the control group. RESULTS: Despite well-matched baseline characteristics among propensity-matched patients, the one- and four-year survival rates were markedly improved in patients in the AVR group (82% and 78%), as compared with patients in the control group (41% and 15%; p < 0.0001). By multivariable analysis, the main predictor of improved survival was AVR (adjusted risk ratio 0.19, 95% confidence interval 0.09 to 0.39; p < 0.0001). The only other predictors of mortality were age and the serum creatinine level. CONCLUSIONS: Among select patients with severe AS, severe LV dysfunction and a low TVG, AVR was associated with significantly improved survival.

NASA Discipline Cardiopulmonary↗

Safety in the operating theatre--part 1: interpersonal relationships and team performance

The authors examine the application of interpersonal human factors training on operating room (OR) personnel. Mortality studies of OR deaths and critical incident studies of anesthesia are examined to determine the role of human error in OR incidents. Theoretical models of system vulnerability to accidents are presented with emphasis on a systems approach to OR performance. Input, process, and outcome factors are discussed in detail.

Non-NASA Center↗

A health maintenance facility for space station freedom

We describe a health care facility to be built and used on an orbiting space station in low Earth orbit. This facility, called the health maintenance facility, is based on and modeled after isolated terrestrial medical facilities. It will provide a phased approach to health care for the crews of Space Station Freedom. This paper presents the capabilities of the health maintenance facility. As Freedom is constructed over the next decade there will be an increase in activities, both construction and scientific. The health maintenance facility will evolve with this process until it is a mature, complete, stand-alone health care facility that establishes a foundation to support interplanetary travel. As our experience in space continues to grow so will the commitment to providing health care.

Health Promotion/organization & administration/sta↗

Abbreviated Pandemic Influenza Planning Template for Primary Care Offices

The Abbreviated Pandemic Influenza Plan Template for Primary Care Provider Offices is intended to assist primary care providers and office managers with preparing their offices for quickly putting a plan in place to handle an increase in patient calls and visits, whether during the 2009-2010 influenza season or future influenza seasons.

99 GENERAL AND MISCELLANEOUS↗

Medical Actinium Therapeutic Treatment

Learn how INL researchers are increasing world supplies of Bismuth 213 to help with cancer treatments. For more information about INL research projects, visit http://www.facebook.com/idahonationallaboratory.

01 COAL, LIGNITE, AND PEAT↗

Bismuth 213 Cancer Treatment

See how INL scientists are increasing supplies of radioactive medical isotopes to treat cancer. For more information about INL research, visit http://www.facebook.com/idahonationallaboratory.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Greensburg, Kansas: A Better, Greener Place to Live

The brochure highlights efforts to rebuild green in Greensburg, KS, and mentions DOE's role in rebuilding. The layout is designed to be used as a template for other cities in similar situations.

Commercial, Government, Multifamily, Offices, Reta↗

Installing Hotel Rooftop Solar Array

This case study describes how a luxury hotel, Bardessono, utilized a major roof-top solar array in its design to achieve significant energy savings and LEED Platinum certification.

LEED, LEED Platinum, rooftop array, solar, solar p↗

Casino Parking Structures: Lighting Energy Efficiency in Parking Campaign

This case study provides an overview of MGM Resorts International’s (MGM) efforts to drive energy savings by installing energy-efficient parking area lighting and controls at 65% of its U.S. facilities. MGM replaced more than 4,400 existing metal halide and high-pressure sodium light fixtures in the parking facilities with a mixture of LED and induction fixtures, saving 4.5 million kWh per year across its portfolio.

Lighting, parking, efficiency, payback, LED, hotel↗

Retrofits for Multi-load Commercial Washers

This document summarizes a series of demonstrations of energy-efficient technologies in multi-load washers in 2 hotels and an assisted living facility. The study focused on wastewater recycling systems and ozone systems.

commercial, retrofits, water heating, water effici↗