Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Delivery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Transport spatial model for the definition of green routes for city logistics centers

This paper presents a transport spatial decision support model (TSDSM) for carrying out the optimization of green routes for city logistics centers. The TSDSM model is based on the integration of the multi-criteria method of Weighted Linear Combination (WLC) and the modified Dijkstra algorithm within a geographic information system (GIS). The GIS is used for processing spatial data. The proposed model makes it possible to plan routes for green vehicles and maximize the positive effects on the environment, which can be seen in the reduction of harmful gas emissions and an increase in the air quality in highly populated areas. The scheduling of delivery vehicles is given as a problem of optimization in terms of the parameters of: the environment, health, use of space and logistics operating costs. Each of these input parameters was thoroughly examined and broken down in the GIS into criteria which further describe them. The model presented here takes into account the fact that logistics operators have a limited number of environmentally friendly (green) vehicles available. The TSDSM was tested on a network of roads with 127 links for the delivery of goods from the city logistics center to the user. The model supports any number of available environmentally friendly or environmentally unfriendly vehicles consistent with the size of the network and the transportation requirements. - Highlights: • Model for routing light delivery vehicles in urban areas. • Optimization of green routes for city logistics centers. • The proposed model maximizes the positive effects on the environment. • The model was tested on a real network.

54 ENVIRONMENTAL SCIENCES↗

Innovative urban forestry governance in Melbourne?: Investigating “green placemaking” as a nature-based solution

Highlights: • Scholars have called for a re-assessment of urban environmental governance. • We examine the City of Melbourne's Urban Forest Strategy (UFS). • Co-governance arrangements in the UFS foster situated decision making pluralism. • Melbourne’s UFS links aims of biodiversity to those of socio-ecological resilience. A nature-based approach to climate resilience aims to challenge and re-frame conventional environmental management methods by refocusing solutions from technological strategies to socio-ecological principles such as human well-being and community-based governance models, thereby improving and legitimizing the delivery of ecosystem services (ES). There are, however, many challenges to applying a socio-ecological agenda to urban climate resilience and thereby re-framing ES delivery as community and people focused, a knowledge gap extensively outlined in the environmental governance literature. In this paper, we aim to contribute to this re-assesment of urban environmental governance by examining the City of Melbourne's approach to urban re-naturing governance from a place-based perspective. Here we focus on the city's internationally-acclaimed urban forest strategy (UFS), investigating how and to which extent the governance arrangements embedded within the UFS draw strength from diverse perspectives and allow for institutional arrangements that support “situated” reflexive decision making and co-creation. We find that Melbourne's UFS governance process fosters green placemaking by re-focusing climate adaptation solutions from technological strategies to situated socio-ecological principles such as human well-being and community-based decision making. In this sense, this case provides valuable insight for the broader UGI governance field regarding the opportunities and challenges associated with a socio-cultural approach to urban re-naturing and ES delivery.

54 ENVIRONMENTAL SCIENCES↗

Carbon dioxide pipeline network transportation cost model: evaluating economic and geographic factors for efficient carbon capture, storage, and utilization

This study presents a comprehensive pipeline network modeling framework to estimate the CO 2 delivery cost for CO 2 utilization and geologic CO 2 storage across the United States. We developed a Python-based CO 2 pipeline transportation cost model leveraging Argonne National Laboratory’s pipeline engineering expertise and detailed natural gas transmission pipeline cost data across U.S. regions. Using existing road corridors as practical routing guides, the model designs pipeline networks that aggregate CO 2 from one or multiple sources and deliver it to selected destinations. It then minimizes the total transportation cost by optimizing pipeline diameters and incorporating booster pumps. A key contribution is the incorporation of up-to-date, region-specific cost factors with itemized components for materials, labor, miscellaneous construction expenses, and right-of-way acquisition. Results emphasize that regional variation and economies of scale associated with CO 2 pipeline costs are significant and should be explicitly accounted for in screening and planning studies. By combining realistic routing constraints with regionalized cost inputs, the model provides transparent design methodology and location-specific insights into source–destination delivery costs, including the effects of routing complexity along existing road networks. We demonstrate the model with two illustrative case studies – one for CO 2 storage and one for CO 2 utilization – in which the model designs pipeline networks spanning hundreds of miles across the states, collecting CO 2 from multiple sources and delivering it to designated endpoints while minimizing levelized cost of delivery via diameter and compression optimization. The model offers a practical, scalable approach for alternative design option screening and early-stage CO 2 transportation planning.

CCS↗

First responder training: Supporting commercialization of hydrogen and fuel cell technologies

A properly trained first responder community is critical to the successful introduction of hydrogen fuel cell applications and their transformation in how we use energy. Providing resources with accurate information and current knowledge is essential to the delivery of effective hydrogen and fuel cell-related first responder training. Furthermore, the California Fuel Cell Partnership and the Pacific Northwest National Laboratory have over 15 years of experience in developing and delivering hydrogen safety-related first responder training materials and programs. A National Hydrogen and Fuel Cell Emergency Response Training Resource was recently released (http://h2tools.org/fr/nt/). This training resource serves the delivery of a variety of training regimens. Associated materials are adaptable for different training formats, ranging from high-level overview presentations to more comprehensive classroom training. Our paper presents what has been learned from the development and delivery of hydrogen safety-related first responder training programs (online, classroom, hands-on) by the respective organizations. We discussed the collaborative strategy being developed for enhancing training materials and methods for greater accessibility based on stakeholder input.

25 ENERGY STORAGE↗

The Dosimetric Effect of Intrafraction Prostate Motion on Step-and-Shoot Intensity-Modulated Radiation Therapy Plans: Magnitude, Correlation With Motion Parameters, and Comparison With Helical Tomotherapy Plans

Purpose: To determine the daily and cumulative dosimetric effects of intrafraction prostate motion on step-and-shoot (SNS) intensity-modulated radiation therapy (IMRT) plans, to evaluate the correlation of dosimetric effect with motion-based metrics, and to compare on a fraction-by-fraction basis the dosimetric effect induced in SNS and helical tomotherapy plans. Methods and Materials: Intrafraction prostate motion data from 486 fractions and 15 patients were available. A motion-encoded dose calculation technique was used to determine the variation of the clinical target volume (CTV) D{sub 95%} values with respect to the static plan for SNS plans. The motion data were analyzed separately, and the correlation coefficients between various motion-based metrics and the dosimetric effect were determined. The dosimetric impact was compared with that incurred during another IMRT technique to assess correlation across different delivery techniques. Results: The mean ({+-}1 standard deviation [SD]) change in D{sub 95%} in the CTV over all 486 fractions was 0.2 {+-} 0.5%. After the delivery of five and 12 fractions, the mean ({+-}1 SD) changes over the 15 patients in CTV D{sub 95%} were 0.0 {+-} 0.2% and 0.1 {+-} 0.2%, respectively. The correlation coefficients between the CTV D{sub 95%} changes and the evaluated motion metrics were, in general, poor and ranged from r = -0.2 to r = -0.39. Dosimetric effects introduced by identical motion in SNS and helical tomotherapy IMRT techniques were poorly correlated with a correlation coefficient of r = 0.32 for the CTV. Conclusions: The dosimetric impact of intrafraction prostate motion on the CTV is, in general, small. In only 4% of all fractions did the dosimetric consequence exceed 1% in the CTV. As expected, the cumulative effect was further reduced with fractionation. The poor correlations between the calculated motion parameters and the subsequent dosimetric effect implies that motion-based thresholds are of limited value in predicting the dosimetric impact of intrafraction motion. The dosimetric effects between the two evaluated delivery techniques were poorly correlated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Tumor Radiobiology of SRS and SBRT: Are More Than the 5 Rs Involved?

Stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT), also known as stereotactic ablative radiation therapy (SABR), are rapidly becoming accepted practice for the radiation therapy of certain tumors. Typically, SRS and SBRT involve the delivery of 1 or a few large-dose fractions of 8 to 30 Gy per fraction: a major paradigm shift from radiation therapy practice over the past 90 years, when, with relatively large amounts of normal tissues receiving high doses, the goal was to maximize tumor response for an acceptable level of normal tissue injury. The development of SRS and SBRT have come about because of technologic advances in image guidance and treatment delivery techniques that enable the delivery of large doses to tumors with reduced margins and high gradients outside the target, thereby minimizing doses to surrounding normal tissues. Because the results obtained with SRS and SBRT have been impressive, they have raised the question whether classic radiobiological modeling, and the linear-quadratic (LQ) model, are appropriate for large doses per fraction. In addition to objections to the LQ model, the possibility of additional biological effects resulting from endothelial cell damage, enhanced tumor immunity, or both have been raised to account for the success of SRS and SBRT. In this review, we conclude that the available preclinical and clinical data do not support a need to change the LQ model or to invoke phenomena over and above the classic 5 Rs of radiobiology and radiation therapy, with the likely exception that for some tumors high doses of irradiation may produce enhanced antitumor immunity. Thus, we suggest that for most tumors, the standard radiobiology concepts of the 5 Rs are sufficient to explain the clinical data, and the excellent results obtained from clinical studies are the result of the much larger biologically effective doses that are delivered with SRS and SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Continuous Monitoring and Intrafraction Target Position Correction During Treatment Improves Target Coverage for Patients Undergoing SBRT Prostate Therapy

Purpose: To compare the potential benefits of continuous monitoring of prostate position and intervention (CMI) using 2-mm displacement thresholds during stereotactic body radiation therapy (SBRT) treatment to those of a conventional image-guided procedure involving single localization prior to treatment. Methods and Materials: Eighty-nine patients accrued to a prostate SBRT dose escalation protocol were implanted with radiofrequency transponder beacons. The planning target volume (PTV) margin was 5 mm in all directions, except for 3 mm in the posterior direction. The prostate was kept within 2 mm of its planned position by the therapists halting dose delivery and, if necessary, correcting the couch position. We computed the number, type, and time required for interventions and where the prostate would have been during dose delivery had there been, instead, a single image-guided setup procedure prior to each treatment. Distributions of prostate displacements were computed as a function of time. Results: After the initial setup, 1.7 interventions per fraction were required, with a concomitant increase in time for dose delivery of approximately 65 seconds. Small systematic drifts in prostate position in the posterior and inferior directions were observed in the study patients. Without CMI, intrafractional motion would have resulted in approximately 10% of patients having a delivered dose that did not meet our clinical coverage requirement, that is, a PTV D95 of >90%. The posterior PTV margin required for 95% of the dose to be delivered with the target positioned within the PTV was computed as a function of time. The margin necessary was found to increase by 2 mm every 5 minutes, starting from the time of the imaging procedure. Conclusions: CMI using a tight 2-mm displacement threshold was not only feasible but was found to deliver superior PTV coverage compared with the conventional image-guided procedure in the SBRT setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic Collimator Angle Adjustments During Volumetric Modulated Arc Therapy to Account for Prostate Rotations

Purpose: Rotations of the prostate gland induce considerable geometric uncertainties in prostate cancer radiation therapy. Collimator and gantry angle adjustments can correct these rotations in intensity modulated radiation therapy. Modern volumetric modulated arc therapy (VMAT) treatments, however, include a wide range of beam orientations that differ in modulation, and corrections require dynamic collimator rotations. The aim of this study was to implement a rotation correction strategy for VMAT dose delivery and validate it for left-right prostate rotations. Methods and Materials: Clinical VMAT treatment plans of 5 prostate cancer patients were used. Simulated left-right prostate rotations between +15° and −15° were corrected by collimator rotations. We compared corrected and uncorrected plans by dose volume histograms, minimum dose (D{sub min}) to the prostate, bladder surface receiving ≥78 Gy (S78) and rectum equivalent uniform dose (EUD; n=0.13). Each corrected plan was delivered to a phantom, and its deliverability was evaluated by γ-evaluation between planned and delivered dose, which was reconstructed from portal images acquired during delivery. Results: On average, clinical target volume minimum dose (D{sub min}) decreased up to 10% without corrections. Negative left-right rotations were corrected almost perfectly, whereas D{sub min} remained within 4% for positive rotations. Bladder S78 and rectum EUD of the corrected plans matched those of the original plans. The average pass rate for the corrected plans delivered to the phantom was 98.9% at 3% per 3 mm gamma criteria. The measured dose in the planning target volume approximated the original dose, rotated around the simulated left-right angle, well. Conclusions: It is feasible to dynamically adjust the collimator angle during VMAT treatment delivery to correct for prostate rotations. This technique can safely correct for left-right prostate rotations up to 15°.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bioluminescence Tomography–Guided Radiation Therapy for Preclinical Research

Purpose: In preclinical radiation research, it is challenging to localize soft tissue targets based on cone beam computed tomography (CBCT) guidance. As a more effective method to localize soft tissue targets, we developed an online bioluminescence tomography (BLT) system for small-animal radiation research platform (SARRP). We demonstrated BLT-guided radiation therapy and validated targeting accuracy based on a newly developed reconstruction algorithm. Methods and Materials: The BLT system was designed to dock with the SARRP for image acquisition and to be detached before radiation delivery. A 3-mirror system was devised to reflect the bioluminescence emitted from the subject to a stationary charge-coupled device (CCD) camera. Multispectral BLT and the incomplete variables truncated conjugate gradient method with a permissible region shrinking strategy were used as the optimization scheme to reconstruct bioluminescent source distributions. To validate BLT targeting accuracy, a small cylindrical light source with high CBCT contrast was placed in a phantom and also in the abdomen of a mouse carcass. The center of mass (CoM) of the source was recovered from BLT and used to guide radiation delivery. The accuracy of the BLT-guided targeting was validated with films and compared with the CBCT-guided delivery. In vivo experiments were conducted to demonstrate BLT localization capability for various source geometries. Results: Online BLT was able to recover the CoM of the embedded light source with an average accuracy of 1 mm compared to that with CBCT localization. Differences between BLT- and CBCT-guided irradiation shown on the films were consistent with the source localization revealed in the BLT and CBCT images. In vivo results demonstrated that our BLT system could potentially be applied for multiple targets and tumors. Conclusions: The online BLT/CBCT/SARRP system provides an effective solution for soft tissue targeting, particularly for small, nonpalpable, or orthotopic tumor models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Results From the Imaging and Radiation Oncology Core Houston's Anthropomorphic Phantoms Used for Proton Therapy Clinical Trial Credentialing

Purpose: The purpose of this study was to summarize the findings of anthropomorphic proton phantom irradiations analyzed by the Imaging and Radiation Oncology Core Houston QA Center (IROC Houston). Methods and Materials: A total of 103 phantoms were irradiated by proton therapy centers participating in clinical trials. The anthropomorphic phantoms simulated heterogeneous anatomy of a head, liver, lung, prostate, and spine. Treatment plans included those for scattered, uniform scanning, and pencil beam scanning beam delivery modalities using 5 different treatment planning systems. For every phantom irradiation, point doses and planar doses were measured using thermoluminescent dosimeters (TLD) and film, respectively. Differences between measured and planned doses were studied as a function of phantom, beam delivery modality, motion, repeat attempt, treatment planning system, and date of irradiation. Results: The phantom pass rate (overall, 79%) was high for simple phantoms and lower for phantoms that introduced higher levels of difficulty, such as motion, multiple targets, or increased heterogeneity. All treatment planning systems overestimated dose to the target, compared to TLD measurements. Errors in range calculation resulted in several failed phantoms. There was no correlation between treatment planning system and pass rate. The pass rates for each individual phantom are not improving over time, but when individual institutions received feedback about failed phantom irradiations, pass rates did improve. Conclusions: The proton phantom pass rates are not as high as desired and emphasize potential deficiencies in proton therapy planning and/or delivery. There are many areas for improvement with the proton phantom irradiations, such as treatment planning system dose agreement, range calculations, accounting for motion, and irradiation of multiple targets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A planning study of simultaneous integrated boost with forward IMRT for multiple brain metastases

The objective of this study was to evaluate the dose conformity and feasibility of whole-brain radiotherapy with a simultaneous integrated boost by forward intensity-modulated radiation therapy in patients with 1 to 3 brain metastases. Forward intensity-modulated radiation therapy plans were generated for 10 patients with 1 to 3 brain metastases on Pinnacle 6.2 Treatment Planning System. The prescribed dose was 30 Gy to the whole brain (planning target volume [PTV]{sub wbrt}) and 40 Gy to individual brain metastases (PTV{sub boost}) simultaneously, and both doses were given in 10 fractions. The maximum diameters of individual brain metastases ranged from 1.6 to 6 cm, and the summated PTVs per patient ranged from 1.62 to 69.81 cm{sup 3}. Conformity and feasibility were evaluated regarding conformation number and treatment delivery time. One hundred percent volume of the PTV{sub boost} received at least 95% of the prescribed dose in all cases. The maximum doses were less than 110% of the prescribed dose to the PTV{sub boost}, and all of the hot spots were within the PTV{sub boost}. The volume of the PTV{sub wbrt} that received at least 95% of the prescribed dose ranged from 99.2% to 100%. The mean values of conformation number were 0.682. The mean treatment delivery time was 2.79 minutes. Ten beams were used on an average in these plans. Whole-brain radiotherapy with a simultaneous integrated boost by forward intensity-modulated radiation therapy in 1 to 3 brain metastases is feasible, and treatment delivery time is short.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric comparison of two arc-based stereotactic body radiotherapy techniques for early-stage lung cancer

To compare the dosimetric and delivery characteristics of two arc-based stereotactic body radiotherapy (SBRT) techniques for early-stage lung cancer treatment. SBRT treatment plans for lung tumors of different sizes and locations were designed using a single-isocenter multisegment dynamic conformal arc technique (SiMs-arc) and a volumetric modulated arc therapy technique (RapidArc) for 5 representative patients treated previously with lung SBRT. The SiMs-arc plans were generated with the isocenter located in the geometric center of patient's axial plane (which allows for collision-free gantry rotation around the patient) and 6 contiguous 60° arc segments spanning from 1° to 359°. 2 RapidArc plans, one using the same arc geometry as the SiMs-arc and the other using typical partial arcs (210°) with the isocenter inside planning target volume (PTV), were generated for each corresponding SiMs-arc plan. All plans were generated using the Varian Eclipse treatment planning system (V10.0) and were normalized with PTV V{sub 100} to 95%. PTV coverage, dose to organs at risk, and total monitor units (MUs) were then compared and analyzed. For PTV coverage, the RapidArc plans generally produced higher PTV D{sub 99} (by 1.0% to 3.3%) and higher minimum dose (by 2.7% to 12.7%), better PTV conformality index (by 1% to 8%), and less volume of 50% dose outside 2 cm from PTV (by 0 to 20.8 cm{sup 3}) than the corresponding SiMs-arc plans. For normal tissues, no significant dose differences were observed for the lungs, trachea, chest wall, and heart; RapidArc using partial arcs produced lowest maximum dose to spinal cord. For dose delivery, the RapidArc plans typically required 50% to 90% more MUs than SiMs-arc plans to deliver the same prescribed dose. The additional intensity modulation afforded by variable gantry speed and dose rate and by overlapping arcs enabled RapidArc plans to produce dosimetrically improved plans for lung SBRT, but required more MUs (by a factor > 1.5) to deliver. The dosimetric improvements, most notably in PTV minimum dose and in dose conformality for irregularly shaped PTVs, may outweigh the increased MUs in using RapidArc. For small and peripherally located tumors, SiMs-arc produces comparable dosimetric quality and could be more efficient in both treatment planning and dose delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Pancreatic cancer planning: Complex conformal vs modulated therapies

To compare the roles of intensity-modulated radiation therapy (IMRT) and volumetric- modulated arc therapy (VMAT) therapy as compared to simple and complex 3-dimensional chemoradiotherpy (3DCRT) planning for resectable and borderline resectable pancreatic cancer. In all, 12 patients who received postoperative radiotherapy (8) or neoadjuvant concurrent chemoradiotherapy (4) were evaluated retrospectively. Radiotherapy planning was performed for 4 treatment techniques: simple 4-field box, complex 5-field 3DCRT, 5 to 6-field IMRT, and single-arc VMAT. All volumes were approved by a single observer in accordance with Radiation Therapy Oncology Group (RTOG) Pancreas Contouring Atlas. Plans included tumor/tumor bed and regional lymph nodes to 45 Gy; with tumor/tumor bed boosted to 50.4 Gy, at least 95% of planning target volume (PTV) received the prescription dose. Dose-volume histograms (DVH) for multiple end points, treatment planning, and delivery time were assessed. Complex 3DCRT, IMRT, and VMAT plans significantly (p < 0.05) decreased mean kidney dose, mean liver dose, liver (V{sub 30}, V{sub 35}), stomach (D{sub 10}%), stomach (V{sub 45}), mean right kidney dose, and right kidney (V{sub 15}) as compared with the simple 4-field plans that are most commonly reported in the literature. IMRT plans resulted in decreased mean liver dose, liver (V{sub 35}), and left kidney (V{sub 15}, V{sub 18}, V{sub 20}). VMAT plans decreased small bowel (D{sub 10}%, D{sub 15}%), small bowel (V{sub 35}, V{sub 45}), stomach (D{sub 10}%, D{sub 15}%), stomach (V{sub 35}, V{sub 45}), mean liver dose, liver (V{sub 35}), left kidney (V{sub 15}, V{sub 18}, V{sub 20}), and right kidney (V{sub 18}, V{sub 20}). VMAT plans significantly decreased small bowel (D{sub 10}%, D{sub 15}%), left kidney (V{sub 20}), and stomach (V{sub 45}) as compared with IMRT plans. Treatment planning and delivery times were most efficient for simple 4-field box and VMAT. Excluding patient setup and imaging, average treatment delivery was within 10 minutes for simple and complex 3DCRT, IMRT, and VMAT treatments. This article shows significant improvements in 3D plan performance with complex planning over the more frequently compared 3- or 4-field simple 3D planning techniques. VMAT plans continue to demonstrate potential for the most organ sparing. However, further studies are required to identify if dosimetric benefits associated with inverse optimized planning can be translated into clinical benefits and if these treatment techniques are value-added therapies for this group of patients with cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric comparison of single-beam multi-arc and 2-beam multi-arc VMAT optimization in the Monaco treatment planning system

The purpose of this study was to evaluate the dosimetric and practical effects of the Monaco treatment planning system “max arcs-per-beam” optimization parameter in pelvic radiotherapy treatments. We selected for this study a total of 17 previously treated patients with a range of pelvic disease sites including prostate (9), bladder (1), uterus (3), rectum (3), and cervix (1). For each patient, 2 plans were generated, one using an arc-per-beam setting of “1” and another with an arc-per-beam setting of “2” using the volumes and constraints established from the initial clinical treatments. All constraints and dose coverage objects were kept the same between plans, and all plans were normalized to 99.7% to ensure 100% of the planning target volume (PTV) received 95% of the prescription dose. Plans were evaluated for PTV conformity, homogeneity, number of monitor units, number of control points, and overall plan acceptability. Treatment delivery time, patient-specific quality assurance procedures, and the impact on clinical workflow were also assessed. We found that for complex-shaped target volumes (small central volumes with extending arms to cover nodal regions), the use of 2 arc-per-beam (2APB) parameter setting achieved significantly lower average dose-volume histogram values for the rectum V{sub 20} (p = 0.0012) and bladder V{sub 30} (p = 0.0036) while meeting the high dose target constraints. For simple PTV shapes, we found reduced monitor units (13.47%, p = 0.0009) and control points (8.77%, p = 0.0004) using 2APB planning. In addition, we found a beam delivery time reduction of approximately 25%. In summary, the dosimetric benefit, although moderate, was improved over a 1APB setting for complex PTV, and equivalent in other cases. The overall reduced delivery time suggests that the use of mulitple arcs per beam could lead to reduced patient-on-table time, increased clinical throughput, and reduced medical physics quality assurance effort.

61 RADIATION PROTECTION AND DOSIMETRY↗

Structural and antibacterial properties of NSAID-loaded ultra-high molecular weight polyethylene

Peri-articular delivery of pain medication in joint arthroplasty has the potential to address post-operative pain and decrease the use of systemic opioids. Additionally, the sustained release from a delivery vehicle may be especially impactful in the initial post-operative period when pain is most severe. We recently described a novel approach for the sustained intra-articular delivery of an analgesic (bupivacaine) from an ultra-high molecular weight polyethylene (UHMWPE) bearing surface. A secondary but very significant effect of incorporating bupivacaine in UHMWPE was its antibacterial effect against Staphylococcal species, which are associated with the majority of periprosthetic joint infections. Here, we report on the structure, properties, elution characteristics and antibacterial properties of UHMWPE loaded with the non-steroidal anti-inflammatory drug (NSAID) — tolfenamic acid. We showed that 6 wt% drug loading was optimal for eluting clinically relevant intra-articular and systemic concentrations, for maintaining mechanical properties at a clinically relevant level, and for providing anti-colonization potential against low risk (planktonic) and high risk (biofilm forming) Staphylococcal species. We determined the osteoblast response to the tolfenamic acid-loaded UHMWPE to evaluate the cytotoxicity profile of this novel material. Tolfenamic acid-loaded UHMWPE has the potential to be used as a part of multimodal pain management therapy following arthroplasty and may provide prophylaxis for periprosthetic infection.

36 MATERIALS SCIENCE↗

Achieving superior carbon transfer efficiency and pH control using membrane carbonation with a wide range of CO 2 contents for the coccolithophore Emiliania huxleyi

The economic viability of microalgal-derived products relies on rapid CO 2 transfer in a cost-effective manner. Many industrial gas streams contain concentrated CO 2 that, if converted to useful products, would lower greenhouse gas emissions and valorize the wasted CO 2 . Membrane carbonation (MC) uses non-porous hollow-fiber gas-transfer membranes to deliver CO 2 without bubble formation, which makes it possible to achieve a high carbon-transfer efficiency (CTE). However, inert gasses in the industrial streams (e.g., N 2 , O 2 , and H 2 O) can significantly lower the CO 2 -delivery rate. The means to overcome the buildup of inert gases in the membrane lumen is to manage the distal end of the membranes to sweep out inert gases while not wasting significant CO 2 . A MC-venting strategy was evaluated for CO 2 inputs from 5% to 100%. Abiotic tests using a restricted exit flow could achieve >95% CTE abiotic for industrial CO 2 streams. When integrated with semi-continuous cultivation of a marine coccolithophore, Emiliania huxleyi , CO 2 delivery and venting were on-demand based on a pH set points and pH-actuated feed and venting valves. MC using the venting strategy achieved 100% CTE biotic when delivering 100% and 50% CO 2 , which was better than 50% CTE biotic obtained from pH-controlled sparging of 100% CO 2 -sparging. E. huxleyi consistently fixed ~80% of the delivered CO 2 into biomass, and the remaining ~20% to calcite coccoliths. Finally, the compact size of MC modules, stable pH control, and no shear forces from bubble agitation during the CO 2 delivery made MC an ideal match for cultivation of coccolithophores, which are sensitive to shear forces and pH fluctuations.

54 ENVIRONMENTAL SCIENCES↗

Reducing Radiation Damage in Soft Matter with Femtosecond-Timed Single-Electron Packets

In spite of the development of a myriad of mitigation methods, radiation damage continues to be a major limiting factor in transmission electron microscopy. Intriguing results have been reported using pulsed-laser driven and chopped electron beams for modulated dose delivery, but the underlying relationships and effects remain unclear. Indeed, delivering precisely timed single-electron packets to the specimen has yet to be systematically explored, and no direct comparisons to conventional methods within a common parameter space have been made. Here, using a model linear saturated hydrocarbon (n-hexatriacontane, C 36 H 74 ), we show that precisely timed delivery of each electron to the specimen, with a well-defined and uniform time between arrival, leads to a repeatable reduction in damage compared to conventional ultralow-dose methods for the same dose rate and the same accumulated dose. Using a femtosecond pulsed laser to confine the probability of electron emission to a 300 fs temporal window, we find damage to be sensitively dependent on the time between electron arrival (controlled with the laser repetition rate) and on the number of electrons per packet (controlled with the laser-pulse energy). Relative arrival times of 5, 20, and 100 μs were tested for electron packets comprised of, on average, 1, 5, and 20 electrons. In general, damage increased with decreasing time between electrons and, more substantially, with increasing electron number. Further, we find that improvements relative to conventional methods vanish once a threshold number of electrons per packet is reached. The results indicate that precise electron-by-electron dose delivery leads to a repeatable reduction in irreversible structural damage, and the systematic studies indicate this arises from control of the time between sequential electrons arriving within the same damage radius, all else being equal.

36 MATERIALS SCIENCE↗

Microfluidics Synthesis of Gene Silencing Cubosomes

The success of gene technologies hinges on our ability to engineer superior encapsulation and delivery vectors. Cubosomes are lipid-based nanoparticles where membranes, instead of enveloping into classic liposomes, intertwine into complex arrays of pores well-ordered in a cubic lattice. These complex nanoparticles encapsulate large contents of siRNA compared to a liposomal analogue. Importantly, the membranes that form cubosomes have intrinsic fusogenic properties that promote fast endosomal escape. Despite the great potential, traditional routes of forming cubosomes lead to particle sizes too large to fulfill the state-of-the art requirements of delivery vectors. To overcome this challenge, in this work we utilize a microfluidic nanomanufacturing device to synthesize cubosomes and siRNA-loaded cubosomes, termed cuboplexes. Utilizing cryogenic TEM and small angle X-ray scattering we elucidate the time-resolved mechanisms in which microfluidic devices allow the production of small cubosomes and cuboplexes (75 nm) that outperform commercially available delivery vectors, as well as liposome-based systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗