Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Satellite Radar Interferometry for Monitoring Ice-Sheet Motion: Application to an Antarctic Ice Stream

As a new means of monitoring the flow velocities and grounding-line positions of ice streams, which are indicators of response of the Antarctic and Greenland ice sheets to climatic change or internal instability, the method of satellite radar interferometry (SRI) is here proposed and applied to the Rutford Ice Stream, Antarctica. The method uses phase comparison of the radar signal obtained for a pair of SAR images taken a few days apart to plot an interferogram which directly displays relative ground motions that have occurred in the time interval between images. The detection limit is about 1.5 mm for vertical motions and about 4 mm for horizontal motions in the radar beam direction. In the Rutford Ice Stream, SRI velocities agree fairly well with earlier ground-truth data over a longitudinal interval of 29 km; the comparison suggests a secular decrease in velocity of about 2 percent from 1978-80 to 1992...

Goldstein, R. M.↗

Satellite Radar Interferometry for Monitoring Ice-Sheet Motion: Application to an Antarctic Ice Stream

As a new means of monitoring the flow velocities and grounding-line positions of ice streams, which are indicators of response of the Antarctic and Greenland ice sheets to climatic change or internal instability, the method of satellite radar interferometry (SRI) is here proposed and applied to the Rutford Ice Stream, Antarctica. The method uses phase comparison of the radar signal obtained for a pair of SAR images taken a few days apart to plot an interferogram which directly displays relative ground motions that have occurred in the time interval between images. The detection limit is about 1.5 mm for vertical motions and about 4 mm for horizontal motions in the radar beam direction. In the Rutford Ice Stream, SRI velocities agree fairly well with earlier ground-truth data over a longitudinal interval of 29 km; the comparison suggests a secular decrease in velocity of about 2 percent from 1978-80 to 1992...

Goldstein, R. M.↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scanning Ultrasonic Spectroscopy System Developed for the Inspection of Composite Flywheels

Composite flywheels are being considered as replacements for chemical batteries aboard the International Space Station. A flywheel stores energy in a spinning mass that can turn a generator to meet power demands. Because of the high rotational speeds of the spinning mass, extensive testing of the flywheel system must be performed prior to flight certification. With this goal in mind, a new scanning system has been developed at the NASA Glenn Research Center for the nondestructive inspection of composite flywheels and flywheel subcomponents. The system uses ultrasonic waves to excite a material and examines the response to detect and locate flaws and material variations. The ultrasonic spectroscopy system uses a transducer to send swept-frequency ultrasonic waves into a test material and then receives the returning signal with a second transducer. The received signal is then analyzed in the frequency domain using a fast Fourier transform. A second fast Fourier transform is performed to examine the spacing of the peaks in the frequency domain. The spacing of the peaks is related to the standing wave resonances that are present in the material because of the constructive and destructive interferences of the waves in the full material thickness as well as in individual layers within the material. Material variations and flaws are then identified by changes in the amplitudes and positions of the peaks in both the frequency and resonance spacing domains. This work, conducted under a grant through the Cleveland State University, extends the capabilities of an existing point-by-point ultrasonic spectroscopy system, thus allowing full-field automated inspection. Results of an ultrasonic spectroscopy scan of a plastic cylinder with intentionally seeded flaws. The result of an ultrasonic spectroscopy scan of a plastic cylinder used as a proof-of-concept specimen is shown. The cylinder contains a number of flat bottomed holes of various sizes and shapes. The scanning system was able to successfully detect all the defects in the material. Ultrasonic spectroscopy results for a second specimen are shown along with a conventional ultrasonic C-scan. The second specimen is a section of a flywheel subcomponent that has a series of drilled holes and notches. This specimen is employed as a defect detection standard to evaluate the various nondestructive evaluation methods under consideration. Scanning results demonstrate the ability of the system to detect flaws on the order of 10 mils in the radial direction and 5 mils in the circumferential direction. Work conducted to date has shown that scanning ultrasonic spectroscopy is a viable tool for the inspection of composite flywheel systems. Ongoing development work is focused on refining the system and scanning parameters for improved resolution and defect detection.

Martin, Richard E.↗

Initial Assessment of Acoustic Source Visibility with a 24-Element Microphone Array in the Arnold Engineering Development Center 80- by 120-Foot Wind Tunnel at NASA Ames Research Center

Measurements of background noise were recently obtained with a 24-element phased microphone array in the test section of the Arnold Engineering Development Center 80- by120-Foot Wind Tunnel at speeds of 50 to 100 knots (27.5 to 51.4 m/s). The array was mounted in an aerodynamic fairing positioned with array center 1.2m from the floor and 16 m from the tunnel centerline, The array plate was mounted flush with the fairing surface as well as recessed in. (1.27 cm) behind a porous Kevlar screen. Wind-off speaker measurements were also acquired every 15 on a 10 m semicircular arc to assess directional resolution of the array with various processing algorithms, and to estimate minimum detectable source strengths for future wind tunnel aeroacoustic studies. The dominant background noise of the facility is from the six drive fans downstream of the test section and first set of turning vanes. Directional array response and processing methods such as background-noise cross-spectral-matrix subtraction suggest that sources 10-15 dB weaker than the background can be detected.

Horne, William C.↗

Detection of Soluble and Fixed NH4+ in Clay Minerals by DTA and IR Reflectance Spectroscopy : A Potential Tool for Planetary Surface Exploration

Nitrogen is an essential element for life. It is the only element among the six major biogenic elements, C, O, S, O, P, H, whose presence in the Martian soil has not been positively and directly established. We describe here a study assessing the ability to detect NH4 in soils by two methods: differential thermal analysis (DTA) and infrared (IR) reflectance spectroscopy. Four standard clay minerals (kaolinite, montmorillonite, illite and attapulgite) and an altered tephra sample from Mauna Kea were treated with NH4 in this study. Samples of the NH4-treated and leached clays were analyzed by DTA and infrared (IR) reflectance spectroscopy to quantify the delectability of soluble and sorbed/fixed NH4. An exotherm at 270-280 C was clearly detected in the DTA curves of NH4-treated (non-leached) samples. This feature is assigned to the thermal decomposition reaction of NH4. Spectral bands observed at 1.56, 2.05, 2.12, 3.06, 3.3, 3.5, 5.7 and 7.0 microns in the reflectance spectra of NH4-treated and leached samples are assigned to the sorbed/fixed ammonium in the clays. The montmorillonite has shown the most intense absorbance due to fixed ammonium among the leached samples in this study, as a result of its high cation sorption capacity. It is concluded that the presence of sorbed or fixed NH4 in clays may be detected by infrared (IR) reflectance or emission spectroscopy. Distinction between soluble and sorbed NH4 may be achieved through the presence or absence of several spectral features assigned to the sorbed NH4 moietyi and, specifically, by use of the 4.2 micrometer feature assigned to solution NH4. Thermal analyses furnish supporting evidence of ammonia in our study through detection of N released at temperatures of 270-330 C. Based on these results it is estimated that IR spectra measured from a rover should be able to detect ammonia if present above 20 mg NH4/g sample in the surface layers. Orbital IR spectra and thermal analyses measured on a rover may be able to detect ammonia in soils as well but at higher abundances. The spectral features at 3.06 and 7.0 microns due to bound NH4 in clays and altered Hawaiian tephra appear to be the most promising for detection by orbital spectrometers. If N species are present on Mars the sedimentary deposits may be the best regions to look for them.

Janice, Bishop↗

Design of robust failure detection filters

An essential aspect of the design of control systems for large, flexible spacecraft is fault tolerance. Because it is anticipated that a large number of sensors and actuators will be required to realize good control over these assemblies, the detection and isolation of component failures cannot be based on direct comparisons among replicated components. Instead, the notion of 'analytic redundancy' must be employed for the FDI function. Unfortunately this makes the FDI function sensitive to modeling errors which are certain to exist in the large space structure problem due to model truncation and parameter uncertainty. This paper addresses the robustness to model error of one method of FDI residual generation - the failure detection filter. Initial designs were found to be extremely sensitive to modeling error. The sources of this sensitivity are analyzed and modifications to the design are suggested. The improved filter is shown to have much better visibility of the failure signatures relative to the background due to modeling error.

San Martin, A. M.↗

Different methods of estimating riverbed sediment grain size diverge at the basin scale

Introduction: The distribution of sediment grain size in streams and rivers is often quantified by the median grain size (D50), a key metric for understanding and predicting hydrologic and biogeochemical function of streams and rivers. Manual D50 measurements are time-consuming and ignore larger grains, while approaches to model D50 based on catchment characteristics may over-generalize and miss site-scale heterogeneity. Machine learning-enabled object detection methods like You Only Look Once (YOLO) provides an alternative that enables estimation of D50 that is faster than manual measurements and more site-specific than predictions based on catchment characteristics. Methods: To understand the potential role of object detection methods for improving understanding of D50, we compared D50 estimates made manually, predicted from catchment characteristics, and using a YOLO-enabled approach across the Yakima River Basin. Results: We found distinct differences between methods for D50 averages and variability, and relationships between D50 estimates and basin characteristics. Discussion: We discuss the advantages and limitations of object detection methods versus current methods, and explore potential future directions to combine D50 methods to better estimate spatiotemporal variation of D50, and improve incorporation into basin-scale models.

grain size distribution↗

Errors in magnetic direction finding due to nonvertical lightning channels

A theory showing that errors in lightning magnetic direction finding due to nonvertical source orientations are minimized by detecting the field from the lowest possible channel section is presented. For 99 cloud-to-ground lightning channels photographed in Arizona, 45 exhibited a bottom few hundred meters within about 8 deg of the vertical, the standard deviation of the distribution of lower-channel tilt angles being about 18 deg. These experimental results, coupled with theory, suggest that if a wideband gated direction finder is used, polarization errors due to nonvertical sources can be kept less than 1 deg for lightning beyond 10 km.

Uman, M. A.↗

Detection of interstellar OH in the far-infrared

Strong absorption lines of OH have been detected at wavelengths of 119.23 and 119.44 microns in the direction of Sgr B2. The lines arise from the 2Pi3/2, J = 5/2-3/2 transitions and imply a column density of N(OH) not less than 2.7 x 10 to the 15th/sq cm. The LSR Doppler velocity of the absorption features is close to zero; this suggests that material is being seen from both the +62 km/s and -90 km/s clouds at radio wavelengths. In addition, the detection of the same two lines in emission from the shocked region of the Orion Nebula has been made possible. The indicated intensity of these lines is 1.6 x 10 to the -17th W/sq cm, which implies a column density of shocked OH of about 3.6 x 10 to the 15th/sq cm.

Storey, J. W. V.↗

NASA Tech Briefs, December 2007

Topics include: Ka-Band TWT High-Efficiency Power Combiner for High-Rate Data Transmission; Reusable, Extensible High-Level Data-Distribution Concept; Processing Satellite Imagery To Detect Waste Tire Piles; Monitoring by Use of Clusters of Sensor-Data Vectors; Circuit and Method for Communication Over DC Power Line; Switched Band-Pass Filters for Adaptive Transceivers; Noncoherent DTTLs for Symbol Synchronization; High-Voltage Power Supply With Fast Rise and Fall Times; Waveguide Calibrator for Multi-Element Probe Calibration; Four-Way Ka-Band Power Combiner; Loss-of-Control-Inhibitor Systems for Aircraft; Improved Underwater Excitation-Emission Matrix Fluorometer; Metrology Camera System Using Two-Color Interferometry; Design and Fabrication of High-Efficiency CMOS/CCD Imagers; Foam Core Shielding for Spacecraft CHEM-Based Self-Deploying Planetary Storage Tanks Sequestration of Single-Walled Carbon Nanotubes in a Polymer PPC750 Performance Monitor Application-Program-Installer Builder Using Visual Odometry to Estimate Position and Attitude Design and Data Management System Simple, Script-Based Science Processing Archive Automated Rocket Propulsion Test Management Online Remote Sensing Interface Fusing Image Data for Calculating Position of an Object Implementation of a Point Algorithm for Real-Time Convex Optimization Handling Input and Output for COAMPS Modeling and Grid Generation of Iced Airfoils Automated Identification of Nucleotide Sequences Balloon Design Software Rocket Science 101 Interactive Educational Program Creep Forming of Carbon-Reinforced Ceramic-Matrix Composites Dog-Bone Horns for Piezoelectric Ultrasonic/Sonic Actuators Benchtop Detection of Proteins Recombinant Collagenlike Proteins Remote Sensing of Parasitic Nematodes in Plants Direct Coupling From WGM Resonator Disks to Photodetectors Using Digital Radiography To Image Liquid Nitrogen in Voids Multiple-Parameter, Low-False-Alarm Fire-Detection Systems Mosaic-Detector-Based Fluorescence Spectral Imager Plasmoid Thruster for High Specific-Impulse Propulsion Analysis Method for Quantifying Vehicle Design Goals Improved Tracking of Targets by Cameras on a Mars Rover Sample Caching Subsystem Multistage Passive Cooler for Spaceborne Instruments GVIPS Models and Software Stowable Energy-Absorbing Rocker-Bogie Suspensions

Source record↗

Results from the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

The GCMS was part of the instrument complement on the Cassini-Huygens Probe to measure in situ the chemical composition of the atmosphere during the probe descent and coupled with the Aerosol Collector Pyrolyser (ACP) experiment by serving as detector for the pyrolization products to determine the composition of the aerosol particles. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns, a chemical scrubber and a hydrocarbon enrichment cell. The GCMS gas inlet was heated to prevent condensation, and to evaporate volatiles from the surface after impact. The GCMS collected data from an altitude of 146 km to ground impact. The Probe and the GCMS survived impact and collected data for 1 hour and 9 minutes on the surface. Mass spectra were collected during descent and on the ground over a range of m/z from 2 to 141. The major constituents of the lower atmosphere were confirmed to be NP and CH4. The methane mole fraction was uniform in the stratosphere. It increased below the tropopause, at about 32 km altitude, monotonically toward the surface, reaching a plateau at about 8 km at a level near saturation. After surface impact a steep increase of the methane signal was observed, suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. The measured mole fraction of Ar-40 is 4.3 x 10(exp-5) and of Ar-36 is 2.8 x 10(exp -7). The other primordial noble gases were below mole fraction. The isotope ratios of C-12/C-13 determined from methane measurements are 82.3 and of N-14/N-15 determined from molecular nitrogen are 183. The D/H isotope ratio determined from the H2 and HD measurements is 2.3 x l0(exp -4). Carbon dioxide, ethane, acetylene and cyanogen were detected evaporating from the surface in addition to methane.

Niemann, Hasso B.↗

Coronal Dynamics and Complete Flare Energy Budget for the M Dwarf AD Leo

This grant supported the observing and data analysis for FUSE Cycle 3 project C114 to observe the flare star AD Leo for 50 ksec coordinated with HST (Hubble Space Telescope) STIS ultraviolet spectroscopy and Chandra X-ray spectroscopy. Unfortunately, it was impossible to obtain the planned FUSE observations because AD Leo is a low declination target (delta approximately 20 degrees) and was rendered unobservable by restrictions in the sky coverage for FUSE observations. In April 2002 another M dwarf star, EV Lac, which is at significantly higher declination, was substituted for this project. EV Lac was observed by FUSE for a cumulative exposure of 35 ksec on 2002 July 1. The observation used the large LWRS aperture and collected data in time-tagged mode. The LWRS aperture is large enough that the target should remain within the aperture despite the normal level of pointing jitter and target drift experienced during FUSE observing. Our examination of the stellar signal showed that the target was well within the aperture throughout the observation. The data were split into night-time and day-time data so that the effects of airglow emission were recognizable. No obvious flaring, the primary science objective, was detected during the observation. The only stellar lines detected are 0 VI 1031.9, 1037.6 Angstrom, and the C III 1175 Angstrom, UV multiplet and the 977 Angstrom, resonance line. A comparison of the day-time and night-time spectra show that the 0 VI lines and the C III intersystem multiplet are unaffected by airglow features. The day-time data 977 Angstrom profile shows the presence of significant scattered solar C III photons, which should not be present in the night time spectrum. Emission fluxes for these lines were measured by direct summation of the emission lines. No continuum signal was detected in the region of these lines. The cleanest emission line profiles are for the O VI lines and we performed Gaussian fitting for these profiles. Both lines are clearly skewed with the emission peak shifted shortward of the line centroid and with emission extending further in the longward wing than for the shortward wing. A single Gaussian fits the 1032 Angstrom line profile reasonably and gives a line flux similar to that from direct integration with a line width (FWHM) of 0.16 Angstrom, (46 kilometers per second).

Brown, Alexander↗

Processing Images of Craters for Spacecraft Navigation

A crater-detection algorithm has been conceived to enable automation of what, heretofore, have been manual processes for utilizing images of craters on a celestial body as landmarks for navigating a spacecraft flying near or landing on that body. The images are acquired by an electronic camera aboard the spacecraft, then digitized, then processed by the algorithm, which consists mainly of the following steps: 1. Edges in an image detected and placed in a database. 2. Crater rim edges are selected from the edge database. 3. Edges that belong to the same crater are grouped together. 4. An ellipse is fitted to each group of crater edges. 5. Ellipses are refined directly in the image domain to reduce errors introduced in the detection of edges and fitting of ellipses. 6. The quality of each detected crater is evaluated. It is planned to utilize this algorithm as the basis of a computer program for automated, real-time, onboard processing of crater-image data. Experimental studies have led to the conclusion that this algorithm is capable of a detection rate >93 percent, a false-alarm rate <5 percent, a geometric error <0.5 pixel, and a position error <0.3 pixel.

Cheng, Yang↗

Constraints on directionality effect of nuclear recoils in a liquid argon time projection chamber

The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils produced in a target material from the WIMP elastic scattering. The experimental identification of the direction of the WIMP-induced nuclear recoils is a crucial asset in this field, as it enables unmistakable modulation signatures for dark matter. The Recoil Directionality (ReD) experiment was designed to probe for such directional sensitivity in argon dual-phase time projection chambers (TPC), that are widely considered for current and future direct dark matter searches. The TPC of ReD was irradiated with neutrons at the INFN Laboratori Nazionali del Sud. Data were taken with nuclear recoils of known directions and kinetic energy of 72 keV, which is within the range of interest for WIMP-induced signals in argon. The direction-dependent liquid argon charge recombination model by Cataudella et al. was adopted and a likelihood statistical analysis was performed, which gave no indications of significant dependence of the detector response to the recoil direction. The aspect ratio R of the initial ionization cloud is $R < 1.072$ with 90 % confidence level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Breath analysis by ultra-sensitive broadband laser spectroscopy detects SARS-CoV-2 infection

Rapid testing is essential to fighting pandemics such as coronavirus disease 2019 (COVID-19), the disease caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Exhaled human breath contains multiple volatile molecules providing powerful potential for non-invasive diagnosis of diverse medical conditions. We investigated breath detection of SARS-CoV-2 infection using cavity-enhanced direct frequency comb spectroscopy (CE-DFCS), a state-of-the-art laser spectroscopic technique capable of a real-time massive collection of broadband molecular absorption features at ro-vibrational quantum state resolution and at parts-per-trillion volume detection sensitivity. Using a total of 170 individual breath samples (83 positive and 87 negative with SARS-CoV-2 based on reverse transcription polymerase chain reaction tests), we report excellent discrimination capability for SARS-CoV-2 infection with an area under the receiver-operating-characteristics curve of 0.849(4). Our results support the development of CE-DFCS as an alternative, rapid, non-invasive test for COVID-19 and highlight its remarkable potential for optical diagnoses of diverse biological conditions and disease states.

60 APPLIED LIFE SCIENCES↗

Direct Imaging and Spectroscopy of Exoplanetary Systems with the JWST Early Release Science Program

The direct characterization of exoplanetary systems with high contrast imaging is among the highest priorities for the broader exoplanet community. As large space missions will be necessary for detecting and characterizing exo-Earth twins, developing the techniques and technology for direct imaging of exoplanets is a driving focus for the community. For the first time, JWST will directly observe extrasolar planets at mid-infrared wavelengths beyond 5 μm, deliver detailed spectroscopy revealing much more precise chemical abundances and atmospheric conditions, and provide sensitivity to analogs of our solar system ice-giant planets at wide orbital separations, an entirely new class of exoplanet. However, in order to maximise the scientific output over the lifetime of the mission, an exquisite understanding of the instrumental performance of JWST is needed as early in the mission as possible. In this paper, we describe our 55-hour Early Release Science Program that will utilize all four JWST instruments to extend the characterisation of planetary mass companions to ∼15-20 μm as well as image a circumstellar disk in the mid-infrared with unprecedented sensitivity. Our program will also assess the performance of the observatory in the key modes expected to be commonly used for exoplanet direct imaging and spectroscopy, optimize data calibration and processing, and generate representative datasets that will enable a broad user base to effectively plan for general observing programs in future cycles.

Michael W McElwain↗

Robust Kalman filter design for predictive wind shear detection

Severe, low-altitude wind shear is a threat to aviation safety. Airborne sensors under development measure the radial component of wind along a line directly in front of an aircraft. In this paper, optimal estimation theory is used to define a detection algorithm to warn of hazardous wind shear from these sensors. To achieve robustness, a wind shear detection algorithm must distinguish threatening wind shear from less hazardous gustiness, despite variations in wind shear structure. This paper presents statistical analysis methods to refine wind shear detection algorithm robustness. Computational methods predict the ability to warn of severe wind shear and avoid false warning. Comparative capability of the detection algorithm as a function of its design parameters is determined, identifying designs that provide robust detection of severe wind shear.

Stratton, Alexander D.↗