Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FIRES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Modeling aerosol losses and clothing effects in fires

The described modification of a physiochemical fire model predicts physical effects in clothed humans exposed to elevated temperatures as well as gas and aerosol concentrations in the atmosphere of an aerospace vehicle. The modifications involve the reduction in aerosol concentrations caused by settling and some improvements in dealing with mass and heat transfer effects. Predicted skin temperatures are found to be within 2 C of experimental values for the cases studied, and model predictions of total body enthalpy seem to correlate with symptomology observed experimentally.

Cagliostro, D. E.↗

Modified fire-resistant foams forseat cushions

Modified polyimide-polymer resins are precursors for new family of resilient fire-resistant foams. Terpolyimide foams containing long-chain aliphatic diamines withstand 50,000 cycles of compression over a 200 pound load - an equivalent of 3 years of continuous use as seat cushion filler.

Gagliani, J.↗

Rigid fire-resistant foams for walls and floors

Previous techniques for fabricating rigid fire-resistant polyimide foams by compressing already-foamed precursor have been supplanted by one-step constrained-rise process. Precursor mixed with reinforcing fillers is placed between rigid substrates that constrain expansion of foam as it is heated by microwave energy. Process works for both liquid and powder precursors and can also be adapted to attach woven fiberglass skins at same time prcursor is being foamed.

Gagliani, J.↗

Fire-station solar-energy system--Kansas City, Missouri

Screen-walled, flat-plate air collectors are part of award-winning architectural design; concrete-box storage subsystem, domestic hot-water preheat tank, blowers, pumps, heat exchangers, ducting, controls, and plumbing complete solar system. Design provides half of space heating and 75 percent of heat for domestic hot-water for fire station. Report includes historical narrative of project along with detailed drawings, charts, and product literature.

Source record↗

Fire-resistant materials for aircraft passenger seat construction

The thermal response characteristics of fabric and fabric-foam assemblies are described. The various aspects of the ignition behavior of contemporary aircraft passenger seat upholstery fabric materials relative to fabric materials made from thermally stable polymers are evaluated. The role of the polymeric foam backing on the thermal response of the fabric-foam assembly is also ascertained. The optimum utilization of improved fire-resistant fabric and foam materials in the construction of aircraft passenger seats is suggested.

Fewell, L. L.↗

Fire test method for graphite fiber reinforced plastics

A potential problem in the use of graphite fiber reinforced resin matrix composites is the dispersal of graphite fibers during accidential fires. Airborne, electrically conductive fibers originating from the burning composites could enter and cause shorting in electrical equipment located in surrounding areas. A test method for assessing the burning characteristics of graphite fiber reinforced composites and the effectiveness of the composites in retaining the graphite fibers has been developed. The method utilizes a modified rate of heat release apparatus. The equipment and the testing procedure are described. The application of the test method to the assessment of composite materials is illustrated for two resin matrix/graphite composite systems.

Bowles, K. J.↗

LANDSAT digital analysis of the initial recovery of the Kokolik River tundra fire area, Alaska

The author has identified the following significant results. Considerable regrowth of vegetation was observed between August 1977 and August 1978, both in the field and through analysis of LANDSAT near infrared digital data. The spectral reflectances in the burned areas were found to increase with the age of the burn in a one year period due to vegetation regrowth. Regrowth was particularly evident in the lightly burned portions of the burned area. Image analysis techniques using the AOIPS system permitted delineation of burn severity categories. The conditions and type of ground cover prior to the fire influenced the severity of burning, as did the direction of the winds while the burning was in progress as determined from field and LANDSAT observations. More severe burning was induced by winds blowing in the northeastern and southeastern portions of the burned area.

Hall, D. K.↗

Development of fire-resistant, low smoke generating, thermally stable end items for commercial aircraft and spacecraft using a basic polyimide resin

A terpolyimide precursor was developed which can be foamed by microwave methods and yields foams possessing the best seating properties. A continuous process, based on spray drying techniques, permits production of polyimide powder precursors in large quantities. The constrained rise foaming process permits fabrication of rigid foam panels with improved mechanical properties and almost unlimited density characteristics. Polyimide foam core rigid panels were produced by this technique with woven fiberglass fabric bonded to each side of the panel in a one step microwave process. The fire resistance of polyimide foams was significantly improved by the addition of ceramic fibers to the powder precursors. Foams produced from these compositions are flexible, possess good acoustical attenuation and meet the minimum burnthrough requirements when impinged by high flux flame sources.

Gagliani, J.↗

An assessment of the risk arising from electrical effects associated with carbon fibers released from commercial aircraft fires

The risks associated with electrical effects arising from carbon fibers released from commercial aviation aircraft fires were estimated for 1993. The expected annual losses were estimated to be about $470 (1977 dollars) in 1993. The chances of total losses from electrical effects exceeding $100,000 (1977 dollars) in 1993 were established to be about one in ten thousand.

Kalelkar, A. S.↗

Cogeneration Technology Alternatives Study (CTAS). Volume 6: Computer data. Part 1: Coal-fired nocogeneration process boiler, section A

Various advanced energy conversion systems (ECS) are compared with each other and with current technology systems for their savings in fuel energy, costs, and emissions in individual plants and on a national level. About fifty industrial processes from the largest energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidates which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on-site gasification of coal. Computer generated reports of the fuel consumption and savings, capital costs, economics and emissions of the cogeneration energy conversion systems (ECS's) heat and power matched to the individual industrial processes are presented for coal fired process boilers. National fuel and emissions savings are also reported for each ECS assuming it alone is implemented.

Knightly, W. F.↗

Fire test method for graphite fiber reinforced plastics

A potential problem in the use of graphite fiber reinforced resin matrix composites is the dispersal of graphite fibers during accidental fires. Airborne, electrically conductive fibers originating from the burning composites could enter and cause shorting in electrical equipment located in surrounding areas. A test method for assessing the burning characteristics of graphite fiber reinforced composites and the effectiveness of the composites in retaining the graphite fibers has been developed. The method utilizes a modified Ohio State University Rate of Heat Release apparatus. The equipment and the testing procedure are described. The application of the test method to the assessment of composite materials is illustrated for two resin matrix/graphite composite systems.

Bowles, K. J.↗

Advanced thermoset resins for fire-resistant composites

The thermal and flammability properties of some thermoset polymers and composites are described. The processing and evaluation of composites fabricated from currently used resins and advanced fire-resistant resins are also described. Laboratory test methodology used to qualify candidate composite materials includes thermochemical characterization of the polymeric compounds and evaluation of the glass reinforced composites for flammability and smoke evolution. The use of these test methods will be discussed in comparing advanced laminating resins and composites consisting of modified epoxies, phenolics and bismaleimide, with conventional baseline materials consisting of epoxy.

Kourtides, D. A.↗

Ambient curing fire resistant foams

The feasibility of development of an ambient curing foam is described. The thermal stability and flame spread index of the foams were found to be comparable to those of the high-temperature cured polyimide foams by Monsanto two-foot tunnel test and NASA T-3 Fire test. Adaptation of the material to spray in place applications is described

Hamermesh, C. L.↗

Materials for fire resistant passenger seats in aircraft

The paper considers the selection of cushioning foam and upholstery fabric materials for aircraft passenger seats. Polyurethane, polychloroprene, polyimide, and polyphosphazene are the foam materials considered; and a variety of commercial and developmental fabrics (including wool, cotton, synthetics, and blends) are examined. Viable approaches to the design of fire-resistant seat assemblies are indicated. Results of an experimental laboratory study of fabrics and fabric/foam assemblies exposed to external point-source radiative heat flux are discussed.

Tesoro, G.↗

Structural wood panels with improved fire resistance

Structural wood paneling or other molded wood compositions consisting of finely divided wood chips, flour, or strands are bound together and hot pressed with a modified novolac resin which is the cured product of a prepolymer made from an aralkyl ether or halide with a phenol and a hardening agent such as hexamethylene tetramine. The fire resistance of these articles is further improved by incorporating in the binder certain inorganic fillers, especially a mixture of ammonium oxalate and ammonium phosphate.

Sawko, P. M.↗

Fire extinguishing apparatus having a slidable mass for a penetrator nozzle

A fire extinguishing apparatus for delivering an extinguishing agent through a tarrier surrounding a structure into its interior includes an elongated tubular nozzle body which has a pointed penetrating head carried on one end of the tubular body. A source of extinguishing agent coupled to the opposite end of the tubular body is fed through and passes through passages adjacent the head for delivering the extinguishing agent to the interior of the structure. A slidable mass is carried on the tubular body on a remote end of the tubular body from the penetrating head. By manipulating the slidable mass and bringing such in contact with an abutment the force imparted to the tubular body causes the head to penetrate the structure.

Gray, N. C.↗

Cabin fire simulator lavatory tests

All tests were conducted in the Douglas Cabin Fire Simulator under in-flight ventilation conditions. All tests were allowed to continue for a period of one hour. Data obtained during these tests included: heat flux and temperatures of the lavatory; cabin temperature variations; gas analyses for O2, CO2, CO, HF, HC1, and HCN; respiration and electrocardiogram data on instrumented animal subjects (rats) exposed in the cabin; and color motion pictures. All tests resulted in a survivable cabin condition; however, occupants of the cabin would have been subjected to noxious fumes.

Schutter, K. J.↗