Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTERIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Angioplasty or Primary Stenting for Infrapopliteal Lesions: Results of a Prospective Randomized Trial

Excellent results with small stents in coronary arteries have led endovascular therapists to their use in infrapopliteal vessels. However, to date no level I evidence exists to recommend primary stenting over infrapopliteal angioplasty alone. The aim of this randomized single-center trial was to compare their 1-year outcome. A total of 38 limbs in 35 patients with critical limb ischemia were randomized to angioplasty (22 pts) or primary stenting (16 pts). Target lesions were infrapopliteal occluded (36) or stenotic (20) lesions ranging from <2 to >15 cm in length. The mean age was 72 years. At 12 months, there was no statistical difference in survival (angioplasty, 69.3%; primary stenting, 74.7%), in limb salvage (angioplasty, 90%; primary stenting, 91.7%), or in primary and secondary patency (angioplasty, 66 and 79.5%; primary stenting, 56 and 64%) between the groups Renal insufficiency was the only significant negative predicting factor for limb salvage in both groups. In conclusion, the 1-year results for both groups were broadly similar. Stenting has its place in infrapopliteal angioplasty if the procedure is jeopardized by a dissection or recoil, but our results do not support primary stenting in all cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT Fluoroscopy-Guided Lung Biopsy with Novel Steerable Biopsy Canula: Ex-Vivo Evaluation in Ventilated Porcine Lung Explants

The purpose was to evaluate ex-vivo a prototype of a novel biopsy canula under CT fluoroscopy-guidance in ventilated porcine lung explants in respiratory motion simulations. Using an established chest phantom for porcine lung explants, n = 24 artificial lesions consisting of a fat-wax-Lipiodol mixture (approx. 70HU) were placed adjacent to sensible structures such as aorta, pericardium, diaphragm, bronchus and pulmonary artery. A piston pump connected to a reservoir beneath a flexible silicone reconstruction of a diaphragm simulated respiratory motion by rhythmic inflation and deflation of 1.5 L water. As biopsy device an 18-gauge prototype biopsy canula with a lancet-like, helically bended cutting edge was used. The artificial lesions were punctured under CT fluoroscopy-guidance (SOMATOM Sensation 64, Siemens, Erlangen, Germany; 30mAs/120 kV/5 mm slice thickness) implementing a dedicated protocol for CT fluoroscopy-guided lung biopsy. The mean-diameter of the artificial lesions was 8.3 {+-} 2.6 mm, and the mean-distance of the phantom wall to the lesions was 54.1 {+-} 13.5 mm. The mean-displacement of the lesions by respiratory motion was 14.1 {+-} 4.0 mm. The mean-duration of CT fluoroscopy was 9.6 {+-} 5.1 s. On a 4-point scale (1 = central; 2 = peripheral; 3 = marginal; 4 = off target), the mean-targeted precision was 1.9 {+-} 0.9. No misplacement of the biopsy canula affecting adjacent structures could be detected. The novel steerable biopsy canula proved to be efficient in the ex-vivo set-up. The chest phantom enabling respiratory motion and the steerable biopsy canula offer a feasible ex-vivo system for evaluating and training CT fluoroscopy-guided lung biopsy adapted to respiratory motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aortic Angiosarcoma: A Rare Cause for Leaking Thoracic Aneurysm

Primary malignant tumours of the aorta are rare. They present with aneurysm formation, arterial occlusion, and embolic phenomenon. We report the case of a 56-year-old man whose initial presentation and investigations lead to emergency endovascular stenting of a descending thoracic aneurysm with a contained leak. Initial response was favourable, yet the patient presented again with worsening symptoms. The circum-aortic haematoma expanded by 50% on subsequent imaging, but no endoleak was identified. When altered bone marrow signal was identified on magnetic resonance imaging, the possibility of malignancy was considered. A metastatic skin lesion was then biopsied, which demonstrated morphological and immunohistochemical features consistent with metastases from a pleomorphic sarcoma of the aorta.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Value of Preoperative Superselective Embolization of the Isthmus in a Patient with Upper Urinary Tract Urothelial Carcinoma and Horseshoe Kidney

Standard treatment for upper urinary tract urothelial carcinoma (UUTUC) implies the radical removal of all urothelium-lined tissue, which requires nephroureterectomy with bladder cuff removal. We report on a patient with a rare coincidence of UUTUC and horseshoe kidney in whom a preoperative angiography helped to identify and subsequently embolize an abberant isthmic feeding artery, which was located in between both collecting systems. Ischemic discoloration of the isthmus area facilitated resection and no major blood loss occurred. Preoperative superselective embolization of the isthmus as the renal split area can be an effective tool to facilitate nephroureterectomy in the case of a horseshoe kidney.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Solutions to Ensure Safe Yttrium-90 Radioembolization in Patients With Initial Extrahepatic Deposition of {sup 99m}Technetium-Albumin Macroaggregates

Purpose: To evaluate the incidence of extrahepatic deposition of technetium-99m-labeled albumin macroaggregates ({sup 99m}Tc-MAA) after pretreatment angiography, before yttrium-90 radioembolizaton ({sup 90}Y-RE), and to report on technical solutions that can be used to ensure safe delivery of {sup 90}Y-microspheres in patients with initial extrahepatic deposition. Materials and Methods: A retrospective analysis of 26 patients with primary and secondary liver malignancies, who were scheduled for treatment with {sup 90}Y-RE in our institution in 2009, was performed. The angiograms and single-photon emission computed tomography images of all patients were reviewed by an interventional radiologist and a nuclear medicine physician, respectively, to identify and localize extrahepatic deposition of {sup 99m}Tc-MAA when present. Subsequently, the technical solutions were used to successfully perform {sup 90}Y-RE in these patients were evaluated and described. Results: Extrahepatic deposition of {sup 99m}Tc-MAA was observed in 8 of 26 patients (31%). In 7 of 8 patients, a second pretreatment angiography was performed to detect the cause of extrahepatic deposition. The technical solutions to enable safe {sup 90}Y microspheres delivery included more distal placement of the microcatheter in the proper/right hepatic artery in 4 of 7 (57%) patients; (super)selective catheterization of multiple segmental branches in 2 of 7 (29%); and additional coiling of a newly detected branch in the remaining patient (14%). This was confirmed by a second MAA procedure. {sup 90}Y-RE was eventually performed in 25 of 26 (96%) patients. No procedure-related complications (<30 days) were observed. Conclusion: Extrahepatic deposition of {sup 99m}Tc-MAA after pretreatment angiography did occur in 8 of 26 (31%) patients. The technical solutions as presented allowed safe {sup 90}Y-RE delivery in 25 of 26 (96%) patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acute Left Arm Ischemia Associated with Floating Thrombus in the Proximal Descending Aorta: Combined Endovascular and Surgical Therapy

Free floating thrombus in the proximal descending aorta is an uncommon and dangerous condition that can be associated with acute peripheral embolization. The few cases described were solved with surgical and/or medical therapy. We report the case of a patient with acute left arm ischemia secondary to the presence of floating thrombus in the proximal descending aorta extending into the left subclavian artery, solved with combined endovascular and surgical therapy. Treatment was successfully performed with thrombembolectomy combined with temporary deployment, into the descending aorta, of a Wallstent in a 'basket-fashion' to avoid distal embolization secondary to thrombus fragmentation. At 1 year follow-up the patient remained symptom-free.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-Guided Thrombin Injection to Control Rapid Expansion of Ascending Aortic False Aneurysm 15 Months After Bentall-Bono Operation

We report a case of 57-year-old man treated emergently with CT-guided local thrombin injection as the first, life-saving step for control rapid expansion of the aortic pseudoaneurysm. Fifteen months earlier, he was operated on for ascending aortic true aneurysm and coronary artery disease. Upon admission, he had an anterior thoracic wall pulsatile tumor. Due to critical status, definite surgery was postponed and thrombin was injected close to the origin of pseudoaneurysm. It controlled successfully, bleeding from the ascending aorta and enabled the patient to survive the acute phase.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraoperative Sac Pressure Measurement During Endovascular Abdominal Aortic Aneurysm Repair

PurposeIntraoperative sac pressure was measured during endovascular abdominal aortic aneurysm repair (EVAR) to evaluate the clinical significance of sac pressure measurement.MethodsA microcatheter was placed in an aneurysm sac from the contralateral femoral artery, and sac pressure was measured during EVAR procedures in 47 patients. Aortic blood pressure was measured as a control by a catheter from the left brachial artery.ResultsThe systolic sac pressure index (SPI) was 0.87 {+-} 0.10 after main-body deployment, 0.63 {+-} 0.12 after leg deployment (P < 0.01), and 0.56 {+-} 0.12 after completion of the procedure (P < 0.01). Pulse pressure was 55 {+-} 21 mmHg, 23 {+-} 15 mmHg (P < 0.01), and 16 {+-} 12 mmHg (P < 0.01), respectively. SPI showed no significant differences between the Zenith and Excluder stent grafts (0.56 {+-} 0.13 vs. 0.54 {+-} 0.10, NS). Type I endoleak was found in seven patients (15%), and the SPI decreased from 0.62 {+-} 0.10 to 0.55 {+-} 0.10 (P = 0.10) after fixing procedures. Type II endoleak was found in 12 patients (26%) by completion angiography. The SPI showed no difference between type II endoleak positive and negative (0.58 {+-} 0.12 vs. 0.55 {+-} 0.12, NS). There were no significant differences between the final SPI of abdominal aortic aneurysms in which the diameter decreased in the follow-up and that of abdominal aortic aneurysms in which the diameter did not change (0.53 {+-} 0.12 vs. 0.57 {+-} 0.12, NS).ConclusionsSac pressure measurement was useful for instant hemodynamic evaluation of the EVAR procedure, especially in type I endoleaks. However, on the basis of this small study, the SPI cannot be used to reliably predict sac growth or regression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of Corona Enhancement of Hypervascular Hepatocellular Carcinoma by C-Arm Dual-Phase Cone-Beam CT During Hepatic Arteriography

The purpose of this study was to evaluate the detectability of corona enhancement around the hypervascular hepatocellular carcinoma (HCC) by dual-phase cone-beam computed tomography during hepatic arteriography (CBCTHA). Dual-phase CBCTHA was performed for 71 HCC lesions (mean {+-} SD 1.7 {+-} 0.9 cm), including seven presenting a nodule-in-nodule appearance and nine hypervascular pseudolesions. The first scan was performed during injection of 30-40 ml half-diluted contrast material at a rate of 1.5-2 ml/s through the hepatic artery. Scanning was initiated 7 s after the beginning of contrast material injection. The second scan was started 30 s after the end of the first scan. Detectability of corona enhancement on second-phase CBCTHA was evaluated. Thickness of corona enhancement was also analyzed as thin ({<=}2 mm) or thick (>2 mm). Corona enhancement was detected in 63 (88.7%) of 71 tumors (1.8 {+-} 0.9 cm), but it was not detected in eight tumors (1.0 {+-} 0.2 cm). Thin corona enhancement was seen in 18 tumors (1.2 {+-} 0.5 cm), and thick corona enhancement was seen in 45 tumors (2.0 {+-} 0.9 cm). There was a significant difference in tumor diameter between tumors with and those without corona enhancement (P = 0.0157) and between thin and thick corona enhancement (P = 0.001). In all seven early-stage tumors, corona enhancement was demonstrated around the hypervascular focus within the hypovascular tumor portion. None of the nine pseudolesions showed any corona enhancement. Dual-phase CBCTHA depicted corona enhancement in 88.7% of hypervascular HCC lesions. This technique may improve the diagnostic accuracy of HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computed Analysis of Three-Dimensional Cone-Beam Computed Tomography Angiography for Determination of Tumor-Feeding Vessels During Chemoembolization of Liver Tumor: A Pilot Study

The purpose of this study was to evaluate computed analysis of three-dimensional (3D) cone-beam computed tomography angiography (CTA) of the liver for determination of subsegmental tumor-feeding vessels (FVs). Eighteen consecutive patients underwent transarterial chemoembolization (TACE) from January to October 2008 for 25 liver tumors (15 hepatocellular carcinomas [HCCs] and 10 neuroendocrine metastases). Anteroposterior projection angiogram (two-dimensional [2D]) and 3D cone-beam CTA images were acquired by injection of the common hepatic artery. Retrospectively, FVs were independently identified by three radiology technologists using a software package (S) that automatically determines FVs by analysis of 3D images. Subsequently, three interventional radiologists (IRs) independently identified FVs by reviewing the 2D images followed by examination of the 3D images. Finally, the 'ground truth' for the number and location of FVs was obtained by consensus among the IRs, who were allowed to use any imaging-including 2D, 3D, and all oblique or selective angiograms-for such determination. Sensitivities, durations, and degrees of agreement for review of 2D, 3D, and S results were evaluated. Sensitivity of 3D (73%) was higher than 2D (64%) images for identification of FVs (P = 0.036). The sensitivity of S (93%) was higher than 2D (P = 0.02) and 3D (P = 0.005) imaging. The duration for review of 3D imaging was longer than that for 2D imaging (187 vs. 94 s, P = 0.0001) or for S (135 s, P = 0.0001). The degree of agreement between the IRs using 2D and 3D imaging were 54% and 62%, respectively, whereas it was 82% between the three radiology technologists using S. These preliminary data show that computed determination of FVs is both accurate and sensitive.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergency Endovascular 'Bridge' Treatment for Iliac-Enteric Fistula

Aortic aneurysm has been reported to be the dominant cause of primary iliac-enteric fistula (IEF) in >70% of cases [1]; other less common causes of primary IEF include peptic ulcer, primary aortitis, pancreatic pseudocyst, or neoplastic erosion into an adjacent artery [2, 3]. We describe an unusual case of IEF managed with a staged approach using an endovascular stent-graft as a 'bridge' in the emergency setting to optimize the next elective definitive excision of the lesion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of the Anti-tumor Effects of Two Platinum Agents (Miriplatin and Fine-Powder Cisplatin)

Purpose: This study was designed to evaluate the anti-tumor effects of miriplatin-lipidol and fine-powder cisplatin-lipiodol suspensions. Methods: Assessment of the cytotoxicity of two drugs was performed: a soluble derivative of miriplatin (DPC) and fine-powder cisplatin. We randomly divided 15 rabbits with transplanted VX2 liver tumors into three equal groups. They were infused via the proper hepatic artery with a miriplatin-lipiodol suspension (ML), a fine-powder cisplatin-lipiodol suspension (CL), or saline (control) and the tumor growth rate was determined on MR images acquired before and 7 days after treatment. The concentration of platinum (PCs) in blood was assayed immediately, and 10, 30, and 60 min, and 24 h and 7 days after drug administration. Its concentration in tumor and surrounding normal liver tissues was determined at 7 days postadministration. Results: At high concentrations, fine-powder cisplatin exhibited stronger cytotoxicity than DPC. At low concentrations, both agents manifested weak cytotoxicity. While there was no difference between the tumor growth rate of the ML and the CL groups, the difference between the controls and ML- and CL-treated rabbits was significant. The blood PCs peaked at 10 min and then gradually decreased over time. On the other hand, no platinum was detected at any point after the administration of ML. There was no difference between the ML and CL groups in the PCs in tumor tissues; however, in normal hepatic tissue, the PCs were higher in ML- than CL-treated rabbits. Conclusions: We confirmed the anti-tumor effect of ML and CL. There was no significant difference between the anti-tumor effect of ML and CL at 7 days postadministration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interlocking Detachable Coil Embolization by Technique of Dumbbell-Shaped Framing and Filling and Bridge Formation Under Balloon Dilatation for Huge Conglomerate Pulmonary Arteriovenous Malformation

A 60-year-old woman presented with a conglomerate pulmonary arteriovenous malformation (PAVM) size 8.2 Multiplication-Sign 7.2 cm on chest X-ray. Feeding arteries were A{sub a}{sup 7} and A{sub b}{sup 7}, A{sup 8}, and A{sup 10}. The diameter and length of the A{sub b}{sup 7} neck were 15.5 and 16 mm, respectively. After percutaneous transcatheter embolization of A{sup 8} and A{sup 10}, PTE of A{sub a}{sup 7} and A{sub b}{sup 7} was conducted under balloon occlusion with interlocking detachable coils using a technique of dumbbell-shaped framing and filling, making a bridge from A{sub b}{sup 7} to the trunk of A{sup 9} and A{sup 10}across A{sup 7}. Follow-up computed tomography 10 months after treatment showed marked shrinkage of the PAVM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effectiveness of Repeat Angiographic Assessment in Patients Designated for Radioembolization Using Yttrium-90 Microspheres With Initial Extrahepatic Accumulation of Technitium-99m Macroaggregated Albumin: A Single Center's Experience

Purpose: To evaluate the efficacy of a workflow consisting of repeat assessment in patients planned for yttrium-90 ({sup 90}Y) radioembolization in case of nontarget visceral technetium-99m ({sup 99m}Tc)-macroaggregated albumin (MAA) accumulation despite initial prophylactic coil embolization of nonhepatic arteries. Materials and Methods: In 341 patients with primary and secondary liver cancer, pretreatment hepatic angiograms, as well as single-photon emission computed tomography coregistered with magnetic resonance imaging scans, were obtained. Extrahepatic tracer deposition was identified in 33 patients (9.7%) necessitating repeat assessment. Images were reviewed to correlate the site of MAA accumulation with causative gastrointestinal vessels, and repeat angiograms served as reference standard. Results: At repeat angiography, the source of extrahepatic flow was identified and eliminated in 31 of 33 patients (93.9%). In 20 patients (60.6%), successful embolization of nontarget vessels was achieved, in 13 patients (39.4%), MAA was administered more distally. Afterward, extrahepatic MAA deposition was eliminated in 30 patients (90.9%). Conclusion: The algorithm of repeat assessment in case of extrahepatic MAA accumulation has proven highly effective to eliminate extrahepatic shunting, thus decreasing the risk of postradioembolization complications due to inadvertent visceral microsphere deposition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transsinusoidal Portal Vein Embolization with Ethylene Vinyl Alcohol Copolymer (Onyx): A Feasibility Study in Pigs

Purpose: Portal vein embolization is performed to increase the future liver remnant before liver surgery in patients with liver malignancies. This study assesses the feasibility of a transsinusoidal approach for portal vein embolization (PVE) with the ethylene vinyl alcohol copolymer, Onyx. Methods: Indirect portography through contrast injection in the cranial mesenteric artery was performed in eight healthy pigs. Onyx was slowly injected through a microcatheter from a wedged position in the hepatic vein and advanced through the liver lobules into the portal system. The progression of Onyx was followed under fluoroscopy, and the extent of embolization was monitored by indirect portography. The pigs were euthanized immediately (n = 2), at 7 days (n = 4), or at 21 days postprocedure (n = 2). All pigs underwent necropsy and the ex vivo livers were grossly and histopathologically analyzed. Results: Transsinusoidal PVE was successfully performed in five of eight pigs (63%). In 14 of 21 injections (67%), a segmental portal vein could be filled completely. A mean of 1.6 liver lobes per pig was embolized (range 1-2 lobes). There were no periprocedural adverse events. Focal capsular scarring was visible on the surface of two resected livers, yet the capsules remained intact. Histopathological examination showed no signs of recanalization or abscess formation. Mild inflammatory reaction to Onyx was observed in the perivascular parenchyma. Conclusions: The porcine portal vein can be embolized through injection of Onyx from a wedged position in the hepatic vein. Possible complications of transsinusoidal PVE and the effect on contralateral hypertrophy need further study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Unusual Case of Stent Migration After Celiac Trunk Endovascular Revascularization

A 61-year-old woman underwent celiac trunk stenting to treat abdominal angina. Three months later, she was readmitted for recurrent symptoms. Computed tomography control revealed the migration of the stent into the splenic artery. No sign of vessel injury or end-organ ischemia was detected. Repeat stenting of the celiac trunk was performed; the postoperative course was uneventful. 12 months later, the patient was asymptomatic with the second stent in its correct position, and she was asymptomatic for mesenteric ischemia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Targeted Vessel Ablation for More Efficient Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids

Purpose: To report the first clinical experience with targeted vessel ablation during magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) treatment of symptomatic uterine fibroids. Methods: Pretreatment T1-weighted contrast-enhanced magnetic resonance angiography was used to create a detailed map of the uterine arteries and feeding branches to the fibroids. A three-dimensional overlay of the magnetic resonance angiography images was registered on 3D T2-weighted pretreatment imaging data. Treatment was focused primarily on locations where supplying vessels entered the fibroid. Patients were followed 6 months after treatment with a questionnaire to assess symptoms and quality of life (Uterine Fibroid Symptom and Quality of Life) and magnetic resonance imaging to quantify shrinkage of fibroid volumes. Results: In two patients, three fibroids were treated with targeted vessel ablation during MR-HIFU. The treatments resulted in almost total fibroid devascularization with nonperfused volume to total fibroid volume ratios of 84, 68, and 86%, respectively, of treated fibroids. The predicted ablated volumes during MR-HIFU in patients 1 and 2 were 45, 40, and 82 ml, respectively, while the nonperfused volumes determined immediately after treatment were 195, 92, and 190 ml respectively, which is 4.3 (patient 1) and 2.3 (patient 2) times higher than expected based on the thermal dose distribution. Fibroid-related symptoms reduced after treatment, and quality of life improved. Fibroid volume reduction ranged 31-59% at 6 months after treatment. Conclusion: Targeted vessel ablation during MR-HIFU allowed nearly complete fibroid ablation in both patients. This technique may enhance the use of MR-HIFU for fibroid treatment in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗