Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct Simulation Monte Carlo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Kinetic Monte Carlo simulations of excitation density dependent scintillation in CsI and CsI(Tl)

Nonlinear quenching of electron-hole pairs in the denser regions of ionization tracks created by γ-ray and high-energy electrons is a likely cause of the light yield nonproportionality of many inorganic scintillators. Therefore, kinetic Monte Carlo (KMC) simulations were carried out to investigate the scintillation properties of pure and thallium-doped CsI as a function of electron-hole pair density. The availability of recent experimental data on the excitation density dependence of the light yield of CsI following ultraviolet excitation allowed for an improved parameterization of the interactions between self-trapped excitons (STE) in the KMC model via dipole-dipole Förster transfer. The KMC simulations reveal that nonlinear quenching occurs very rapidly (within a few picoseconds) in the early stages of the scintillation process. In addition, the simulations predict that the concentration of thallium activators can affect the extent of nonlinear quenching as it has a direct influence on the STE density through STE dissociation and electron scavenging. This improved model will enable more realistic simulations of the nonproportional γ-ray and electron response of inorganic scintillators.

Wang, Zhiguo↗

Vapor-liquid Coexistence Curves for Methanol and Methane using Dispersion-Corrected Density Functional Theory

First principles Monte Carlo simulations in the Gibbs and isobaric-isothermal ensembles were performed to map the vapor-liquid coexistence curves (VLCC) of methanol and methane described by Kohn-Sham density functional theory using the Becke-Lee-Yang-Parr (BLYP) exchange and correlation functionals with the Grimme correction term for dispersive (D2) interactions. The simulations indicate that the BLYP-D2 description underpredicts the saturated vapor densities and overpredicts the saturated liquid densities and critical and boiling temperatures for both compounds. Although the deviations are quite large, these results present a significant improvement over the BLYP functional without the correction term which misses the experimental results by a larger extent in the opposite direction. With the D2 correction, an increase in the basis set does not lead to significant changes in the VLCC properties. This work was supported by the US Department of Energy, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences & Biosciences. Pacific Northwest National Laboratory is operated by Battelle for the US Department of Energy.

03 NATURAL GAS↗

Systematic hierarchical coarse-graining with the inverse Monte Carlo method

We outline our coarse-graining strategy for linking micro- and mesoscales of soft matter and biological systems. The method is based on effective pairwise interaction potentials obtained in detailed ab initio or classical atomistic Molecular Dynamics (MD) simulations, which can be used in simulations at less accurate level after scaling up the size. The effective potentials are obtained by applying the inverse Monte Carlo (IMC) method [A. P. Lyubartsev and A. Laaksonen, Phys. Rev. E 52(4), 3730–3737 (1995)] on a chosen subset of degrees of freedom described in terms of radial distribution functions. An in-house software package MagiC is developed to obtain the effective potentials for arbitrary molecular systems. In this work we compute effective potentials to model DNA-protein interactions (bacterial LiaR regulator bound to a 26 base pairs DNA fragment) at physiological salt concentration at a coarse-grained (CG) level. Normally the IMC CG pair-potentials are used directly as look-up tables but here we have fitted them to five Gaussians and a repulsive wall. Results show stable association between DNA and the model protein as well as similar position fluctuation profile.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Space Launch System Implementation of Adaptive Augmenting Control

Given the complex structural dynamics, challenging ascent performance requirements, and rigorous flight certification constraints owing to its manned capability, the NASA Space Launch System (SLS) launch vehicle requires a proven thrust vector control algorithm design with highly optimized parameters to robustly demonstrate stable and high performance flight. On its development path to preliminary design review (PDR), the stability of the SLS flight control system has been challenged by significant vehicle flexibility, aerodynamics, and sloshing propellant dynamics. While the design has been able to meet all robust stability criteria, it has done so with little excess margin. Through significant development work, an adaptive augmenting control (AAC) algorithm previously presented by Orr and VanZwieten, has been shown to extend the envelope of failures and flight anomalies for which the SLS control system can accommodate while maintaining a direct link to flight control stability criteria (e.g. gain & phase margin). In this paper, the work performed to mature the AAC algorithm as a baseline component of the SLS flight control system is presented. The progress to date has brought the algorithm design to the PDR level of maturity. The algorithm has been extended to augment the SLS digital 3-axis autopilot, including existing load-relief elements, and necessary steps for integration with the production flight software prototype have been implemented. Several updates to the adaptive algorithm to increase its performance, decrease its sensitivity to expected external commands, and safeguard against limitations in the digital implementation are discussed with illustrating results. Monte Carlo simulations and selected stressing case results are shown to demonstrate the algorithm's ability to increase the robustness of the integrated SLS flight control system.

VanZwieten, Tannen S.↗

An updated estimate of the Mu2e experiment sensitivity

The Mu2e experiment at Fermilab will search for the conversion of a negative muon into an electron inside the field of a nucleus. This process does not conserve charged-lepton flavour and is heavily suppressed in the Standard Model (SM), with a branching ratio < 10-50. Any evidence of it would be an undeniable evidence of new physics beyond the SM. The project sets out to achieve a single event sensitivity of $\sim 3 × 10^{-17}$ on the ratio between the probability for a conversion of a negative muon into an electron and the one for a muon capture by the nucleus. Such a sensitivity would represent a 4 orders of magnitude improvement on the previous upper limit for the process, making possible to test predictions of different extensions of the SM. Mu2e uses three superconducting solenoids to produce and measure the muon conversions. In the first solenoid, the Production Solenoid, pions and kaons are produced, together with other secondary products, by 8 GeV kinetic energy proton interactions in a tungsten target. A gradient magnetic field is specifically designed to direct low momentum particles into the Transport Solenoid, an S-shaped magnet that filters out particles with unwanted charge and momentum. Muons, produced by pion and kaon decays, finally reach the aluminum Stopping Target in the Detector Solenoid, where they eventually stop and convert. The result of the conversion process is a monochromatic electron of ~105 MeV/c momentum. The Detector Solenoid also hosts the two main detectors: a straw tube tracker and two CsI calorimeter disks, both providing measurement of event kinematics. A germanium detector and a LaBr crystal are located downstream of the Detector Solenoid to measure the X and gamma rays produced by the muon captures in the Stopping Target. A veto system of scintillators covering the Detector Solenoid and half of the Transport Solenoid is used to identify and reject cosmic rays interactions. With respect to the initial project, the Mu2e running plan has evolved to a staged configuration with 2 years at reduced intensity before the 2025 accelerator shutdown for the neutrino beam upgrade and 2 or 3 years at full intensity after that. This, together with geometry changes and a better knowledge of detector performances obtained by the first slice tests, has required a full revision of the signal over background selection that is the subject of this thesis. In order to achieve a new estimate of Mu2e sensitivity, the simulation of the data corresponding to the first 2 years of data acquisition has been performed. This includes both conversion electrons (CE) and the main sources of background: cosmics, decay-in orbits (DIO), radiative pion captures (RPC) and antiprotons. The characteristics of the signal and of the main backgrounds have been studied to define the best selection variables for CE. A special effort has been devoted to the evaluation of the antiproton background. The lack of experimental data for antiproton production cross section makes the systematic uncertainty on this background significant. A new parameterization of the cross section has been developed to fit the existing data and to provide a more reliable estimate of the systematic uncertainty by comparing the results of the old and the new model. A special effort has been devoted to the optimization of the antiprotons Monte Carlo generator. This study has also revealed that the dominant component within this background is represented by antiprotons produced in the opposite direction with respect to the Transport Solenoid entrance and then redirected to it by back-scattering processes in the Production Target. This ultimately highlights the sensitivity of the background estimate to the G4 handling of antiproton interactions in the 1 to 3 GeV/c momentum range. Finally, the final experimental sensitivity has been studied. The momentum and time selection have been optimized to obtain the 5-sigma discovery reach or, in case of no signal, the upper limit on conversion probability. The results confirm that, in the firs t two years of data taking, Mu2e will be able to improve the current experimental sensitivity for muon-to-electron conversion in an atomic field by more than 3 order of magnitudes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modernizing the active neutron collar poison rod correction using simulations to enhance PWR fresh fuel verification

The declared inventory of 235 U in fresh, low enriched uranium, nuclear fuel assemblies is routinely verified by nuclear safeguards inspectorates using the UNCL (Uranium Neutron Collar – Light Water Reactor Fuel) nondestructive assay instrument. The trend in modern fuels is towards higher initial enrichment, which in turn requires a larger number of burnable poison pins with higher Gadolinia concentration to hold down the initial reactivity. UNCL assay error for modern fuel assemblies typically exceeds 10%. The traditional algorithm used to correct the response for burnable poison content needs revision to achieve accuracy comparable to the $\sigma_\text{R}$ of 4.5% expected for poison-free assemblies. Here we review the problem and use a large set of 287 Monte Carlo simulations based on an experimentally benchmarked model corresponding to the 16×16 PWR array used in Brazilian Angra type II and III fuel. Simulated relative responses are used to evaluate the functional form of the poison correction and determine parameters optimal for 16×16 PWR assemblies. This update is conducted using between 4–24 Gadolinia pins ranging 2–11 wt% Gd 2 O 3 with assemblies having mean enrichments ranging 2.5%–5%. Experimental validation of the updated coefficients using seven measurements shows bias is reduced by an order of magnitude and $\sigma_\text{R}$R reduced from 10% to less than 2%. Two updated sets of coefficients are provided, the most accurate of which is directly useable in the existing analysis code (INCC) in use by inspectorate at fuel fabrication facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beyond Magic Barrels: Digital manufacturing for crystallization, process development and optimization of explosive materials: Part II Resveratrol Exemplar

This SAND report summarizes work supported by an Engineering Sciences Research Foundation (ESRF) Lab Directed Research and Development (LDRD) project entitled “Beyond Magic Barrels: Digital manufacturing for crystallization, process development and optimization of explosive materials.” This SAND report is written in two parts with Part 1 discusses recrystallization of our explosive exemplar and Part 2 summarizing our work with recrystallization of resveratrol. We have studied resveratrol recrystallization with a multiscale approach combining experiments, modeling and simulation. At the single crystal scale, microscopy experiments illuminate crystal time-dependent growth rates using advanced image analysis. Bench scale experiments were carried out to look at growth of multiple particles in a small reactor creating thousands of particles and analyzing the results with microscopy and μCT. For the modeling we combine kinetic Monte Carlo (kMC) models with subscale information from density functional theory (DFT) or molecular dynamics. This work is discussed in Part 1 and can also be found in a paper from the project discussing a coarse-grained kMC model specifically developed for resveratrol. For well-mixed systems, we have population balance equations (PBE) linked with species mass conservation forming a set of ordinary differential equations that can be solved quickly. For more complicated geometries, such as the vat crystallization used throughout the complex, a coupled computational fluid dynamic (CFD)/PBE method was developed to account for gradients in temperature and concentration and differences in crystallization rates throughout the domain. These simulations are more complex and require high performance computing. We present results for two cases: 5% seed fast cool with parameters fit to the well-mixed case and 5% seed slow cool using the same parameters. We show reasonable agreement with experiments though are particles are significantly larger than the experiments.

36 MATERIALS SCIENCE↗

A NEW METHOD TO DIRECTLY MEASURE THE JEANS SCALE OF THE INTERGALACTIC MEDIUM USING CLOSE QUASAR PAIRS

Although the baryons in the intergalactic medium (IGM) trace dark matter fluctuations on megaparsec scales, on smaller scales ∼100 kpc, fluctuations are suppressed because the finite temperature gas is pressure supported against gravity, analogous to the classical Jeans argument. This Jeans filtering scale, which quantifies the small-scale structure of the IGM, has fundamental cosmological implications. First, it provides a thermal record of heat injected by ultraviolet photons during cosmic reionization events, and thus constrains the thermal and reionization history of the universe. Second, the Jeans scale determines the clumpiness of the IGM, a critical ingredient in models of cosmic reionization. Third, it sets the minimum mass scale for gravitational collapse from the IGM, and hence plays a pivotal role in galaxy formation. Unfortunately, it is extremely challenging to measure the Jeans scale via the standard technique of analyzing purely longitudinal Lyα forest spectra, because the thermal Doppler broadening of absorption lines along the line-of-sight, is highly degenerate with Jeans smoothing. In this work, we show that the Jeans filtering scale can be directly measured by characterizing the coherence of correlated Lyα forest absorption in close quasar pairs, with separations small enough ∼100 kpc to resolve it. We present a novel technique for this purpose, based on the probability density function (PDF) of phase angle differences of homologous longitudinal Fourier modes in close quasar pair spectra. A Bayesian formalism is introduced based on the phase angle PDF, and Markov Chain Monte Carlo techniques are used to characterize the precision of a hypothetical Jeans scale measurement, and explore degeneracies with other thermal parameters governing the IGM. A semi-analytical model of the Lyα forest is used to generate a large grid (500) of thermal models from a dark matter only simulation. Our full parameter study indicates that a realistic sample of only 20 close quasar pair spectra can pinpoint the Jeans scale to ≅ 5% precision, independent of the amplitude T{sub 0} and slope γ of the temperature-density relation of the IGM T=T{sub 0}(ρ/ ρ-bar ){sup γ-1}. This exquisite sensitivity arises because even long-wavelength one-dimensional Fourier modes ∼10 Mpc, i.e., two orders of magnitude larger than the Jeans scale, are nevertheless dominated by projected small-scale three-dimensional (3D) power. Hence phase angle differences between all modes of quasar pair spectra actually probe the shape of the 3D power spectrum on scales comparable to the pair separation. We show that this new method for measuring the Jeans scale is unbiased and is insensitive to a battery of systematics that typically plague Lyα forest measurements, such as continuum fitting errors, imprecise knowledge of the noise level and/or spectral resolution, and metal-line absorption.

79 ASTRONOMY AND ASTROPHYSICS↗

Bidirectional reflectance of oceanic waters: A comparison of modeled and measured upward radiance fields

The bidirectional reflectance of oceanic waters is conveniently described in a normalized way by forming the ratio of the upwelling irradiance E(sub u) to any upwelling radiance L(sub u)(theta prime, phi). This ratio, Q (theta prime, theta(sub 0), (phi(sub 0) - phi), where theta prime, phi are the nadir and azimuth angles for the upward radiance and theta(sub 0), phi(sub 0) are the zenith and azimuth angles of the Sun, has been determined from measurements at sea and computed via Monte Carlo simulations using the inherent optical properties measured in the field and appropriate boundary conditions (clear sky, no wind, varying Sun angle). Experimental ad computed Q values are in excellent agreement. This successful comparison confirms the importance of the bidirectional character of ocean reflectance, already pointed out from a purely numerical approach without field validation, and corroborates the extended range of the Q variations. The later point is of importance when interpreting the marine signals detected by an ocean color satellite-borne sensor. The validation is extended by considering the historical data for the radiance distributions in Lake Pend Oreille determined at various depths. The closure issue in ocean optics is examined by solving the direct problem of radiative transfer and through a model-data comparison in terms of radiance field.

Morel, Andre↗

Energy Calibration of the Scintillating Optical Fiber Calorimeter Chamber (SOFCAL)

The Scintillating Optical Fiber Calorimeter (SOFCAL) detector is designed to make direct measures of the primary cosmic ray spectrum from -200 GeV/amu - 20 TeV/amu. The primary particles are resolved into groups according to their charge (p, He, CNO, Medium Z, Heavy Z) using both active and passive components integrated into the detector. The principal part of SOFCAL is a thin ionization calorimeter that measures the electromagnetic cascades that result from these energetic particles interacting in the detector. The calorimeter is divided into two sections: a thin passive emulsion/x-ray film calorimeter, and a fiber calorimeter that uses crossing layers of small scintillating optical fibers to sample the energy deposition of the cascades. The energy determination is made by fitting the fiber data to transition curves generated by Monte Carlo simulations. The fiber data must first be calibrated using the electron counts from the emulsion plates in the calorimeter for a small number of events. The technique and results of this calibration will be presented together with samples of the data from a balloon flight.

Christl, M. C.↗

Monte Carlo simulation of the passage of $\gamma$-rays and $\alpha$-particles in CsI

In this work, theoretical and computational methods for simulating the creation of ionization tracks by fast ions in solids were applied to the passage of a-particles in CsI, an inorganic scintillator commonly used for radiation detection. The methods were implemented in a Monte Carlo program to simulate the interaction of $\alpha$-particles, with incident energies of up to 1 MeV, with CsI. The simulations followed the fate of individual electron-hole pairs and thus allowed for a detailed description of the microscopic structure of ionization tracks created by incident radiation. Simulations were also performed with $\gamma$-rays of the same energy to compare and contrast the ionization tracks obtained with both types of particle. Intrinsic properties such as the mean energy per electron-hole pair, Fano factor, maximum theoretical light yield, and spatial distributions of electron-hole pairs were computed for both $\alpha$-particles and $\gamma$-rays. $\alpha$-particles created cylindrical tracks that were initially aligned with the incident direction and with initial radii of a few nanometers, whereas $\gamma$-rays showed significant scattering, resulting in probability distributions with lower intensities and much greater radial extents.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Directional Canopy Emissivity Model Based on Spectral Invariants

A new directional canopy emissivity model (CE-P) based on spectral invariants is proposed in this study. First, we prove the existence of the spectral invariant properties in the thermal infrared (TIR) band using a Monte Carlo model. Based on it, the equation of the new model is derived from the perspective of absorption. In this expression, single-scattering and multiscattering effects are separated analytically in the TIR band. We find that the overall contribution of multiple scatterings is less than 0.005 when the component emissivities are over 0.90, and the overall contribution decreases with increasing leaf or soil emissivity. Furthermore, the new model can avoid the logical difficulty encountered when using the traditional cavity effect factor to simulate the emissivity of a sparse vegetation canopy. The results of 4SAIL and Discrete Anisotropic Radiative Transfer (DART) are selected to do cross validation. The CE-P can achieve a high accuracy compared with 4SAIL and DART, with an absolute bias less than 0.002 when the leaf (soil) emissivity is equal to 0.98 (0.94). Four widely used analytical models are selected for comparison. The resulting accuracies of these models are ordered from CE-P to REN15, FR97, FR02, and VALOR96 with the most serious error up to 0.002, 0.002, 0.007, 0.013, and 0.014, respectively. Finally, three main conclusions are obtained through the sensitivity analysis: the multiscattering between vegetation and the background can be ignored when the leaf (soil) emissivity is no less than 0.94 (0.90), the second and higher order scattering within the vegetation can also be ignored when the leaf (soil) emissivity is no less than 0.94 (0.90), and the single-scattering effect within the canopy should be considered which can be calculated using three view factors.

58 GEOSCIENCES↗

Verification and Validation of High-Fidelity Multi-Physics Simulation Codes for Advanced Nuclear Reactors (Year 2)

The project objective is to verify and validate a suite of high-fidelity multi-physics simulation methods and codes developed during the previous I-NERI projects, against Monte Carlo solutions and experimental measurements for LWR and VHTR cores. Using benchmark problems developed during the previous year, ANL and KAERI continued to work on verifying the neutronics code DeCART and associated cross section libraries. Initial progress was also made on validating the code against experimental data. KAERI focused on verifying the DeCART code against numerical benchmark problems such as a PMR200 2-D pin cell/core and a HTTR 2-D block/core as well as improving DeCART capabilities such as the cross-section library group structure optimization, the fundamental and generalized adjoint equation solver, cylindrical boundary treatment, improved ray tracing, and implementing the direct resonance integral table method for resonance treatment. Verification test results for the updated capabilities showed substantial improvements in the estimation of eigenvalue and reaction rates.

Lee, C. H.↗

CTRANS: A Monte Carlo program for radiative transfer in plane parallel atmospheres with imbedded finite clouds: Development, testing and user's guide

The program called CTRANS is described which was designed to perform radiative transfer computations in an atmosphere with horizontal inhomogeneities (clouds). Since the atmosphere-ground system was to be richly detailed, the Monte Carlo method was employed. This means that results are obtained through direct modeling of the physical process of radiative transport. The effects of atmopheric or ground albedo pattern detail are essentially built up from their impact upon the transport of individual photons. The CTRANS program actually tracks the photons backwards through the atmosphere, initiating them at a receiver and following them backwards along their path to the Sun. The pattern of incident photons generated through backwards tracking automatically reflects the importance to the receiver of each region of the sky. Further, through backwards tracking, the impact of the finite field of view of the receiver and variations in its response over the field of view can be directly simulated.

Source record↗

Growth morphology with anisotropic surface kinetics

The morphological evolution of crystals growing from an incongruent vapor phase is studied using a Monte Carlo model, and the full range of growth morphologies is recovered. The diffusion in the bulk nutrient and the anisotropy in the interface kinetics are morphologically destabilizing and stabilizing, respectively. For a given set of simulation parameters and lattice symmetries there is a critical size, which scales linearly with the mean free path in the vapor, beyond which a crystal cannot retain its stable, macroscopically faceted growth shape. Surface diffusion stabilizes faceted growth on the shorter scale of the mean surface diffusion length. In simulations with a uniform drift superimposed on the random walk nutrient transport, crystal faces oriented toward the drift show enhanced morphological stability compared to the purely diffusive situation. Rotational drifts with periodic reversal of direction are morphologically stabilizing for all crystal facets.

Xiao, Rong-Fu↗

SU-G-JeP3-06: Lower KV Image Dose Are Expected From a Limited-Angle Intra-Fractional Verification (LIVE) System for SBRT Treatments

Purpose: In order to track the tumor movement for patient positioning verification during arc treatment delivery or in between 3D/IMRT beams for stereotactic body radiation therapy (SBRT), the limited-angle kV projections acquisition simultaneously during arc treatment delivery or in-between static treatment beams as the gantry moves to the next beam angle was proposed. The purpose of this study is to estimate additional imaging dose resulting from multiple tomosynthesis acquisitions in-between static treatment beams and to compare with that of a conventional kV-CBCT acquisition. Methods: kV imaging system integrated into Varian TrueBeam accelerators was modeled using EGSnrc Monte Carlo user code, BEAMnrc and DOSXYZnrc code was used in dose calculations. The simulated realistic kV beams from the Varian TrueBeam OBI 1.5 system were used to calculate dose to patient based on CT images. Organ doses were analyzed using DVHs. The imaging dose to patient resulting from realistic multiple tomosynthesis acquisitions with each 25–30 degree kV source rotation between 6 treatment beam gantry angles was studied. Results: For a typical lung SBRT treatment delivery much lower (20–50%) kV imaging doses from the sum of realistic six tomosynthesis acquisitions with each 25–30 degree x-ray source rotation between six treatment beam gantry angles were observed compared to that from a single CBCT image acquisition. Conclusion: This work indicates that the kV imaging in this proposed Limited-angle Intra-fractional Verification (LIVE) System for SBRT Treatments has a negligible imaging dose increase. It is worth to note that the MV imaging dose caused by MV projection acquisition in-between static beams in LIVE can be minimized by restricting the imaging to the target region and reducing the number of projections acquired. For arc treatments, MV imaging acquisition in LIVE does not add additional imaging dose as the MV images are acquired from treatment beams directly during the treatment.

60 APPLIED LIFE SCIENCES↗

Evaluated Iridium, Yttrium, and Thulium Cross Sections and Integral Validation Against Critical Assembly and Bethe Sphere Measurements

We describe new dosimetry (radiochemical) ENDF evaluations for yttrium, iridium, and thulium. These LANL2006 evaluations were based upon measured data and on nuclear model cross section calculations. In the case of iridium and yttrium, new measurements using the GEANIE gamma-ray detector at LANSCE were used to infer (n,xn) cross sections, the measurements being augmented by nuclear model calculations using the GNASH code. The thulium isotope evaluations were based on GNASH calculations and older measurements. The evaluated cross section data are tested through comparisons of simulations with measurements of reaction rates in critical assemblies and in Bethe sphere (sometimes called Wyman sphere) integral experiments. Two types of Bethe sphere experiments were studied - a LiD experiment that had a significant component of 14 MeV neutrons, and a LiD-U experiment that additionally had varying amounts of fission neutrons depending upon the location. These simulations were performed with the MCNP code using continuous energy Monte Carlo, and because the neutron fluences can be modeled fairly accurately by MCNP at different locations in these assemblies, the comparisons provide a valuable validation test of the accuracy of the evaluated cross sections and their energy dependencies. The MCNP integral reaction rate validation testing for the three detectors yttrium, iridium, and thulium, in the LANL2006 database is summarized as follows: (1) (n,2n)near 14 MeV: In 14 MeV-dominated locations (the LiD Bethe spheres and the outer regions of the LiD-U Bethe spheres), the (n,2n) products are modeled very well for all three detectors, suggesting that the evaluated {sup 89}Y(n,2n), {sup 191}Ir(n,2n), and {sup 169}Tm(n,2n) cross sections are accurate to better than about 5% near 14 MeV; (2) (n,2n)near threshold: In locations that have a significant number of fission spectrum neutrons or downscattered neutrons from 14 MeV inelastic scattering (the central regions of the LiD-U spheres and the fast critical assemblies), the (n,2n) products are overpredicted by 5-30 % for the three detectors, suggesting either the threshold region (n,2n) cross sections are too high, or that the MCNP-simulated neutron flux is too large for neutron energies above about 8 MeV; (3) Capture: The capture products for yttrium are modeled accurately for the LiD Bethe spheres, but are underpredicted by about 20% for the LiD-U Bethe spheres and the critical assemblies; for iridium-191 they are predicted accurately in the critical assemblies; and for thulium they are generally overpredicted by 10-30 %; (4) Inelastic scattering in iridium: The evaluated {sup 193}Ir(n,n{sup '}){sup 193m}Ir cross section performs well over a very wide range of neutron spectra (where the 193m/190 spectrum hardness index varies by over three orders of magnitude), the differences between simulation and experiment typically being better than 10-15%; (5) Iridium 193m/190 spectrum hardness index: Our simulations reproduce the measured 193m/190 data typically to better than 10-20% over three orders of magnitude in the 193m/190 ratio. The aforementioned indications from data testing involving assemblies containing actinides - that the (n,2n) products are overpredicted by 5-30% - could be used to motivate a decrease in the evaluated (n,2n) cross sections in the approximately 8-12 MeV range. However, at this stage we have not modified these cross sections since: (a) They are consistent with the cross section laboratory measurements; and (b) It is possible that the cross sections are correct and instead the simulated integral assembly neutron spectrum is too high for neutron energies above 8 MeV. The latter possibility is particularly intriguing given all three detector materials showed a bias in the same direction, and that the evaluated actinide prompt fission spectra and inelastic scattering data are probably uncertain to at least 20% above 8 MeV. We also discuss refinements needed in the transport methods to faithfully represent the evaluated data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-BRA-06: Dose Distributions for the CivaSheet Pd-103 Directional Brachytherapy Device

Purpose: A flexible polymer membrane (CivaSheet) has been developed by CivaTech Oncology, Inc. (Research Triangle Park, NC) for permanent brachytherapy. Distributed throughout the array are small plastic disks containing Pd-103 and gold foil shielding on one side to provide a directional dose distribution and facilitate imaging. This study evaluated dosimetry for the CivaSheet. Methods: Manufacturer-provided dimensional and compositional information for the device were compared to physical samples for validation of design information, then entered into the MCNP6 radiation transport code for dosimetry simulations. Three device sizes (6×6, 6×12, or 6×18 disk-arrays) were simulated as the membrane can be custom-sized preceding surgical placement. Dose to water was estimated with 0.01 cm resolution from the surface to 10 cm on both sides of the device. Because this is a novel device with calibration methods under development, results were normalized using DVHs to provide 90% prescription coverage to a plane positioned 0.5 cm from the front surfaces. This same normalization was used for creating isodose distributions. Results: Planar dose distributions of flat CivaSheets were relatively homogeneous with acceptable dose uniformity variations. Differences in the results between the differently sized CivaSheets were not significant. At 0.5 mm, 87% of the target volume was within the therapeutic dose range. Dose hotspots on the CivaSheet forward surfaces were directly above the disks. However, dose hotspots on the rear-facing surfaces were positioned between the disks. Doses in contact with the front surface were similar to those observed for currently available brachytherapy sources. Maximum doses that occurred on the rear surface were approximately 55 times lower than the dose on the front surface. Conclusion: Monte Carlo calculations validated the directional capabilities and advantageous dosimetry of the new Pd-103 brachytherapy device. It appears feasible to re-size the CivaSheet in the operating room with an acceptable variation in prescription dose. Research was supported by CivaTech Oncology, Inc.

60 APPLIED LIFE SCIENCES↗