Development of Semiconductor Imaging Detectors for a Si/CdTe Compton Camera
Abstract Not Provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract Not Provided
Significant temperature rise and gradient are observed from a GaAs photo-cathode wafer irradiated at various power levels with over 20W laser power at 532nm wavelength. The laser power absorption and dissipated thermal distribution are measured. The result shows a clear indication that proper removal of laser induced heat from the cathode needs to be considered seriously when designing a high average current or low quantum efficiency photo-cathode electron gun. The measurement method presented here provides a useful way to obtain information about both temperature and thermal profiles, it also applies to cathode heating study with other heating devices such as electrical heaters.
Not Available
Not Available
CdZnTe (CZT) crystals with thicknesses up to 20 mm and diameters up to 75 mm have become available from Redlen Technologies, Inc. for making large-volume gamma-ray detectors. The modified growth and optimized annealing conditions allowed Redlen to minimize the dark current and improve the uniformity of CZT crystals. Two detector designs, pixelated (H3D) and position-sensitive virtual Frisch-grid (VFG), have greatly benefitted from the availability of such big crystals. Encouraging results from testing of 40×40×15 mm 3 pixelated detectors were recently reported by the University of Michigan. In this work, we evaluated the spectroscopic properties of 8×8×32 and 10×10×32 mm 3 crystals configured as position-sensitive VFG detectors. Both digitized waveforms and an analog ASIC were used to read and process the signals from the detectors and test their spectral- and spatial-resolution. The VFG design provides the flexibility to scale-up the dimensions of the detectors for the desired efficiency, while the position information allows for correcting the detectors' response non-uniformity caused by crystal defects and devices geometry, thereby reducing the instrument cost and making them more feasible for emerging applications in gamma-ray astronomy, nonproliferation, portal screening and nuclear safeguards, where large detector arrays are often required.
Not Available
Not Available
Not Available
The recent development of microcrystal electron diffraction (MicroED) in electron cryo-microscopy (cryo-EM) has addressed many of the challenges of X-ray crystallography [1], filling a long-standing need in organic chemistry for rapid and accurate high-resolution structural characterization [2]. Like X-ray crystallography, this is also a diffraction technique requiring crystalline specimens, but because high energy electrons have a more favorable ration of elastic to inelastic scattering [3], MicroED can acquire data using crystals that are orders of magnitude smaller than those needed for X-ray crystallography—even as small as 50 nm in length [4]. Additionally, the instrumentation required for MicroED is readily available, as many chemistry and biology labs already have access to cryo-capable transmission electron microscopes (TEM).
Abstract not provided.
Here, functional materials and devices are usually morphologically complex and chemically heterogeneous. Their structures are often designed to be hierarchical because of the desired functionalities, which usually require many different components to work together in a coherent manner. The lithium ion battery, as an energy storage device, is a very typical example of this kind of structure. In a lithium ion battery, the cathode, anode, and separator are soaked in a liquid electrolyte, facilitating the back and forward shuttling of the lithium ions for energy storage and release. The desired performance of a lithium ion battery has many different aspects that need to be engineered and balanced depending on the targeted applications. In most cases, the cathode material has become the limiting factor for further improvements and, thus, has attracted intense attention from the research community.
Not Available
Not Available
Isolated proton auroras (IPAs) appearing at subauroral latitudes are generated by energetic protons precipitating from the magnetosphere through interaction with electromagnetic ion cyclotron (EMIC) waves. An IPA thus indicates the spatial scale and temporal variation of wave-particle interactions in the magnetosphere. In this study, a unique event of simultaneous ground and magnetospheric satellite observations of two IPAs were conducted on March 16, 2015, using an all-sky imager at Athabasca, Canada and Van Allen Probes. The Van Allen Probes observed two isolated EMIC waves with frequencies of ~1 and 0.4 Hz at L ≈ 5.0 when the satellite footprint crossed over the two IPAs. This suggests that the IPAs were caused by localized EMIC waves. Proton flux at 5–20 keV increased locally when the EMIC waves appeared. Electron flux at energies below ~500 eV also increased. Temperature anisotropy of the energetic protons was estimated at 1.5–2.5 over a wide L-value range of 3.0–5.2. Electron density gradually decreased from L = 3.5 to 5.4, suggesting that the EMIC wave at L ≈ 5.0 was located in the gradual plasmapause. From these observations, we conclude that the localized IPAs and associated EMIC waves took place because of localized enhancement of energetic proton flux and plasma density structure near the plasmapause. Furthermore, the magnetic field observed by the satellite showed small variation during the wave observation, indicating that the IPAs were accompanied by the weak field-aligned current.
Not Available
A 1D space resolving x-ray spectrum diagnostic system has been developed to study the radiation opacity of hot plasma on SG-II laser facility. The diagnostic system consists of a 2400 lines/mm flat-field holographic grating and a gated microchannel plate coupled with an optical CCD and covers the wavelength range of 5-50 A. The holographic grating was compared with a ruled one by measuring the emission spectra from a laser-produced molybdenum plasma. The results indicate that the holographic grating possesses better sensitivity than the ruled grating having nearly similar spectral resolution. The spectrograph has been used in radiative opacity measurement of Fe plasma. Simultaneous measurements of the backlight source and the transmission spectrum in appointed time range in one shot have been accomplished successfully with the holographic grating spectrometer. The 2p-3d transition absorption of Fe plasma near 15.5A in has been observed clearly.
Abstract not provided