Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Function Estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Simulations of Material-Dependent Detector Responses for Airborne Gamma-Ray Spectroscopy

The aim of this work is to create a library of predicted detector responses used for real-time background estimation during airborne gamma-ray spectroscopy. The simulated spectra are a function of naturally occurring radioactive potassium, uranium, and thorium (KUT) and radioactive daughter products which are present in terrestrial-based materials. Self-attenuation within these materials varies, such that the gamma spectra emitted from the surfaces can differ, despite all having KUT origins. This study also compared various simulated detector responses among materials to determine if some could be accurately scaled from another across reasonable helicopter altitudes and orientations, relative to the ground. Results show that materials with comparable sample thicknesses can be scaled consistently across altitude. This work allows for efficient background estimation via aggregation of simulated detector responses in real time.

radioactive potassium, uranium, and thorium, KUT, ↗

SU-E-T-422: Fast Analytical Beamlet Optimization for Volumetric Intensity-Modulated Arc Therapy

Purpose: To implement a fast optimization algorithm on CPU/GPU heterogeneous computing platform and to obtain an optimal fluence for a given target dose distribution from the pre-calculated beamlets in an analytical approach. Methods: The 2D target dose distribution was modeled as an n-dimensional vector and estimated by a linear combination of independent basis vectors. The basis set was composed of the pre-calculated beamlet dose distributions at every 6 degrees of gantry angle and the cost function was set as the magnitude square of the vector difference between the target and the estimated dose distribution. The optimal weighting of the basis, which corresponds to the optimal fluence, was obtained analytically by the least square method. Those basis vectors with a positive weighting were selected for entering into the next level of optimization. Totally, 7 levels of optimization were implemented in the study.Ten head-and-neck and ten prostate carcinoma cases were selected for the study and mapped to a round water phantom with a diameter of 20cm. The Matlab computation was performed in a heterogeneous programming environment with Intel i7 CPU and NVIDIA Geforce 840M GPU. Results: In all selected cases, the estimated dose distribution was in a good agreement with the given target dose distribution and their correlation coefficients were found to be in the range of 0.9992 to 0.9997. Their root-mean-square error was monotonically decreasing and converging after 7 cycles of optimization. The computation took only about 10 seconds and the optimal fluence maps at each gantry angle throughout an arc were quickly obtained. Conclusion: An analytical approach is derived for finding the optimal fluence for a given target dose distribution and a fast optimization algorithm implemented on the CPU/GPU heterogeneous computing environment greatly reduces the optimization time.

60 APPLIED LIFE SCIENCES↗

In-Home Mobility Frequency and Stability in Older Adults Living Alone With or Without MCI: Introduction of New Metrics

Background: Older adults spend a considerable amount of time inside their residences; however, most research investigates out-of-home mobility and its health correlates. We measured indoor mobility using room-to-room transitions, tested their psychometric properties, and correlated indoor mobility with cognitive and functional status. Materials and Methods: Community-dwelling older adults living alone ( n = 139; age = 78.1 ± 8.6 years) from the Oregon Center for Aging & Technology (ORCATECH) and Minority Aging Research Study (MARS) were included in the study. Two indoor mobility features were developed using non-parametric parameters (frequency; stability): Indoor mobility frequency (room-to-room transitions/day) was detected using passive infrared (PIR) motion sensors fixed on the walls in four geographic locations (bathroom; bedroom; kitchen; living room) and using door contact sensors attached to the egress door in the entrance. Indoor mobility stability was estimated by variances of number of room-to-room transitions over a week. Test-retest reliability (Intra-class coefficient, ICC) and the minimal clinically important difference (MCID) defined as the standard error of measurement (SEM) were generated. Generalized estimating equations models related mobility features with mild cognitive impairment (MCI) and functional status (gait speed). Results: An average of 206 days (±127) of sensor data were analyzed per individual. Indoor mobility frequency and stability showed good to excellent test-retest reliability (ICCs = 0.91[0.88–0.94]; 0.59[0.48–0.70]). The MCIDs of mobility frequency and mobility stability were 18 and 0.09, respectively. On average, a higher indoor mobility frequency was associated with faster gait speed (β = 0.53, p = 0.04), suggesting an increase of 5.3 room-to-room transitions per day was associated with an increase of 10 cm/s gait speed. A decrease in mobility stability was associated with MCI (β = −0.04, p = 0.03). Discussion: Mobility frequency and stability in the home are clinically meaningful and reliable features. Pervasive-sensing systems deployed in homes can objectively reveal cognitive and functional status in older adults who live alone.

Wu, Chao-Yi↗

MODFLOW6 models used to evaluate potential stresses and hydrologic conditions driving water-level fluctuations in well ER-5-3-2, Frenchman Flat, Southern Nevada

The hydrograph for well ER-5-3-2 in Frenchman Flat, southern Nevada, has previously unexplained water-level fluctuations. Four, three-dimensional, groundwater models (MODFLOW 6) were developed to evaluate potential stresses and hydrologic conditions affecting the well ER-5-3-2 hydrograph. Four model scenarios were developed that simulated: (1) wellbore leakage without recharge, (2) wellbore leakage with recharge, (3) shallow (low transmissivity) and deep (high transmissivity) carbonate rocks, and (4) lateral heterogeneity of carbonate rocks. Input and output files for the four model scenarios are in the model and output directories, respectively. Hydraulic conductivity, specific storage, and wellbore-leakage rates (when simulated) were estimated with parameter estimation (PEST) by minimizing a weighted composite, sum-of-squares objective function. The objective function was informed by measurement and Tikhonov regularization observations. Measurement observations included drawdowns from the constant-rate aquifer test and water-level altitudes measured in well ER-5-3-2 from 2001-2021. Tikhonov regularization informed hydraulic conductivity and specific storage parameters that were insensitive to measurement observations, where homogeneity was the preferred relation. Batch files, executables, and MODFLOW 6, PEST, and post-processing utilities are in the ancillary directory. Supplementary data also are included in the ancillary directory, including site information, high-frequency water-level and aquifer-test data, transmissivity estimates, water-chemistry data, and water-temperature analyses. This USGS data release contains data, analyses, and model files for the simulations and analysis results described in U.S. Geological Survey Scientific Investigations Report (https://doi.org/10.3133/sir20225132).

54 ENVIRONMENTAL SCIENCES↗

On the inward drift of runaway electrons during the plateau phase of runaway current

The well observed inward drift of current carrying runaway electrons during runaway plateau phase after disruption is studied by considering the phase space dynamic of runaways in a large aspect ratio toroidal system. We consider the case where the toroidal field is unperturbed and the toroidal symmetry of the system is preserved. The balance between the change in canonical angular momentum and the input of mechanical angular momentum in such a system requires runaways to drift horizontally in configuration space for any given change in momentum space. The dynamic of this drift can be obtained by integrating the modified Euler-Lagrange equation over one bounce time. It is then found that runaway electrons will always drift inward as long as they are decelerating. This drift motion is essentially non-linear, since the current is carried by runaways themselves, and any runaway drift relative to the magnetic axis will cause further displacement of the axis itself. A simplified analytical model is constructed to describe such inward drift both in the ideal wall case and no wall case, and the runaway current center displacement as a function of parallel momentum variation is obtained. The time scale of such displacement is estimated by considering effective radiation drag, which shows reasonable agreement with the observed displacement time scale. Furthermore, this indicates that the phase space dynamic studied here plays a major role in the horizontal displacement of runaway electrons during plateau phase. (C) 2016 AIP Publishing LLC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantification of Kinetic Rate Law Parameters of Uranium Release from Sodium Autunite as a Function of Aqueous Bicarbonate Concentrations

ABSTRACT: Hydrogen carbonate is one of the most significant components within the uranium geochemical cycle. In aqueous solutions, hydrogen carbonate forms strong complexes with uranium. As such, aqueous bicarbonate may significantly increase the rate of uranium release from uranium minerals. Quantifying the relationship of aqueous hydrogen carbonate solutions to the rate of uranium release during dissolution is critical to understanding the long-term fate of uranium within the environment. Single-pass flow-through (SPTF) experiments were conducted to estimate the rate of uranium release from Na meta-autunite as a function of bicarbonate solutions (0.0005-0.003 M) under the pH range of 6-11 and temperatures of 5-60oC. Consistent with the results of previous investigation, the rate of uranium release from sodium autunite exhibited minimal dependency on temperature; but were strongly dependent on pH and increasing concentrations of bicarbonate solutions. Most notably at pH 7, the rate of uranium release exhibited 370 fold increases relative to the rate of uranium release in the absence of bicarbonate. However, the effect of increasing concentrations of bicarbonate solutions on the release of uranium was significantly less under higher pH conditions. It is postulated that at high pH values, surface sites are saturated with carbonate, thus the addition of more bicarbonate would have less effect on uranium release. Results indicate the activation energies were unaffected by temperature and bicarbonate concentration variations, but were strongly dependent on pH conditions. As pH increased from 6 to 11, activation energy values were observed to decrease from 29.94 kJ mol-1 to 13.07 kJ mol-1. The calculated activation energies suggest a surface controlled dissolution mechanism.

Aqueous Bicarbonate↗

GREEN'S FUNCTIONS FOR FAR-SIDE SEISMIC IMAGES: A POLAR-EXPANSION APPROACH

We have computed seismic images of magnetic activity on the far surface of the Sun by using a seismic-holography technique. As in previous works, the method is based on the comparison of waves going in and out of a particular point in the Sun, but we have computed here Green's functions from a spherical polar expansion of the adiabatic wave equations in the Cowling approximation instead of using the ray-path approximation previously used in the far-side holography. A comparison between the results obtained using the ray theory and the spherical polar expansion is shown. We use the gravito-acoustic wave equation in the local plane-parallel limit in both cases and for the latter we take the asymptotic approximation for the radial dependences of Green's function. As a result, improved images of the far side can be obtained from the polar-expansion approximation, especially when combining Green's functions corresponding to two and three skips. We also show that the phase corrections in Green's functions due to the incorrect modeling of the uppermost layers of the Sun can be estimated from the eigenfrequencies of the normal modes of oscillation.

79 ASTRONOMY AND ASTROPHYSICS↗

First-principles analysis of anharmonic nuclear motion and thermal transport in thermoelectric materials

We show a first-principles approach for analyzing anharmonic properties of lattice vibrations in solids. We firstly extract harmonic and anharmonic force constants from accurate first-principles calculations based on the density functional theory. Using the many-body perturbation theory of phonons, we then estimate the phonon scattering probability due to anharmonic phonon-phonon interactions. We show the validity of the approach by computing the lattice thermal conductivity of Si, a typical covalent semiconductor, and selected thermoelectric materials PbTe and Bi{sub 2}Te{sub 3} based on the Boltzmann transport equation. We also show that the phonon lifetime and the lattice thermal conductivity of the high-temperature phase of SrTiO{sub 3} can be estimated by employing the perturbation theory on top of the solution of the self-consistent phonon equation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-space atomic dynamics in metallic liquids investigated by inelastic neutron scattering

Understanding the dynamics of liquids at the atomic level remains a major challenge. Even though viscosity is one of the most fundamental properties of liquids, its atomistic origin is not fully elucidated. Through inelastic neutron scattering experiment on levitated metallic liquid droplets, the time-dependent pair correlation function, the Van Hove function, was determined for Z⁢r 50 ⁢C⁢u 50 and Z⁢r 80 ⁢P⁢t 20 liquids at various temperatures. The time for change in local atomic connectivity, τ LC , which is the timescale of atomic bond cutting and forming, is estimated based on the exponential decay of the nearest neighbor peak of the Van Hove function. At high temperatures above the crossover temperature T A , τ LC is equal to the Maxwell relaxation time, τ M =η/G ∞ , where η is the macroscopic shear viscosity and G ∞ is the high-frequency shear modulus. Below T A the ratio of τ M /τ LC increases with decreasing temperature, indicating increased atomic cooperativity as predicted by molecular dynamics simulation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Theoretical estimate of the effect of thermal agitation on ribosome motion generated by stochastic microswimming

The effect of thermal agitation on ribosome motion is evaluated through the Péclet number, assuming that the ribosome is self-propelled along the mRNA during protein synthesis by a swimming stroke consisting of a cycle of stochastically-generated ribosome configurations involving its two subunits. The ribosome velocity probability distribution function is obtained, giving an approximately normal distribution. Its mean and variance together with an estimate of the in vivo free diffusion coefficient of the ribosome and using only configuration changes of small size, give a Péclet number similar to motor proteins and microorganisms. These results suggest the feasibility of the stochastic microswimming hypothesis to explain ribosome motion. - Highlights: • Hypothesis: the ribosome swims along the mRNA during protein synthesis. • How can withstand the thermal agitation of the particles in the surrounding fluid? • The Péclet number Pe is calculated estimating the in vivo diffusion coefficient. • With small size deformations the ribosome has speeds similar to motor proteins. • Similar Pe values for the ribosome and the motor proteins mean feasible hypothesis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interparticle Interactions in Dilute Solutions of Polyelectrolyte Complex Micelles.

The application of dilute solutions of poly electrolyte complex (PEC) micelles for delivering therapeutic nucleic acids into disease sites has gained momentum. This Letter reports a detailed characterization of PEC micelles in dilute solutions including their internal structures and the determination of the interparticle interactions. The polymer concentration ranges from 0.1 to 0.5 wt %, a regime where micelle-micelle interactions are infrequent. We employ synchrotron small-angle X-ray scattering (SAXS) to simultaneously probe the morphology, internal structure, and radius of gyration (R-g) of the self-assemblies formed by charged diblock polyelectrolytes and homopolyelectrolytes. The emerging appearance of the structure factor in SAXS profiles with the increasing polymer concentration demonstrates the presence of the repulsive intermicellar correlations, which is further confirmed by the differences between the "reciprocal R-g" estimated by Guinier approximation and the "real space R-g" determined by pair distribution functions. We find that the soft corona chains tethered on the surface of phase-separated complex domains are compressed when micelles come close to the point where a hard-sphere interaction takes over. These findings contribute to the fundamental understanding of the structure and space-filling constraints in the complexation-driven self-assemblies and advance the rational design of cationic polymer-based nonviral gene delivery vectors.

Wu, Hao↗

Qualifying LaBr3:Ce+Sr detector performance for the Mu2e experiment at Fermilab Using the ELBE Accelerator

A LaBr3:Ce+Sr detector will be used to measure the stopped muon captures at the Mu2e experiment at Fermilab. It has been benchmarked in a test beam experiment performed at the ELBE electron accelerator located at the Helmholtz-Zentrum Dresden-Rossendorf, Germany. ELBE’s pulsed bremsstrahlung beam line was set to deliver an average γ -ray energy of between 4–5 MeV. The detector response was mapped to match Mu2e beam conditions, including rates up to 1 Mcps, energy flux, and time structure. A radioactive calibration source was used to mimic the characteristic 1808.7 keV γ -ray, emitted during the atomic muon nuclear capture in the Mu2e aluminum stopping target. The detector energy resolution was measured as a function of the average energy flux: up to 1 TeV/s for 0.34 s, the steady-operation beam-on time and up to 4 TeV/s for 5 ms to get a conservative estimate of the effect of high intensity Mu2e beam fluctuations. The PMT gain variation as a function of the beam spill length and average intensity has been parametrized and corrected for. When a PMT gain correction corresponding to the average beam-spill intensity is applied, the residual effect of beam intensity fluctuations around the average degrades the energy resolution, σ E γ /E γ , at 1808.7 keV from 0.66% to 0.83%.

Huang, Shihua [Purdue U., West Lafayette]↗

Kinetics of Silicon field evaporation

Highlights: • A theory of field evaporation developed for metals is applied to Silicon. • Potential energy curves and evaporation field strengths are calculated with density functional theory. • Good agreement with experimental results is obtained for Silicon. The theory of field evaporation, previously developed for metals and adsorbates, is applied to semiconductors and insulators, specifically Si. Potential energy curves and evaporation field strengths of Si{sub 6} and Si{sub 7} are calculated with density functional theory. The evaporation field strength is found to be proportional to the coordination. Good agreement with experimental results is obtained for Silicon as well as an estimate of the experimental field strength.

36 MATERIALS SCIENCE↗

Direction-dependent localization errors in SPECT images

Purpose: Single photon emission computed tomography (SPECT) is being investigated for imaging inside radiation therapy treatment rooms to localize biological targets. Here, computer simulations were used to analyze locational and directional dependencies in localization errors and to assess the effects of spatial resolution modeling and observer normalization on localization performance. Methods: SPECT images of the XCAT phantom, containing 12 hot tumors, were reconstructed with detector response function compensation (DRC) and without DRC (nDRC). Numerical observers were forced to select the most suspicious tumor location, using normalized cross correlation (NXC) or un-normalized cross correlation (XC), from 3 cm diameter search volumes that each contained only one tumor. For each tumor site, localization was optimized as a function of the iteration number and postreconstruction smoothing. Localization error, the distance between true and estimated tumor positions, was calculated across the ensembles of 80 images. Direction-dependent localization bias and precision were estimated from the image ensemble. Results: For the six superficial tumors in close proximity to the detector trajectory, mean localization errors were <2 mm and were lowest or comparable using DRC-NXC, though differences from DRC-XC and nDRC-NXC were not statistically significant. DRC-NXC did provide statistically significantly better localization than nDRC-XC for five of these six tumors. At the other six sites where attenuation was more severe and the distance was generally greater between the tumor and detector, DRC typically did not show better localization than nDRC. Observer normalization improved the localization substantially for a tumor near the hotter heart. Localization errors were anisotropic and dependent on tumor location relative to the detector trajectory. Conclusions: This computer-simulation study compared localization performance for normalized and un-normalized numerical observers, which were used to estimate tumor positions in SPECT images, reconstructed with and without DRC. For tumors localized to <2 mm on average, which are good candidates for SPECT-guided radiation therapy, localization performance typically improved by compensating for the detector response function and by using a normalized observer. The observed direction-dependent localization errors have important implications for radiation therapy and are relevant to SPECT imaging in general.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Material and Energy Efficiency: A Framework for Broader Analysis of Energy Use in the U.S. Economy

Energy efficiency analysis has focused predominantly on reducing energy at its point of use by individual components, processes, or products. Efforts to address the energy embodied in materials through strategies and technologies that reduce raw material production - while maintaining the function and use of materials - offer a complementary and expansive approach to traditional energy efficiency analysis. The U.S. Department of Energy (DOE) energy analysis community currently lacks analytical tools that are appropriate for 1) estimating on a product and economy-wide basis energy efficiency potential achieved through material efficiency strategies and 2) evaluating how these new strategies may complement existing energy efficiency efforts. The goal of this report is to describe a standardized analysis framework that would enable calculation of embodied and direct energy and the estimation of energy reduction potential achieved through changes in material use. The proposed framework meets this functionality by spanning the entire U.S. economy, including international trade flows; capturing material and energy use in products and services from raw material extraction to retirement; maintaining material and energy balances; and adjusting dynamically to absolute and relative changes in materials and energy use. The framework is composed of two main elements: a dynamic hybrid input-output (IO) model and a material energy identity. The hybrid IO model defines recipes for material and energy flows in physical (e.g., British thermal units [Btus] and tons) and monetary units, and allows for dynamic adjustments to the amount of materials and energy used. The second element of the analytical framework, the material energy identity, acts as a way of identifying and organizing energy and material efficiency strategies, which are then implemented and analyzed in the hybrid IO model. The report also provides a simple example application of the proposed framework, which illustrates the concept of reducing energy use through changes to material efficiency.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

pvlib iotools—Open-source Python functions for seamless access to solar irradiance data

Access to accurate solar resource data is critical for numerous applications, including estimating the yield of solar energy systems, developing radiation models, and validating irradiance datasets. However, lack of standardization in data formats and access interfaces across providers constitutes a major barrier to entry for new users. pvlib python’s iotools subpackage aims to solve this issue by providing standardized Python functions for reading local files and retrieving data from external providers. All functions follow a uniform pattern and return convenient data outputs, allowing users to seamlessly switch between data providers and explore alternative datasets. The pvlib package is community-developed on GitHub: https://github.com/pvlib/pvlib-python. As of pvlib python version 0.9.5, the iotools subpackage supports 12 different datasets, including ground measurement, reanalysis, and satellite-derived irradiance data. The supported ground measurement networks include the Baseline Surface Radiation Network (BSRN), NREL MIDC, SRML, SOLRAD, SURFRAD, and the US Climate Reference Network (CRN). Additionally, satellite-derived and reanalysis irradiance data from the following sources are supported: PVGIS (SARAH & ERA5), NSRDB PSM3, and CAMS Radiation Service (including McClear clear-sky irradiance).

14 SOLAR ENERGY↗

Stereo-particle image velocimetry uncertainty quantification

Particle image velocimetry (PIV) measurements are subject to multiple elemental error sources and thus estimating overall measurement uncertainty is challenging. Recent advances have led to a posteriori uncertainty estimation methods for planar two-component PIV. However, no complete methodology exists for uncertainty quantification in stereo PIV. In the current paper, a comprehensive framework is presented to quantify the uncertainty stemming from stereo registration error and combine it with the underlying planar velocity uncertainties. The disparity in particle locations of the dewarped images is used to estimate the positional uncertainty of the world coordinate system, which is then propagated to the uncertainty in the calibration mapping function coefficients. Next, the calibration uncertainty is combined with the planar uncertainty fields of the individual cameras through an uncertainty propagation equation and uncertainty estimates are obtained for all three velocity components. The methodology was tested with synthetic stereo PIV data for different light sheet thicknesses, with and without registration error, and also validated with an experimental vortex ring case from 2014 PIV challenge. Thorough sensitivity analysis was performed to assess the relative impact of the various parameters to the overall uncertainty. The results suggest that in absence of any disparity, the stereo PIV uncertainty prediction method is more sensitive to the planar uncertainty estimates than to the angle uncertainty, although the latter is not negligible for non-zero disparity. Overall the presented uncertainty quantification framework showed excellent agreement between the error and uncertainty RMS values for both the synthetic and the experimental data and demonstrated reliable uncertainty prediction coverage. Finally, this stereo PIV uncertainty quantification framework provides the first comprehensive treatment on the subject and potentially lays foundations applicable to volumetric PIV measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative performance of modern digital mammography systems in a large breast screening program

Purpose: To compare physical measures pertaining to image quality among digital mammography systems utilized in a large breast screening program. To examine qualitatively differences in these measures and differences in clinical cancer detection rates between CR and DR among sites within that program. Methods: As part of the routine quality assurance program for screening, field measurements are made of several variables considered to correlate with the diagnostic quality of medical images including: modulation transfer function, noise equivalent quanta, d′ (an index of lesion detectability) and air kerma to allow estimation of mean glandular dose. In addition, images of the mammography accreditation phantom are evaluated. Results: It was found that overall there were marked differences between the performance measures of DR and CR mammography systems. In particular, the modulation transfer functions obtained with the DR systems were found to be higher, even for larger detector element sizes. Similarly, the noise equivalent quanta, d′, and the phantom scores were higher, while the failure rates associated with low signal-to-noise ratio and high dose were lower with DR. These results were consistent with previous findings in the authors’ program that the breast cancer detection rates at sites employing CR technology were, on average, 30.6% lower than those that used DR mammography. Conclusions: While the clinical study was not large enough to allow a statistically powered system-by-system assessment of cancer detection accuracy, the physical measures expressing spatial resolution, and signal-to-noise ratio are consistent with the published finding that sites employing CR systems had lower cancer detection rates than those using DR systems for screening mammography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗