Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Control and Grid Support Function Evaluation for a Three-Phase Back-to-Back Modular Multilevel Converter System

This paper focuses on the evaluation of advanced inverter controls for a 500kW back-to-back (B2B), silicon carbide, multilevel modular converter (MMC) used as a direct-connected medium-voltage grid intertie. A decentralized hierarchical controller architecture for the MMC system is presented, which uses the main controller to implement higher level grid interconnection functions per the IEEE 1547–2018 standards and the local controllers to execute lower level closed-loop functionality of the MMC stages. This paper presents and elaborates on the grid functionalities are elaborated and presented. The back-to-back converter system is equipped with local controllers and their corresponding functionalities are presented. Case study results for the corresponding functionalities presented show the effectiveness of the proposed architecture. To enhance the operation capabilities of the system, a parameter update scheme has been implemented and utilized in unison with the controller.

decentralized control↗

Inrush Current Control Circuit

An inrush current control circuit having an input terminal connected to a DC power supply and an output terminal connected to a load capacitor limits the inrush current that charges up the load capacitor during power up of a system. When the DC power supply applies a DC voltage to the input terminal, the inrush current control circuit produces a voltage ramp at the load capacitor instead of an abrupt DC voltage. The voltage ramp results in a constant low level current to charge up the load capacitor, greatly reducing the current drain on the DC power supply.

Cole, Steven W.↗

Supply voltage decoupling circuits for voltage droop mitigation

Circuits and methods are provided for utilizing decoupling capacitors to mitigate voltage droop on power supply lines of a power distribution network. A power supply line is capacitively decoupled using a first decoupling capacitor connected to the power supply line and charged to a first voltage level of the power supply line. A second decoupling capacitor is pre-charged to a second voltage level greater than the first voltage level and held in standby. A control circuit determines or predicts an occurrence of a droop event in which the first voltage decreases to a level which is at or below a droop threshold voltage level, and selectively connects the pre-charged second decoupling capacitor to the power supply line to source additional boosting current through discharging of the second decoupling capacitor and thereby capacitively decouple the power supply line using the higher second voltage and additional boosting current.

Zhang, Xin↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System: Preprint

This paper develops improved control strategy of GFM inverter with fault ride-through (FRT) capabilities to guarantee stable operation of microgrid under fault conditions especially islanded microgrid and asymmetrical faults. The proposed control strategy includes dual control of positive-sequence and negative-sequence control, and the adaptive virtual impedance (VI) control. Unlike the existing works, the proposed strategy only applies the VI control for the d-component of the positive-sequence control and leaves the q-component of positive-sequence control and dq-component of negative-sequence control zero, thus achieving the improved stability and balanced three-phase voltage under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults which could cause saturated inner current loop and instability if the VI is not adaptive. Simulation results of a phase-to-phase-ground fault show that the proposed control strategy improves the stability of GFM and achieves the stable and balanced output voltages in islanded microgrid.

fault ride-through↗

Real-Time Testbed for Smart Grid Recloser Controller

The growing need for a low voltage recloser has become apparent due to the rise in requirements for a smart grid. This includes more detailed management of power flow forward (towards load) and backward (towards generation), source synchronization in real time, more indepth fault responses, and the use of green energy. The SEL-651R-2 relay is a device that can manage these needs, especially in fault response and synchronization, and is commonly used in systems called microgrids. Microgrids are distribution level systems that are able to operate separated from the main grid, are typically installed much closer to the load(s), and are fed by distributed energy resources (DERs), such as wind, solar or diesel generators. The SEL-651R-2 is normally used in the field with presets operative settings, but the Western Michigan University (WMU) Center for Interdisciplinary Research on Secure, Efficient and Sustainable Energy Technology (WMU InterEnergy Center) wished to test this device in its range of capabilities for microgrid application. A Hardware-In-the-Loop (HIL) testbed was implemented and used through the Real Time Digital Simulator (RTDS) using the RSCAD software to test the SEL-651R-2's use cases and functions. The testbed includes a microgrid with interconnection to a larger main grid, and the relay is meant to control the recloser at the point of common coupling (PCC) between the main grid and microgrid. The testbed shows how basic protections, reclosing, and synchronization checks function when handling faults that affect both the microgrid and the main grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Overvoltage Prevention and Curtailment Reduction Using Adaptive Droop-Based Supplementary Control in Smart Inverters

Recent developments in the renewable energy sector have seen an unprecedented growth in residential photovoltaic (PV) installations. However, high PV penetration levels often lead to overvoltage problems in low-voltage (LV) distribution feeders. Smart inverter control such as active power curtailment (APC)-based overvoltage control can be implemented to overcome these challenges. The APC technique utilizes a constant droop-based approach which curtails power rigidly, which can lead to significant energy curtailment in the LV distribution feeders. In this paper, different variations of the APC technique with linear, quadratic, and exponential droops have been analyzed from the point-of-view of energy curtailment for a LV distribution network in North America. Further, a combinatorial approach using various droop-based APC methods in conjunction with adaptive dynamic programming (ADP) as a supplementary control scheme has also been proposed. The proposed approach minimizes energy curtailment in the LV distribution network by adjusting the droop gains. Simulation results depict that ADP in conjunction with exponential droop reduces the energy curtailment to approximately 50% compared to using the standard linear droop.

42 ENGINEERING↗

Assessment and Commissioning of Electrical Substation Grid Testbed with a Real-Time Simulator and Protective Relays/Power Meters in the Loop

Electrical utility substations are wired with intelligent electronic devices (IEDs), such as protective relays, power meters, and communication switches. Substation engineers commission these IEDs to assess the appropriate measurements for monitoring, control, power system protection, and communication applications. Like real electrical utility substations, complex electrical substation grid testbeds (ESGTs) need to be assessed for measuring current and voltage signals in monitoring, power system protection, control (synchro check), and communication applications that are limited by small measurement percentage errors. In the process of setting an ESGT with real-time simulators and IEDs in the loop, protective relays, power meters, and communication devices must be commissioned before running experiments. In this study, an ESGT with IEDs and distributed ledger technology was developed. The ESGT with a real-time simulator and IEDs in the loop was satisfactorily assessed and commissioned. The commissioning and problem-solving tasks of the testbed are described to define a method with flowcharts to assess possible trouble-shooting in ESGTs. This method was based on comparing the simulations versus IED measurements for the phase current and voltage magnitudes, three-phase phasor diagrams, breaker states, protective relay times with selectivity coordination at electrical faults, communication data points, and time-stamp sources.

Piesciorovsky, Emilio↗

A Hierarchical OPF Algorithm with Improved Gradient Evaluation in Three-Phase Networks

Linear approximation commonly used in solving alternating-current optimal power flow (AC-OPF) simplifies the system models but incurs accumulated voltage errors in large power networks. Such errors will make the primal-dual type gradient algorithms converge to solutions with voltage violation. In this paper, we improve a recent hierarchical OPF algorithm that rested on primal-dual gradients evaluated with a linearized distribution power flow model. Specifically, we propose a more accurate gradient evaluation method based on an unbalanced three-phase nonlinear distribution power flow model to mitigate the errors arising from linearization. The resultant gradients feature a blocked structure that enables our development of an improved hierarchical primal-dual algorithm to solve the OPF problem. Numerical results on the IEEE 123-bus test feeder and a 4,518-node test feeder show that the proposed method can enhance voltage safety at comparable computational efficiency with the linearized algorithm.

approximation algorithms↗

High Voltage Regrown GaN P-N Diodes Enabled by Defect and Doping Control

This project studied and implemented methods to form GaN p-n diodes using selective area regrowth to achieve selective area doping. Successful selective area doping of GaN p-n diodes is an enabling factor to realize more advanced devices such as vertical transistors. The general challenge to selective area regrowth of GaN is that the primary etch method, inductively coupled plasma (ICP), damages the crystal and causes high leakage when didoes are formed by regrowth on the etched surface. Our approach used low damage etch methods following ICP etch to remove crystal damage and reduced leakage in the regrown diode. This project demonstrated 1.6 kV etched-and-regrown GaN p-n diodes using planar (non-selective) regrowth and 840 V etched-and-regrown p-n diodes using selective area regrown. Enabling factors were use of a low-damage reactive ion etch (RIE) to remove damage caused by the primary ICP etch combined with a multi-step junction terminal extension (JTE) process. Deep level defect investigation quantitatively correlated a deep level near the middle of the GaN band gap with ICP etch-induced leakage that was greatly mitigated by using a slow, low damage RIE process. This research is economically feasible for commercialization because the processes used in this project, including substrate type and source, epitaxial crystal growth and fabrication techniques are all standard to the GaN semiconductor industry. The fundamental understanding and foundational ability to produce kV-class GaN p-n diodes through etch-and-regrowth provides a path to realize high power, high efficiency GaN power switches that can significantly outperform commercial devices for next-generation electrical power conversion and transmission systems.

36 MATERIALS SCIENCE↗

Improvements in and test results for the 2 to 15 kilowatt Brayton cycle electrical subsystem

The electrical subsystem of the 2- to 15-kW Brayton power conversion system consists of the auxiliary electrical equipment required for an integrated, self-contained system. For the last 2 years the electrical subsystem has been undergoing extensive tests. The first year of testing resulted in determining the performance characteristics of the electrical subsystem. During the second year several significant changes and improvements were investigated. An inverter designed for motor starting the alternator performed successfully. Some of the changes that have been made are a new alternator speed pickup, which is independent of the alternator output voltage; new, more efficient power supplies for the control system; and a volts-per-hertz reference for the alternator voltage regulator. Test data were taken on the temperature distribution of the electrical subsystem at startup conditions over a cold-plate temperature range of 25 to -50 C.

Vrancik, J. E.↗