Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Embedded Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Test-particle acceleration in a hierarchical three-dimensional turbulence model

The acceleration of charged particles is relevant to the solar corona over a broad range of scales and energies. High-energy particles are usually detected in concomitance with large energy release events like solar eruptions and flares. Nevertheless, acceleration can occur at smaller scales, characterized by dynamical activity near current sheets. To gain insight into the complex scenario of coronal charged particle acceleration, we investigate the properties of acceleration with a test-particle approach using three-dimensional magnetohydrodynamic (MHD) models. These are obtained from direct solutions of the reduced MHD equations, well suited for a plasma embedded in a strong axial magnetic field, relevant to the inner heliosphere. A multi-box, multiscale technique is used to solve the equations of motion for protons. This method allows us to resolve an extended range of scales present in the system, namely, from the ion inertial scale of the order of a meter up to macroscopic scales of the order of 10 km (1/100th of the outer scale of the system). This new technique is useful to identify the mechanisms that, acting at different scales, are responsible for acceleration to high energies of a small fraction of the particles in the coronal plasma. We report results that describe acceleration at different stages over a broad range of time, length, and energy scales.

79 ASTRONOMY AND ASTROPHYSICS↗

PLC-based Impedance Measurement and Current Injection Response Analysis

Studying and mitigating the vulnerabilities of Programmable Logic Controllers (PLCs) to electromagnetic pulse is important for the reliability of the power system. In this paper, an effective impedance measurement scheme is proposed to estimate the susceptibility of PLCs to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulse Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of PLC.

Qiu, Wei↗

Epidermal Impedance Sensing Sheets for Precision Hydration Assessment and Spatial Mapping

This paper presents a class of hydration monitor that uses ultrathin, stretchable sheets with arrays of embedded impedance sensors for precise measurement and spatially multiplexed mapping. The devices contain miniaturized capacitive electrodes arranged in a matrix format, capable of integration with skin in a conformal, intimate manner due to the overall skin-like physical properties. These “epidermal” systems noninvasively quantify regional variations in skin hydration, at uniform or variable skin depths. Experimental results demonstrate that the devices possess excellent uniformity, with favorable precision and accuracy. Theoretical models capture the underlying physics of the measurement and enable quantitative interpretation of the experimental results. Furthermore, these devices are appealing for applications ranging from skin care and dermatology, to cosmetology and health/wellness monitoring, with the additional potential for combined use with other classes of sensors for comprehensive, quantitative physiological assessment via the skin.

42 ENGINEERING↗

Concept and simulation study of a novel localization method for robotic endoscopic capsules using multiple positron emission markers

Purpose: Over the last decade, wireless capsule endoscope has been the tool of choice for noninvasive inspection of the gastrointestinal tract, especially in the small intestine. However, the latest clinical products have not been equipped with a sufficiently accurate localization system which makes it difficult to determine the location of intestinal abnormalities, and to apply follow-up interventions such as biopsy or drug delivery. In this paper, the authors present a novel localization method based on tracking three positron emission markers embedded inside an endoscopic capsule. Methods: Three spherical {sup 22}Na markers with diameters of less than 1 mm are embedded in the cover of the capsule. Gamma ray detectors are arranged around a patient body to detect coincidence gamma rays emitted from the three markers. The position of each marker can then be estimated using the collected data by the authors’ tracking algorithm which consists of four consecutive steps: a method to remove corrupted data, an initialization method, a clustering method based on the Fuzzy C-means clustering algorithm, and a failure prediction method. Results: The tracking algorithm has been implemented inMATLAB utilizing simulation data generated from the Geant4 Application for Emission Tomography toolkit. The results show that this localization method can achieve real-time tracking with an average position error of less than 0.4 mm and an average orientation error of less than 2°. Conclusions: The authors conclude that this study has proven the feasibility and potential of the proposed technique in effectively determining the position and orientation of a robotic endoscopic capsule.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Perspective on Quantum Computing Applications in Quantum Chemistry Using 25-100 Logical Qubits

The intersection of quantum computing and quantum chemistry represents a promising frontier for achieving quantum utility in domains of both scientific and societal relevance. Owing to the exponential growth of classical resource requirements for simulating quantum systems, quantum chemistry has long been recognized as a natural candidate for quantum computation. This perspective focuses on identifying scientifically meaningful use cases where early fault-tolerant quantum computers, which are considered to be equipped with approximately 25-100 logical qubits, could deliver tangible impact. While recent advances in classical computing have pushed the boundaries of tractable simulations to unprecedented scales, this logical-qubit regime represents the first window where quantum devices can pursue qualitatively distinct strategies, such as polynomial-scaling phase estimation, direct simulation of quantum dynamics, and active-space embedding, that remain challenging for classical solvers, such as multireference charge-transfer and conical-intersection states central to photochemistry and materials design. We highlight near-term opportunities in algorithm and software design, discuss representative chemical problems suited for quantum acceleration, and propose strategic roadmaps and collaborative pathways for advancing practical quantum utility in quantum chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanistic Insights into C–H Borylation of Arenes with Organoiridium Catalysts Embedded in a Microporous Metal–Organic Framework

Organometallic iridium catalysts can be used in conjunction with bispinacolatodiboron (B 2 Pin 2 ) to effect the borylation of a variety of substrates such as arenes, alkanes, heteroarenes, and oxygenates. Recently, efforts have also focused on integrating these catalysts into porous supports, such as metal–organic frameworks (MOFs). While the mechanism of homogeneous borylation systems has been thoroughly investigated experimentally and computationally, analogous studies in MOF-supported iridium catalysts have not been conducted. In this paper, we report the mechanistic investigation of a phenanthroline-iridium catalyst immobilized in the organic linker of Universitetet i Oslo (UiO)-67 (Zr 6 O 4 (OH) 4 (BPDC) 4 (PhenDC) 2 , BPDC = biphenyl-4,4'-dicarboxylate, PhenDC = 1,10-phenanthroline-4,4'-dicarboxylate). By using benzene as a model substrate, variable time normalization analysis (VTNA) of the kinetic data suggested a rate law consistent with zero-order in B 2 Pin 2 , and first-order in arene. A primary kinetic isotope effect (KIE) in the time course of benzene-d 6 borylation also provided complementary information about the role of the arene in the rate-determining step of the reaction. Characterization by techniques such as X-ray absorption spectroscopy (XAS) confirmed the presence of Ir(III), while pair distribution function (PDF) analysis suggested structures containing an Ir–Cl bond, further substantiated by X-ray photoelectron spectroscopy (XPS). Analysis of postcatalysis materials by inductively coupled plasma–optical emission spectroscopy (ICP-OES) revealed low boron accumulation, which may indicate an absence of boron in the resting state of the catalyst. Finally, in comparing borylation of benzene and toluene, a slight selectivity for benzene is observed, which is similar to the analogous homogeneous reaction, indicating the influence of substrate sterics on reactivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PEDOT:PSS-based Multilayer Bacterial-Composite Films for Bioelectronics

Abstract Microbial electrochemical systems provide an environmentally-friendly means of energy conversion between chemical and electrical forms, with applications in wastewater treatment, bioelectronics, and biosensing. However, a major challenge to further development, miniaturization, and deployment of bioelectronics and biosensors is the limited thickness of biofilms, necessitating large anodes to achieve sufficient signal-to-noise ratios. Here we demonstrate a method for embedding an electroactive bacterium, Shewanella oneidensis MR-1, inside a conductive three-dimensional poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) matrix electropolymerized on a carbon felt substrate, which we call a multilayer conductive bacterial-composite film (MCBF). By mixing the bacteria with the PEDOT:PSS precursor in a flow-through method, we maintain over 90% viability of S. oneidensis during encapsulation. Microscopic analysis of the MCBFs reveal a tightly interleaved structure of bacteria and conductive PEDOT:PSS up to 80 µm thick. Electrochemical experiments indicate S. oneidensis in MCBFs can perform both direct and riboflavin-mediated electron transfer to PEDOT:PSS. When used in bioelectrochemical reactors, the MCBFs produce 20 times more steady-state current than native biofilms grown on unmodified carbon felt. This versatile approach to control the thickness of bacterial composite films and increase their current output has immediate applications in microbial electrochemical systems, including field-deployable environmental sensing and direct integration of microorganisms into miniaturized organic electronics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-dimensional reconstruction of the Shigella T3SS transmembrane regions reveals 12-fold symmetry and novel features throughout

Type III secretion systems (T3SSs) mediate bacterial protein translocation into eukaryotic cells, a process essential for virulence of many Gram-negative pathogens. They are composed of a cytoplasmic secretion machinery and a base that bridges both bacterial membranes, into which a hollow, external needle is embedded. When isolated, the latter two parts are termed the 'needle complex'. An incomplete understanding of the structure of the needle complex has hampered studies of T3SS function. To estimate the stoichiometry of its components, we measured the mass of its subdomains by scanning transmission electron microscopy (STEM). We determined subunit symmetries by analysis of top and side views within negatively stained samples in low-dose transmission electron microscopy (TEM). Application of 12-fold symmetry allowed generation of a 21-25-{angstrom} resolution, three-dimensional reconstruction of the needle complex base, revealing many new features and permitting tentative docking of the crystal structure of EscJ, an inner membrane component.

59 BASIC BIOLOGICAL SCIENCES↗

Hadron resonances with a quark core embedded in the continuum

We investigate the excited baryons and mesons which cannot be described in terms of a simple constituent quark model, such as {Lambda}(1405) and X(3872) as a resonance in a coupled channel hadron-hadron (baryon-meson or meson-meson) scattering with a 'bound state embedded in the continuum' (BSEC). For this purpose, we solve the Lippmann-Schwinger equation including a BSEC in the momentum space. This BSEC is introduced by hand, as a state not originated from a simple baryon-meson or meson-meson system. We assume it comes from the three-quark state or quark-anti quark state and show such a picture can describe the {Lambda}(1405) and X(3872) resonances.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

{lambda}(1405) resonance in baryon-meson scattering with a bound state embedded in the continuum

We investigate {lambda}(1405) as a resonance in a coupled-channels baryon-meson ({sigma}{pi}-NK-{lambda}{eta}) scattering with a 'bound state embedded in the continuum' (BSEC). For this purpose, we solve the Lippmann-Schwinger equation including a BSEC with the semirelativistic kinematics in the momentum space. This BSEC is introduced by hand, as a state not originated from a simple baryon-meson system. We assume it comes from the three-quark state. There appears a resonance in the {sigma}{pi} scattering below the NK threshold without introducing a BSEC when the NK channel has a strong attraction, just like the chiral unitary approach. Even if the baryon-meson interaction is weakened by using a lower-momentum cut-off parameter, a resonance also appears around 1405 MeV when a BSEC is introduced. The corresponding peak also has a large width, and the NK scattering length is well reproduced. The interaction whose channel dependence is the same as the one originated from the color-magnetic interaction, where no NK attraction exists, also gives a broad peak with help of a BSEC. In order to reproduce the observed NK scattering length, the calculation including a BSEC seems to be preferable. Our calculation gives an appropriate NK scattering length when the BSEC contribution to the resonance is roughly half that of the NK channel.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

More holographic Berezinskii-Kosterlitz-Thouless transitions

We find two systems via holography that exhibit quantum Berezinskii-Kosterlitz-Thouless (BKT) phase transitions. The first is the ABJM theory with flavor and the second is a flavored (1, 1) little string theory. In each case the transition occurs at nonzero density and magnetic field. The BKT transition in the little string theory is the first example of a quantum BKT transition in (3+1) dimensions. As in the 'original' holographic BKT transition in the D3/D5 system, the exponential scaling is destroyed at any nonzero temperature and the transition becomes second order. Along the way we construct holographic renormalization for probe branes in the ABJM theory and propose a scheme for the little string theory. Finally, we obtain the embeddings and (half of) the meson spectrum in the ABJM theory with massive flavor.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Missile Captive Carry Monitoring using a Capacitive MEMS Accelerometer

Military missiles are exposed to many sources of mechanical vibration that can affect system reliability, safety, and mission effectiveness. One of the most significant exposures to vibration occurs when the missile is being carried by an aviation platform, which is a condition known as captive carry. If the duration of captive carry exposure could be recorded during the missile’s service life, several advantages could be realized. Missiles that have been exposed to durations outside the design envelop could be flagged or screened for maintenance or inspection; lightly exposed missiles could be selected for critical mission applications; and missile allocation to missions could be based on prior use to avoid overuse. The U. S. Army Aviation and Missile Research Development and Engineering Center (AMRDEC) has been developing health monitoring systems to assess and improve reliability of missiles during storage and field exposures. Under the direction of AMRDEC staff, engineers at the Pacific Northwest National Laboratory have developed a Captive Carry Health Monitor (CCHM) for the HELLFIRE II missile. The CCHM is an embedded usage monitoring device installed on the outer skin of the HELLFIRE II missile to record the cumulative hours the host missile has been in captive carry mode and thereby assess the overall health of the missile. This paper provides an overview of the CCHM electrical and package design, describes field testing and data analysis techniques used to identify captive carry, and discusses the potential application of missile health and usage data for real-time reliability analysis and fleet management.

47 OTHER INSTRUMENTATION↗

Optical fiber evanescent wave adsorption sensors for high-temperature gas sensing in advanced coal-fired power plants

Modern advanced energy systems such as coal-fired power plants, gasifiers, or similar infrastructure present some of the most challenging harsh environments for sensors. The power industry would benefit from new, ultra-high temperature devices capable of surviving in hot and corrosive environments for embedded sensing at the highest value locations. For these applications, we are currently exploring optical fiber evanescent wave absorption spectroscopy (EWAS) based sensors consisting of high temperature core materials integrated with novel high temperature gas sensitive cladding materials. Mathematical simulations can be used to assist in sensor development efforts, and we describe a simulation code that assumes a single thick cladding layer with gas sensitive optical constants. Recent work has demonstrated that Au nanoparticle-incorporated metal oxides show a potentially useful response for high temperature optical gas sensing applications through the sensitivity of the localized surface plasmon resonance absorption peak to ambient atmospheric conditions. Hence, the simulation code has been applied to understand how such a response can be exploited in an optical fiber based EWAS sensor configuration. We demonstrate that interrogation can be used to optimize the sensing response in such materials.

01 COAL, LIGNITE, AND PEAT↗

Metal-embedded optical fibers for monitoring pressure or corrosion at high temperatures

A fiber optic sensor and a related method of manufacture are provided. The fiber optic sensor includes an embedded optical fiber contained within a metal diaphragm assembly, where the terminal end of the optical fiber is positioned opposite a diaphragm. The method includes forming a metal-embedded optical fiber by ultrasonic additive manufacturing and securing the metal-embedded optical fiber to a housing having a diaphragm that is opposite of the terminal end of the optical fiber. The sensor can provide extremely accurate pressure measurement at high temperatures and in highly corrosive media. An optical fiber-based pressure sensing system is also provided.

Petrie, Christian M.↗

Optimization of {sup 6}LiF:ZnS(Ag) Scintillator Light Yield Using Geant4

Neutrons provide an effective tool to probe materials structure. Neutron diffraction is a method to determine the atomic and magnetic structure of a material based on neutron scattering. By this method a collimated incident beam of thermal neutrons heat the examined sample and based on the obtained diffraction pattern information on the structure of the material is provided. Research for developing a novel cold neutron detector for Chromatic Analysis Neutron Diffractometer Or Reflectometer (CANDOR) is underway at the NIST center for neutron research. The system unique design is aimed to provide over ten times fold faster analysis of materials than conventional system. In order to achieve the fast analysis a large number of neutron detectors is required. A key design constraint for this detector is the thickness of the neutron sensitive element. This is met using {sup 6}LiF:ZnS(Ag) scintillation material with embedded wavelength shifting (WLS) fibers conducting scintillation light to silicon photomultiplier photo-sensors. The detector sensitivity is determined by both the neutron capture probability ({sup 6}Li density) and the detectable light output produced by the ZnS(Ag) ionization, the latter of which is hindered by the fluorescence absorption of the scintillation light by the ZnS. Tradeoffs between the neutron capture probability, stimulated light production and light attenuation for determining the optimal stoichiometry of the {sup 6}LiF and ZnS(Ag) as well as the volume ratio of scintillator and fiber. Simulations performed using the GEANT4 Monte Carlo package were made in order to optimize the detector design. GEANT4 enables the investigation of the neutron interaction with the detector, the ionization process and the light transfer process following the nuclear process. The series of conversions required for this detector were modelled: - A cold neutron enters the sensor and is captured by {sup 6}Li in the scintillator mixture ({sup 6}Li (n,α) {sup 3}H reaction). The study of investigating the capture process probability for neutron energy of 5.1 meV to 2.27 meV (4 - 6 A) is presented. - Alpha particles and tritons travel for a few microns in the scintillation material (α ∼0.007 mm, T ∼0.04 mm) losing energy and ionizing the ZnS. The mean free path of the two particles in each of the component materials and the complete compound was investigated. - The ionization of the ZnS(Ag) scintillation material produces blue light photons with luminescence wavelength of 450 nm. The amount of light output produced for different grain sizes of ZnS is discussed. - A large portion of the scintillation photons are reabsorbed during their passage through the scintillation material. - The blue photons that reach the WLS fibers are absorbed by fluorescent dye and are re-emitted as green photons, conducted by the fiber to the SiPM photo-sensor. This work presents the CANDOR unique design and its design constrains, the results measured by the ultra-thin {sup 6}LiF:ZnS(Ag)-based neutron detector versus the simulation results for several binder concentrations. The light measurement attenuation results along with the measured stopping power were utilized to predict the sensitivity results of configuration with different ZnS grain size, weight ratios and fibers geometry (number and location). The simulations enable to optimize the final sensor design. This design successfully achieved both the high gamma rejection with a sensitive and accurate neutron event detection of 80 percent. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time Implementation of Grid Code Compliant Grid Edge Energy Management System

Integrated distributed energy resources (DER) in a distribution system need to follow grid codes to avoid violations that result in DER/circuit segment disconnection. To comply with grid code requirements at the grid edge level, network constrained grid edge energy management system (EMS) can be deployed. The objective of grid edge EMS is to provide economic solution for active and reactive power DER setpoints at each dispatch interval and ensure voltage regulation to support secure interconnection of the grid edge segment to the distribution system with multiple inverter based DER units. In this work, real-time simulation of grid code compliant grid edge EMS is deployed in a realistic feeder circuit segment. For real-time simulation, communication between the grid edge EMS and DERs is done exploiting IEC 61850-7-420. It enables interoperability among different DERs and grid edge EMS. No prior art has deployed IEC 61850-7-420 GOOSE communication protocol for grid edge EMS. Conversion of IEC 61850 GOOSE messages to Modbus communication protocol is also performed to communicate with grid edge EMS in commodity-off the shelf embedded boards in this work. The real-time simulation in OPAL-RT real-time digital simulator shows the out-performance of grid edge EMS by reducing the voltage violation in the distribution circuit.

Energy management system↗

Chemical potential in the gravity dual of a 2+1 dimensional system

We study probe D5 branes in D3 brane AdS{sub 5} and AdS{sub 5}-Schwarzschild backgrounds as a prototype dual description of strongly coupled 2+1 dimensional quasiparticles. We introduce a chemical potential through the U(1){sub R} symmetry group, U(1) baryon number, and a U(1) of isospin in the multiflavor case. We find the appropriate D5 embeddings in each case--the embeddings do not exhibit the spontaneous symmetry breaking that would be needed for a superconductor. The isospin chemical potential does induce the condensation of charged meson states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗