Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “waters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Effect of Initial Water Saturation on The Performance of Fracturing Fluids With and Without Polyallylamine under Simulated EGS Conditions

Objectives/Scope: StimuFrac (US Patents 9,873,828 B2 and 9,447,315 B2), a CO2-reactive polymer aqueous solution [polyallylamine (PAA) 1wt% in water] combined with CO2, can be used as a less water-intensive fracturing fluid for enhanced geothermal systems (EGS). Our previous results show that in hot dry rock (HDR), PAA/CO2 fracturing fluids outperformed other fluids such as water, CO2, and CO2/water in generating large fractures with less fluid consumed. The objective of this work is to study the effect of initial water saturation of rock on the performance of StimuFrac fluid in ½ foot cubic rock samples and under representative EGS pressure/temperature conditions using cyclic and constant flow rate injection strategies. The fracturing results are compared with results using different fracturing fluids in terms of controlling fracture propagation rates, fracture hydraulic conductivity, breakdown pressures and volumes of fluids required. Methods/Procedures/Process: In all tests, water was initially injected into the rock to increase the water saturation before the fracturing processes to simulate actual geothermal reservoir conditions. For the cyclic injection, one complete cycle consisted of (1) a PAA slug (or water slug) injection followed by (2) CO2 injection to initiate the fracture. In the second step of the first cycle, the pressure of CO2 is increased until a maximum pressure is reached (fracture is initiated at this moment), and then the injection of CO2 is allowed for another 30 seconds to propagate the fracture. Then, the two-step cycle of PAA followed by CO2 injection (up to 2-4 mL/min) was continued. For the constant flow rate injection strategies, the initial water saturation was increased by injecting water at 1000 psi and 200°C for three days. After that, an initial slug of water, CO2, or PAA was injected and then fracturing was initiated and propagated by injecting CO2 at a constant flow rate. Applications/Significance/Novelty: The results of this study suggest that water saturation, especially near the wellbore region, will significantly affect the fracturing fluid transmission into the rock porous media by changing the relative permeability of CO2 or water, thus affecting the fracture initiation and propagation. In this study, fracturing with cyclic injection or constant flow rate injection methods were performed using three different kinds of fluids systems. These fluids are water, CO2, or CO2 with PAA. Splitting the rock samples in half after fracturing reveals that the fracture propagation is significantly limited under these high water saturated conditions compared to dry initial conditions: The fractures propagate less than 1/3 length of the distance from the wellbore to rock surface, and in some cases no fracture is generated. This may be caused by the fact that leak-off is dominating the fracturing process and the injected fluid flow rate is not high enough to overcome the leak-off even under high flow rate injection conditions. Additionally, CO2 could be leaking off into the wellbore annulus and this may be making it more difficult to generate pressure gradients away from the near-wellbore region.

Jian, Guoqing↗

Subsecond Morphological Changes in Nafion during Water Uptake Detected by Small-Angle X-ray Scattering

The ability of the Nafion membrane to absorb water rapidly and create a network of hydrated interconnected water domains provides this material with an unmatched ability to conduct ions through a chemically and mechanically robust membrane. The morphology and composition of these hydrated membranes significantly affects their transport properties and performance. This research demonstrates that differences in interfacial interactions between the membranes exposed to vapor or liquid water can cause significant changes in kinetics of water uptake. In situ small-angle X-ray scattering (SAXS) experiments captured the rapid swelling of the membrane in liquid water with a nanostructure rearrangement on the order of seconds. For membranes in contact with water vapor, morphological changes are four orders-of-magnitude slower than in liquid water, suggesting that interfacial resistance limits the penetration of water into the membrane. Furthermore, upon water absorption from liquid water, a structural rearrangement from a distribution of spherical and cylindrical domains to exclusively cylindrical-like domains is suggested. These differences in water-uptake kinetics and morphology provide a new perspective into Schroeder's paradox, which dictates a different water content for vapor- and liquid-equilibrated ionomers at unit activity. Lastly, the findings of this work provide critical insights into the fast kinetics of water absorption of the Nafion membrane, which can aid in the design of energy conversion devices that operate under frequent changes in environmental conditions.

30 DIRECT ENERGY CONVERSION↗

Detecting forest response to droughts with global observations of vegetation water content

Droughts in a warming climate have become more common and more extreme, making understanding forest responses to water stress increasingly pressing. Analysis of water stress in trees has long focused on water potential in xylem and leaves, which influences stomatal closure and water flow through the soil-plant-atmosphere continuum. At the same time, changes of vegetation water content (VWC) are linked to a range of tree responses, including fluxes of water and carbon, mortality, flammability, and more. Unlike water potential, which requires demanding in situ measurements, VWC can be retrieved from remote sensing measurements, particularly at microwave frequencies using radar and radiometry. Here, we highlight key frontiers through which VWC has the potential to significantly increase our understanding of forest responses to water stress. To validate remote sensing observations of VWC at landscape scale and to better relate them to data assimilation model parameters, we introduce an ecosystem-scale analogue of the pressure-volume curve, the non-linear relationship between 44 average leaf or branch water potential and water content commonly used in plant hydraulics. The 45 sources of variability in these ecosystem-scale pressure-volume curves and their relationship to 46 forest response to water stress are discussed. We further show to what extent diel, seasonal, and 47 decadal dynamics of VWC reflect variations in different processes relating the tree response to 48 water stress. VWC can also be used for inferring belowground conditions – which are difficult to 49 impossible to observe directly. Lastly, we discuss how a dedicated geostationary spaceborne 50 observational system for VWC, when combined with existing datasets, can capture diel and 51 seasonal water dynamics to advance the science and applications of global forest vulnerability to 52 future droughts.

54 ENVIRONMENTAL SCIENCES↗

Advanced, Energy-Efficient Hybrid Membrane System for Industrial Water Reuse

In the U.S. manufacturing sector, current industrial water use practices are energy-intensive and utilize and discharge high volumes of waters, rendering them not sustainable especially in light of the growing scarcity of suitable water supplies. To help address this problem, the goal of this project was to develop an advanced, cost-effective, hybrid membrane-based water treatment system that can improve the energy efficiency of industrial wastewater treatment while allowing at least 50% water reuse efficiency. This hybrid process would combine emerging Forward Osmosis (FO) and Membrane Distillation (MD) technology components into an integrated FO-MD system that can beneficially utilize low-grade waste heat (i.e., T < 450 °F) in industrial facilities to produce distilled-quality product water for reuse. In this project, laboratory-, bench-, and pilot-scale experiments on the hybrid FO-MD system were conducted for industrial wastewater treatment. It was demonstrated at laboratory, bench, and pilot scales that FO-MD membrane technology can concentrate brine to very high total dissolved solids (TDS) levels (>200,000 ppm) that are at least 2.5 times higher than the TDS level to which RO can achieve. In laboratory testing, currently available FO and MD membranes were tested to select for high-performing membranes with high salt rejection and high water flux. Multiple FO membrane/draw-salt solution combinations that gave high water flux with higher than 98% salt rejection were also identified. Reverse draw-salt fluxes were observed to be much lower for divalent salts than for monovalent salts. MD membranes were identified that had 99.9+% salt rejection and water flux as high as 50-90 L/(m 2 ·h) for flat-sheet membranes and >20 L/(m 2 ·h) for hollow fibers. In bench-scale testing, a single unit of commercially available FO and MD membrane modules were evaluated for continuous, integrated operation. Using the laboratory- and bench-scale test data, numerical modeling was performed on the FO and MD processes to estimate engineering parameters for a larger-scale pilot unit. Based on the experimental studies and modeling results, a pilot-scale, integrated FO-MD prototype unit was designed and built for trailer-mounted operation. This prototype system was fed real industrial wastewater, which could not be further treated by conventional technologies, from an oil production facility and was successfully operated for over 15 weeks without major stoppage. About 90% water recovery was possible, while concentrating the TDS from 12,000 ppm up to 190,500 ppm. The FO-MD prototype rejected most wastewater contaminants while producing water with <300 ppm TDS, even when the feed TDS was higher than 150,000 ppm. No chemical cleaning was necessary during the pilot testing period. Flushing the system with dechlorinated tap water was sufficient to reset the membranes for the next set of test conditions. Pilot performance and membrane autopsy showed that, even though the feed was concentrated more than 10 times, membrane fouling was unnoticeable and no defects were detected on the FO and MD membrane surfaces. This project demonstrated the technical feasibility of the hybrid FO-MD process by taking water already treated to the limit with the highest level of current technologies and further concentrating it 10-fold by using mostly low-cost materials. Because no membranes suitable for full-scale plant applications are available at present, economical feasibility of the hybrid technology is still uncertain, but it is expected that broader industry participation can further reduce FO-MD process costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Simple Solution to a Complex Problem: Hexavalent Chromium in Landfill Storm water - 16129

Management of hexavalent chromium (Cr+6)-contaminated water at the Environmental Management Waste Management Facility (EMWMF) is a significant operational challenge, in addition to the challenges already posed by water management. The Cr+6 discharge criterion of 16 micrograms per liter (μg/L) is typically met; however, when demolition debris containing Cr+6 is received for disposal, concentrations up to 280 μg/L have been seen. The large volume of water generated at EMWMF from the 130-cm (51-in.) annual precipitation creates a complex water management problem that must be quickly addressed to maintain compliant landfill operations. The EMWMF Operations Team devised and implemented a simple, low-cost method to rapidly reduce the Cr+6 from the landfill storm water. The Cr+6 reduction system uses inexpensive, commercially available components of which the key is conventional steel wool in 760-L (200-gal) plastic bins. The Cr+6-impacted storm water is pumped through the bins, where the Cr+6 reacts with the elemental iron of the steel wool and reduces to trivalent chromium. The water then spills back into the ponds. Water is continuously recirculated through the bins until the release criterion is verified to be achieved, allowing the storm water to be discharged into the adjacent receiving stream. This cost-effective system is operated with in-house craft personnel, requiring only minimal additional training and hazard controls. The system can operate continuously with minimal intervention and has successfully processed millions of liters of storm water. The success of the initial installation has been refined over time, allowing Cr+6 reduction to proceed 24 hours a day and 7 days a week, with a Cr+6 reduction rate of about 20 μg/L per day. The system is scalable to achieve even higher reduction rates and adaptable to other metals. Through October 2015, over 65.1E6 L (17.2E6 gal) of contact water with Cr+6 above the release criterion was managed using the EMWMF system. This simple solution to a complex water management problem provides significant cost savings and operational efficiencies over traditional transportation and treatment at a water treatment facility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scenarios of Global Municipal Water-Use Demand Projections over the 21st Century

This paper establishes three future projections of global municipal water use to the end of the 21st century: A reference business-as usual (BAU) scenario, a High Technological Improvement (High Tech) scenario and a Low Technological Improvement (Low Tech) scenario. A global municipal water demand model is constructed using global water use statistics at the country-scale, calibrated to the base year of 2005, and simulated to the end of the 21st century. Since the constructed water demand model hinges on socioeconomic variables (population, income), water price, and end-use technology and efficiency improvement rates, projections of those input variables are adopted to characterize the uncertainty in future water demand estimates. The water demand model is linked to the Global Change Assessment Model (GCAM), a global change integrated assessment model. Under the reference scenario, the global total water withdrawal increases from 466 km3/year in 2005 to 941 km3/year in 2100,while withdrawals in the high and low tech scenarios are 321 km3/ year and 2000 km3/ year, respectively. This wide range (321-2000 km3/ year) indicates the level of uncertainty associated with such projections. The simulated global municipal demand projections are most sensitive to population and income projections, then to end-use technology and efficiency projections, and finally to water price. Thus, using water price alone as a policy measure to reduce municipal water use may substantiate the share of municipal water price of people’s annual incomes.

climate policy↗

Evolution of Electric Sector Water Use Under Alternative Electricity Futures

Increasing competition for water resources in the United States could create future challenges for allocating and using thermal cooling water in the U.S. electric power sector. While thermal power plant retirements and the growth of wind and solar technologies can reduce national aggregate power sector cooling water use, local water constraints and growing demand for agricultural or municipal supply could create greater needs for higher-cost alternative water supplies such as groundwater or recycled wastewater. For some regions, these incentives could change future electricity planning and operational decisions. These relationships and impacts are studied here using the National Renewable Energy Laboratory (NREL) Regional Energy Deployment System (ReEDS), a national electric sector planning model that has recently been upgraded to include a highly detailed representation of thermal cooling water demand and supply. Thermal power technologies are differentiated by both cooling technology and water source type to track and constrain thermal cooling water use in a way that incorporates both physical and legal water considerations in the United States. This capability is exercised under a range of electricity sector futures with alternative technology costs, fuel prices, and water constraints to illustrate ways that U.S. electric sector water use could evolve under uncertain future electric sector drivers. In exploring changes to regional generation and transmission planning and operation, water requirements, and cost, we highlight the environmental and economic impacts of future power sector water decisions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effect of moisture content of concrete on water uptake

The penetration of water and non-polar hexane in Portland cement mortar prisms with different initial moisture contents was investigated using nuclear magnetic resonance ({sup 1}H NMR). The amount of water in gel pores strongly affects the penetration of water in much larger capillary pores. Water penetration is reduced by the self-sealing effect as characterized by non-sq roott dependence of capillary uptake and penetration depth. This is explained by the ongoing redistribution of water from capillaries into gel pores which results in internal swelling and loss of continuity of the capillary pore system; a correlation was observed between the amount of redistributed water and departure from sq roott behaviour. A descriptive model is used to explain the dependence of water uptake and penetration on moisture content. For increasing initial moisture contents up to a critical value equivalent to equilibrium with a relative humidity between 65 and 80%, less penetrating water is able to redistribute. Thus more penetrating water is in larger capillaries with less viscous resistance; uptake and penetration depth increase. Above the critical initial moisture content, uptake and penetration depth decrease towards zero. This is explained by (a) an overall reduction in capillary pressure because transport takes places in fewer and larger pores and (b) an increase in viscous resistance due to the connection of penetrating capillary water with pores already containing water. Less capillary pore space is available for transport. The surface region of concrete placed in contact with water is not instantaneously saturated. Water content increases with time depending on the degree of surface saturation. A new transition coefficient for capillary suction gamma is defined for the calculation of surface flux.

36 MATERIALS SCIENCE↗

Effect of initial water saturation on the performance of fracturing fluids with and without polyallylamine under simulated EGS conditions

Objectives/Scope: StimuFrac (US Patents 9,873,828 B2 and 9,447,315 B2), a CO 2 - reactive polymer aqueous solution [polyallylamine (PAA) 1wt% in water] combined with CO 2 , can be used as a potentially less water-intensive fracturing fluid for enhanced geothermal systems (EGS). Our previous results show that in hot dry rock (HDR), PAA/CO 2 fracturing fluids outperformed other fluids such as water, CO 2 , and CO 2 /water in generating large fractures with less fluid consumed. The objective of this work is to investigate the effect of initial water saturation on the performance of StimuFrac by conducting hydraulic fracturing tests with ½ foot cubic rock samples held under representative EGS stress/temperature conditions and by using cyclic injection strategies (under constant injection rate). The resulting fracture hydraulic conductivities, breakdown pressures, and volumes of fluids required are compared. Methods/Procedures/Process: To simulate geothermal reservoir conditions, in all tests, the rock sample was held under triaxial confinement and at 200 °C, and different volumes of water were initially injected into the rock sample before any fracturing processes were initiated. For the single-cycle PAA (or water) alternating CO 2 (PAG or WAG) injection fracturing experiments, one complete cycle consisted of two steps: (1) injecting a PAA slug (or water slug) followed by (2) injecting CO 2 to initiate and propagate the fracture. For experiments involving multiple injection cycles, the CO 2 injection pressure is increased until it peaks and begins to decline (indicating fracture initiation at this moment), and then continued being injected for another 30 seconds to propagate the fracture. Then, these two-step cycles [injection of PAA (or water) followed by CO 2 injection (up to 2-4 mL/min)] are repeated. Applications/Significance/Novelty: The results of this study suggest that water saturation significantly affects the fracturing fluid transmission into the rock pore space, thus affecting the fracture initiation and propagation. In this study, fracturing tests via a single injection cycle or multiple injection cycles were performed. Splitting the rock samples in half after testing reveals that fracture propagation is significantly limited under high water saturation conditions (three-day initial water injection) compared to stimulation experiments performed in hot dry rock. The fractures propagate less than 1/3 of the distance from the wellbore to the outer rock surface, and in some cases, no fracture is generated. This may be caused by leak-off dominating the fracturing process and the fluid injection rate is insufficient to overcome leak-off, even under high injection rate conditions. Additionally, CO 2 could be leaking off into the wellbore annulus and this may be making it more difficult to generate sufficiently high-pressure gradients away from the near-wellbore region. Under low water saturation conditions (dry rock or after 1-day initial water injection), PAA/CO 2 consistently generated significantly larger fractures compared with the other fluids. CO 2 generated large fractures only in the hot dry rock and only when using high injection rates, though data variability is high.

58 GEOSCIENCES↗

The Kinetic Consequences of Water on Catalytic Methane Pyrolysis

Hydrogen production from biomass and natural gas has emerged as a prominent research area in response to the growing demand for energy from alternative sources that minimize CO 2 emissions. In this study, we investigate the impact of water, which is present in and generated from biomass-derived streams, on carbon nanotube (CNT) growth and hydrogen production during methane decomposition using Ni–Mo/MgO as a catalyst. We reveal here that the role of water on CNT growth is highly complex; its effect depends on the stage of growth at which the water is incorporated. When water is introduced at the beginning of methane decomposition ( t = 0 h), methane conversion rates are negatively impacted. We hypothesize that water inhibits the significant phase changes the Ni–Mo/MgO catalyst undergoes during catalyst carburization. In contrast, the incorporation of a small percentage of water after a stabilization period ( t = 3 h) results in methane conversion rate enhancements that scale with the introduced water partial pressure as water selectively reacts with amorphous carbon deposits that lead to catalyst deactivation, thus prolonging the lifetime of some of the most active sites. Moreover, water incorporation after stabilization significantly reduces the apparent activation energy. Density Functional Theory (DFT) calculations reveal that water preferentially interacts with carbon fragments on the catalyst surface to remove carbon deposits with a barrier lower than that required for methane activation, further supporting its role in cleaning active sites on the catalyst surface. Characterization of the resulting carbon nanotubes reveals the formation of more graphitic materials produced in the presence of water, highlighting the impact of water on nanotube properties. These results provide clarity toward the many ways in which water, or cofeeding of biomass-derived materials, may impact catalytic methane pyrolysis rates.

carbon nanotubes↗

Disentangling the Effects of Vapor Pressure Deficit and Soil Water Availability on Canopy Conductance in a Seasonal Tropical Forest During the 2015 El Niño Drought

In land models used in Earth system models, vegetation water stress is heuristically related to soil water matric potential, and root water uptake in soil layers is simply proportional to root density to meet the transpiration demand. The efficiency of roots utilizing deeper soil water under water stress cannot be well represented, but it is of critical importance for transpiration regulation and carbon flux. To improve modeling of tropical forest response to drought, a plant hydrodynamic scheme (HYDRO), adapted from a trait-based model in the Functionally Assembled Terrestrial Ecosystem Simulator (FATES), has been implemented in the Energy Exascale Earth System Model (E3SM) Land Model (ELM) to represent the hydraulic dynamics and root water uptake strategy. The adapted model conforms to the big-leaf photosynthesis model in ELM. Vegetation water stress in the model is a function of prognostic leaf water potential and is used to regulate stomatal conductance. Point simulations were performed at two tropical forest sites in the Amazon and Panama. Model sensitivity to the numerical solver, plant hydraulic traits, soil properties, and atmospheric forcing has been evaluated. Our results showed that, even though water stress factors calculated at our study sites using HYDRO are comparable to that simulated by the heuristic water stress model, soil moisture prediction is improved with soil water redistributions through roots. Simulated results using HYDRO is not as sensitive to plant hydraulic traits measured for different tree species as to the soil properties and atmospheric forcing. Simplified numerical solver may cause inaccuracy as to where roots uptake water. This study suggests that plant hydrodynamic representation is critical for improved simulations of soil moisture under water stresses.

54 ENVIRONMENTAL SCIENCES↗

On the nature of the molecular ordering of water in aqueous DMSO mixtures

Computer simulation studies of aqueous dimethyl sulfoxyde (DMSO) mixtures show micro-heterogeneous structures, just like aqueous alcohol mixtures. However, there is a marked difference in the aggregate structure of water between the two types of systems. While water molecules form multiconnected globular clusters in alcohols, we report herein that the typical water aggregates in aqueous DMSO mixtures are linear, favouring a 2 hydrogen bond structure per water molecule, and for all DMSO mole fractions ranging from 0.1 to 0.9. This linear-aggregate structure produces a particular signature in the water site-site structure factors, in the form of a pre-peak at k ≈ 0.2–0.8 Å{sup −1}, depending on DMSO concentration. This pre-peak is either absent in other aqueous mixtures, such as aqueous methanol mixtures, or very difficult to see through computer simulations, such as in aqueous-t-butanol mixtures. This difference in the topology of the aggregates explains why the Kirkwood-Buff integrals of aqueous-DMSO mixture look nearly ideal, in contrast with those of aqueous alcohol mixtures, suggesting a connection between the shape of the water aggregates, its fluctuations, and the concentration fluctuations. In order to further study this discrepancy between aqueous DMSO and aqueous alcohol mixture, two models of pseudo-DMSO are introduced, where the size of the sulfur atom is increased by a factor 1.6 and 1.7, respectively, hence increasing the hydrophobicity of the molecule. The study shows that these mixtures become closer to the emulsion type seen in aqueous alcohol mixtures, with more globular clustering of the water molecules, long range domain oscillations in the water-water correlations and increased water-water Kirkwood-Buff integrals. It demonstrates that the local ordering of the water molecules is influenced by the nature of the solute molecules, with very different consequences for structural properties and related thermodynamic quantities. This study illustrates the unique plasticity of water in presence of different types of solutes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Framework Using Applied Process Analysis Methods to Assess Water Security in the Vu Gia–Thu Bon River Basin, Vietnam

The Vu Gia–Thu Bon (VG–TB) river basin is facing numerous challenges to water security, particularly in light of the increasing impacts of climate change. These challenges, including salinity intrusion, shifts in rainfall patterns, and reduced water supply in downstream areas, are of great concern. This study comprehensively assessed the current state of water security in the basin using robust statistical analysis methods such as the Process Analysis Method (PAM), SMART principle, and Analytic Hierarchy Process (AHP). This resulted in the development of a comprehensive assessment framework for water security in the VG–TB river basin. This framework identified five key dimensions, with basin development activities (0.32), the ability to meet water needs (0.24), and natural disaster resilience (0.19) being the most crucial and water resource potential being the least crucial (0.11) according to the AHP methodology. The latter also highlighted 15 indicators, four of which are particularly influential, including waste resources (0.54), flood (0.53), water storage capacity (0.45), and basin governance (0.42). Furthermore, 28 variables with high weight factors were identified. This framework aligns with the UN-Water water security definition and addresses the global water sustainability criteria outlined in Sustainable Development Goal 6 (SDG6). It enables the computation of a comprehensive Water Security Index (WSI) for specific regions, providing a strong foundation for decision-making and policy formulation. It aims to enhance water security in the context of climate change and support sustainable basin development, thereby guiding future research and policy decisions in water resource management.

54 ENVIRONMENTAL SCIENCES↗

HarDWR - Water Management Area (WMA) Shapefiles

A dataset within the Harmonized Database of Western U.S. Water Rights (HarDWR). For a detailed description of the database, please see the meta-record v2.0. Changelog v2.0 - No changes v1.0 - Initial public release Description Borders of all Water Management Areas (WMAs) across the 11 western-most states of the coterminous United States are available filtered through a single source. The legal name for this set of boundaries varies state-by-state. The data is provided as two compressed shapefiles. One, stateWMAs, contains data for all 11 states. For 10 of those states, Arizona being the exception, the polygons represent the legal management boundaries used by those states to manage their surface and groundwater resources respectively. WMAs refer to the set of boundaries a particular state uses to manage its water resources. Each set of boundaries was collected from the states individually, and then merged into one spatial layer. The merging process included renaming some columns to enable merging with all other source layers, as well as removing columns deemed not required for followup analysis. The retained columns for each boundary are: basinNum - the state provided unique numerical ID; basinName - the state provided English name of the area, where applicable; state - the state name; and uniID - a unique identifier we created by concatenating the state name, and underscore, and the state numerical ID. Arizona is unique within this collection of states in that surface and groundwater resources are managed using two separate sets of boundaries. During our followup analysis (Grogan et al., in review) we decided to focus on one set of boundaries, those for surface water. This is due to the recommendation of our hydrologists that the surface water boundary set is a more realist representation of how water moves across the landscape, as a few of the groundwater boundaries are based on political and/or economic considerations. Therefore, the Arizona surface WMAs are included within stateWMAs. The Arizona groundwater WMAs are provided as a separate file, azGroundWMAs, as a companion to the first file for completeness and general reference. WMA spatial boundary data sources by state: Arizona: Arizona Surface Water Watersheds; Collected February, 2020; https://gisdata2016-11-18t150447874z-azwater.opendata.arcgis.com/datasets/surface-watershed/explore?location=34.158174%2C-111.970823%2C7.50 Arizona: Arizona Ground Water Basins; Collected February, 2020; https://gisdata2016-11-18t150447874z-azwater.opendata.arcgis.com/datasets/groundwater-basin-2/explore?location=34.158174%2C-111.970823%2C7.50 California: California CalWater 2.2.1; Collected February, 2020; https://www.mlml.calstate.edu/mpsl-mlml/data-center/data-entry-tools/data-tools/gis-shapefile-layers/ Colorado: Colorado Water District Boundaries; Collected February, 2020; https://www.colorado.gov/pacific/cdss/gis-data-category Idaho: Idaho Department of Water Resources (IDWR) Administrative Basins; Collected November, 2015; https://data-idwr.opendata.arcgis.com/datasets/fb0df7d688a04074bad92ca8ef74cc26_4/explore?location=45.018686%2C-113.862284%2C6.93 Montana: Collected June, 2019; Directly contacted Montana Department of Natural Resources and Conservation (DNRC) Office of Information Technology (OIT) Nevada: Nevada State Engineer Admin Basin Boundaries; Collected April, 2020 https://ndwr.maps.arcgis.com/apps/mapviewer/index.html?layers=1364d0c3a0284fa1bcd90f952b2b9f1c New Mexico: New Mexico Office of the State Engineer (OSE) Declared Groundwater Basins; Collected April, 2020 https://geospatialdata-ose.opendata.arcgis.com/datasets/ose-declared-groundwater-basins/explore?location=34.179783%2C-105.996542%2C7.51 Oregon: Oregon Water Resources Department (OWRD) Administrative Basins; Collected February, 2020; https://www.oregon.gov/OWRD/access_Data/Pages/Data.aspx Utah: Utah Adjudication Books; Collected April, 2020; https://opendata.gis.utah.gov/datasets/utahDNR::utah-adjudication-books/explore?location=39.497165%2C-111.587782%2C-1.00 Washington: Washington Water Resource Inventory Areas (WRIA); Collected June, 2017; https://ecology.wa.gov/Research-Data/Data-resources/Geographic-Information-Systems-GIS/Data Wyoming: Wyoming State Engineer's Office Board of Control Water Districts; Collected June, 2019; Directly contacted Wyoming State Engineer's Office

Economics↗

Representing Water Scarcity in Future Agricultural Assessments

Globally, irrigated agriculture is both essential for food production and the largest user of water. A major challenge for hydrologic and agricultural research communities is assessing the sustainability of irrigated croplands under climate variability and change. Simulations of irrigated croplands generally lack key interactions between water supply, water distribution, and agricultural water demand. In this article, we explore the critical interface between water resources and agriculture by motivating, developing, and illustrating the application of an integrated modeling framework to advance simulations of irrigated croplands. We motivate the framework by examining historical dynamics of irrigation water withdrawals in the United States and quantitatively reviewing previous modeling studies of irrigated croplands with a focus on representations of water supply, agricultural water demand, and impacts on crop yields when water demand exceeds water supply. We then describe the integrated modeling framework for simulating irrigated croplands, which links trends and scenarios with water supply, water allocation, and agricultural water demand. Finally, we provide examples of efforts that leverage the framework to improve simulations of irrigated croplands as well as identify opportunities for interventions that increase agricultural productivity, resiliency, and sustainability.

Irrigated Agriculture; Crop Model; Hydrologic Mode↗

Testing and validation of the microbial environment of the NASA rodent spaceflight habitat water delivery system.

Sterilized, deionized water within a closed, self-sufficient system has been used in NASA spaceflight rodent studies for several decades. Within the specialized spaceflight rodent habitat, water is delivered through a compression spring-loaded bag system to maintain positive pressure. Refill of the drinking water occurs every 30 days by direct transfer of potable water from aboard the International Space Station (ISS). This enables long term use without a weekly water change out, which meets spaceflight requirements, but contrasts with the general guidelines for the sanitation of water delivery systems. Even though the water is iodinated to minimize microbial growth, rodents are fed a special diet of high moisture nutrient-rich food bars based on the AIN-93 diet that may contribute to microbial growth in this water system. We designed a ground study to assess the quality of drinking water that is given to rodents throughout a mission. We conducted the ground test using 20 female C57BL/6J mice housed in this specialized habitat to mimic the timeline of a 90-day mission as well as the environmental conditions (temperature, humidity, and pCO2) within the ISS. We used a novel sampling method to test water at 2-week intervals for the 90-days, and also after each 30-day refill of the water delivery system. Mice in standard vivarium cages with water bottles were also included for comparison to the habitat. The results showed that overall microbial load remained close to zero for the duration, while total organic compound concentrations increased from 1370g/L to 10650g/L over the course of 90 days but remained below the level of concern. Inorganic ions and pH were also found to be at acceptable levels. Overall, we conclude that this system is effective in delivering clean, potable water to rodents for the 90-day duration of current missions to the ISS.

water↗

Energy and water in the Western and Texas interconnects.

The Department of Energy's Office of Electricity has initiated a $60M program to assist the electric industry in interconnection-level analysis and planning. The objective of this effort is to facilitate the development or strengthening of capabilities in each of the three interconnections serving the lower 48 states of the United States, to prepare analyses of transmission requirements under a broad range of alternative futures and develop long-term interconnection-wide transmission expansion plans. The interconnections are the Western Interconnection, the Eastern Interconnection, and the Texas Interconnection. One element of this program address the support and development of an integrated energy-water Decision Support System (DSS) that will enable planners in the Western and Texas Interconnections to analyze the potential implications of water stress for transmission and resource planning (the Eastern Interconnection is not participating in this element). Specific objectives include: (1) Develop an integrated Energy-Water Decision Support System (DSS) that will enable planners in the Western and Texas Interconnections to analyze the potential implications of water stress for transmission and resource planning. (2) Pursue the formulation and development of the Energy-Water DSS through a strongly collaborative process between members of this proposal team and the Western Electricity Coordinating Council (WECC), Western Governors Association (WGA), the Electric Reliability Council of Texas (ERCOT) and their associated stakeholder teams. (3) Exercise the Energy-Water DSS to investigate water stress implications of the transmission planning scenarios put forward by WECC, WGA, and ERCOT. The goals of this project are: (1) Develop an integrated Energy-Water Decision Support System (DSS) that will enable planners to analyze the potential implications of water stress for transmission and resource planning. (2) Pursue the formulation and development of the Energy-Water DSS through a strongly collaborative process between Western Electricity Coordinating Council, Electric Reliability Council of Texas, Western Governors Association, and Western States Water Council. (3) Exercise the Energy-Water DSS to investigate water transmission planning scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Novel Absorption Cycle for Combined Water Heating, Dehumidification, and Evaporative Cooling

In this study, development of a novel system for combined water heating, dehumidification, and space evaporative cooling is discussed. Ambient water vapor is used as a working fluid in an open system. First, water vapor is absorbed from an air stream into an absorbent solution. The latent heat of absorption is transferred into the process water that cools the absorber. The solution is then regenerated in the desorber, where it is heated by a heating fluid. The water vapor generated in the desorber is condensed and its heat of phase change is transferred to the process water in the condenser. The condensed water can then be used in an evaporative cooling process to cool the dehumidified air exiting the absorber, or it can be drained if primarily dehumidification is desired. Essentially, this open absorption cycle collects space heat and transfers it to process water. This technology is enabled by a membrane-based absorption/desorption process in which the absorbent is constrained by hydrophobic vapor-permeable membranes. Constraining the absorbent film has enabled fabrication of the absorber and desorber in a plate-and-frame configuration. An air stream can flow against the membrane at high speed without entraining the absorbent, which is a challenge in conventional dehumidifiers. Furthermore, the absorption and desorption rates of an absorbent constrained by a membrane are greatly enhanced. Isfahani and Moghaddam (Int. J. Heat Mass Transfer, 2013) demonstrated absorption rates of up to 0.008 kg/m2s in a membrane-based absorber and Isfahani et al. (Int. J. Multiphase Flow, 2013) have reported a desorption rate of 0.01 kg/m2s in a membrane-based desorber. The membrane-based architecture also enables economical small-scale systems, novel cycle configurations, and high efficiencies. The absorber, solution heat exchanger, and desorber are fabricated on a single metal sheet. In addition to the open arrangement and membrane-based architecture, another novel feature of the cycle is recovery of the solution heat energy exiting the desorber by process water (a process-solution heat exchanger ) rather than the absorber exiting solution (the conventional solution heat exchanger ). This approach has enabled heating the process water from an inlet temperature of 15 C to 57 C (conforming to the DOE water heater test standard) and interfacing the process water with absorbent on the opposite side of a single metal sheet encompassing the absorber, process-solution heat exchanger, and desorber. The system under development has a 3.2 kW water heating capacity and a target thermal coefficient of performance (COP) of 1.6.

Absorption Heat Pump↗