Application of a headspace GC–MS method to evaluate the product quality of alcohol‐based hand wipe sanitizers

Abstract The investigation of marketed hand wipe sanitizers presented an analytical challenge owing to the need for extraction from the solid matrix of the products. The present work describes the development of a new sample preparation method for the extraction of analytes from the hand wipe sanitizer matrix into dimethyl sulfoxide for analysis using headspace GCMS. Alcohol‐based hand sanitizer (ABHS) wipe products labeled to contain ethanol or isopropanol as active ingredients were tested, varying in the size and weight of the wipes. The spike recovery assay was confirmed using spiking solutions containing impurities at concentrations equivalent to 50, 100 and 200% of the interim concentration limits. All of the tested analytes showed recovery within the allowable limits (80–120%). Six marketed ABHS wipe products were tested and no impurities above the FDA interim limits were observed. One product contained ethanol below the 60% v/v limit and another product was mislabeled for isopropanol and was found to contain ethanol instead. Four of the six ABHS products did not meet the label claim, which may affect the product quality. The analytical method and sample preparation procedures will provide the FDA and ABHS manufacturers with the capability to conduct quality assurance testing of hand wipe sanitizers for active ingredient content and impurities.

Biochemistry & Molecular Biology↗

A diagrammatic approach for automatically deriving analytical gradients of tensor hyper-contracted electronic structure methods

In this work, we introduce a diagrammatic approach to facilitate the automatic derivation of analytical nuclear gradients for tensor hyper-contraction (THC) based electronic structure methods. The automatically derived gradients are guaranteed to have the same scaling in terms of both operation count and memory footprint as the underlying energy calculations, and the computation of a gradient is roughly three times as costly as the underlying energy. The new diagrammatic approach enables the first cubic scaling implementation of nuclear derivatives for THC tensors fitted in molecular orbital basis (MO-THC). Furthermore, application of this new approach to THC-MP2 analytical gradients leads to an implementation, which is at least four times faster than the previously reported, manually derived implementation. Finally, we apply the new approach to the 14 tensor contraction patterns appearing in the supporting subspace formulation of multireference perturbation theory, laying the foundation for developments of analytical nuclear gradients and nonadiabatic coupling vectors for multi-state CASPT2.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technical Note: On the proton range and nuclear interactions in compounds and mixtures

Purpose: Range and probability of nonelastic nuclear interactions (NNIs) for protons can be found only for a limited number of compounds and mixtures in nuclear data tables, and the proton-related analytical studies are therefore restricted to those materials for which the data are provided in these documents. In this paper, the authors present general solutions for calculating the proton range and probability of NNIs for desired compounds and mixtures. Methods: Benefiting from the Bragg–Kleeman approximation of mass stopping power, the authors derive a concise formula for calculating the proton range in materials with arbitrary number of constituent elements. Additionally, the authors propose another relation for obtaining the probability of undergoing NNIs which is suggested to be additive. Results: The examination of the formula presented shows that the authors’ method can be considered as general solutions for analytical evaluation of the range in compounds and mixtures. The formula proposed for probability of NNIs is valid for almost every compound except for those materials containing H. It is shown that this formula can be modified so that it covers these materials. Conclusions: The authors present a general analytical method for calculating the range and probability of NNIs for protons which are mathematically easy to handle and valid for desired compounds or mixtures composed of an arbitrary number of constituent elements, including materials of interest for proton radiotherapy purposes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Derivation of general analytic gradient expressions for density-fitted post-Hartree-Fock methods: An efficient implementation for the density-fitted second-order Møller–Plesset perturbation theory

General analytic gradient expressions (with the frozen-core approximation) are presented for density-fitted post-HF methods. An efficient implementation of frozen-core analytic gradients for the second-order Møller–Plesset perturbation theory (MP2) with the density-fitting (DF) approximation (applying to both reference and correlation energies), which is denoted as DF-MP2, is reported. The DF-MP2 method is applied to a set of alkanes, conjugated dienes, and noncovalent interaction complexes to compare the computational cost of single point analytic gradients with MP2 with the resolution of the identity approach (RI-MP2) [F. Weigend and M. Häser, Theor. Chem. Acc. 97, 331 (1997); R. A. Distasio, R. P. Steele, Y. M. Rhee, Y. Shao, and M. Head-Gordon, J. Comput. Chem. 28, 839 (2007)]. In the RI-MP2 method, the DF approach is used only for the correlation energy. Our results demonstrate that the DF-MP2 method substantially accelerate the RI-MP2 method for analytic gradient computations due to the reduced input/output (I/O) time. Because in the DF-MP2 method the DF approach is used for both reference and correlation energies, the storage of 4-index electron repulsion integrals (ERIs) are avoided, 3-index ERI tensors are employed instead. Further, as in case of integrals, our gradient equation is completely avoid construction or storage of the 4-index two-particle density matrix (TPDM), instead we use 2- and 3-index TPDMs. Hence, the I/O bottleneck of a gradient computation is significantly overcome. Therefore, the cost of the generalized-Fock matrix (GFM), TPDM, solution of Z-vector equations, the back transformation of TPDM, and integral derivatives are substantially reduced when the DF approach is used for the entire energy expression. Further application results show that the DF approach introduce negligible errors for closed-shell reaction energies and equilibrium bond lengths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating marginal likelihood with thermodynamic integration method and comparison with several other numerical methods

Evaluating marginal likelihood is the most critical and computationally expensive task, when conducting Bayesian model averaging to quantify parametric and model uncertainties. The evaluation is commonly done by using Laplace approximations to evaluate semianalytical expressions of the marginal likelihood or by using Monte Carlo (MC) methods to evaluate arithmetic or harmonic mean of a joint likelihood function. This study introduces a new MC method, i.e., thermodynamic integration, which has not been attempted in environmental modeling. Instead of using samples only from prior parameter space (as in arithmetic mean evaluation) or posterior parameter space (as in harmonic mean evaluation), the thermodynamic integration method uses samples generated gradually from the prior to posterior parameter space. This is done through a path sampling that conducts Markov chain Monte Carlo simulation with different power coefficient values applied to the joint likelihood function. The thermodynamic integration method is evaluated using three analytical functions by comparing the method with two variants of the Laplace approximation method and three MC methods, including the nested sampling method that is recently introduced into environmental modeling. The thermodynamic integration method outperforms the other methods in terms of their accuracy, convergence, and consistency. The thermodynamic integration method is also applied to a synthetic case of groundwater modeling with four alternative models. The application shows that model probabilities obtained using the thermodynamic integration method improves predictive performance of Bayesian model averaging. As a result, the thermodynamic integration method is mathematically rigorous, and its MC implementation is computationally general for a wide range of environmental problems.

97 MATHEMATICS AND COMPUTING↗

Extraction efficiency and implications for absolute quantitation of propranolol in mouse brain, liver and kidney thin tissue sections using droplet-based liquid microjunction surface sampling-HPLC ESI-MS/MS

Currently, absolute quantitation aspects of droplet-based surface sampling for thin tissue analysis using a fully automated autosampler/HPLC-ESI-MS/MS system are not fully evaluated. Knowledge of extraction efficiency and its reproducibility is required to judge the potential of the method for absolute quantitation of analytes from thin tissue sections. Methods: Adjacent thin tissue sections of propranolol dosed mouse brain (10- μm-thick), kidney (10- μm-thick) and liver (8-, 10-, 16- and 24- μm-thick) were obtained. Absolute concentration of propranolol was determined in tissue punches from serial sections using standard bulk tissue extraction protocols and subsequent HPLC separations and tandem mass spectrometric analysis. These values were used to determine propranolol extraction efficiency from the tissues with the droplet-based surface sampling approach. Results: Extraction efficiency of propranolol using 10- μm-thick brain, kidney and liver thin tissues using droplet-based surface sampling varied between ~45-63%. Extraction efficiency decreased from ~65% to ~36% with liver thickness increasing from 8 μm to 24 μm. Randomly selecting half of the samples as standards, precision and accuracy of propranolol concentrations obtained for the other half of samples as quality control metrics were determined. Resulting precision ( ±15%) and accuracy ( ±3%) values, respectively, were within acceptable limits. In conclusion, comparative quantitation of adjacent mouse thin tissue sections of different organs and of various thicknesses by droplet-based surface sampling and by bulk extraction of tissue punches showed that extraction efficiency was incomplete using the former method, and that it depended on the organ and tissue thickness. However, once extraction efficiency was determined and applied, the droplet-based approach provided the required quantitation accuracy and precision for assay validations. Furthermore, this means that once the extraction efficiency was calibrated for a given tissue type and drug, the droplet-based approach provides a non-labor intensive and high-throughput means to acquire spatially resolved quantitative analysis of multiple samples of the same type.

59 BASIC BIOLOGICAL SCIENCES↗

CRADA Final Report: Weld Predictor App

Welding is an important manufacturing process used in a broad range of industries and market sectors, including automotive, aerospace, heavy manufacturing, medical, and defense. During welded fabrication, high localized heat input and subsequent rapid cooling result in the creation of residual stresses and distortion. These residual stresses can significantly affect the fatigue resistance, cracking behavior, and load-carrying capacity of welded structures during service. Further, additional fitting and tacking time is often required to fit distorted subassemblies together, resulting in non-value added cost. Using trial-and-error methods to determine which welding parameters, welding sequences, and fixture designs will most effectively reduce distortion is a time-consuming and expensive process. For complex structures with many welds, this approach can take several months. For this reason, efficient and accurate methods of mitigating distortion are in-demand across all industries where welding is used. Analytical and computational methods and commercial software tools have been developed to predict welding-induced residual stresses and distortion. Welding process parameters, fixtures, and tooling can be optimized to reduce the HAZ softening and minimize weld residual stress and distortion, improving performance and reducing design, fabrication and testing costs. However, weld modeling technology tools are currently accessible only to engineers and designers with a background in finite element analysis (FEA) who work with large manufacturers, research institutes, and universities with access to high-performance computing (HPC) resources. Small and medium enterprises (SMEs) in the US do not typically have the human and computational resources needed to adopt and utilize weld modeling technology. To allow an engineer with no background in FEA and SMEs to gain access to this important design tool, EWI and the Ohio Supercomputer Center (OSC) developed the online weld application software tool “WeldPredictor” ( https://eweldpredictor.ewi.org ). About 1400 users have tested this application. This project marked the beginning of development on the next version of WeldPredictor that addresses many outstanding features of the original, including 3D models, allow more material hardening laws, model material phase transformation, and uses open source finite element solvers to quickly solve problems (as opposed to expensive commercial tools).

42 ENGINEERING↗

Analytical energy gradient based on spin-free infinite-order Douglas-Kroll-Hess method with local unitary transformation

In this study, the analytical energy gradient for the spin-free infinite-order Douglas-Kroll-Hess (IODKH) method at the levels of the Hartree-Fock (HF), density functional theory (DFT), and second-order Møller-Plesset perturbation theory (MP2) is developed. Furthermore, adopting the local unitary transformation (LUT) scheme for the IODKH method improves the efficiency in computation of the analytical energy gradient. Numerical assessments of the present gradient method are performed at the HF, DFT, and MP2 levels for the IODKH with and without the LUT scheme. The accuracies are examined for diatomic molecules such as hydrogen halides, halogen dimers, coinage metal (Cu, Ag, and Au) halides, and coinage metal dimers, and 20 metal complexes, including the fourth–sixth row transition metals. In addition, the efficiencies are investigated for one-, two-, and three-dimensional silver clusters. The numerical results confirm the accuracy and efficiency of the present method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical pseudomotors for soft x-ray beamlines

Optical elements of soft x-ray beamlines usually have motorized translations and rotations that allow for the fine alignment of the beamline. This is to steer the photon beam at some positions and to correct the focus on slits or on sample. Generally, each degree of freedom of a mirror induces a change of several parameters of the beam. Inversely, several motions are required to actuate on a single optical parameter, keeping the others unchanged. We define optical pseudomotors as combinations of physical motions of the optical elements of a beamline, which allow modifying one optical parameter without affecting the others. We describe a method to obtain analytic relationships between physical motions of mirrors and the corresponding variations of the beam parameters. This method has been implemented and tested at two beamlines at ALBA, where it is used to control the focus of the photon beam and its position independently.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast methods for multisite charge transfer. Processes II. Analytic nuclear gradients and nonadiabatic dynamics for cCASSCF(1,n) and cCASSCF(2n-1,n) wavefunctions

In this work we derive and implement analytic nuclear gradients and derivative couplings for a constrained complete active space self-consistent field with a small active space designed to model electron or hole transfer. Using a Lagrangian formalism, we are able to differentiate both the CASSCF energy and the constraint (which is required for smooth surfaces over a wide range of parameter space), and the resulting efficient algorithm can be immediately applied to nonadiabatic dynamics simulations of charge transfer processes. Here, we run initial surface-hopping simulations of a proton coupled electron transfer event for a phenoxyl–phenol system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multithreaded parallelization of the energy and analytic gradient in the fragment molecular orbital method

The fragment molecular orbital method in GAMESS is parallelized in a multithreaded OpenMP implementation combined with the MPI version of the two-level generalized distributed data interface. The energy and analytic gradient in gas phase and the polarizable continuum model of solvation are parallelized in this hybrid three-level scheme, achieving a large memory footprint reduction and a high parallel efficiency on Intel Xeon Phi processors. The parallel efficiency is demonstrated on the Stampede2 and Theta supercomputers using up to 2048 nodes (262 144 threads).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-AB-207B-06: Dose and Biological Uncertainties in Sarcoma

Purpose: To understand the clinical impact of key uncertainties in proton therapy potentially affecting the analysis of clinical trials, namely the assumption of using a constant relative biological effectiveness (RBE) of 1.1 compared to variable RBE for proton therapy and the use of analytical dose calculation (ADC) methods. Methods: Proton dose distributions were compared for analytical and Monte Carlo (TOPAS) dose calculations. In addition, differences between using a constant RBE of 1.1 (RBE-constant) were compared with four different RBE models (to assess model variations). 10 patients were selected from an ongoing clinical trial on IMRT versus scanned protons for sarcoma. Comparisons were performed using dosimetric indices based on dose-volume histogram analyses and γ-index analyses. Results: For three of the RBE-models the mean dose, D95, D50 and D02 (dose values covering 95%, 50% and 2% of the target volume, respectively) were up to 5% lower than for RBE-constant. The dosimetric indices for one of the RBE-models were around 9% lower than for the RBE-constant model. The differences for V90 (the percentage of the target volume covered by 90% of the prescription dose) were up to 40% for three RBE-models, whereas for one the difference was around 95%. All ADC dosimetric indices were up to 5% larger than for RBE-constant. The γ-index passing rate for the target volume with a 3%/3mm criterion was above 97% for all models except for one, which was below 24%. Conclusion: Interpretation of clinical trials on sarcoma may depend on dose calculation uncertainties (as assessed by Monte Carlo). In addition, the biological dose distribution depends notably on which RBE model is utilized. The current practice of using a constant RBE of 1.1 may overestimate the target dose by as much as 5% for biological dose calculations. Performing an RBE uncertainty analysis is recommended for trial analysis. U19 projects - U19 CA 021239. PI: Delaney.

60 APPLIED LIFE SCIENCES↗

Steady-state properties of multi-orbital systems using quantum Monte Carlo

A precise dynamical characterization of quantum impurity models with multiple interacting orbitals is challenging. In quantum Monte Carlo methods, this is embodied by sign problems. A dynamical sign problem makes it exponentially difficult to simulate long times. A multi-orbital sign problem generally results in a prohibitive computational cost for systems with multiple impurity degrees of freedom even in static equilibrium calculations. Here, we present a numerically exact inchworm method that simultaneously alleviates both sign problems, enabling simulation of multi-orbital systems directly in the equilibrium or nonequilibrium steady-state. The method combines ideas from the recently developed steady-state inchworm Monte Carlo framework [Erpenbeck et al., Phys. Rev. Lett. 130, 186301 (2023)] with other ideas from the equilibrium multi-orbital inchworm algorithm [Eidelstein et al., Phys. Rev. Lett. 124, 206405 (2020)]. We verify our method by comparison with analytical limits and numerical results from previous methods.

Chemistry↗

Coupling TRACE with nodal neutronics code Ants using the Exterior Communications Interface and VTT's multi-physics driver Cerberus

In this paper a recently developed coupling between system code TRACE and nodal neutronics code Ants is presented. The TRAC/RELAP Advanced Computational Engine (TRACE) is a reactor system code developed by U.S. Nuclear Regulatory Commission (NRC). The code has been designed to analyse loss-of-coolant accidents (LOCAs), operational transients and other accident scenarios in light water reactors. Ants is the reduced order nodal neutronics code of the Kraken framework. The diffusion solution method in Ants is based on the Analytic Function Expansion Nodal method (AFEN) and Flux Expansion Nodal Method (FENM). Rectangular, hexagonal and triangular geometries are supported. Both steady state and burnup problems including micro-depletion can be simulated. The coupling is implemented using VTT's multi-physics driver Cerberus and the Exterior Communications Interface (ECI) which is supplied with TRACE and enables the coupling of TRACE without source code modifications. The main focus in the paper is on describing the TRACE-Ants coupling in detail in order to share to other code developers what we have learned from the ECI based coupling process. The coupled code system is briefly tested by simulating a simple transient in a SMR core initiated by control rod movement. The results of the test calculation look reasonable and more complicated test cases will be modelled in the near future.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Temperature Profile in Fuel and Tie-Tubes for Nuclear Thermal Propulsion Systems

A finite element method to calculate temperature profiles in heterogeneous geometries of tie-tube moderated LEU nuclear thermal propulsion systems and HEU designs with tie-tubes is developed and implemented in MATLAB. This new method is compared to previous methods to demonstrate shortcomings in those methods. Typical methods to analyze peak fuel centerline temperature in hexagonal geometries rely on spatial homogenization to derive an analytical expression. These methods are not applicable to cores with tie-tube elements because conduction to tie-tubes cannot be accurately modeled with the homogenized models. The fuel centerline temperature directly impacts safety and performance so it must be predicted carefully. The temperature profile in tie-tubes is also important when high temperatures are expected in the fuel because conduction to the tie-tubes may cause melting in tie-tubes, which may set maximum allowable performance. Estimations of maximum tie-tube temperature can be found from equivalent tube methods, however this method tends to be approximate and overly conservative. A finite element model of heat conduction on a unit cell can model spatial dependence and non-linear conductivity for fuel and tie-tube systems allowing for higher design fidelity of Nuclear Thermal Propulsion.

33 ADVANCED PROPULSION SYSTEMS↗

Advancing Enhanced Raman Spectroscopy to Detect and Measure NOW Pheromones (CPRB 2022 proposal)

Insect sex pheromones are chemical compounds that insects release to attract their partners over distances of hundreds of meters or even kilometers, in complete darkness and without any audible signals. Use of synthetic forms of key compounds have in some cases become an essential component of monitoring and/or managing key pests of agricultural crops, including navel orangeworm (Amyelois transitella) (NOW) in California tree nuts. These pheromone-based strategies can include monitoring, mating disruption, mass trapping, attract-and-kill and push-pull. There are currently multiple commercially available mating disruption products available for NOW and recent studies have demonstrated that they can be effectively used to reduce crop damage by this pest. Just how mating disruption works is not fully established and likely varies across products and target species. For instance, the extent to which synthetic pheromones compete with natural pheromone is not well understood, or in the case of monitoring, how efficaciously the insect follows the diffusing plumes, especially across large blocks and at plot borders. Furthermore, there may be specific conditions under which poor or impeded diffusion of synthetic pheromone diminishes the disruption effect, which could result in some males effectively locating females for reproduction. At the same time, many commercially available synthetic lures are also available, and growers have been effectively using them to track population development – although the attractive range of these lures remains unclear. That is, while pheromone lures can attract many moths, the relationship between trap capture and local populations, much less crop damage, remains unclear. Regardless of the emission source (aerosol puffers, meso emitters, lures etc.), we currently lack the ability to fully understand how these synthetic pheromone compounds diffuse away from their point-source of emission – and subsequently how this might affect the efficacy of mating disruption and/or the accuracy of monitoring efforts. Raman spectroscopy (RS) may offer a means to detect synthetic pheromone because of its analytical properties and recent technological advancements. In combination with nanostructured probes, RS has a demonstrated capability to detect volatiles at extremely low concentrations. While other methods for detecting pheromones have proven to be successful, such analytical methods like mass spectrometry (MS) gas chromatography (GC) require sampling in the fields and are not real-time. Other methods such as EAG/ EAD are also invasive (use antennas) but are of course valuable. Opto-electronic, micro and nano sensors just recently enticed interest. We fall in this latter category, proposing the use of optical spectroscopy (Raman) in a fiber aided by nanostructures to provide a chemical fingerprint without transductions and in real-time (i.e. no sampling). To date, we have been able to generate Raman signatures for the main chemicals in synthetic pheromones (a first for science, to the best of our knowledge), observe their trends at different concentrations, and also provide a clear distinction of such signatures in mixed samples via Principal Component Analysis (PCA) – all of which strengthens our conclusions on the ability of RS to detect emissions in more realistic conditions. We also established processes to enhance the detection sensitivity via preconcentration with Solid Phase Micro Extraction (SPME) fibers and Surface Enhanced Raman Spectroscopy (SERS) to increase the overall optical signals. Furthermore, we explored limitations and requirements for detecting from dispensers, lures, or live moths, including Dept. of Energy and CA State regulatory approvals. Finally, we setup some of our first “orchard in a box” experiments to measure pheromone diffusion along with developing appropriate models.

42 ENGINEERING↗

Kink model of state switching in quasi-one-dimensional nanosystems

A method for the analytical calculation of the kinetics of state switching induced by external field in quasi-one-dimensional systems has been developed. This method is based on the Kolmogorov approach, which was proposed to describe statistical crystallization. As applied to magnetic systems, it allows one to calculate magnetization curves and hysteresis loops. The results of analytical calculation are confirmed by stochastic Monte Carlo simulation, which also makes it possible to find characteristics of mixed domain states formed as a result of the multiple cycling of the external field amplitude.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analytic error analysis of cross section interpolation methods in nodal diffusion codes - II: Numerical results

This paper is the second part of a two-part paper that documents the numerical results for the partial derivatives model presented in part I. In this paper, we derive the error bounds for the analytical point-wise error expression and verify our bounds with numerical experiments. The point-wise error expressions make available, and bound, the sources that contribute to the total error of the interpolated cross section in terms of the Lagrange interpolation errors and the model form error. MPACT is used to generate two-group homogenized cross sections for Westinghouse's AP1000 Region 4 lattice to evaluate the accuracy of the bounds. Error bounds calculated over a grid are compared to numerical data for uni-variate and multi-variate interpolation. The point-wise error bounds of a typical case matrix - two branches in each state variable - are displayed for bi-variate interpolation in the state variables: moderator density, fuel temperature, and boron concentration. The error bounds are shown to be highly accurate compared to numerical results, and in accordance with the underlying physics. We then discuss and show how the sources of error contribute to the total error, and consider the improvement of each error source. Finally, we mention future work such as propagating our cross section error bounds through a reactivity calculation. (authors)