SEARCH · Engineering Papers
Results for “Automating”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Managing connected and automated vehicles at isolated intersections: From reservation- to optimization-based methods
Not provided.
Life cycle greenhouse gas impacts of a connected and automated SUV and van
Not Available
3D reconstruction of the spatial distribution of dislocation loops using an automated stereo-imaging approach
Not Available
Automated pipeline for atlas-based annotation of gene expresssion patterns: application to postnatal day 7 mouse brain
Abstract As bio-medical images and volumes are being collected at an increasing speed, there is a growing demand for efficient means to organize spatial information for comparative analysis. In many scenarios, such as determining gene expression patterns by in situ hybridization, the images are collected from multiple subjects over a common anatomical region, such as the brain. A fundamental challenge in comparing spatial data from different images is how to account for the shape variations among subjects, which makes direct image-to-image comparison meaningless. In this paper, we describe subdivision meshes as a geometric means to efficiently organize 2D images and 3D volumes collected from different subjects for comparison. The key advantages of a subdivision mesh for this purpose are its light-weight geometric structure and its explicit modeling of anatomical boundaries, which enable efficient and accurate registration. The multi-resolution structure of a subdivision mesh also allows development of fast comparison algorithms among registered images and volumes.
Automated characterization of debonding based on ultrasonic guided waves and a simulation-trained deep neural network
Not Available
Improving Image Quality and Reducing Drift Problems via Automated Data Acquisition and Averaging in Cs-corrected TEM
Image acquisition with a CCD camera is a single-press-button activity: after selecting exposure time and adjusting illumination, a button is pressed and the acquired image is perceived as the final, unmodified proof of what was seen in the microscope. Thus it is generally assumed that the image processing steps of e.g., 'dark-current correction' and 'gain normalization' do not alter the information content of the image, but rather eliminate unwanted artifacts. Image quality therefore is, among a long list of other parameters, defined by the dynamic range of the CCD camera as well as the maximum allowable exposure time depending on sample drift (ignoring sample damage). Despite the fact that most microscopists are satisfied with present, standard image quality we found that it is a relatively easy to improve on existing routines in at least two aspects: (1) Suppression of lateral image drift during acquisition by using significantly shorter exposure times with a plurality of exposures (3D-data set); and (2) Improvement in the Signal/Noise ratio by averaging over a given data set by exceeding the dynamic range of the camera.
PRACTICAL UTILIZATION OF A URANIUM-CONTAINING PARTICULATE TEST SAMPLES FOR SEM/EDS AND SIMS AUTOMATED PARTICLE ANALYSIS METHOD VALIDATION
Explore the source record for details and available documents.
Automated methods for improved characterization of alloy nanoparticle catalysts
Explore the source record for details and available documents.
Atomic-scale Fabrication of 1D-2D Nano Hetero-structures within 2D Materials through Automated Tracking and Electron Beam Control
Explore the source record for details and available documents.
Seamless Communication Between High-Performance Computing System and Electron Microscopes for On-Demand Automated Data Transfer and Remote Control
Explore the source record for details and available documents.
Improved Throughput, Statistics, and Instrument Utilization with Automated Analytical Electron Microscopy
Explore the source record for details and available documents.
Automated Gain Control Ion Funnel Trap for Orthogonal Time-of-Flight Mass Spectrometry
Time-of-flight mass spectrometry (TOF MS) is increasingly used in proteomics research. Herein, we report on the development and characterization of an ultra-sensitive TOF MS instrument equipped with an electrodynamic ion funnel trap (IFT) that employs an automatic gain control (AGC) capability. The IFT-TOF MS was coupled to a reverse-phase capillary liquid chromatography (RPLC) separation and evaluated in experiments with complex proteolytic digests. When applied to a global tryptic digest of Shewanella oneidensis proteins, an order-of-magnitude increase in sensitivity compared to that of the conventional continuous mode of operation was achieved due to efficient ion accumulation prior to TOF MS analysis. As a result of this sensitivity improvement and related improvement in mass measurement accuracy, the number of unique peptides identified in the AGC-IFT mode was 5-fold greater than that obtained in the continuous mode.
Rapid Automated Annotation and Analysis of N-Glycan Mass Spectrometry Imaging Data Sets Using NGlycDB in METASPACE
Imaging N-glycan spatial distribution in tissues using mass spectrometry imaging (MSI) is emerging as a promising tool in biological and clinical applications. However, there is currently no high throughput tool for visualization and molecular annotation of N-glycans in MSI data, which significantly slows down data processing and hampers the applicability of this approach. In this work, we present how METASPACE, an open-source cloud engine for molecular annotation of MSI data, can be used to automatically annotate, visualize, analyze, and interpret high-resolution mass spectrometry-based spatial N-glycomics data. METASPACE is an emerging tool in spatial metabolomics, but the lack of compatible glycan databases has limited its application for comprehensive N-glycan annotations from MSI datasets. We created NGlycDB, a public database of N-glycans, by adapting available glycan databases. We demonstrate the applicability of NGlycDB in METASPACE by analyzing MALDI-MSI data from formalin-fixed paraffin-embedded (FFPE) human kidney and mouse lung tissue sections. We added NGlycDB to METASPACE for public use, thus facilitating applications of MSI in glycobiology.
Hard Potato: A Python Library to Control Commercial Potentiostats and to Automate Electrochemical Experiments
Not Available