Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Error analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

A Lyapunov and Sacker–Sell spectral stability theory for one-step methods

Approximation theory for Lyapunov and Sacker–Sell spectra based upon QR techniques is used to analyze the stability of a one-step method solving a time-dependent (nonautonomous) linear ordinary differential equation (ODE) initial value problem in terms of the local error. Integral separation is used to characterize the conditioning of stability spectra calculations. The stability of the numerical solution by a one-step method of a nonautonomous linear ODE using real-valued, scalar, nonautonomous linear test equations is justified. This analysis is used to approximate exponential growth/decay rates on finite and infinite time intervals and establish global error bounds for one-step methods approximating uniformly, exponentially stable trajectories of nonautonomous and nonlinear ODEs. A time-dependent stiffness indicator and a one-step method that switches between explicit and implicit Runge–Kutta methods based upon time-dependent stiffness are developed based upon the theoretical results.

97 MATHEMATICS AND COMPUTING↗

ROC analysis in patient specific quality assurance

Purpose: This work investigates the use of receiver operating characteristic (ROC) methods in patient specific IMRT quality assurance (QA) in order to determine unbiased methods to set threshold criteria for {gamma}-distance to agreement measurements. Methods: A group of 17 prostate plans was delivered as planned while a second group of 17 prostate plans was modified with the introduction of random multileaf collimator (MLC) position errors that are normally distributed with {sigma}{approx}{+-}0.5, {+-}1.0, {+-}2.0, and {+-}3.0 mm (a total of 68 modified plans were created). All plans were evaluated using five different {gamma}-criteria. ROC methodology was applied by quantifying the fraction of modified plans reported as 'fail' and unmodified plans reported as 'pass.'Results: {gamma}-based criteria were able to attain nearly 100% sensitivity/specificity in the detection of large random errors ({sigma} > 3 mm). Sensitivity and specificity decrease rapidly for all {gamma}-criteria as the size of error to be detected decreases below 2 mm. Predictive power is null with all criteria used in the detection of small MLC errors ({sigma} < 0.5 mm). Optimal threshold values were established by determining which criteria maximized sensitivity and specificity. For 3%/3 mm {gamma}-criteria, optimal threshold values range from 92% to 99%, whereas for 2%/2 mm, the range was from 77% to 94%. Conclusions: The optimal threshold values that were determined represent a maximized test sensitivity and specificity and are not subject to any user bias. When applied to the datasets that we studied, our results suggest the use of patient specific QA as a safety tool that can effectively prevent large errors (e.g., {sigma} > 3 mm) as opposed to a tool to improve the quality of IMRT delivery.

60 APPLIED LIFE SCIENCES↗

Analysis of the Pressure-Pulse Propagation in Rock: a New Approach to Simultaneously Determine Permeability, Porosity, and Adsorption Capacity

Permeability estimation from pressure-pulse decay method is complicated by two facts: (1) the decay curve often deviates from the single-exponential behavior in the early time period and (2) possible existence of gas adsorption. Both the two factors cause significant permeability error in most of pressure-pulse decay methods. In this paper, we first present a thorough analysis of pressure-pulse propagation process to reveal the mechanism behind the early time and later time behaviors of pressure decay curve. Inspired by the findings from these analyses, a new scaled pressure is proposed which can: (1) be easily used to distinguish the early time and later time data and (2) make the decay curves of all cases into a single 1:1 straight line for later time. A new data-proceeding method, which calculates the apparent porosity and permeability using the same set of measured data, is then developed. The new method could not only remove the effects of the adsorption on the permeability estimation, but also identify the apparent porosity as well as proper adsorption model and parameters. The proposed method is verified by comparing with true values and calculated values through numerical simulations that cover variations in typical rock properties (porosity, permeability, slippage, and adsorption) and the experiment configurations. It is found that the new method is accurate and reliable for all test cases, whereas the Brace’s and Cui’s approaches may cause permeability error in some cases. Lastly, the new method has been successfully applied to real data measured in pressure-pulse decay experiments involving different types of rocks and gases.

58 GEOSCIENCES↗

THE LICK/SDSS LIBRARY. II. [Ca/Fe] AND [Mg/Fe] IN F, G, AND K STARS FROM SDSS-DR7

We analyzed the spectra of 17,600 F, G, and K stars extracted from the seventh Sloan Digital Sky Survey Data Release (SDSS-DR7) database in order to derive ([{alpha}/Fe]), [Ca/Fe], and [Mg/Fe] ratios. Particular attention has been devoted to estimating homogeneous and self-consistent atmospheric parameter values, T{sub eff}, log g, and [Fe/H], by comparing synthetic and observational Lick/SDSS indices. We present results for the sub-sample of more than 4000 spectra whose overall quality allowed us to derive fairly accurate stellar atmospheric parameter values and, therefore, reliable abundance ratios. A Monte Carlo approach was adopted to evaluate both the errors in the observational Lick/SDSS indices and in the derived parameter estimates. The analysis of the trends of [Ca/Fe] and [Mg/Fe] versus [Fe/H] pointed out that (1) the [Ca/Fe] and [Mg/Fe] ratios increase with decreasing [Fe/H] with different slopes reaching maximum average levels of +0.25 and +0.40 dex at [Fe/H] {approx_equal} -1.75, respectively; (2) our sample contains, at a given [Fe/H], stars characterized by significantly different amounts of {alpha}-enhancement, thus belonging to different Galactic populations; and (3) the analyzed sample shows a predominance of thick disk stars for [Fe/H] > - 0.5 and the presence of stars belonging to the 'high-{alpha}' halo population for -2.0 < [Fe/H] <-0.5.

79 ASTRONOMY AND ASTROPHYSICS↗

Low Probability Tail Event Analysis and Mitigation in BPA Control Area: Task One Report

This is a report for task one of the tail event analysis project for BPA. Tail event refers to the situation in a power system when unfavorable forecast errors of load and wind are superposed onto fast load and wind ramps, or non-wind generators falling short of scheduled output, the imbalance between generation and load becomes very significant. This type of events occurs infrequently and appears on the tails of the distribution of system power imbalance; therefore, is referred to as tail events. This report analyzes what happened during the Electric Reliability Council of Texas (ERCOT) reliability event on February 26, 2008, which was widely reported because of the involvement of wind generation. The objective is to identify sources of the problem, solutions to it and potential improvements that can be made to the system. Lessons learned from the analysis include the following: (1) Large mismatch between generation and load can be caused by load forecast error, wind forecast error and generation scheduling control error on traditional generators, or a combination of all of the above; (2) The capability of system balancing resources should be evaluated both in capacity (MW) and in ramp rate (MW/min), and be procured accordingly to meet both requirements. The resources need to be able to cover a range corresponding to the variability of load and wind in the system, additional to other uncertainties; (3) Unexpected ramps caused by load and wind can both become the cause leading to serious issues; (4) A look-ahead tool evaluating system balancing requirement during real-time operations and comparing that with available system resources should be very helpful to system operators in predicting the forthcoming of similar events and planning ahead; and (5) Demand response (only load reduction in ERCOT event) can effectively reduce load-generation mismatch and terminate frequency deviation in an emergency situation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying replication through repeated analysis of UVM-A, a liquid reference material for cosmogenic 10 Be and 26 Al studies

In this study, in-situ produced cosmogenic nuclide sample preparation and analysis is a complicated, multi-step process with numerous possible sources of error, many of which have not been robustly quantified. Here, we use a liquid reference material (UVM-A) to test whether the analytic precision associated with individual isotopic ratios (n = 96) measured at two Accelerator Mass Spectrometry facilities (Lawrence Livermore National Laboratory and Purdue Rare Isotope Measurement Laboratory) accurately represents the range of values determined for aliquots prepared in a single laboratory over a period of five years. We find that 10 Be/ 9 Be ratios measured at the different accelerator facilities (n = 26 and n = 70) have statistically indistinguishable central tendencies, matching to within 0.1 %. Based on this large dataset, we suggest preliminary consensus values for UVM-A of 1.45 ± 0.06 x 10 -13 for 10 Be/ 9 Be (mean, one standard deviation, n = 96) and 4.47 ± 0.22 x 10 -13 for 26 Al/ 27 Al (mean, one standard deviation, n = 27). For both 10 Be/ 9 Be and 26 Al/ 27 Al, the relative standard deviations of the measured ratios are similar to the reported analytic uncertainties of sample measurement, suggesting that sample preparation introduced little if any additional scatter beyond the uncertainty of isotopic analysis. This dataset demonstrates that robust sample preparation and measurement can generate isotope ratio data reproducible at the level of counting statistics.

58 GEOSCIENCES↗

Validation of Multiple Tools for Flat Plate Photovoltaic Modeling Against Measured Data

This report expands upon a previous work by the same authors, published in the 40th IEEE Photovoltaic Specialists conference. In this validation study, comprehensive analysis is performed on nine photovoltaic systems for which NREL could obtain detailed performance data and specifications, including three utility-scale systems and six commercial scale systems. Multiple photovoltaic performance modeling tools were used to model these nine systems, and the error of each tool was analyzed compared to quality-controlled measured performance data. This study shows that, excluding identified outliers, all tools achieve annual errors within +/-8% and hourly root mean squared errors less than 7% for all systems. It is further shown using SAM that module model and irradiance input choices can change the annual error with respect to measured data by as much as 6.6% for these nine systems, although all combinations examined still fall within an annual error range of +/-8.5%. Additionally, a seasonal variation in monthly error is shown for all tools. Finally, the effects of irradiance data uncertainty and the use of default loss assumptions on annual error are explored, and two approaches to reduce the error inherent in photovoltaic modeling are proposed.

14 SOLAR ENERGY↗

Errors in determination of soil water content using time-domain reflectometry caused by soil compaction around wave guides

Application of time domain reflectometry (TDR) in soil hydrology often involves the conversion of TDR-measured dielectric permittivity to water content using universal calibration equations (empirical or physically based). Deviations of soil-specific calibrations from the universal calibrations have been noted and are usually attributed to peculiar composition of soil constituents, such as high content of clay and/or organic matter. Although it is recognized that soil disturbance by TDR waveguides may have impact on measurement errors, to our knowledge, there has not been any quantification of this effect. In this paper, we introduce a method that estimates this error by combining two models: one that describes soil compaction around cylindrical objects and another that translates change in bulk density to evolution of soil water retention characteristics. Our analysis indicates that the compaction pattern depends on the mechanical properties of the soil at the time of installation. The relative error in water content measurement depends on the compaction pattern as well as the water content and water retention properties of the soil. Illustrative calculations based on measured soil mechanical and hydrologic properties from the literature indicate that the measurement errors of using a standard three-prong TDR waveguide could be up to 10%. We also show that the error scales linearly with the ratio of rod radius to the interradius spacing.

54 ENVIRONMENTAL SCIENCES↗

Applications of principal component analysis for energy reconstruction in position-sensitive semiconductor detectors

We report semiconductor detectors with pixelated anodes offer a desirable combination of position sensitivity and energy resolution that are suitable for numerous applications in gamma-ray detection and imaging. Pixelization of electrodes also entails a non-uniform amplitude response as a function of gamma-ray interaction position. Energy calibrations as a function of interaction position improve energy resolution, but systematic errors in the energy reconstruction process persist and limit energy resolution at fixed electronic noise. Digitization of signals induced on collecting and adjacent electrodes offers rich information about gamma-ray interactions and their charge drift and collection as a function of time. Despite the abundance of signals for each interaction, human intuition and rule-based approaches fail to utilize the entire set of observed signals to mitigate the sources of systematic error. In order to maximize the utility of digitized signals and improve energy resolution, principal component analysis is applied towards digitized signals observed in semiconductor detectors with pixelated anodes. Principal components identified in the process form the basis for position-specific energy corrections. By leveraging this additional information encoded within digitized signals, energy resolution improves by factors between 10 and 15% with respect to full-width at half and tenth maximum values. The feature that accounts for the maximum amount of explained variance between interactions in any given pixel correlates strongly with the depth of interaction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detailed analysis of latencies in image-based dynamic MLC tracking

Purpose: Previous measurements of the accuracy of image-based real-time dynamic multileaf collimator (DMLC) tracking show that the major contributor to errors is latency, i.e., the delay between target motion and MLC response. Therefore the purpose of this work was to develop a method for detailed analysis of latency contributions during image-based DMLC tracking. Methods: A prototype DMLC tracking system integrated with a linear accelerator was used for tracking a phantom with an embedded fiducial marker during treatment delivery. The phantom performed a sinusoidal motion. Real-time target localization was based on x-ray images acquired either with a portal imager or a kV imager mounted orthogonal to the treatment beam. Each image was stored in a file on the imaging workstation. A marker segmentation program opened the image file, determined the marker position in the image, and transferred it to the DMLC tracking program. This program estimated the three-dimensional target position by a single-imager method and adjusted the MLC aperture to the target position. Imaging intervals {Delta}T{sub image} from 150 to 1000 ms were investigated for both kV and MV imaging. After the experiments, the recorded images were synchronized with MLC log files generated by the MLC controller and tracking log files generated by the tracking program. This synchronization allowed temporal analysis of the information flow for each individual image from acquisition to completed MLC adjustment. The synchronization also allowed investigation of the MLC adjustment dynamics on a considerably finer time scale than the 50 ms time resolution of the MLC log files. Results: For {Delta}T{sub image}=150 ms, the total time from image acquisition to completed MLC adjustment was 380{+-}9 ms for MV and 420{+-}12 ms for kV images. The main part of this time was from image acquisition to completed image file writing (272 ms for MV and 309 ms for kV). Image file opening (38 ms), marker segmentation (4 ms), MLC position calculation (16 ms), and MLC adjustment (52 ms) were considerably faster. For {Delta}T{sub image}=1000 ms, the total time from image acquisition to completed MLC adjustment increased to 1030{+-}62 ms (MV) and 1330{+-}52 ms (kV) mainly because of delayed image file writing. The MLC adjustment duration was constant 52 ms ({+-}3 ms) for MLC adjustments below 1.1 mm and increased linearly for larger MLC adjustments. Conclusions: A method for detailed time analysis of each individual real-time position signal for DMLC tracking has been developed and applied to image-based tracking. The method allows identification of the major contributors to latency and therefore a focus for reducing this latency. The method could be an important tool for the reconstruction of the delivered target dose during DMLC tracking as it provides synchronization between target motion and MLC motion.

60 APPLIED LIFE SCIENCES↗

Methods for detecting and correcting inaccurate results in inductively coupled plasma-atomic emission spectrometry

A method for detecting and correcting inaccurate results in inductively coupled plasma-atomic emission spectrometry (ICP-AES). ICP-AES analysis is performed across a plurality of selected locations in the plasma on an unknown sample, collecting the light intensity at one or more selected wavelengths of one or more sought-for analytes, creating a first dataset. The first dataset is then calibrated with a calibration dataset creating a calibrated first dataset curve. If the calibrated first dataset curve has a variability along the location within the plasma for a selected wavelength, errors are present. Plasma-related errors are then corrected by diluting the unknown sample and performing the same ICP-AES analysis on the diluted unknown sample creating a calibrated second dataset curve (accounting for the dilution) for the one or more sought-for analytes. The cross-over point of the calibrated dataset curves yields the corrected value (free from plasma related errors) for each sought-for analyte.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discrete element modeling of switchgrass particles under compression and rotational shear

Switchgrass is a perennial herbaceous plant regarded as a biomass energy crop in the United States for its highadaptability and yield potential. Processing and handling of switchgrass particles are challenging due to the erratic mechanical and flow behavior originating from their intrinsic particulate properties. Here, we present a bonded-sphere discrete element model designed specifically for switchgrass particles. The model simultaneously captures three key particulate features, i.e., fibrous particle shapes, a wide range of particle sizes, and particle deformability. Realistic yet computationally efficient particle shape templates are created based on the image analysis data of switchgrass specimens. A fitting procedure is proposed to ensure both the particle width and length distributions are captured, a unique requirement for fibrous particles. Two full-scale numerical models, i.e., a uniaxial compression model and a Schulze ring shear model, are developed using information fromphysical experiments. The model is calibrated using experimental data of chopped-small switchgrass specimens, and then, is validated using data of chopped-large specimens in both compression and ring-shear tests. Numerical results show that the numerical models capture bulk densities accurately (with an error of 3%) while slightly underestimate the bulk friction angle. Furthermore, an extensive sensitivity analysis reveals that (1) switchgrass particles with rougher edges (due to different processing techniques) exhibit a higher shear strength and a lower flowability; (2) stiffer particles yield a lower bulk density (up to 21% lower) compared to more deformable particles, indicating particle deformability should be incorporated when modeling biomass flow in a preprocessing system.

09 BIOMASS FUELS↗

Influence of ultraviolet irradiation on data retention characteristics in resistive random access memory

With increasing density of memory devices, the issue of generating soft errors by cosmic rays is becoming more and more serious. Therefore, the irradiation resistance of resistance random access memory (ReRAM) to cosmic radiation has to be elucidated for practical use. In this paper, we investigated the data retention characteristics of ReRAM against ultraviolet irradiation with a Pt/NiO/ITO structure. Soft errors were confirmed to be caused by ultraviolet irradiation in both low- and high-resistance states. An analysis of the wavelength dependence of light irradiation on data retention characteristics suggested that electronic excitation from the valence to the conduction band and to the energy level generated due to the introduction of oxygen vacancies caused the errors. Based on a statistically estimated soft error rates, the errors were suggested to be caused by the cohesion and dispersion of oxygen vacancies owing to the generation of electron-hole pairs and valence changes by the ultraviolet irradiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

OVIS 2.0 user%3CU%2B2019%3Es guide.

This document describes how to obtain, install, use, and enjoy a better life with OVIS version 2.0. The OVIS project targets scalable, real-time analysis of very large data sets. We characterize the behaviors of elements and aggregations of elements (e.g., across space and time) in data sets in order to detect anomalous behaviors. We are particularly interested in determining anomalous behaviors that can be used as advance indicators of significant events of which notification can be made or upon which action can be taken or invoked. The OVIS open source tool (BSD license) is available for download at ovis.ca.sandia.gov. While we intend for it to support a variety of application domains, the OVIS tool was initially developed for, and continues to be primarily tuned for, the investigation of High Performance Compute (HPC) cluster system health. In this application it is intended to be both a system administrator tool for monitoring and a system engineer tool for exploring the system state in depth. OVIS 2.0 provides a variety of statistical tools for examining the behavior of elements in a cluster (e.g., nodes, racks) and associated resources (e.g., storage appliances and network switches). It calculates and reports model values and outliers relative to those models. Additionally, it provides an interactive 3D physical view in which the cluster elements can be colored by raw element values (e.g., temperatures, memory errors) or by the comparison of those values to a given model. The analysis tools and the visual display allow the user to easily determine abnormal or outlier behaviors. The OVIS project envisions the OVIS tool, when applied to compute cluster monitoring, to be used in conjunction with the scheduler or resource manager in order to enable intelligent resource utilization. For example, nodes that are deemed less healthy, that is, nodes that exhibit outlier behavior in some variable, or set of variables, that has shown to be correlated with future failure, can be discovered and assigned to shorter duration or less important jobs. Further, applications with fault-tolerant capabilities can invoke those mechanisms on demand, based upon notification of a node exhibiting impending failure conditions, rather than performing such mechanisms (e.g. checkpointing) at regular intervals unnecessarily.

99 GENERAL AND MISCELLANEOUS↗

Characterization of Cameras for the COSMO K-coronagraph

Digital image sensors are ubiquitous in astronomical instrumentation and it is well known that they suffer from issues that must be corrected for data to be scientifically useful. I present discussion on errors resulting from digitization and characterization of nonlinearity and ADC errors of the PhotonFocus MV-D1024E cameras selected for the K-coronagraph of the Coronal Solar Magnetism Observatory. I derive an analytic expression for quantization errors. The MV-D1024E camera has adequate bit depth for which quantization error is not an issue. I show that this is not the case for all cameras, particularly those with deep wells and low read noise. The impact of nonlinearity and ADC errors on science observations of the K-coronagraph is analyzed using a simplified telescope model. Errors caused by the camera ADCs result in systematic errors in the measurement of the polarimetric signal of several times 10{sup −9} B {sub ⊙}, which is about an order of magnitude above the desired sensitivity. I demonstrate a method for post-facto data correction using a lookup table and derive parameters from camera characterization measurements that were made with a lab setup. Nonlinearity is traditionally addressed with a global correction. I show through analysis of calibration data that for the MV-D1024E this correction leaves residual systematic errors after dark and gain correction of up to 1% of the signal. I demonstrate that a pixel-wise correction of nonlinearity reduces the errors to below 0.1%. These corrections are necessary for the K-coronagraph data products to meet the science requirements. They have been implemented in the instrument data acquisition system and data reduction pipeline. While no other instruments besides the K-coronagraph or cameras besides the MV-D1024E are discussed here, the results are illustrative for all instruments and cameras.

79 ASTRONOMY AND ASTROPHYSICS↗

FIVE-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE OBSERVATIONS: DATA PROCESSING, SKY MAPS, AND BASIC RESULTS

We present new full-sky temperature and polarization maps in five frequency bands from 23 to 94 GHz, based on data from the first five years of the Wilkinson Microwave Anisotropy Probe (WMAP) sky survey. The new maps are consistent with previous maps and are more sensitive. The five-year maps incorporate several improvements in data processing made possible by the additional years of data and by a more complete analysis of the instrument calibration and in-flight beam response. We present several new tests for systematic errors in the polarization data and conclude that W-band polarization data is not yet suitable for cosmological studies, but we suggest directions for further study. We do find that Ka-band data is suitable for use; in conjunction with the additional years of data, the addition of Ka band to the previously used Q- and V-band channels significantly reduces the uncertainty in the optical depth parameter, {tau}. Further scientific results from the five-year data analysis are presented in six companion papers and are summarized in Section 7 of this paper. With the five-year WMAP data, we detect no convincing deviations from the minimal six-parameter {lambda}CDM model: a flat universe dominated by a cosmological constant, with adiabatic and nearly scale-invariant Gaussian fluctuations. Using WMAP data combined with measurements of Type Ia supernovae and Baryon Acoustic Oscillations in the galaxy distribution, we find (68% CL uncertainties): {omega} {sub b} h {sup 2} = 0.02267{sup +0.00058} {sub -0.00059}, {omega} {sub c} h {sup 2} = 0.1131 {+-} 0.0034, {omega}{sub {lambda}} = 0.726 {+-} 0.015, n{sub s} = 0.960 {+-} 0.013, {tau} = 0.084 {+-} 0.016, and {delta}{sub R}{sup 2} = (2.445{+-}0.096)x10{sup -9} at k = 0.002 Mpc{sup -1}. From these we derive {sigma}{sub 8} = 0.812 {+-} 0.026, H {sub 0} = 70.5 {+-} 1.3 km s{sup -1} Mpc{sup -1}, {omega} {sub b} = 0.0456 {+-} 0.0015, {omega} {sub c} = 0.228 {+-} 0.013, {omega} {sub m} h {sup 2} = 0.1358{sup +0.0037} {sub -0.0036}, z {sub reion} = 10.9 {+-} 1.4, and t {sub 0} = 13.72 {+-} 0.12 Gyr. The new limit on the tensor-to-scalar ratio is r < 0.22(95%CL), while the evidence for a running spectral index is insignificant, dn{sub s} /dln k = -0.028 {+-} 0.020 (68% CL). We obtain tight, simultaneous limits on the (constant) dark energy equation of state and the spatial curvature of the universe: -0.14 < 1 + w < 0.12(95%CL) and -0.0179 < {omega} {sub k} < 0.0081(95%CL). The number of relativistic degrees of freedom, expressed in units of the effective number of neutrino species, is found to be N {sub eff} = 4.4 {+-} 1.5 (68% CL), consistent with the standard value of 3.04. Models with N {sub eff} = 0 are disfavored at >99.5% confidence. Finally, new limits on physically motivated primordial non-Gaussianity parameters are -9 < f {sup local} {sub NL} < 111 (95% CL) and -151 < f {sup equil} {sub NL} < 253 (95% CL) for the local and equilateral models, respe0013ctive.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimized pulses for the control of uncertain qubits

The construction of high-fidelity control fields that are robust to control, system, and/or surrounding environment uncertainties is a crucial objective for quantum information processing. Using the two-state Landau-Zener model for illustrative simulations of a controlled qubit, we generate optimal controls for π/2 and π pulses and investigate their inherent robustness to uncertainty in the magnitude of the drift Hamiltonian. Next, we construct a quantum-control protocol to improve system-drift robustness by combining environment-decoupling pulse criteria and optimal control theory for unitary operations. By perturbatively expanding the unitary time-evolution operator for an open quantum system, previous analysis of environment-decoupling control pulses has calculated explicit control-field criteria to suppress environment-induced errors up to (but not including) third order from π/2 and π pulses. We systematically integrate this criteria with optimal control theory, incorporating an estimate of the uncertain parameter to produce improvements in gate fidelity and robustness, demonstrated via a numerical example based on double quantum dot qubits. For the qubit model used in this work, postfacto analysis of the resulting controls suggests that realistic control-field fluctuations and noise may contribute just as significantly to gate errors as system and environment fluctuations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FIVE-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE OBSERVATIONS: BEAM MAPS AND WINDOW FUNCTIONS

Cosmology and other scientific results from the Wilkinson Microwave Anisotropy Probe (WMAP) mission require an accurate knowledge of the beam patterns in flight. While the degree of beam knowledge for the WMAP one-year and three-year results was unprecedented for a CMB experiment, we have significantly improved the beam determination as part of the five-year data release. Physical optics fits are done on both the A and the B sides for the first time. The cutoff scale of the fitted distortions on the primary mirror is reduced by a factor of {approx}2 from previous analyses. These changes enable an improvement in the hybridization of Jupiter data with beam models, which is optimized with respect to error in the main beam solid angle. An increase in main-beam solid angle of {approx}1% is found for the V2 and W1-W4 differencing assemblies. Although the five-year results are statistically consistent with previous ones, the errors in the five-year beam transfer functions are reduced by a factor of {approx}2 as compared to the three-year analysis. We present radiometry of the planet Jupiter as a test of the beam consistency and as a calibration standard; for an individual differencing assembly, errors in the measured disk temperature are {approx}0.5%.

79 ASTRONOMY AND ASTROPHYSICS↗