Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DETECTOR PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Mixing and CP violation in the B$0\atop{s}$ meson system at CDF; Mélange et violation de CP dans le système des mésons B$0\atop{s}$ à CDF

The two analyses presented in the thesis, the B$0\atop{s}$ mixing analysis and the B$0\atop{s}$ → J/ψφ angular analysis, share most of the technical implementations and features. Thus, my choice was to pursue in parallel the common aspects of the analyses, avoiding, whenever possible, repetitions. Each Chapter is split in two parts, the first one dedicated to the B$0\atop{s}$ mixing analysis and the second one describing the angular analysis on the B$0\atop{s}$ → J/ψφ decay mode. They are organized as follows. In Chapter 1 we present the theoretical framework of the B$0\atop{s}$ neutral mesons system. After a general introduction on the Standard Model, we focus on the quantities which are relevant to the Δms measurement and the CP violation phenomena, underlying the details concerning the study of pseudo-scalar to vector vector decays, P → VV, which allow to carry out an angular analysis. A discussion on the implication of the measurements performed in the search of physics beyond the Standard Model is presented. The accelerator facilities and the CDF-II detector are reported in Chapter 2. While describing the detector, more emphasis is given to the components fundamental to perform B physics analyses at CDF. The Chapter 3 is focused on the reconstruction and selection of the data samples. The Chapter starts with a description of the on-line trigger requirements, according to the B$0\atop{s}$ sample considered, followed by the offline selection criteria implemented to reconstruct B$0\atop{s}$ semileptonic and hadronic decays, fully and partially reconstructed, for the B$0\atop{s}$ mixing analysis, as well as the B$0\atop{s}$ → J/ψφ decay mode for the angular analysis. The subsequent Chapter 4 is dedicated to the revision of the technical ingredients needed in the final analyses. The B$0\atop{s}$ mixing elements are firstly described. The methodology historically used in the oscillation searches, the 'amplitude scan', is here introduced together with the calibration of the proper-decay-time resolution and the flavor tagging algorithms, in particular a closer examination of the same-side tagger performances is given. The B$0\atop{s}$ → J/ψφ angular analysis elements description then follows, focusing on the performances and the eventual differences with respect to the B$0\atop{s}$ oscillation search. The final results of the analyses are obtained with the use of an un-binned likelihood fitting framework: Chapter 5 presents the general principles behind this methodology and a description of both the maximum likelihood fitters employed. Chapter 6 contains the conclusive results on the B$0\atop{s}$ analyses. They are presented in an historical fashion: the measurement of the B$0\atop{s}$ oscillation frequency is followed by the first flavor tagged ΔΓs and βs measurements. The impact and the constraints on the parameters of the flavor model is part of the discussion in the Chapter. As cross-check of the B$0\atop{s}$ angular analysis, the B$0\atop{s}$ → J/ψK*0 decay mode has been additionally studied. Its angular analysis shows a competitive sensitivity with the B factories in measuring the parameters which define the decay. Not only this contributes to enforce the reliability of the entire framework, but it constitutes an excellent result by itself. Thus, we devote the entire Chapter 7 to the sole discussion of the angular analysis of the B$0\atop{s}$ → J/ψK*0 decay mode.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Synergy of Gamma-Ray Burst Detectors in the Glast Era

Simultaneous observations by the large number of gamma-ray burst detectors operating in the GLAST era will provide the spectra, lightcurves and locations necessary for studying burst physics and testing the putative relations between intrinsic burst properties. The detectors' energy bands and the accumulation timescale of their trigger system affect their sensitivity to hard vs. soft and long vs. short bursts. Coordination of the Swift and GLAST observing plans consistent with Swift's other science objectives could increase the detection rate of GLAST bursts with redshifts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Synergy of Gamma-Ray Burst Detectors In The Glast Era

Simultaneous observations by the large number of gamma-ray burst detectors operating in the GLAST era will provide the spectra, lightcurves and locations necessary for studying burst physics and testing the putative relations between intrinsic burst properties. The detectors' energy band and the accumulation timescale of their trigger system affect their sensitivity to hard vs. soft and long vs. short bursts. Coordination of the Swift and GLAST observing plans consistent with Swift's other science objectives could increase the rate of GLAST bursts with redshifts.

Band, David L.↗

A Comparison Framework for Reactor Anti-Neutrino Detectors in Near-Field Nuclear Safeguards Applications

Electron anti-neutrino ( e) detectors can support nuclear safeguards, from reactor monitoring to spent fuel characterization. In recent years, the scientific community has developed multiple detector concepts, many of which have been prototyped or deployed for specific measurements by their respective collaborations. However, the diversity of technical approaches, deployment conditions, and analysis techniques complicates direct performance comparison between designs. We have begun development of a simulation framework to compare and evaluate existing and proposed detector designs for nonproliferation applications in a uniform manner. This report demonstrates the intent and capabilities of the framework by evaluating four detector design concepts, calculating generic reactor antineutrino counting sensitivity, and capabilities in a plutonium disposition application example.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Distribution of Te inclusions in a CdZnTe wafer and their effects on the electrical properties of fabricated devices

We quantified the size and concentration of Te-inclusions along the lateral- and the growth-directions of a {approx}6 mm thick wafer cut axially along the center of a CdZnTe ingot. We fabricated devices, selecting samples from the center slice outward in both directions, and then tested their response to incident x-rays. We employed, in concert, an automated IR transmission microscopic system and a highly collimated synchrotron X-ray source that allowed us to acquire and correlate comprehensive information on Te inclusions and other defects to assess the material factors limiting the performance of CdZnTe detectors.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

FY07 LDRD Final Report Neutron Capture Cross-Section Measurements at DANCE

We have measured neutron capture cross sections intended to address defense science problems including mix and the Quantification of Margins and Uncertainties (QMU), and provide details about statistical decay of excited nuclei. A major part of this project included developing the ability to produce radioactive targets. The cross-section measurements were made using the white neutron source at the Los Alamos Neutron Science Center, the detector array called DANCE (The Detector for Advanced Neutron Capture Experiments) and targets important for astrophysics and stockpile stewardship. DANCE is at the leading edge of neutron capture physics and represents a major leap forward in capability. The detector array was recently built with LDRD money. Our measurements are a significant part of the early results from the new experimental DANCE facility. Neutron capture reactions are important for basic nuclear science, including astrophysics and the statistics of the {gamma}-ray cascades, and for applied science, including stockpile science and technology. We were most interested in neutron capture with neutron energies in the range between 1 eV and a few hundred keV, with targets important to basic science, and the s-process in particular. Of particular interest were neutron capture cross-section measurements of rare isotopes, especially radioactive isotopes. A strong collaboration between universities and Los Alamos due to the Academic Alliance was in place at the start of our project. Our project gave Livermore leverage in focusing on Livermore interests. The Lawrence Livermore Laboratory did not have a resident expert in cross-section measurements; this project allowed us to develop this expertise. For many radionuclides, the cross sections for destruction, especially (n,{gamma}), are not well known, and there is no adequate model that describes neutron capture. The modeling problem is significant because, at low energies where capture reactions are important, the neutron reaction cross sections show resonance behavior or follow 1/v of the incident neutrons. In the case of odd-odd nuclei, the modeling problem is particularly difficult because degenerate states (rotational bands) present in even-even nuclei have separated in energy. Our work included interpretation of the {gamma}-ray spectra to compare with the Statistical Model and provides information on level density and statistical decay. Neutron capture cross sections are of programmatic interest to defense sciences because many elements were added to nuclear devices in order to determine various details of the nuclear detonation, including fission yields, fusion yields, and mix. Both product nuclei created by (n,2n) reactions and reactant nuclei are transmuted by neutron capture during the explosion. Very few of the (n,{gamma}) cross sections for reactions that create products measured by radiochemists have ever been experimentally determined; most are calculated by radiochemical equivalences. Our new experimentally measured capture cross sections directly impact our knowledge about the uncertainties in device performances, which enhances our capability of carrying out our stockpile stewardship program. Europium and gadolinium cross sections are important for both astrophysics and defense programs. Measurements made prior to this project on stable europium targets differ by 30-40%, which was considered to be significantly disparate. Of the gadolinium isotopes, {sup 151}Gd is important for stockpile stewardship, and {sup 153}Gd is of high interest to astrophysics, and nether of these (radioactive) gadolinium (n,{gamma}) cross sections have been measured. Additional stable gadolinium isotopes, including {sup 157,160}Gd are of interest to astrophysics. Historical measurements of gadolinium isotopes, including {sup 152,154}Gd, had disagreements similar to the 30-40% disagreements found in the historical europium data. Actinide capture cross section measurements are important for both Stockpile Stewardship and for nuclear forensics. We focused on the {sup 242m}Am(n,{gamma}) measurement, as there was no existing capture measurement for this isotope. The cross-section measurements (cross section vs. E{sub n}) were made at the Detector for Advanced Neutron Capture Experiments. DANCE is comprised of a highly segmented array of barium fluoride (BaF{sub 2}) crystals specifically designed for neutron capture-gamma measurements, using small radioactive targets (less than one milligram). A picture of half the array, along with a photo of one crystal, is shown in Fig. 1. DANCE provides the world's leading capability for measurements of neutron capture cross sections with radioactive targets. The DANCE is a 4{pi} calorimeter and uses the intense spallation neutron source the Lujan Center at the Los Alamos National Laboratory. The detector array consists of 159 barium fluoride crystals arranged in a sphere around the target.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast Simulation of Electromagnetic Showers in the ATLAS Calorimeter: Frozen Showers

One of the most time consuming process simulating pp interactions in the ATLAS detector at LHC is the simulation of electromagnetic showers in the calorimeter. In order to speed up the event simulation several parametrisation methods are available in ATLAS. In this paper we present a short description of a frozen shower technique, together with some recent benchmarks and comparison with full simulation. An expected high rate of proton-proton collisions in ATLAS detector at LHC requires large samples of simulated events (Monte Carlo) to study various physics processes. A detailed simulation of particle reactions ('full simulation') in the ATLAS detector is based on GEANT4 and is very accurate. However, due to complexity of the detector, high particle multiplicity and GEANT4 itself, the average CPU time spend to simulate typical QCD event in pp collision is 20 or more minutes for modern computers. During detector simulation the largest time is spend in the calorimeters (up to 70%) most of which is required for electromagnetic particles in the electromagnetic (EM) part of the calorimeters. This is the motivation for fast simulation approaches which reduce the simulation time without affecting the accuracy. Several of fast simulation methods available within the ATLAS simulation framework (standard Athena based simulation program) are discussed here with the focus on the novel frozen shower library (FS) technique. The results obtained with FS are presented here as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a high resolution liquid xenon imaging chamber for gamma-ray astronomy

The objective was to develop the technology of liquid xenon (LXe) detectors for spectroscopy and imaging of gamma rays from astrophysical sources emitting in the low to medium energy regime. In particular, the technical challenges and the physical processes relevant to the realization of the LXe detector operated as a Time Projection Chamber (TPC) were addressed and studied. Experimental results were obtained on the following topics: (1) long distance drift of free electrons in LXe (purity); (2) scintillation light yield for electrons and alphas in LXe (triggering); and (3) ionization yield for electrons and gamma rays in LXe (energy resolution). The major results from the investigations are summarized.

Aprile, Elena↗

Measurement of the Inclusive $Z \to ee$ Production Cross Section in Proton-Proton Collisions at $\sqrt{s}$ = 7TeV and $Z \to ee$ Decays as Standard Candles for Luminosity at the Large Hadron Collider

This thesis comprises a precision measurement of the inclusive \Zee production cross section in proton-proton collisions provided by the Large Hadron Collider (LHC) at a center-of-mass energy of $\sqrt{s}=7$~TeV and the absolute luminosity based on \Zee decays. The data was collected by the Compact Muon Solenoid (CMS) detector near Geneva, Switzerland during the year of 2010 and corresponds to an integrated luminosity of $\int\mathcal{L}dt = 35.9\pm 1.4$~pb$^{-1}$. Electronic decays of $Z$ bosons allow one of the first electroweak measurements at the LHC, making the cross section measurement a benchmark of physics performance after the first year of CMS detector and LHC machine operations. It is the first systematic uncertainty limited \Zee cross section measurement performed at $\sqrt{s}=7$~TeV. The measured cross section pertaining to the invariant mass window $M_{ee}\in (60,120)$~GeV is reported as: $\sigma(pp\to Z+X) \times \mathcal{B}( Z\to ee ) = 997 \pm 11 \mathrm{(sta t)} \pm 19 \mathrm{(syst)} \pm 40 \mathrm{(lumi)} \textrm{ pb}$, which agrees with the theoretical prediction calculated to NNLO in QCD. Leveraging \Zee decays as ``standard candles'' for measuring the absolute luminosity at the LHC is examined; they are produced copiously, are well understood, and have clean detector signatures. Thus the consistency of the inclusive \Zee production cross section measurement with the theoretical prediction motivates inverting the measurement to instead use the \Zee signal yield to measure the luminosity. The result, which agrees with the primary relative CMS luminosity measurement calibrated using Van der Meer separation scans, is not only the most precise absolute luminosity measurement performed to date at a hadron collider, but also the first one based on a physics signal at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PhytoPET, PhytoBeta and PhytoSPECT: Radioisotope Imaging Systems Being Developed for Plant Biology Research

The Radiation Detector and Imaging Group at Thomas Jefferson National Accelerator Facility (Jefferson Lab) is developing radioisotope imaging systems designed and constructed to facilitate plant biology studies at the Duke University Phytotron. The imaging systems utilize nuclear medicine imaging methodologies used in positron emission tomography (PET) and single photon emission computed tomography (SPECT) but designed specifically for plant biology. The range of plant shapes and the environmental conditions in plant growth chambers pose a technological challenge. Description: Jefferson Lab is collaborating with the Duke University Phytotron and the Triangle Universities Nuclear Laboratory (TUNL) in the construction and operation of PhytoPET and PhytoBeta (for direct beta particle detection) for plant and/or microbe imaging. The TUNL tandem Van de Graaff accelerator (maximum terminal voltage of 10 MV) has been used to generate 11C and 13N for plant biology research. The PhytoPET and PhytoBeta have been used with 11C as a 11CO2 tracer for plant ecophysiology imaging with corn, poplar, oak and barley utilizing technologies developed for nuclear physics research and nuclear medicine. The imaging detectors are based on position sensitive photomultiplier tubes coupled to scintillators. Additionally, the collaboration is investigating a methodology using single photon emitting radioisotope tracers for imaging the distribution of molecular compounds of interest in the rhizosphere, the interface between root and soil, without disturbing the root or soil habitat. Plans are underway to develop a single photon emission computed tomography (SPECT) system (PhytoSPECT) to image the bio-distribution of fungi in association with a host plant's roots. In addition to a description of the technology an overview will be given of the application of PhytoPET, PhytBeta and PhytoSPECT to plant biology research at Duke University. Conclusions: We have developed and used radioisotope imaging technologies based on PET and SPECT to visualize plant function in changing environments. There are many opportunities to provide radioisotope based imaging tools for plant ecophysiology imaging. Keywords: radioisotope detection, plant biology, carbon-11, accelerator produced isotopes

Weisenberger, Andrew↗

TREK: A Search for Time Reversal Symmetry Violation in Charged Kaon Decays

The Time Reversal Experiment with Kaons (TREK) at J-PARC aims to find New Physics beyond the Standard Model by measuring the T-violating transverse polarization P{sub T} of muons in the K{sub {mu}3}{sup +} decay of stopped kaons. TREK will use a high-intensity kaon beam and the upgraded apparatus of the E-246 experiment from KEK-PS. The sensitivity for P{sub T} of 10{sup -4} at J-PARC is improved by a factor of 20 compared to the current E-246 limit, well in the allowed range of various models involving New Physics from exotic scalar interactions. An overview of the planned experiment and the status of the detector upgrade will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ILC Reference Design Report Volume 4 - Detectors

This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A simultaneous measurement of the $b$-tagging efficiency scale factor and the $t\bar{t}$ Production Cross Section at the Collider Detector at Fermilab

The ability to compare results between Monte Carlo and data is imperative in modern experimental high-energy physics analyses. The b-tagging efficiency Scale Factor (SF) allows for an accurate comparison of b quark identification in data samples and Monte Carlo. This thesis presents a simultaneous measurement of the SF for the SecVtx algorithm and the t{bar t} production cross section using 5.6 fb{sup -1} of p{bar p} collision data at {radical}s = 1.96 TeV collected by the Collider Detector at Fermilab (CDF) experiment. The t{bar t} cross section was measured to be 7.26 {+-} 0.47 pb, consistent with prior CDF analyses. The tight SF value was measured to be 0.925 {+-} 0.032 and the loose SF value was measured at 0.967 {+-} 0.033. These are the most precise SF SecVtx measurements to be performed at CDF to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CompF2: Theoretical Calculations and Simulation Topical Group Report

This report summarizes the work of the Computational Frontier topical group on theoretical calculations and simulation for Snowmass 2021. We discuss the challenges, potential solutions, and needs facing six diverse but related topical areas that span the subject of theoretical calculations and simulation in high energy physics (HEP): cosmic calculations, particle accelerator modeling, detector simulation, event generators, perturbative calculations, and lattice QCD (quantum chromodynamics). The challenges arise from the next generations of HEP experiments, which will include more complex instruments, provide larger data volumes, and perform more precise measurements. Calculations and simulations will need to keep up with these increased requirements. The other aspect of the challenge is the evolution of computing landscape away from general-purpose computing on CPUs and toward special-purpose accelerators and coprocessors such as GPUs and FPGAs. These newer devices can provide substantial improvements for certain categories of algorithms, at the expense of more specialized programming and memory and data access patterns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Material separation in x-ray CT with energy resolved photon-counting detectors

Purpose: The objective of the study was to demonstrate that, in x-ray computed tomography (CT), more than two types of materials can be effectively separated with the use of an energy resolved photon-counting detector and classification methodology. Specifically, this applies to the case when contrast agents that contain K-absorption edges in the energy range of interest are present in the object. This separation is enabled via the use of recently developed energy resolved photon-counting detectors with multiple thresholds, which allow simultaneous measurements of the x-ray attenuation at multiple energies. Methods: To demonstrate this capability, we performed simulations and physical experiments using a six-threshold energy resolved photon-counting detector. We imaged mouse-sized cylindrical phantoms filled with several soft-tissue-like and bone-like materials and with iodine-based and gadolinium-based contrast agents. The linear attenuation coefficients were reconstructed for each material in each energy window and were visualized as scatter plots between pairs of energy windows. For comparison, a dual-kVp CT was also simulated using the same phantom materials. In this case, the linear attenuation coefficients at the lower kVp were plotted against those at the higher kVp. Results: In both the simulations and the physical experiments, the contrast agents were easily separable from other soft-tissue-like and bone-like materials, thanks to the availability of the attenuation coefficient measurements at more than two energies provided by the energy resolved photon-counting detector. In the simulations, the amount of separation was observed to be proportional to the concentration of the contrast agents; however, this was not observed in the physical experiments due to limitations of the real detector system. We used the angle between pairs of attenuation coefficient vectors in either the 5-D space (for non-contrast-agent materials using energy resolved photon-counting acquisition) or a 2-D space (for contrast agents using energy resolved photon-counting acquisition and all materials using dual-kVp acquisition) as a measure of the degree of separation. Compared to dual-kVp techniques, an energy resolved detector provided a larger separation and the ability to separate different target materials using measurements acquired in different energy window pairs with a single x-ray exposure. Conclusions: We concluded that x-ray CT with an energy resolved photon-counting detector with more than two energy windows allows the separation of more than two types of materials, e.g., soft-tissue-like, bone-like, and one or more materials with K-edges in the energy range of interest. Separating material types using energy resolved photon-counting detectors has a number of advantages over dual-kVp CT in terms of the degree of separation and the number of materials that can be separated simultaneously.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interplay of energy dependent astrophysical neutrino flavor ratios and new physics effects

We discuss the importance of flavor ratio measurements in neutrino telescopes, such as by measuring the ratio between muon tracks to cascades, for the purpose of extracting new physics signals encountered by astrophysical neutrinos during propagation from the source to the detector. The detected flavor ratios not only carry the energy information of specific new physics scenarios which alter the transition probabilities in distinctive ways, but also the energy dependent flavor composition at the source. In the present work, we discuss the interplay of these two energy dependent effects and identify which new physics scenarios can be distinguished from the detected flavor ratios as a function of astrophysical parameters. We use a recently developed self-consistent neutrino production model as our toy model to generate energy dependent source flavor ratios and discuss (invisible) neutrino decay and quantum decoherence as specific new physics examples. Furthermore, we identify potentially interesting classes of sources on the Hillas plot for the purpose of new physics searches. We find that sources with substantial magnetic fields 10{sup 3} Gauss∼<B∼<10{sup 6} Gauss, such as Active Galactic Nuclei (AGN) cores, white dwarfs, or maybe gamma-ray bursts, have, in principle, the best discrimination power for the considered new physics scenarios, whereas AGN jets, which typically perform as pion beam sources, can only discriminate few sub cases in the new physics effects. The optimal parameter region somewhat depends on the class of new physics effect considered.

79 ASTRONOMY AND ASTROPHYSICS↗

Studying Neutrino Oscillations and Searches for BSM Physics with Atmospheric Neutrinos in DUNE

The 40kt DUNE Far Detector, located at the Sanford Underground Research Facility, will of- fer unique capabilities to study atmospheric neutrinos. Due to the detector’s excellent energy resolutions, angular resolutions, and particle ID capabilities, atmospheric neutrino analyses in DUNE can provide valuable information about 3-flavor oscillations, despite the relatively modest statistics. These data provide a complementary analysis approach to beam neutrinos, and can help in resolving ambiguities in beam-only analyses. In this paper we show the prospects on the determination of the mass hierarchy, octant of θ 23 , and measurement of δ CP using atmospheric neutrinos in DUNE. Atmospheric neutrinos can also lead to a variety of beyond the standard model scenarios for neutrino transitions, propagation, and interactions. Examples that have been previously studied include CPT violation, Lorentz invariance violation, non-standard interactions, mass varying neutrinos and sterile neutrinos.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗