Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contacts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Influence of Compaction During Reaction Heat Treatment on the Interstrand Contact Resistances of Nb 3 Sn Rutherford Cables for Accelerator Magnets

The high field superconducting magnets required for ongoing and planned upgrades to the Large Hadron Collider (LHC) will be wound with Nb 3 Sn Rutherford cables for which reason studies of Nb 3 Sn strand, cable, and magnet properties will continue to be needed. Of particular importance is field quality. Here, the amplitudes of multipoles in the bore fields of dipole and quadrupole magnets, induced by ramp-rate-dependent coupling currents, are under the control of the interstrand contact resistances-crossing strand, R c , adjacent strand, R a , or a combination of them, R eff . Although two decades ago it was agreed that for the LHC R c should be in the range 10-30 μΩ, more recent measurements of LHC quadrupoles have revealed R c values ranging from 95 to 230 μΩ. This paper discusses ways in which these values can be achieved. In a heavily compacted cable R eff can be tuned to some predictable value by varying the width of an included stainless steel (effectively “insulating”) core. But cables are no longer heavily compacted with the result that the crossing strands of the impregnated cable are separated by a thick epoxy layer that behaves like an insulating core. If a stainless steel core is actually present, Reff must be independent of core width. Since there is no guarantee that a fixed predetermined amount of interlayer separation could be reproduced from winding to winding it would be advisable to include a full width core.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Clean Cities Program Contacts (Fact Sheet)

This fact sheet contains contact information for program staff and coalition coordinators for the U.S. Department of Energy's Clean Cities program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clean Cities Program Contacts [Fact Sheet]

This fact sheet contains contact information for program staff and coalition coordinators for the U.S. Department of Energy's Clean Cities program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clean Cities Program Contacts (Fact Sheet)

This fact sheet contains contact information for program staff and coalition coordinators for the U.S. Department of Energy's Clean Cities program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Process Knowledge Summary Report for Advanced Test Reactor Complex Contact-Handled Transuranic Waste Drum TRA010029

This Process Knowledge Summary Report summarizes information collected to satisfy the transportation and waste acceptance requirements for the transfer of one drum containing contact-handled transuranic (TRU) actinide standards generated by the Idaho National Laboratory at the Advanced Test Reactor (ATR) Complex to the Advanced Mixed Waste Treatment Project (AMWTP) for storage and subsequent shipment to the Waste Isolation Pilot Plant for final disposal. The drum (i.e., Integrated Waste Tracking System Bar Code Number TRA010029) is currently stored at the Materials and Fuels Complex. The information collected includes documentation that addresses the requirements for AMWTP and applicable sections of their Resource Conservation and Recovery Act permits for receipt and disposal of this TRU waste generated from ATR. This Process Knowledge Summary Report includes information regarding, but not limited to, the generation process, the physical form, radiological characteristics, and chemical contaminants of the TRU waste, prohibited items, and packaging configuration. This report, along with the referenced supporting documents, will create a defensible and auditable record for this TRU waste originating from ATR.

99 GENERAL AND MISCELLANEOUS↗

Clean Cities Program Contacts [Fact Sheet]

Contact information for the U.S. Department of Energy's Clean Cities program staff and for the coordinators of the nearly 100 local Clean Cities coalitions across the country.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Causal Analysis of the Inadvertent Contact with an Uncontrolled Electrical Hazardous Energy Source (120 Volts AC)

On September 25, 2013, a Health Physics Technician (HPT) was performing preparations to support a pneumatic transfer from the HFEF Decon Cell to the Room 130 Glovebox in HFEF, per HFEF OI 3165 section 3.5, Field Preparations. This activity involves an HPT setting up and climbing a portable ladder to remove the 14-C meter probe from above ball valve HBV-7. The HPT source checks the meter and probe and then replaces the probe above HBV-7, which is located above Hood ID# 130 HP. At approximately 13:20, while reaching past the HBV-7 valve position indicator switches in an attempt to place the 14-C meter probe in the desired location, the HPT’s left forearm came in contact with one of the three sets of exposed terminals on the valve position indication switches for HBV 7. This resulted in the HPT receiving an electrical shock from a 120 Volt AC source. Upon moving the arm, following the electrical shock, the HPT noticed two exposed electrical connections on a switch. The HPT then notified the HFEF HPT Supervisor, who in turn notified the MFC Radiological Controls Manager and HFEF Operations Manager of the situation. Work was stopped in the area and the hazard was roped off and posted to prevent access to the hazard. The HPT was escorted by the HPT Supervisor to the MFC Dispensary and then preceded to CFA medical for further evaluation. The individual was evaluated and released without any medical restrictions. Causal Factor (Root Cause) A3B3C01/A5B2C08: - Knowledge based error/Attention was given to wrong issues - Written Communication content LTA, Incomplete/situation not covered The Causal Factor (root cause) was attention being given to the wrong issues during the creation, reviews, verifications, and actual performance of HFEF OI-3165, which covers the need to perform the weekly source check and ensure placement of the probe prior to performing a “rabbit” transfer. This resulted in the hazard not being identified and mitigated in the procedure. Work activities with in HFEF-OI-3165 placed the HPT in proximity of an unmitigated hazard directly resulting in this event. Contributing Factor A3B3C04/A4B5C04: - Knowledge Based Error, LTA Review Based on Assumption That Process Will Not Change - Change Management LTA, Risks/consequences associated with change not adequately reviewed/assessed Prior to the pneumatic system being out of service, the probe and meter were not being source checked together. The source check issue was identified and addressed during the period of time when the system was out of service. The corrective actions for this issue resulted in the requirement that a meter and probe be source checked together as it is intended to be used. This changed the activity and required an HPT to weekly, when in use, remove and install the probe from above HBV-7 to meet the requirement of LRD 15001 Part 5 Article 551.5. Risks and consequences associated with this change were not adequately reviewed or assessed. Failure to identify the hazard associated with this change directly contributed to this event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterization of Contact Degradation in Crystalline Silicon Photovoltaic Modules (Final Technical Report)

In this project, the aim was to develop highly-automated metrology methods that can provide more insights into degradation and failure, while still relying on the types of measurements the PV industry and RD communities are comfortable with (e.g., I – V and EL). In particular, our focus was to develop techniques to better understand contact and interconnect degradation in crystalline silicon (c-Si) PV modules and apply those techniques to conventional and emerging c-Si cell architectures and cell interconnection technologies.

14 SOLAR ENERGY↗

Revealing the Nano-Scale Structure and Properties of Pinholes in SiOx Layers for POLO Contacts

In this contribution, we report on the charge collection characteristics of silicon photovoltaic devices with passivated contacts based on the c-Si/SiOx /poly-Si structure. Using electron-beam induced current (EBIC) imaging in plan-view and cross-section orientations, we find that charge collection in a device with a 1.5-nm-thick SiOx layer is fairly uniform in the p-n junction region and does not appear to be influenced by pyramidal surface texture. In contrast, a device with a 2.2-nm-thick oxide layer shows significant spatial variation in the charge-collection signal. The locations where we observe preferential collection of excess carriers is very sensitive to the processing conditions used to grow and breakup the SiOx passivation layer. In some cases the apexes of the pyramids exhibit reduced EBIC signal as the valleys between adjacent pyramids show the strongest collection. Other conditions yield enhanced charge collection at well defined spots on pyramid faces with no observable collection in the valleys.

EBIC↗