Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPARATIVE TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Impact of PACS-EMR Integration on Radiologist Usage of the EMR

The purpose of this study was to objectively quantify the impact of implementing picture archiving and communication system-electronic medical record (PACS-EMR) integration on the time required to access data in the EMR and the frequency with which data are accessed by radiologists. Time to access a clinic note in the EMR was measured before and after integration with a stopwatch and compared by t test. An IRB-approved, HIPAA-compliant retrospective review of EMR access data from security audit logs was conducted for a 14-month period spanning the integration. Correlation of these data with report signatures identified the studies in which the radiologist accessed the EMR to obtain additional clinical data. Proportions of studies with EMR access were plotted and compared before and after integration using a chi-square test. Time to access the EMR decreased from 52 to 6 s (p < 0.001). Proportion of studies with EMR access increased from 36.7% (10,175/27,773) to 44.9% (10,843/24,153) after integration (p < 0.001). Integrating PACS and the EMR substantially decreases the time to access the EMR and is associated with a significant increase in the proportion of studies for which radiologists obtain additional clinical data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Test versus analysis: A discussion of methods

Some techniques for comparing structural vibration data determined from test and analysis are discussed. Orthogonality is a general category of one group, correlation is a second, synthesis is a third and matrix improvement is a fourth. Advantages and short-comings of the methods are explored with suggestions as to how they can complement one another. The purpose for comparing vibration data from test and analysis for a given structure is to find out whether each is representing the dynamic properties of the structure in the same way. Specifically, whether: mode shapes are alike; the frequencies of the modes are alike; modes appear in the same frequency sequence; and if they are not alike, how to judge which to believe.

Butler, T. G.↗

Detection and quantification of γ-H2AX using a dissociation enhanced lanthanide fluorescence immunoassay

Phosphorylation of the histone protein H2AX to form γ-H2AX foci directly represents DNA double-strand break formation. Traditional γ-H2AX detection involves counting individual foci within individual nuclei. The novelty of this work is the application of a time-resolved fluorescence assay using dissociation-enhanced lanthanide fluorescence immunoassay for quantitative measurements of γ-H2AX. For comparison, standard fluorescence detection was employed and analyzed either by bulk fluorescent measurements or by direct foci counting using BioTek Spot Count algorithm and Gen 5 software. Etoposide induced DNA damage in A549 carcinoma cells was compared across all test platforms. Time resolved fluorescence detection of europium as a chelated complex enabled quantitative measurement of γ-H2AX foci with nanomolar resolution. Comparative bulk fluorescent signals achieved only micromolar sensitivity. Lanthanide based immunodetection of γ-H2AX offers superior detection and a user-friendly workflow. These approaches have the potential to improve screening of compounds that either enhance DNA damage or protect against its deleterious effects.

59 BASIC BIOLOGICAL SCIENCES↗

Sensitivity Effects of Hollow Glass Micro-Balloon Doping on RDX-Based Explosives

Sensitivity to initiation is an important characteristic of high explosives. Many chemical and physical properties are fine-tuned to deliver an energetic material that behaves according to the user’s specifications exactly. In some cases, it is advantageous to study the effects that non energetic additives have on the performance of an explosive material. Following on the promising results obtained in other experiments, a study is conducted on the effects of hollow glass micro-balloons (bubbles, spheres), or HGMB, on a material’s sensitivity. Threshold test data is compared between several formulations of explosives. The control formulation is an RDX-based explosive with a non-energetic binder, and the test formulations are identical in composition, but with the addition of HGMB, up to 6% by volume. Safety testing of the new HGMB-doped explosive formulations is conducted to ensure they can be produced and handled safely prior to intentional detonation. This experiment utilizes an attenuation card of varying thicknesses between the initiator and the test article to attenuate the shock imparted, and a witness plate is analyzed for each test article to determine a GO or NO GO result. The data collected and the conclusions of this study affect how additives like HGMB are utilized in future explosive sensitivity threshold experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bending Stiffness of Multiwall Sandwich

An analytical and experimental study was carried out to understand the extensional and flexural behavior of multiwall sandwich, a metallic insulation composed of alternate layers of flat and dimpled foil. The multiwall sandwich was structurally analyzed by using several simplifying assumptions combined with a finite element analysis. The simplifying assumptions made in this analysis were evaluated by bending and tensile tests. Test results validate the assumption that flat sheets in compression do not significantly contribute to the flexural stiffness of multiwall sandwich for the multiwall geometry tested. However, calculations show that thicker flat sheets may contribute significantly to bending stiffness and cannot be ignored. Results of this analytical approach compare well with test data; both show that the extensional stiffness of the dimpled sheet in he 0 deg direction is about 30 percent of that for a flat sheet, and that in the 45 deg direction, it is about 10 percent. The analytical and experimental multiwall bending stiffness showed good agreement for the particular geometry tested.

Blosser, M. L.↗

The Strength of One-Piece Solid, Build-Up and Laminated Wood Airplane Wing Beams

The purpose of this report is to summarize the results of all wood airplane wing beams tested to date in the Bureau of Standards Laboratory in order that the various kinds of wood and methods of construction may be compared. All beams tested were of an I section and the majority were somewhat similar in size and cross section to the front wing beam of the Curtiss JN-4 machine. Construction methods may be classed as (1) solid beams cut from solid stock; (2) three-piece beams, built up of three pieces, web and flanges glued together by a tongue-and-groove joint and (3) laminated beams built up of thin laminations of wood glued together.

Nelson, John H↗

Texture Modification of the Shuttle Landing Facility Runway at Kennedy Space Center

This paper describes the test procedures and the criteria used in selecting an effective runway-surface-texture modification at the Kennedy Space Center (KSC) Shuttle Landing Facility (SLF) to reduce Orbiter tire wear. The new runway surface may ultimately result in an increase of allowable crosswinds for launch and landing operations. The modification allows launch and landing operations in 20-knot crosswinds, if desired. This 5-knot increase over the previous 15-knot limit drastically increases landing safety and the ability to make on-time launches to support missions in which Space Station rendezvous are planned. The paper presents the results of an initial (1988) texture modification to reduce tire spin-up wear and then describes a series of tests that use an instrumented ground-test vehicle to compare tire friction and wear characteristics, at small scale, of proposed texture modifications placed into the SLF runway surface itself. Based on these tests, three candidate surfaces were chosen to be tested at full-scale by using a highly modified and instrumented transport aircraft capable of duplicating full Orbiter landing profiles. The full-scale Orbiter tire testing revealed that tire wear could be reduced approximately by half with either of two candidates. The texture-modification technique using a Humble Equipment Company Skidabrader(trademark) shotpeening machine proved to be highly effective, and the entire SLF runway surface was modified in September 1994. The extensive testing and evaluation effort that preceded the selection of this particular surface-texture-modification technique is described herein.

Daugherty, Robert H.↗

Deployment, Foam Rigidization, and Structural Characterization of Inflatable Thin-Film Booms

Detailed investigation of the construction, packaging/deployment, foam rigidization, and structural characterization of polyimide film inflatable booms is described. These structures have considerable potential for use in space with solar concentrators, solar sails, space power systems including solar arrays, and other future missions. Numerous thin-film booms or struts were successfully constructed, inflated, injected with foam, and rigidized. Both solid-section and annular test articles were fabricated, using Kapton polyimide film, various adhesives, Styrofoam end plugs, and polyurethane pressurized foam. Numerous inflation/deployment experiments were conducted and compared to computer simulations using the MSC/DYTRAN code. Finite element models were developed for several foam-rigidized struts and compared to model test results. Several problems encountered in the construction, deployment, and foam injection/rigidization process are described. Areas of difficulty included inadequate adhesive strength, cracking of the film arid leakage, excessive bending of the structure during deployment, problems with foam distribution and curing properties, and control of foam leakage following injection into the structure. Many of these problems were overcome in the course of the research.

Schnell, Andrew R.↗

Matrix Cracking in 3D Orthogonal Melt-Infiltrated SiC/SiC Composites with Various Z-Fiber Types

The occurrence of matrix cracks in melt-infiltrated SiC/SiC composites with a 3D orthogonal architecture was determined at room temperature for specimens tested in tension oriented in the X-direction (parallel to Z-bundle weave direction) and Y-direction (perpendicular to Z-bundle weave direction) and Y-direction (perpendicular to Z-bundle weave direction). The fiber-types were Sylramic and Sylramic-IBN in the X and Y-directions and lower modulus ZMI, T300, and rayon in the Z-direction. Acoustic emission (AE) was used to monitor the matrix cracking activity. For Y-direction composites, the AE data was used to determine the exact (+/- 0.25 mm) location where matrix cracks occurred in the 3D orthogonal architecture. This enabled the determination of the stress-dependent matrix crack distributions for small but repeatable matrix rich 'unidirectional' and the matrix poor 'cross-ply' regions within the architecture. It was found that matrix cracking initiated at very low stresses (approx. 40 MPa) in the 'unidirectional' regions for the largest z-direction fiber tow composites. Decreasing the size of the z-fiber bundle, increased the stress for matrix cracking in the 'unidirectional' regions. Matrix cracking in the 'cross-ply' regions always occurred at higher stresses than in 'unidirectional' regions, and the stress-dependent matrix crack distribution of the 'cross-ply' regions was always over a wider stress-range than the 'unidirectional' regions. For composites tested in the X-direction, a lower elastic modulus and a narrower and lower stress-range for matrix cracking were observed compared to composites tested in the Y-direction.

Morscher, Gregory N.↗

Computer Generated Hologram System for Wavefront Measurement System Calibration

Computer Generated Holograms (CGHs) have been used for some time to calibrate interferometers that require nulling optics. A typical scenario is the testing of aspheric surfaces with an interferometer placed near the paraxial center of curvature. Existing CGH technology suffers from a reduced capacity to calibrate middle and high spatial frequencies. The root cause of this shortcoming is as follows: the CGH is not placed at an image conjugate of the asphere due to limitations imposed by the geometry of the test and the allowable size of the CGH. This innovation provides a calibration system where the imaging properties in calibration can be made comparable to the test configuration. Thus, if the test is designed to have good imaging properties, then middle and high spatial frequency errors in the test system can be well calibrated. The improved imaging properties are provided by a rudimentary auxiliary optic as part of the calibration system. The auxiliary optic is simple to characterize and align to the CGH. Use of the auxiliary optic also reduces the size of the CGH required for calibration and the density of the lines required for the CGH. The resulting CGH is less expensive than the existing technology and has reduced write error and alignment error sensitivities. This CGH system is suitable for any kind of calibration using an interferometer when high spatial resolution is required. It is especially well suited for tests that include segmented optical components or large apertures.

Olczak, Gene↗

Development of a Test for Evaluation of the Hydrothermal Stability of Sorbents Used in Closed-Loop CO2 Removal Systems

The International Space Station Carbon Dioxide Removal Assembly uses zeolite 5A molecular sieve material packed into beds for the capture of cabin CO2. The beds are cyclically heated to drive off the CO2 and restore the removal capacity. Over time, the sorbent material has been found to break down resulting in dust that restricts flow through the beds. Humidity adsorbed in the 5A zeolite when it is heated is a suspected cause of this sorbent degradation. To evaluate the impact of adsorbed water during thermal cycling, the Hydrothermal Stability Test was developed. The test configuration provides comparative side-by-side flow restriction data for two sorbent materials at specifically controlled humidity levels. While the initial focus of the testing is on 5A zeolite materials currently used on the ISS, the system will also be used to evaluate future candidate materials. This paper describes the approach, the test system, current results, and future testing.

Knox, James C.↗

HYDROPHOBIC CHARACTERISTICS OF COMPOSITE INSULATORS IN SIMULATED INLAND ARID DESERT ENVIRONMENT

Presently along with traditional insulators i.e. glass and porcelain, etc., the polymeric insulators are also used world widely. These polymeric insulators are very sensitive to various environmental parameters e.g. UV radiations, heat, etc. The UV radiation level in the central region of Saudi Arabia is high as compared to the recommended IEC-61109 standard for the accelerated aging of the composite insulators. In this study, thermoplastic elastomer (TPE) and Ethylene Propylene Diene Monomer (EPDM) insulators were subjected to accelerated aging stress as per IEC standard as well as modified IEC standard simulating the inland arid desert's atmospheric conditions. The hydrophobic characteristics were studied by measuring the contact angle along the insulator surface before and after the accelerated aging of the samples. It was found that TPE loses its hydrophobic properties more as compared to EPDM insulator. This loss was proportional to the intensity of UV irradiation. The rate of recovery is also low for both the tested materials as compared to Silicone Rubber insulators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Formulation of 8-moment plasma transport with application to the Nernst effect

8-moment plasma models using two different distribution functions are used to study the Nernst effect and heat transport in dense plasma. These models are presented in hyperbolic form in contrast to traditional parabolic systems derived from perturbing the distribution function, as in Braginskii [Rev. Plasma Phys. 1, 205 (1965)]. The hyperbolic moment formulation can be solved implicitly in time with straightforward and fast local solvers. The numerical implementation of 8-moment models with the relaxation method in the PERSEUS code is also presented. To test 8-moment PERSEUS compared to Braginskii’s transport equations, a verification test for the Nernst thermomagnetic wave by Velikovich et al. [Phys. Plasmas 26, 112702 (2019)] is performed that confirms the presence of the same physics, but with slight differences in the transport coefficients, which are tabulated in the limits of high and low magnetization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Temperature on Thrombogenicity Testing of Biomaterials in an In Vitro Dynamic Flow Loop System

To develop and standardize a reliable in vitro dynamic thrombogenicity test protocol, the key test parameters that could impact thrombus formation need to be investigated and understood. In this study, we evaluated the effect of temperature on the thrombogenic responses (thrombus surface coverage, thrombus weight, and platelet count reduction) of various materials using an in vitro blood flow loop test system. Whole blood from live sheep and cow donors was used to assess four materials with varying thrombogenic potentials: negative-control polytetrafluoroethylene (PTFE), positive-control latex, silicone, and high-density polyethylene (HDPE). Blood, heparinized to a donor-specific concentration, was recirculated through a polyvinyl chloride tubing loop containing the test material at room temperature (22–24°C) for 1 hour, or at 37°C for 1 or 2 hours. The flow loop system could effectively differentiate a thrombogenic material (latex) from the other materials for both test temperatures and blood species ( p < 0.05). However, compared with 37°C, testing at room temperature appeared to have slightly better sensitivity in differentiating silicone (intermediate thrombogenic potential) from the relatively thromboresistant materials (PTFE and HDPE, p < 0.05). These data suggest that testing at room temperature may be a viable option for dynamic thrombogenicity assessment of biomaterials and medical devices.

Engineering↗

Evaluation of a Seismic Event, 12 May 2010, in North Korea

We assess seismological evidence bearing on claims that North Korea conducted a small nuclear test on 12 May 2010 in the vicinity of known underground nuclear tests in 2006, 2009, 2013, and 2016. First, we use Lg -wave cross-correlation and more traditional methods to locate the 2010 event between about 4 and 10 km southwest of the 2009 test. Second, we compare the relative sizes of regional P-waves and S-waves, using stations within 400 km of the known North Korean nuclear tests, to assess the nature of the event. We measured P / S ratios at different frequencies, at first using data from the open station MDJ in northeast China, for training sets of earthquakes and of explosions. We developed a linear discriminant function (LDF), that, in application to P / S measured at MDJ, is most effective in separating the earthquake and explosion populations. MDJ lacks usable data for the event of interest, but we have obtained regional data from stations of the nearby Dongbei Broadband Seismographic Network (DBSN), for the event of 12 May 2010 and for nearby underground nuclear tests conducted in 2006 and 2009. When our LDF is applied to DBSN data, and to data from stations SMT and NE3C in China, the LDF values measured from P/S ratios from known explosions are explosion-like; but for the event of 12 May 2010 the LDF values are earthquake-like for frequencies between 6 and 12 Hz. Furthermore, our method for characterizing earthquakes and explosions on the basis of their regional signals can be widely applied. Measurements of P / S based upon three-component waveform data provide better discrimination power than do those based upon vertical-component data alone.

58 GEOSCIENCES↗

Incremental Slitting Residual Stress Measurements for a Hot Cell

This report describes investigations into applying the incremental slitting (a.k.a. crack compliance) method for measuring residual stress in the environment of a hot cell for future measurements of low enriched uranium (LEU) fuel plates coming out of a reactor. Results are reported for exploratory tests done at Los Alamos National Laboratory (LANL) on depleted uranium to check the most important experimental changes required for hot cell operation as compared to conventional testing. Further discussions detail other issues that need to be considered.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultimate FY23 Vacuum Creep Testing Facility Operation Report

This facility operation report covers the refurbishment and initial testing of a vacuum creep frame used to conduct 1300°C tensile and creep tests on Mo- and Nb-based alloys. The report details the refurbishment of the frame and initial operation including 100 h creep experiments compared to similar tests in argon. Unlike the 25 mm dogbone specimens tested in argon, the vacuum load train requires 76 mm dog bone specimens. Testing in vacuum has eliminated concern of O embrittlement in argon and Nb alloy CB103 showed >120% tensile elongation at 1300°C and 1450°C. Also, a window in the vacuum chamber allows the use of digital image correlation (DIC) to measure strain rather than the load train displacement used in the argon frames. Comparison of the displacement and DIC results in the vacuum frame showed significant variation in primary creep deformation, likely due to the machine compliance, but similar secondary creep rates. Recently, ULTIMATE teams have submitted specimens for testing in vacuum. With the relatively low volume of creep testing, the facility performance metric of testing within 4 weeks of receiving specimens has been met.

36 MATERIALS SCIENCE↗

Effects of Internal and External Heat Sources on Cladding Microstructure and Rupture Performance

In the event of a Loss of Coolant Accident (LOCA), the primary supply of cooling water for a nuclear reactor is lost, leading to a significant pressure differential across the cladding wall. Without adequate cooling, the fuel rods continue to heat as a result of fission reactions. Research at Oak Ridge National Laboratory’s (ORNL’s) Severe Accident Test Station (SATS) is currently focused on evaluating fuel cladding performance using an external infrared lamp as a heat source, whereas legacy testing primarily utilized an internal heating approach. While external heating may better simulate the effect of neighboring fuel rods heating a central rod, it may not accurately represent the internal heat absorption from the fuel during accident transients. The heating dynamics depend greatly on the fuel rod's position within the bundle and the reactor. To fully understand the implications of a LOCA event and assess the influence of internal heating on cladding performance, combined internal heating and pressurization capability was developed at ORNL. Tests were conducted to compare cladding segments heated internally (representing heat from the fuel within the rod) and externally (representing heat from adjacent fuel rods). The findings indicate that both internal and external heating result in comparable rupture temperatures during 5°C/s laboratory LOCA tests and also agree with legacy test data. Axial temperature gradients and internal heat source dispersal were found to significantly impact cladding deformation and rupture geometry. Clear modifications were outlined to further improve the capability with heating rates above 5°C/s.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗