Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Peak cooling load shift capability of a thermal energy storage system integrated with an active insulation system in US climate zones

This study aims to evaluate a thermal energy storage (TES) system integrated with an active insulation system (AIS) to form a TES + AIS integrated wall system as a partition and as a secondary cooling system to shift the peak load and reduce cooling energy consumption. To understand and demonstrate its cooling performance, the TES + AIS integrated wall system was installed in an office building in Oak Ridge, Tennessee. To investigate the effect of the TES + AIS integrated wall system in a typical office building and various climate zones, the US Department of Energy’s prototype office building model was modified to accommodate the proposed system. In this work, results showed that the minimum size of the proposed system to achieve energy savings varies depending on climate conditions. The minimum size of the proposed system for cooling energy saving and shifting peak cooling demand in climate zones 2, 3, and 5 is 29.7 m 2 , whereas it is 44.6 m 2 in zones 4 and 6. By installing the minimum size of the proposed system, 11.3 % to 16.4 % of cooling energy can be shifted during discharge hours in a representative summer day.

25 ENERGY STORAGE↗

Regional Energy Deployment System (ReEDS) Model Documentation: Version 2019

The Regional Energy Deployment System (ReEDS) model is a capacity expansion and dispatch model that is primarily used for the contiguous U.S. electric power sector. The model relies on system-wide least cost optimization to estimate the type and location of future generation and transmission capacity. This document describes details of how the model is formulated, how it functions, and many of the key inputs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Regional Energy Deployment System (ReEDS) Model Documentation (Version 2020)

The Regional Energy Deployment System (ReEDS) model is a capacity expansion and dispatch model that is primarily used for the contiguous U.S. electric power sector. The model relies on system-wide least cost optimization to estimate the type and location of future generation and transmission capacity. This document describes details of how the model is formulated, how it functions, and many of the key inputs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Global Climate Models for Use in Energy Analysis

The interplay between energy, climate, and weather is becoming more complex due to increasing contributions of renewable energy generation, energy storage, electrified end uses, and the increasing frequency of extreme weather events. Energy system analyses commonly rely on meteorological inputs to estimate renewable energy generation and energy demand; however, these inputs rarely represent the estimated impacts of future climate change. Climate models and publicly available climate change datasets can be used for this purpose, but the selection of inputs from the myriad of available models and datasets is a nuanced and subjective process. In this work, we assess datasets from various global climate models (GCMs) from the Coupled Model Intercomparison Project Phase 6 (CMIP6). We present evaluations of their skills with respect to the historical climate and comparisons of their future projections of climate change for two climate change scenarios. We present the results for different climatic and energy system regions and include interactive figures in the accompanying software repository. Previous work has presented similar GCM evaluations, but none have presented variables and metrics specifically intended for comprehensive energy systems analysis including impacts on energy demand, thermal cooling, hydropower, water availability, solar energy generation, and wind energy generation. We focus on GCM output meteorological variables that directly affect these energy system components including the representation of extreme values that can drive grid resilience events. The objective of this work is not to recommend the best climate model and dataset for a given analysis, but instead to provide a reference to facilitate the selection of climate models and scenarios in subsequent work.

14 SOLAR ENERGY↗

Regenerative Fuel Cells: Renewable Energy Storage Devices Based on Neutral Water Input

GRIDS Project: Proton Energy Systems is developing an energy storage device that converts water to hydrogen fuel when excess electricity is available, and then uses hydrogen to generate electricity when energy is needed. The system includes an electrolyzer, which generates and separates hydrogen and oxygen for storage, and a fuel cell which converts the hydrogen and oxygen back to electricity. Traditional systems use acidic membranes, and require expensive materials including platinum and titanium for key parts of the system. In contrast, Proton Energy Systems’ new system will use an inexpensive alkaline membrane and will contain only inexpensive metals such as nickel and stainless steel. If successful, Proton Energy Systems’ system will have similar performance to today’s regenerative fuel cell systems at a fraction of the cost, and can be used to store electricity on the electric grid.

ARPA-E↗

Consumer Guide to Residential Renewable Energy

Learn how installing residential renewable energy systems, such as geothermal heat pumps and wind or solar energy systems, can save energy, lower utility bills, and earn homeowners money. This fact sheet from Energy Saver includes information on how to start planning to install renewable energy systems at home.

residential renewable energy, geothermal heat pump↗

Integrated Hydrogen Energy Storage System (IHESS) for Power Generation (Final Report)

GTI Energy partnered with Praxair Inc., a subsidiary of Linde PLC (Praxair), the Center for Electromechanics at the University of Texas at Austin (CEM), Entergy Corporation (Entergy), Quanta Services (Quanta) and Mitsubishi Heavy Industries (MHI) to perform a feasibility study that determines the economic and technical feasibility of low-carbon hydrogen energy storage integrated with a site-specific fossil fuel asset to decarbonize electricity production using the Integrated Hydrogen Energy Storage System (IHESS). The proposed IHESS concept is novel, as it sought to leverage the existing natural gas infrastructure, hydrogen production and pipelines, existing underground hydrogen storage system and power plants in the Gulf Coast region to reduce carbon emissions and generate lowcarbon electricity. This study has shown that IHESS has a promising commercial outlook as the concept leverages existing natural gas infrastructure assets and hydrogen production and storage that are unique to the Texas gulf coast region. A key hurdle with hydrogen supply and transportation has been capital investment. By storing hydrogen in underground storage and delivering it as a fuel source during peak demand using the existing infrastructure minimizes the capital investment. Regional petrochemical producers who are actively seeking opportunities to reduce costs and lower emissions should find the IHESS concept very appealing.

03 NATURAL GAS↗

High Performance Fuel Cell and Electrolyzer Membrane Electrode Assemblies (MEAs) for Space Energy Storage Systems

Regenerative fuel cells provide a pathway to energy storage system development that are game changers for NASA missions. The fuel cell/ electrolysis MEA performance requirements 0.92 V/ 1.44 V at 200 mA/cm2 can be met. Fuel Cell MEAs have been incorporated into advanced NFT stacks. Electrolyzer stack development in progress. Fuel Cell MEA performance is a strong function of membrane selection, membrane selection will be driven by durability requirements. Electrolyzer MEA performance is catalysts driven, catalyst selection will be driven by durability requirements. Round Trip Efficiency, based on a cell performance, is approximately 65%.

Plastic Encapsulated Microelectronics (PEM)↗

Alkali metal/halide thermal energy storage systems performance evaluation

A pseudoheat-pipe heat transfer mechanism has been demonstrated effective in terms of both total heat removal efficiency and rate, on the one hand, and system isothermal characteristics, on the other, for solar thermal energy storage systems of the kind being contemplated for spacecraft. The selection of appropriate salt and alkali metal substances for the system renders it applicable to a wide temperature range. The rapid heat transfer rate obtainable makes possible the placing of the thermal energy storage system around the solar receiver canister, and the immersing of heat transfer fluid tubes in the phase change salt to obtain an isothermal heat source.

Phillips, W. M.↗

Guest Editorial

Energy Systems Integration (ESI) is the process of coordinating the operation and planning of energy systems across multiple pathways and/or geographical scales to deliver reliable, cost-effective energy services with minimal impact on the environment. Energy systems have evolved from individual systems with little or no dependencies into a complex set of integrated systems at scales that include customers, cities, and regions. This evolution has been driven by political, economic, and environmental objectives. As we try to meet the globally recognized imperative to reduce carbon emissions through the deployment of large renewable energy capacities while also maintaining reliability and competitiveness, flexible energy systems are required. This flexibility can be attained through integrating various systems: by physically linking energy vectors, namely electricity, heat, and fuels; by coordinating these vectors across other infrastructures, namely water, data, and transport; by institutionally coordinating energy markets; and, spatially, by increasing market footprint with granularity all the way down to the customer level. Smart grids and ESI are related, in particular, the coupling between electricity, consumers, data and transport. This special section focuses on the aspects of ESI where electricity is coupled to water, heat and fuels and where this coupling brings challenges and/or opportunities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance and economics of advanced energy conversion systems for coal and coal-derived fuels

The desire to establish an efficient Energy Conversion System to utilize the fossil fuel of the future - coal - has produced many candidate systems. A comparative technical/economic evaluation was performed on the seven most attractive advanced energy conversion systems. The evaluation maintains a cycle-to-cycle consistency in both performance and economic projections. The technical information base can be employed to make program decisions regarding the most attractive concept. A reference steam power plant was analyzed to the same detail and, under the same ground rules, was used as a comparison base. The power plants were all designed to utilize coal or coal-derived fuels and were targeted to meet an environmental standard. The systems evaluated were two advanced steam systems, a potassium topping cycle, a closed cycle helium system, two open cycle gas turbine combined cycles, and an open cycle MHD system.

Corman, J. C.↗

Demonstration of High-Temperature Calcium-Based Thermochemical Energy Storage System for use with Concentrating Solar Power Facilities

Thermochemical energy storage (TCES) systems offer several advantages over sensible heat storage via molten salts for concentrating solar power (CSP) including: energy density, cost, indefinite storage time, and no risk of freezing. SR’s TCES system utilizes a CaO-based carbonation reaction at high temperature in a fixed bed heat exchanger reactor. The SunShot APOLLO project focuses on the validation of the calcium oxide sorbent for capacity, durability, system economics, and demonstration of the system at a small pilot scale, including system control and operation in simulated on-sun conditions, discharging at 720°C. Under phase I SR completed evaluation of the sorbent loaded in a single-channel heat exchanger reactor. The major accomplishments of phase II are: Design, fabrication and commissioning of a 4 kWhth pilot plant (50x capacity increase from previous bench scale) with a closed-loop CO 2 system, and a commercially relevant heat exchange reactor. The heat exchange reactor has been designed with state-of-the-art modeling tools to ensure 1) sufficient lifetime of the Incoloy body and 2) performance of the packed bed reactor will be adequate to meet the milestones. The rest of the pilot system has been designed with off-the shelf components to maximize reliability and cost effectiveness. The system is highly instrumented and capable of time resolved, independent measurements of the heat and mass balances respectively. Major developments in the technoeconomic analysis (TEA) include 1) reduction of the cost of membrane gas storage for the near-term and future systems and 2) integration with liquid metal receivers and particle receivers for higher decarbonation temperatures and pressures which reduced the cost of gas compression and increased system efficiency. The result are three scenarios with costs bases of 21.9 dollars, 14.3 dollars, and 10.9 dollars/kWhth corresponding to a real LCOE of 59, 57, 56 dollars/MWhe, respectively. The basic operations of the energy storage system were demonstrated for carbonation (discharging) and decarbonation (charging) over short time periods. Excellent control of the CO 2 mass balance across the reactor was achieved with mass flow controllers and the basic operation of the level control of the CO 2 gas bladder was achieved. The system was apparently free from leaks and operated continuously for 18 days with no mechanical failures, thus meeting milestone 2.5.5. The major shortcomings of the system had to do with the controls which prevented us from deep cycling and or reaching high cycles. We were unable to decarbonate (charge) the system for more than a few minutes at a time, which was much shorter than the design target of 10 hrs. This issue could not be resolved due to facility availability and contract closure. One major finding is that CaO-based TCES is most cost efficient when charged with HTF (heat transfer fluid) temperatures >850°C to reach the round-trip exergy efficiency and system cost targets which are higher temperatures than those considered for Gen 3 CSP. Many of the balance of plant components do not exist today, however we are encouraged by our findings that in general with more work we are able to reduce the capital cost, for example with the membrane gas storage, which is an innovative component in itself. The CaO-based TCES system has potential to meet the latest SunShot 2030 goals of LCOE at 50 dollars/MWhe with capital costs of <11/kWhth.

14 SOLAR ENERGY↗

Demonstration of High-Temperature Calcium-Based Thermochemical Energy Storage System for use with Concentrating Solar Power Facilities

Thermochemical energy storage (TCES) systems offer several advantages over sensible heat storage via molten salts for concentrating solar power (CSP) including: energy density, cost, indefinite storage time, and no risk of freezing. SR’s TCES system utilizes a CaO-based carbonation reaction at high temperature in a fixed bed heat exchanger reactor. The SunShot APOLLO project focuses on the validation of the calcium oxide sorbent for capacity, durability, system economics, and demonstration of the system at a small pilot scale, including system control and operation in simulated on-sun conditions, discharging at 720°C. Under phase I SR completed evaluation of the sorbent loaded in a single-channel heat exchanger reactor. The major accomplishments of phase II are: Design, fabrication and commissioning of a 4 kWhth pilot plant (50x capacity increase from previous bench scale) with a closed-loop CO 2 system, and a commercially relevant heat exchange reactor. The heat exchange reactor has been designed with state-of-the-art modeling tools to ensure 1) sufficient lifetime of the Incoloy body and 2) performance of the packed bed reactor will be adequate to meet the milestones. The rest of the pilot system has been designed with off-the shelf components to maximize reliability and cost effectiveness. The system is highly instrumented and capable of time resolved, independent measurements of the heat and mass balances respectively. Major developments in the technoeconomic analysis (TEA) include 1) reduction of the cost of membrane gas storage for the near-term and future systems and 2) integration with liquid metal receivers and particle receivers for higher decarbonation temperatures and pressures which reduced the cost of gas compression and increased system efficiency. The result are three scenarios with costs bases of 21.9 dollars, 14.3 dollars, and 10.9 dollars/kWh th corresponding to a real LCOE of 59, 57, 56 dollars/MW he , respectively. The basic operations of the energy storage system were demonstrated for carbonation (discharging) and decarbonation (charging) over short time periods. Excellent control of the CO 2 mass balance across the reactor was achieved with mass flow controllers and the basic operation of the level control of the CO 2 gas bladder was achieved. The system was apparently free from leaks and operated continuously for 18 days with no mechanical failures, thus meeting milestone 2.5.5. The major shortcomings of the system had to do with the controls which prevented us from deep cycling and or reaching high cycles. We were unable to decarbonate (charge) the system for more than a few minutes at a time, which was much shorter than the design target of 10 hrs. This issue could not be resolved due to facility availability and contract closure. One major finding is that CaO-based TCES is most cost efficient when charged with HTF (heat transfer fluid) temperatures >850°C to reach the round-trip exergy efficiency and system cost targets which are higher temperatures than those considered for Gen 3 CSP. Many of the balance of plant components do not exist today, however we are encouraged by our findings that in general with more work we are able to reduce the capital cost, for example with the membrane gas storage, which is an innovative component in itself. The CaO-based TCES system has potential to meet the latest SunShot 2030 goals of LCOE at 50 $/MW he with capital costs of <11/kWh th .

14 SOLAR ENERGY↗

Primary System Test Facility Review

Idaho National Laboratory (INL) is designing a Dynamic Energy Transport and Integration Laboratory (DETAIL) to demonstrate the operation of an integrated energy system as part of supporting research and development needs for the DOE Office of Nuclear Energy Integrated Energy Systems (IES) Program. DETAIL will demonstrate real-time integration with the electrical grid, renewable energy inputs, thermal and electrical energy storage, and energy delivery to an end user. A Thermal Energy Distribution System (TEDS) is being constructed within the DETAIL facility to demonstrate the operation of integrated energy system heat transfer components, thermal energy storage, distribution systems, and instrumentation and control (I&C), which will allow the facility to emulate the distribution of thermal energy to the generation of electrical power, and/or producing non-electrical commodities (e.g., hydrogen). As is the case for other subsystems within DETAIL, TEDS is designed to operate either independently or as a part of an integrated system to demonstrate the operation of integrated components, develop and validate thermal energy transport models and control systems, and study thermal energy inertia and energy storage. In an effort to completely understand how TEDS will integrate with operational plants, data from tests previously run at existing integral system test facilities (IST) will be used to drive the TEDS heater. Alternatively, a real-time data connection would allow steam conditions at the IST to drive the TEDS heater at the same time as having TEDS conditions provide feedback to the IST in terms of steam demand and/or pressure. This integrated testing approach will assess the ability of TEDS to operate during all plant conditions. Three existing integral system test facilities have been reviewed to determine their suitability for demonstrating TEDS capabilities when integrated within the DETAIL. This report summarizes the capabilities of each IST facility and any challenges that must be overcome to meet the operational needs of TEDS and DETAIL.

25 ENERGY STORAGE↗

RESCue Model (RESCue Experiment and Model) [SWR-24-84]

The Renewable Energy and Storage Cybersecurity Research (RESCue) project is a collaborative effort aimed at securing the rapidly growing deployment of transmission-connected hybrid renewable energy systems, consisting of a combination of wind, solar, and/or energy storage equipment, against escalating cyber threats. This project brings together major original equipment manufacturers (OEMs) of wind, solar, and energy storage, along with major asset owners and DOE National Laboratories, to collectively identify cyber threats, assess risks, and develop robust cybersecurity strategies and solutions. The development of hybrid reference architectures has provided comprehensive blueprints for the secure design and integration of hybrid renewable energy systems, accounting for their unique characteristics and interdependencies. Additionally, NREL has created a cyber-resilient design framework that integrates cybersecurity considerations from the start of the system lifecycle, ensuring security is "baked in" from the initial design phase. The research thrusts for the project included (i) development of hybrid reference architectures and (ii) a cyber-resilient design framework for hybrid energy systems. The reference architectures has provided comprehensive blueprints for the secure design and integration of hybrid renewable energy systems, accounting for their unique characteristics and interdependencies. Additionally, NREL has created a cyber-resilient design framework that integrates cybersecurity considerations from the start of the system lifecycle, ensuring security is "baked in" from the initial design phase. A demonstration experiment was developed for one of the architectures using NREL's Cyber Range resources. This experiment configuration, deployable using open-source tools, is provided here in this repository. Additional models were developed for the wind and solar architectures as well, however the configurations for only the Energy Storage scenario are provided here: https://www.nrel.gov/docs/fy24osti/89921.pdf

Hasandka, Adarsh↗