Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ADHESIVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Quantifying Shear-Induced Deformation and Detachment of Individual Adherent Sickle Red Blood Cells

According to the article, vaso-occlusive crisis, a common painful complication of sickle cell disease, is a complex process triggered by intercellular adhesive interactions among blood cells and the endothelium in all human organs (e.g., the oxygen-rich lung as well as hypoxic systems such as liver and kidneys). We present a combined experimental-computational study to quantify the adhesive characteristics of sickle mature erythrocytes (SMEs) and irreversibly sickled cells (ISCs) under flow conditions mimicking those in postcapillary venules. We employed an in vitro microfluidic cell adherence assay, which is coated uniformly with fibronectin. We investigated the adhesion dynamics of SMEs and ISCs in pulsatile flow under well-controlled hypoxic conditions, inferring the cell adhesion strength by increasing the flow rate (or wall shear stress (WSS)) until the onset of cell detachment. In parallel, we performed simulations of individual SMEs and ISCs under shear. We introduced two metrics to quantify the adhesion process, the cell aspect ratio (AR) as a function of WSS and its rate of change (the dynamic deformability index). We found that the AR of SMEs decreases significantly with the increase of WSS, consistent between the experiments and simulations. In contrast, the AR of ISCs remains constant in time and independent of the flow rate. The critical WSS value for detaching a single SME in oxygenated state is in the range of 3.9–5.5 Pa depending on the number of adhesion sites; the critical WSS value for ISCs is lower than that of SMEs. Our simulations show that the critical WSS value for SMEs in deoxygenated state is above 6.2 Pa (multiple adhesion sites), which is greater than their oxygenated counterparts. We investigated the effect of cell shear modulus on the detachment process; we found that for the same cell adhesion spring constant, the higher shear modulus leads to an earlier cell detachment from the functionalized surface. These findings may aid in the understanding of individual roles of sickle cell types in sickle cell disease vaso-occlusion.

Biophysics↗

Investigation of low cost, high reliability sealing techniques for hybrid microcircuits, phase 1

A preliminary investigation was made to determine the feasibility of using adhesive package sealing for hybrid microcircuits. Major effort consisted of: (1) surveying representative hybrid manufacturers to assess the current use of adhesives for package sealing; (2) making a cost comparison of metallurgical versus adhesive package sealing; (3) determining the seal integrity of gold plated flatpack type packages sealed with selected adhesives, thermal shock, temperature cycling, mechanical shock, and constant acceleration test environments; and (4) defining a more comprehensive study to continue the evaluation of adhesives for package sealing. Results showed that 1.27 cm square gold plated flatpack type packages sealed with the film adhesives and the paste adhesive retained their seal integrity after all tests, and that similarly prepared 2.54 cm square packages retained their seal integrity after all tests except the 10,000 g's constant acceleration test. It is concluded that these results are encouraging, but by no means sufficient to establish the suitability of adhesives for sealing high reliability hybrid microcircuits.

Perkins, K. L.↗

Silver-Teflon coating improvement

Approximately forty adhesives were subjected to laboratory screening. Seven candidate adhesives were selected from the screening tests and evaluated in a thermal vacuum test on radiator panels similar to the anticipated flight hardware configuration. Several classes of adhesives based on epoxide, polyester, silicone, and urethane resin systems were tested. These included contact adhesives, heat cured adhesives, heat and pressure cured adhesives, pressure sensitive adhesives, and two part paint-on or spray-on adhesives. The panels were tested in a space environmental simulation laboratory chamber during the July 9-20, 1973 time span.

Reed, M. W.↗

Surface Modification of Backsheets Using Coupling Agents for Roll-To-Roll Processed Thin-Film Solar Photovoltaic (PV) Module Packaging Application

For many flexible electronic and photonic devices, moisture stability is one of the most important factors that affects its short- and long-term performance. To maintain the performance, the device should be packaged in such a way that it hermetically blocks moisture from the device; however, in practice, it is rather difficult to achieve. The more practical solution is to impede the moisture ingress to the device. In optoelectronic devices that will be outdoors like solar cells, the interfacial adhesion strength between the encapsulant layer (adhesive) and a moisture barrier layer is also a critical parameter. This paper presents surface modifications of poly(ethylene terephthalate) (PET) carrier films, one of the layers in the trilayer barrier film that directly adheres to an encapsulant, using chemical, UV/ozone, and both treatments to improve adhesion with the thermoset encapsulant polymer material. Whereas previous studies also utilized treatment methods to increase the wettability characteristics, in this paper, we not only present the results of the adhesion strength upon various techniques to achieve good adhesion but also screen their behavior upon exposure to a damp–heat (60 °C, 90% RH) environment. Here, we found that the combined treatment method increases the adhesion by up to 12.1-fold and demonstrates up to a 200% increase in adhesion strength even upon our severe damp–heat environmental condition.

36 MATERIALS SCIENCE↗

Cell-matrix interactions of Entamoeba histolytica and E. dispar. A comparative study by electron-, atomic force- and confocal microscopy

Invasion of tissues by Entamoeba histolytica is a multistep process that initiates with the adhesion of the parasite to target tissues. The recognition of the non-invasive Entamoeba dispar as a distinct, but closely related protozoan species raised the question as to whether the lack of its pathogenic potential could be related to a weaker adhesion due to limited cytoskeleton restructuring capacity. We here compared the adhesion process of both amebas to fibronectin through scanning, transmission, atomic force, and confocal microscopy. In addition, electrophoretic and western blot assays of actin were also compared. Adhesion of E. histolytica to fibronectin involves a dramatic reorganization of the actin network that results in a tighter contact to and the subsequent focal degradation of the fibronectin matrix. In contrast, E. dispar showed no regions of focal adhesion, the cytoskeleton was poorly reorganized and there was little fibronectin degradation. In addition, atomic force microscopy using topographic, error signal and phase modes revealed clear-cut differences at the site of contact of both amebas with the substrate. In spite of the morphological and genetic similarities between E. histolytica and E. dispar the present results demonstrate striking differences in their respective cell-to-matrix adhesion processes, which may be of relevance for understanding the invasive character of E. histolytica. - Highlights: • Striking differences in adhesion to FN between E. histolytica and E. dispar. • A greater degree of cell stiffness in E. histolytica with respect to E. dispar. • E. histolytica but not E. dispar forms regions of close contact with FN. • The actin cytoskeleton is involved in the pathogenicity of E. histolytica.

60 APPLIED LIFE SCIENCES↗

Structural basis of typhoid: Salmonella typhi type IVb pilin (PiLS) and cystic fibrosis transmembrane conductance regulator interaction

The type IVb pilus of the enteropathogenic bacteria Salmonella typhi is a major adhesion factor during the entry of this pathogen into gastrointestinal epithelial cells. Its target of adhesion is a stretch of 10 residues from the first extracellular domain of cystic fibrosis transmembrane conductance regulator (CFTR). The crystal structure of the N-terminal 25 amino acid deleted S. typhi native PilS protein ({Delta}PilS), which makes the pilus, was determined at 1.9 {angstrom} resolution by the multiwavelength anomalous dispersion method. Also, the structure of the complex of {Delta}PilS and a target CFTR peptide, determined at 1.8 {angstrom}, confirms that residues 113-117 (NKEER) of CFTR are involved in binding with the pilin protein and gives us insight on the amino acids that are essential for binding. Furthermore, we have also explored the role of a conserved disulfide bridge in pilus formation. The subunit structure and assembly architecture are crucial for understanding pilus functions and designing suitable therapeutics against typhoid.

59 BASIC BIOLOGICAL SCIENCES↗

Biofouling and Corrosion Study for a Novel Linear Guided Wave Energy Converter (Post Access Report)

The overall objective of this project was to examine the reliability and performance of antibiofouling coatings used for a wave energy converter (WEC) developed by E-Wave Technologies. The particular coatings were selected for their low toxicity and potential compatibility with aquaculture. The aim of this work was to 1) test coating solutions to prevent biofouling growth and saltwater corrosion on the static (paddle and attachment frame surface) components of the WEC that are submerged, 2) determine adhesion of the coatings to system components, and 3) assess the ease and effectiveness of biofouling cleaning to insure long term performance of the system. An analysis of commercial coatings was performed using methods to examine the prevention of biofouling and coating adhesion properties on two key materials of the WEC, which were 316L low carbon marine grade stainless steel (SS) and Ultra High Molecular Weight Polyethylene (PE). Three marine antifouling paints were selected based on their unique properties to test how different paint styles perform on different materials. The selected paints were ePaint Ecominder self-polishing paint with Zinc Omadine for slime control, Pettit ECO HRT Copper-Free ablative antifouling with Econea biocide, and Intersleek 1100SR foul release. Pacific Northwest National Laboratory (PNNL) prepared PE and SS substrates coated with the three paints and compared the performance against uncoated substrates when submerged in raw seawater for 3-, 6-, and 9-month (m) time periods. Results in adhesion testing indicated that Pettit and ePaint materials clearly bonded strongly to SS, but did not bond comparably well to PE. It was noted during adhesion testing that the Intersleek surfaces were especially difficult to test as the paint highly resists bonding to the epoxy adhesives used with the adherence testing platform. The wear rate of the coatings was not measured under this study; however, based on adhesion testing, coatings in the sliding regions of the Ewave device are expected to wear rapidly. Sandia National Laboratories (SNL) evaluated the adhesion of three different paints to PE and SS substrates which were exposed to a marine environment for time intervals of 0, 3, 6, and 9 months. From qualitative visual analysis of the 3 in2 coupons when pulled from the tank, the 3 in2 coupons generally only appeared to have biofouling consisting of filamentous algae or diatoms, which all have relatively low mass and can be easily wiped from the surface of coupons. Qualitative visual analysis indicated that ECO HRT and Unpainted were consistently worse than Intersleek and Ecominder at all time points. Results provide insight to aid with down-selection of commercial coatings under static conditions to support reliability of the WEC and potential maintenance schedules. This investigation was conducted using small coupon samples suspended in seawater and the development of testing rigs for dynamic component level testing is needed for future work. In addition, the potential toxicity of these commercial coatings on aquaculture has not been determined by this study. One recommendation is to conduct toxicity investigations at the Environmental Toxicity Laboratory at Oak Ridge National Laboratory.

16 TIDAL AND WAVE POWER↗

Nondestructive Determination of Bond Strength

Although many nondestructive techniques have been applied to detect disbonds in adhesive joints, no absolutely reliable nondestructive method has been developed to detect poor adhesion and evaluate the strength of bonded joints prior to the present work which used nonlinear ultrasonic methods to investigate adhesive bond cure conditions. Previously, a variety of linear and nonlinear ultrasonic methods with water coupling had been used to study aluminum-adhesive-aluminum laminates, prepared under different adhesive curing conditions, for possible bond strength determination. Therefore, in the course of this research effort, a variety of finite-amplitude experimental methods which could possibly differentiate various cure conditions were investigated, including normal and oblique incidence approaches based on nonlinear harmonic generation as well as several non-collinear two-wave interaction approaches. Test samples were mechanically scanned in various ways with respect to the focus of a transmitting transducer operated at several variable excitation frequencies and excitation levels. Even when powerful sample-related resonances were exploited by means of a frequency scanning approach, it was very difficult to isolate the nonlinear characteristics of adhesive bonds. However, a multi-frequency multi-power approach was quite successful and reliable. Ultrasonic tone burst signals at increasing power levels, over a wide frequency range, were transmitted through each bond specimen to determine its excitation dependent nonlinear harmonic resonance behavior. Relative amplitude changes were observed particularly in the higher harmonic spectral data and analyzed using a local displacement and strain analysis in the linear approximation. Two analysis approaches of the excitation-dependent data at specific resonances were found to be quite promising. One of these approaches may represent a very robust algorithm for classifying an adhesive bond as being properly cured or not. Another approach, in addition to differentiation between various cure conditions, may even provide information with respect to the bond strength. Several technical papers were published during the course of this research and a summary is presented in the Ph.D. dissertation of Tobias P. Berndt, a graduate student financially supported by this NASA Grant.

Source record↗

Evaluation of a Multi-Axial, Temperature, and Time Dependent (MATT) Failure Model

To obtain a better understanding the response of the structural adhesives used in the Space Shuttle's Reusable Solid Rocket Motor (RSRM) nozzle, an extensive effort has been conducted to characterize in detail the failure properties of these adhesives. This effort involved the development of a failure model that includes the effects of multi-axial loading, temperature, and time. An understanding of the effects of these parameters on the failure of the adhesive is crucial to the understanding and prediction of the safety of the RSRM nozzle. This paper documents the use of this newly developed multi-axial, temperature, and time (MATT) dependent failure model for modeling failure for the adhesives TIGA 321, EA913NA, and EA946. The development of the mathematical failure model using constant load rate normal and shear test data is presented. Verification of the accuracy of the failure model is shown through comparisons between predictions and measured creep and multi-axial failure data. The verification indicates that the failure model performs well for a wide range of conditions (loading, temperature, and time) for the three adhesives. The failure criterion is shown to be accurate through the glass transition for the adhesive EA946. Though this failure model has been developed and evaluated with adhesives, the concepts are applicable for other isotropic materials.

Richardson, D. E.↗

Hypergravity Stimulates the Extracellular Matrix/Integrin-Signaling Axis and Proliferation in Primary Osteoblasts

We set out to determine the molecular mechanisms involved in the proliferative response of primary rat osteoblasts to mechanical stimulation using cell culture centrifugation as a model for hypergravity. We hypothesized that this proliferative response is mediated by specific integrin/Extracellular Matrix (ECM) interactions. To investigate this question we developed a cell culture centrifuge and an automated system that performs cell fixation during hypergravity loading. We generated expression vectors for various focal adhesion and cytoskeletal proteins fused to GFP or dsRed and visualized these structures in transfected (or infected) osteoblasts. The actin cytoskeleton was also visualized using rhodamine-phalloidin staining and Focal Adhesion Kinase (FAK) levels were assessed biochemically. We observed that a 24 hour exposure to 50-g stimulated proliferation compared to the 1-g control when cells were plated on fibronectin, collagen Type I , and collagen Type IV, but not on uncoated tissue culture plastic surfaces. This proliferative response was greatest for osteoblasts grown on fibronectin (2-fold increase over 1-g control) and collagen Type I (1.4 fold increase over 1-g control), suggesting that specific matrices and integrins are involved in the signaling pathways required for proliferation. Exposing osteoblasts grown on different matrices to 10-g or 25-g showed that effects on proliferation depended on both matrix type and loading level. We found that osteoblasts exposed to a short pulse of hypergravity during adhesion spread further and had more GFP-FAK containing focal adhesions compared to their 1-g controls. While overall levels of FAK did not change, more FAK was in the active (phosphorylated) form under hypergravity than in the 1-g controls. Cytoskeletal F-actin organization into filaments was also more prominent after brief exposures to hypergravity during the first five minutes of adhesion. These results suggest that specific integrins sense hypergravity and activate distinct matrix-dependent FAK signaling pathways that can enhance proliferation. Our results also imply that brief exposures to hypergravity accelerate cell adhesion and spreading processes via the focal adhesion-signaling axis. These results support the role of the ECM/integrin-signaling axis in osteoblast response to hypergravity loading.

Parra, M.↗

Shape Bonding method

The present invention is directed to a method of bonding at least two surfaces together. The methods step of the present invention include applying a strip of adhesive to a first surface along a predefined outer boundary of a bond area and thereby defining a remaining open area there within. A second surface, or gusset plate, is affixed onto the adhesive before the adhesive cures. The strip of adhesive is allowed to cure and then a second amount of adhesive is applied to cover the remaining open area and substantially fill a void between said first and second surfaces about said bond area. A stencil may be used to precisely apply the strip of adhesive. When the strip cures, it acts as a dam to prevent overflow of the subsequent application of adhesive to undesired areas. The method results in a precise bond area free of undesired shapes and of a preferred profile which eliminate the drawbacks of the prior art bonds.

Pontius, James T.↗

Vertically oriented ZrO 2 –TiO 2 –Nb 2 O 5 –Al 2 O 3 mixed nanopatterned bioceramics on Ti6Al7Nb implant assessed by laser spallation technique

Recently, reports on the fabrication of nonstructural configuration have generated scientific interest due to increased awareness of the oxide nanotubes in the biomedical implant field and other industrial approaches. In this paper, highly ordered ZrO 2 –TiO 2 –Nb 2 O 5 –Al 2 O 3 nanotube arrays were grown by physical vapor deposition (PVD) of a zirconium layer on titanium-niobium alloy implant (IMPTi67) and succeeding anodic oxidation at a constant voltage (60 V) with exposure times ranging from 30 to 300 min. To crystallize the resulting mixed oxide nanotubes, heat treatment was also applied. The nanotubes were placed in an atmospheric furnace at temperatures ranging from 450 to 800 °C for 2 h. This treatment provided a morphological evolution was strongly influenced by the anodization time, where highly aligned bamboo-shaped oxide nanotubes (161 ± 44 nm in inside diameter and ~1 μm in length) were formed after 300 min of anodization. After annealing at temperature below 500 °C, the nano-array configuration remained stable and the average inner diameter decreased to around 40 nm. The effects of anodically fabrication time on the adhesion strength of four-phase multilayered mixed oxide nanotubes on anodized Zr/IMPTi67 surfaces assed by microscratch analysis. From the results, increasing the annealing temperature further to 800 °C fully destroyed the nanotubes and consequently the tubular arrangement was converted to a coarse grain structure. It was revealed that annealing at 450 °C for 2 h was the optimum conditions for stable nanotubular array generation, where the highest adhesion strength (shifted from 2595.59 to 2640.12 mN), microhardness (372 HV) and hydrophilicity (15 ± 1°) were recorded. It is notify that the adhesion strength of highly ordered mixed nanotubes was remarkably decreased after thermal treatment at 800 °C (1817.51 mN). Through the laser spallation analysis, the intrinsic adhesion strength of the Zr/IMPTi67 interface was found to be at 63 MPa, while the first stages of failure occurred at a stress state of 35 MPa. The adhesion of the film with the tubular structure proved to have a significantly larger adhesion strength of 246 MPa for the complete failure and 203 MPa for incipient stages of spallation. Finally, the considered surface modification can be an effective step in determining the interface strength between biomedical implants and the nanostructured coatings.

36 MATERIALS SCIENCE↗

Identification of inhibitors of α2β1 integrin, members of C-lectin type proteins, in Echis sochureki venom

Snake venom antagonists of α2β1 integrin have been identified as members of a C-lectin type family of proteins (CLP). In the present study, we characterized three new CLPs isolated from Echis sochureki venom, which interact with this integrin. These proteins were purified using a combination of gel filtration, ion exchange chromatography and reverse phase HPLC. Sochicetin-A and sochicetin-B potently inhibited adhesion of cells expressing α2β1 integrin and binding of isolated α2β1 ectodomain to collagen I, as well as bound to recombinant GST-α2A domain in ELISA, whereas activity of sochicetin-C in these assays was approximately two orders of magnitude lower. Structurally, sochicetin-B and sochicetin-C are typical heterodimeric αβ CLPs, whereas sochicetin-A exhibits a trimer of its subunits (αβ){sub 3} in the quaternary structure. Immobilized sochicetins supported adhesion of glioma cell lines, LN18 and LBC3, whereas in a soluble form they partially inhibited adhesion of these cells to collagen I. Glioma cells spread very poorly on sochicetin-A, showing no cytoskeleton rearrangement typical for adhesion to collagen I or fibronectin. Adhesion on CLP does not involve focal adhesion elements, such as vinculin. Sochicetin-A also inhibited collagen-induced platelet aggregation, similar to other CLPs' action on the blood coagulation system. - Highlights: • Isolation of three novel snake venom CLPs inhibiting α2β1 integrin • Reporting hexameric CLP, sochicetin-A with anti-collagen receptor activity • CLPs antagonize the interaction of glioma cells with collagen matrix. • Sochicetin-A does not support glioma cell spreading.

60 APPLIED LIFE SCIENCES↗

Evidence that gecko setae are coated with an ordered nanometre-thin lipid film

The fascinating adhesion of gecko to virtually any material has been related to surface interactions of myriads of spatula at the tips of gecko feet. Surprisingly, the molecular details of the surface chemistry of gecko adhesion are still largely unknown. Lipids have been identified within gecko adhesive pads. However, the location of the lipids, the extent to which spatula are coated with lipids, and how the lipids are structured are still open questions. Lipids can modulate adhesion properties and surface hydrophobicity and may play an important role in adhesion. We have therefore studied the molecular structure of lipids at spatula surfaces using near-edge X-ray absorption fine structure imaging. We provide evidence that a nanometre-thin layer of lipids is present at the spatula surfaces of the tokay gecko (Gekko gecko) and that the lipids form ordered, densely packed layers. Such dense, thin lipid layers can effectively protect the spatula proteins from dehydration by forming a barrier against water evaporation. Lipids can also render surfaces hydrophobic and thereby support the gecko adhesive system by enhancement of hydrophobic–hydrophobic interactions with surfaces.

59 BASIC BIOLOGICAL SCIENCES↗

Process Development of the Vaporizing Foil Actuator Welding Technique

The industrial focus on continuous improvement for products is leading design engineers to consider multi-material design concepts more frequently. The design concepts use the advantages of each material while simultaneously minimizing the drawbacks. It also allows for the overall weight of the products to be reduced. Some traditional joining methods, though, struggle to join dissimilar material combinations. A technique known as vaporizing foil actuator welding, which was developed around ten years ago, is a solid-state joining method that has the potential to overcome the barriers to dissimilar material joining. The biggest drawbacks of vaporizing foil actuator welding are that it is still exclusively used in laboratory settings and early in the technology development process. As such, there is not enough confidence in the process for it to be transitioned to manufacturing environments yet. This work begins by analyzing the current state of the technology and identifying a roadmap to achieve a transition to manufacturing. The analysis found that increased confidence in the technology requires sample to sample repeatability to be improved. Beyond that, the process also needs to be fully automated before it can be considered as a viable technique for mass production. In order to further develop the technique, a fully automated work cell was constructed. By removing the human element from the process, this cell helped identify iii the aspects which contribute to process variability. The positioning of the vaporizing foil actuator was identified as the most important factor in process stability. A small set of samples were made in the automated cell with the addition of one component epoxy adhesive around the perimeter of the weld. These samples showed improved process repeatability compared with the samples made without adhesive. This indicates that small amounts of adhesive may be critical in using the process in industrial settings. Additionally, work was performed with manual positioning and adhesive dispensing. This work found that a hybrid joint behaves like traditional weld bonding, where the addition of adhesive makes the joint stronger than if either of the two joining methods were used on their own. To realize this performance with vaporizing foil actuator welding, though, the adhesive needs to be protected from burning during the rapid compression of air during the impact process.

36 MATERIALS SCIENCE↗

A family of cell-adhering peptides homologous to fibrinogen C-termini

Research highlights: {yields} Cell-adhesive sequences homologous to fibrinogen C-termini exist in other proteins. {yields} The extended homologous cell-adhesive C-termini peptides family is termed Haptides. {yields} In membrane-like environment random coiled Haptides adopt a helical conformation. {yields} Replacing positively charged residues with alanine reduces Haptides activity. -- Abstract: A family of cell-adhesive peptides homologous to sequences on different chains of fibrinogen was investigated. These homologous peptides, termed Haptides, include the peptides C{beta}, preC{gamma}, and C{alpha}E, corresponding to sequences on the C-termini of fibrinogen chains {beta}, {gamma}, and {alpha}E, respectively. Haptides do not affect cell survival and rate of proliferation of the normal cell types tested. The use of new sensitive assays of cell adhesion clearly demonstrated the ability of Haptides, bound to inert matrices, to mediate attachment of different matrix-dependent cell types including normal fibroblasts, endothelial, and smooth muscle cells. Here we present new active Haptides bearing homologous sequences derived from the C-termini of other proteins, such as angiopoietin 1 and 2, tenascins C and X, and microfibril-associated glycoprotein-4. The cell adhesion properties of all the Haptides were found to be associated mainly with their 11 N-terminal residues. Mutated preC{gamma} peptides revealed that positively charged residues account for their attachment effect. These results suggest a mechanism of direct electrostatic interaction of Haptides with the cell membrane. The extended Haptides family may be applied in modulating adhesion of cells to scaffolds for tissue regeneration and for enhancement of nanoparticulate transfection into cells.

60 APPLIED LIFE SCIENCES↗

Rational Design of a Multifunctional Binder for High-Capacity Silicon-Based Anodes

Although several principles have been recognized to fabricate a nominal "better" binder, there continues to be a lack of a rational design and synthesis approach that would meet the robust criteria required for silicon (Si) anodes. Herein, we report a synthetic polymer binder, i.e., catechol-functionalized chitosan cross-linked by glutaraldehyde (CS-CG+GA), that serves dual functionalities: (a) wetness-resistant adhesion capability via catechol grafting and (b) mechanical robustness via in situ formation of a three-dimensional (3D) network. A SiNP-based anode with a designed functional polymer network (CS-CG10%+6%GA) exhibits a capacity retention of 91.5% after 100 cycles (2144 +/- 14 mAh/g). Properties that are traditionally considered to be advantageous, including stronger adhesion strength and higher mechanical robustness, do not always improve the binder performance. A clear relationship between these properties and ultimate electrochemical performance is established by assessing the rheological behavior, mechanical property, adhesion force, peel stress, morphology evolution, and semiquantitative evaluation. This study provides a clear path for the rational design of high-performance functional polymer binders for not only Si-based electrodes but also other types of alloy and conversion-based electrodes.

Cao, Peng-Fei↗

SDU7 Interior Liner Testing & Evaluation

The Saltstone Disposal Unit 7 (SDU7) project requested the Savannah River National Laboratory (SRNL), Materials Science & Engineering (MS&E) organization to evaluate an alternative bromobutyl liner and adhesives for potential use in SDU7 based on applicable ASTM testing standards. SRNL performed similar testing for the liner system used in SDU6. Bonded and non-bonded samples of the alternative liner (Blair Rubber Marflex™ RCHB60HT) were subjected to specific ASTM tests after immersion in two Saltstone leachate simulants, designated S1 and S2, for 1000 hours at 60 °C. Immersion exposures were performed at the Savannah River Ecology Laboratory (SREL). Post-immersion testing involved mechanical property and hardness testing of base material, lap-shear testing of bonded samples and rubber-to-concrete paver interrogation. The liner exhibited an approximate 40% drop in tensile strength and 25% drop in elongation at failure from baseline values after immersion, though final values are comparable to previous SDU6 liner values and are within liner manufacturer property ranges. Overall lap-shear strength behavior of the four adhesives showed a similar pattern, with short-term reduction and subsequent increase in peak load values. However, ranking of adhesives varied with the metric used for comparison. Two of the four adhesives tested (Normac 900 and REMA SC 4000) showed overall better behavior, collectively considering immersion performance, lap-shear data and bonded paver interrogation. Lap-shear samples bonded with the REMA adhesive showed the best combination of final retained bond strength, 6-week average bond strength and bond failure mode. Only one paver (REMA SC4000) was noted to have no defects after immersion. This document details the testing performed and provides conclusions and recommendations. The testing suggests that SDU liner performance is highly dependent upon seam integrity, which collectively depends on a combination of adhesive properties, installation workmanship and inspection/quality control.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗