Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Quantifying the Solar Energy Resource for Puerto Rico

After Hurricane Maria, multiple U.S. Department of Energy laboratories studied the state of the electric grid in Puerto Rico and analyzed grid resilience and grid integration of renewable energy. As part of the work done at the National Renewable Energy Laboratory, researchers created new solar resource data, conducted a technical potential and supply curve analysis, and studied the interannual variability of the solar resource. A new methodology was developed to downscale solar resource data from the National Solar Radiation Data Base (NSRDB) from a 4-km x 4-km spatial and 30-minute temporal resolution to a 2 km x 2 km and 5-minute resolution. This methodology primarily used simple physical principles to develop high-resolution cloud properties which were then used to compute solar radiation. The high-resolution datasets were validated against ground measurements and the error metrics were found to be similar to the original lower resolution dataset. Using 20 years of downscaled data from the NSRDB multi-year capacity factors for photovoltaics (PV) were developed for both single-axis tracking and fixed latitude-tilt configurations. Use of the multi-year data provides the ability to understand variability in capacity factors due to variability in weather over a long period of time. For Puerto Rico the coastal regions were found to have significant higher capacity factors than inland. Using land-use and terrain information a technical potential analysis was conducted for Puerto Rico. This analysis restricted single PV plant development to a maximum of 100 MW nameplate capacity. The nameplate capacity for each municipality were then determined. Based on our assumptions, 56 of the 78 total municipalities of Puerto Rico contain some level of solar capacity. Most of the interior municipalities did not have any capacity because of the geographic exclusions used in this study. The lowest capacity for a PV plant observed in a municipality was 10 MW. The maximum capacity within a county was 2,000 MW. Further a supply curve analysis was conducted by taking the results of the technical potential and quantifying system and transmission costs. The levelized cost of energy (LCOE) was calculated for each theoretical PV plant site, and the levelized cost of transmission was added to the LCOE to produce a total cost estimate for each site. The results of the supply curve analysis allow for a relative comparison of the cost for integrating new PV capacity into the grid. This analysis indicates that cheaper total LCOE sites tend to be larger in capacity. The total capacity in this study was found to be far beyond the maximum peak load for the island. However, this study does not consider the economic and market potential for development. The cumulative capacity presented in this study assumes that the best locations are developed first and ignores the complex decision paths for new power plant development. Therefore, this analysis can only be treated as illustrative. Finally this study investigates the impact of inter-annual variability of resource using a variety of metrices including probability of exceedance and variation in capacity factor and LCOE. This study demonstrates that the capacity factor or LCOE could vary by over 10% year to year. This clearly indicates the risks involved in using any particular year of data and clearly points to the use of multi-year data to reduce some of the risks related to variability in weather.

14 SOLAR ENERGY↗

Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine (Final Report)

As the nation continues to encourage, through market structures and financial incentives, the proliferation of intermittent renewable electricity, how to optimize the ever-changing electric grid and identify means to retain and improve resilience, while ensuring continued reductions in GHG emissions, will be critical. According to Bloomberg, wind & solar generated 10.5% of US electricity in 2020 and that percentage continues to grow. In support of expanding renewable energy use, and to address its intermittent nature, this project will develop the Hydrogen Storage for Flexible Fossil Fuel Power Generation platform that is dispatchable, reliable, repeatable and have the ability to produce zero or negative carbon power while interfacing with geology capable of CO2 and hydrogen storage. GTI Energy (GTIE) and team members Illinois State Geological Survey (ISGS), Mitsubishi Heavy Industries America (MHIA), Ameren Illinois, Hexagon Purus, and the Low Carbon Resources Initiative (LCRI) completed a Phase I Conceptual Study under contract DE-FE0032012 for Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine. The Hydrogen Storage for Flexible Fossil Fuel Power Generation platform addresses the intermittent nature of the expanding use of Variable Renewable Energy (VRE) generation. The low cost of the electricity (COE) generated results in greater dispatch and more operation at higher power levels (higher efficiency), fewer short intervals, and fewer start/stop cycles. The reliable, resilient system can produce zero carbon power and store hydrogen. It will demonstrate hydrogen storage in geologic formations like those used in natural gas underground storage thus enabling large scale storage of hydrogen in sedimentary strata across the United States rather than in geographically restricted salt caverns. The Phase I study confirmed the system is feasible and generates power at lower cost than other low carbon approaches. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production. The study advanced the maturity of the H 2 storage-based system with flexible power generation by completing a Pre-FEED study (Phase II). The Pre-FEED focused on the selected Energy Farm on the University of Illinois Urbana-Champaign (UIUC) site that includes above ground and underground hydrogen storage, low-carbon hydrogen production (GTI’s Compact Hydrogen Generator, CHG) with underground CO2 sequestration, and a 40-MW class gas turbine. The Pre-FEED addressed the entire system and its interconnection to the natural gas and electric grid and mitigation of key risks, such as storage behavior, load-following, and system operation. During Phase 1 of the project, the team completed key tasks, which moved the entire demonstration project, specific components and approaches closer to commercialization. These Phase I Accomplishments include: Completing System Requirements Review; Completing System Layout and Modeling - Heat & Mass Balance and Process Flow Diagram; Completing modelling of 9 turbine performance cases; Evaluating rock strata for underground storage of hydrogen and sequestration of carbon dioxide; Completing initial modelling of underground storage of hydrogen and withdrawal with evaluation of loss and water production; Identifying roadable storage for above ground hydrogen storage; Identifying existing electrical infrastructure for receiving/delivering electricity; Identifying existing gas supply infrastructure for receiving natural gas; Document concept design/development plans in required reports. Conclusions: The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and generates power at lower cost than other low carbon approaches and even lower cost than the reference NGCC plant without carbon capture when taking advantage of 45Q carbon credits. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via the system requirements review with the whole team. These requirements were then incorporated into and iterated with our Heat & Mass Balance process model and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Large scale non-salt geologic storage of hydrogen is an enabling technology for a hydrogen-fired turbine that can be retrofitted into large-scale electric generating units (EGU). Our demonstration will include 428 MWh or ~4 hours full load of hydrogen storage (above and underground). Carbon capture inherent to the CHG process can capture 90% CO 2 (with upgrades to >98%). This system provides a COE of 23% savings relative to an NGCC with a post combustion amine system. Our proposed storage system decouples carbon capture and hydrogen production from power production; therefore, we expect our proposed system’s efficiency and variable COE to be superior resulting in overall higher dispatch and reduced deep cycling. Our demonstration will be full to multi-day hydrogen storage and has the potential for longer (seasonal) duration commercially. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production.

03 NATURAL GAS↗

Computational Analyses in Support of Sub-scale Diffuser Testing for the A-3 Facility: Steady Predictions - Part 1

Simulation technology can play an important role in rocket engine test facility design and development by assessing risks, providing analysis of dynamic pressure and thermal loads, identifying failure modes and predicting anomalous behavior of critical systems. Advanced numerical tools assume greater significance in supporting testing and design of high altitude testing facilities and plume induced testing environments of high thrust engines because of the greater inter-dependence and synergy in the functioning of the different sub-systems. This is especially true for facilities such as the proposed A-3 facility at NASA SSC because of a challenging operating envelope linked to variable throttle conditions at relatively low chamber pressures. Facility designs in this case will require a complex network of diffuser ducts, steam ejector trains, fast operating valves, cooling water systems and flow diverters that need to be characterized for steady state performance. In this paper, we will demonstrate with the use of CFD analyses s advanced capability to evaluate supersonic diffuser and steam ejector performance in a sub-scale A-3 facility at NASA Stennis Space Center (SSC) where extensive testing was performed. Furthermore, the focus in this paper relates to modeling of critical sub-systems and components used in facilities such as the A-3 facility. The work here will address deficiencies in empirical models and current CFD analyses that are used for design of supersonic diffusers/turning vanes/ejectors as well as analyses for confined plumes and venting processes. The primary areas that will be addressed are: (1) supersonic diffuser performance including analyses of thermal loads (2) accurate shock capturing in the diffuser duct; (3) effect of turning duct on the performance of the facility (4) prediction of mass flow rates and performance classification for steam ejectors (5) comparisons with test data from sub-scale diffuser testing and assessment of confidence levels in CFD based flowpath modeling of the facility. The analyses tools used here expand on the multi-element unstructured CFD which has been tailored and validated for impingement dynamics of dry plumes, complex valve/feed systems, and high pressure propellant delivery systems used in engine and component test stands at NASA SSC. The analyses performed in the evaluation of the sub-scale diffuser facility explored several important factors that influence modeling and understanding of facility operation such as (a) importance of modeling the facility with Real Gas approximation, (b) approximating the cluster of steam ejector nozzles as a single annular nozzle, (c) existence of mixed subsonic/supersonic flow downstream of the turning duct, and (d) inadequacy of two-equation turbulence models in predicting the correct pressurization in the turning duct and expansion of the second stage steam ejectors. The procedure used for modeling the facility was as follows: (i) The engine, test cell and first stage ejectors were simulated with an axisymmetric approximation (ii) the turning duct, second stage ejectors and the piping downstream of the second stage ejectors were analyzed with a three-dimensional simulation utilizing a half-plane symmetry approximation. The solution i.e. primitive variables such as pressure, velocity components, temperature and turbulence quantities were passed from the first computational domain and specified as a supersonic boundary condition for the second simulation. (iii) The third domain comprised of the exit diffuser and the region in the vicinity of the facility (primary included to get the correct shock structure at the exit of the facility and entrainment characteristics). The first set of simulations comprising the engine, test cell and first stage ejectors was carried out both as a turbulent real gas calculation as well as a turbulent perfect gas calculation. A comparison for the two cases (Real Turbulent and Perfect gas turbulent) of the Ma Number distribution and temperature distributions are shown in Figures 1 and 2 respectively.

Allgood, Daniel C.↗

Experimental Structural Dynamic Response of Plate Specimens Due to Sonic Loads in a Progressive Wave Tube

The objective of the current study was to assess the repeatability of experiments at NASA Langley's Thermal Acoustic Fatigue Apparatus (TAFA) facility and to use these experiments to validate numerical models. Experiments show that power spectral density (PSD) curves were repeatable except at the resonant frequencies, which tended to vary between 5 Hz to 15 Hz. Results show that the thinner specimen had more variability in the resonant frequency location than the thicker sample, especially for modes higher than the first mode in the frequency range. Root Mean Square (RMS) tended to be more repeatable. The RMS behaved linearly through the SPL range of 135 to 153 dB. Standard Deviations (STDs) of the results tended to be relatively low constant up to about 147 dB. The RMS results were more repeatable than the PDS results. The STD results were less than 10% of the RMS results for both the 0.125 in (0.318 cm) and 0.062 in (0.1588 cm) thick plate. The STD of the PSD results were around 20% to 100% of the mean PSD results for non-resonant and resonant frequencies, respectively, for the 0.125 in (0.318 cm) thicker plate and between 25% to 125% of the mean PSD results, for nonresonant and resonant frequencies, respectively, for the thinner plate.

Betts, Juan F.↗

Impact of Climatic Variability on Atmospheric Mass Distribution and GRACE-Derived Gravity Fields

During the period we calculated the atmospheric data sets related to its mass and angular momentum distribution. For mass, we determined the various harmonics from the NCEP-NCAR reanalysis, especially the low-order harmonics that are useful in studying the gravitation distribution as will be determined from the GRACE mission. Atmospheric mass is also related to the atmospheric loading on the solid Earth; we cooperated with scientists who needed the atmospheric mass information for understanding its contributions to the overall loading, necessary for vertical and horizontal coordinate estimation. We calculated atmospheric angular momentum from the NCEP-NCAR reanalyses and 4 operational meteorological centers, based on the motion (wind) terms and the mass (surface pressure) terms. These are associated with motions of the planet, including its axial component causing changes in the length of day, more related to the winds, and the equatorial component related to motions of the pole, more related to the mass. Tasks related to the ocean mass and angular momentum were added to the project as well. For these we have noted the ocean impact on motions of the pole as well as the torque mechanisms that relate the transfer of angular momentum between oceans and solid earth. The activities of the project may be summarized in the following first manuscript written in December 2002, for a symposium that Dr. Salstein attended on Geodynamics. We have continued to assess ocean angular momentum (OAM) quantities derived from bottom pressure and velocity fields estimated with our finite-difference barotropic (single layer) model. Three years of output (1993-95) from a run without any data constraints was compared to output from a corresponding run that was constrained by altimeter data using a Kalman filter and smoother scheme. Respective OAM time series were combined with corresponding atmospheric series and compared to observed polar motion. The constrained OAM series provided slightly better variance reduction than the unconstrained series. Analysis provided a check on the estimation scheme and pointed to further work to improve the determination of OAM using this method. A significant effort was also devoted to quantifying effects of uncertainties in high frequency winds on the mean and seasonal momentum exchange between atmosphere and oceans.

Salstein, David A.↗

Microstructure-sensitive mechanical behavior of an additively manufactured psuedoelastic shape memory alloy

The additive manufacturing of shape memory alloys into complex geometries enables fabrication of advanced functional systems across a variety of fields and domains. This work presents results focused on the mechanical behavior of additively manufactured shape memory pseudoelastic NiTi. The deformation induced solid state phase transformation from austenite to martensite allows this system to accommodate large recoverable strains. This deformation behavior is fundamentally driven by crystal-scale transformation physics. Laser powder bed fusion processing reveals that the resulting microstructure, both grain morphology and crystallographic texture, is strongly dependent on the manufacturing processing history. Exhaustive mechanical testing demonstrates that these microstructural factors strongly impact both tensile and cyclic stress–strain behavior. Cyclic dissipative behavior, however, is similar across all tested microstructures following an initial transient period. Remarkably, analysis of spatial strain fields during tensile loading reveals two distinctly different localization “modes”. The first is initiation of localized deformation bands which continuously propagate through the tensile bar during loading. In the second mode localization is observed but lacks propagation; instead additional localization cites nucleate during subsequent loading. The latter phenomena is suspected to be driven by grain-scale deformation physics as the localized band morphologies coincide with grain morphologies. These phenomena strongly impact the resulting aggregate stress–strain behavior. Hence, manufacturers and designers of psuedoelastic functional components must at the very least consider the potential variability in properties when considering additive manufacturing processing. More ideally the process–structure–property relations can be used to further tailor and optimize final functional performance.

Additive manufacturing↗

Wildfire Risk Evaluation Framework for Grid Operations and Planning

The United States (US) environmental protection agency's (EPA's) climate change indicators for wildfires show a long-term trend of increased annual wildfire activity, larger wildfire size, and more variable dynamics in wildfire behavior. This has caused more frequent preemptive public safety power shutoff (PSPS) events in the regions with recognized high wildfire risk. These preemptive power shutoffs attempt to prevent the ignition of a wildfire but it nonetheless renders the transmission line non-operational, which often sheds load of downstream communities. As wildfires and PSPS events become more frequent, it is crucial to find the communities most at risk of load shedding. To that end, this paper proposes the wildfire risk evaluation of the system (WiRES) framework, which is a performance-based framework that translates extreme weather-related and PSPS event probabilities into a cumulative probability of a non-operational transmission line. This study also provides a geospatial visualization tool that breaks down the entire western electrical coordinating council (WECC) region into 50 km grid cells which can be used to 1) filter out transmission lines with higher than a threshold outage probability, and 2) graphically discover the affected regions and their biophysical and socioeconomic metrics. %such as the social vulnerability index, population density, gross domestic product, etc. Lastly, an impact assessment study is conducted which connects the results of the proposed framework to python and powerworld-based contingency analysis to highlight the applicability of the framework.

Wildfire, Resilience, Extreme Events, Grid Reslien↗

Employing Fracture Statistics to Track Cell Reliability Through Module Fabrication

In this work we demonstrate how fracture statistics may be employed to track cell reliability through module fabrication steps. We were able to detect how cell cutting equipment could reduce cell fracture strain by 25 % as well as increase its variability. A smaller reduction was found to result from the ribbon soldering operation, and all cells measured were weaker when strained in an orientation perpendicular to the gridlines. Cell fracture measurements were found to be consistent with the number of cracked cells experienced in full sized modules exposed to mechanical loading. A structural mechanics model was created to elucidate how the requisite fracture strain is developed in a cell encapsulated within a PV module and demonstrates that this strain decreases more than 50 % from its center to edge when placed within the inner loading span of four-point flexure. The associated implications on the apparent cell strength is examined with an effective volume treatment.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Practical low-temperature gasoline combustion for very high efficiency off-road, medium- and heavy-duty engines

Low-temperature gasoline combustion (LTGC) with additive-mixing fuel injection (AMFI) is a new combustion strategy that has been demonstrated to deliver 9%–25% better brake thermal efficiency than similar-sized market-leading diesel engines over the operating map. Moreover, the LTGC-AMFI engine shows near-zero smoke, and NOx emissions are 4–100 times lower than those of a diesel, sufficiently low that no aftertreatment, or only passive NOx aftertreatment, would be sufficient (diesel exhaust fluid is not required). LTGC-AMFI combustion is based on kinetically controlled compression ignition of a dilute charge with a variable amount of low-to-moderate fuel stratification. Fast combustion control is provided by adding minute amounts of an ignition-enhancing additive into the fuel each engine cycle to control its reactivity. This strategy was used to operate a medium-duty (MD) LTGC-AMFI engine at loads from idle to 16.3 bar BMEP and speeds from 600 to 2400 rpm with regular E10 gasoline, which covers nearly the entire operating map of a typical MD engine. Turbine-out temperatures were sufficient for an oxidation catalyst to control hydrocarbon and CO emissions. Autonomie simulations over the GEM ARB Transient and the GEM 55 mph Cruise driving cycles for class-6 trucks using this technology showed fuel economies of 8.1 and 11.4 mpg-gasoline-equivalent, respectively, corresponding to 18.6% and 13.4% improvements over a similar-size diesel engine. Engine-out NOx emissions were 0.024 and 0.01 g/bhp-h, respectively, well below current U.S. emission standards. These results show that switching from diesel to LTGC-AMFI engines would greatly reduce greenhouse gas (GHG) emissions for off-road, MD and HD applications, which will continue to rely on combustion engines because electrification is not practical in the foreseeable future. Finally, with their reduced fuel consumption, the lower cost of gasoline compared to diesel fuel, and much lower aftertreatment costs, LTGC-AMFI engines also offer a significantly lower total cost of ownership.

33 ADVANCED PROPULSION SYSTEMS↗

Review of the Agard S&M panel evaluation program of the NASA-Lewis 'SRP' approach to high-temperature LCF life prediction

Twenty laboratories in six countries participated in this program, each testing its own materials of interest under its own laboratory conditions. In this way the results obtained provided validation of the Strainrange Partitioning (SRP) method for a wide range of materials and insured maximum usefulness to each of the participating laboratories. The first, very necessary step in the evaluation of any life prediction approach - assessing the ability of the method to predict life of simple laboratory specimens subjected to complex loading, was thereby taken. The culmination of this program was the Specialists Meeting that was held in Aalborg, Denmark in April of 1978. At that meeting the various investigators shared their findings, thus providing the basis for an in-depth evaluation of the SRP method. While the results were variable from laboratory to laboratory, most investigators agreed that the SRP method was a significant step toward life prediction in the presence of high temperature and cyclic stresses.

Hirschberg, M. H.↗

A mathematical simulation model of the CH-47B helicopter, volume 2

A nonlinear simulation model of the CH-47B helicopter, was adapted for use in a simulation facility. The model represents the specific configuration of the variable stability CH-47B helicopter. Modeling of the helicopter uses a total force approach in six rigid body degrees of freedom. Rotor dynamics are simulated using the Wheatley-Bailey equations, steady state flapping dynamics and included in the model of the option for simulation of external suspension, slung load equations of motion. Validation of the model was accomplished by static and dynamic data from the original Boeing Vertol mathematical model and flight test data. The model is appropriate for use in real time piloted simulation and is implemented on the ARC Sigma IX computer where it may be operated with a digital cycle time of 0.03 sec.

Weber, J. M.↗

Analysis of the Variable Pressure Growth Chamber using the CASE/A simulation package

A computer simulation of the Variable Pressure Growth Chamber (VPGC), located at the NASA Johnson Space Center, has been developed using the Computer Aided Systems Engineering and Analysis (CASE/A) package. The model has been used to perform several analyses of the VPGC. The analyses consisted of a study of the effects of a human metabolic load on the VPGC and a study of two new configurations for the temperature and humidity control (THC) subsystem in the VPGC. The objective of the human load analysis was to study the effects of a human metabolic load on the air revitalization and THC subsystems. This included the effects on the quantity of carbon dioxide injected and oxygen removed from the chamber and the effects of the additional sensible and latent heat loads. The objective of the configuration analysis was to compare the two new THC configurations against the current THC configuration to determine which had the best performance.

Mcfadden, Carl D.↗

Design for cyclic loading endurance of composites

The application of the computer code IPACS (Integrated Probabilistic Assessment of Composite Structures) to aircraft wing type structures is described. The code performs a complete probabilistic analysis for composites taking into account the uncertainties in geometry, boundary conditions, material properties, laminate lay-ups, and loads. Results of the analysis are presented in terms of cumulative distribution functions (CDF) and probability density function (PDF) of the fatigue life of a wing type composite structure under different hygrothermal environments subjected to the random pressure. The sensitivity of the fatigue life to a number of critical structural/material variables is also computed from the analysis.

Shiao, Michael C.↗

Experimental Verification of a Progressive Damage Model for IM7/5260 Laminates Subjected to Tension-Tension Fatigue

The durability and damage tolerance of laminated composites are critical design considerations for airframe composite structures. Therefore, the ability to model damage initiation and growth and predict the life of laminated composites is necessary to achieve structurally efficient and economical designs. The purpose of this research is to experimentally verify the application of a continuum damage model to predict progressive damage development in a toughened material system. Damage due to monotonic and tension-tension fatigue was documented for IM7/5260 graphite/bismaleimide laminates. Crack density and delamination surface area were used to calculate matrix cracking and delamination internal state variables to predict stiffness loss in unnotched laminates. A damage dependent finite element code predicted the stiffness loss for notched laminates with good agreement to experimental data. It was concluded that the continuum damage model can adequately predict matrix damage progression in notched and unnotched laminates as a function of loading history and laminate stacking sequence.

Coats, Timothy W.↗

Noncontacting Laser Inspection System for Dimensional Profiling of Space Application Thermal Barriers

A noncontacting, two-dimensional (2-D) laser inspection system has been designed and implemented to dimensionally profile thermal barriers being developed for space vehicle applications. In a vehicle as-installed state, thermal barriers are commonly compressed between load sensitive thermal protection system (TPS) panels to prevent hot gas ingestion through the panel interface during flight. Loads required to compress the thermal barriers are functions of their construction, as well as their dimensional characteristics relative to the gaps in which they are installed. Excessive loads during a mission could damage surrounding TPS panels and have catastrophic consequences. As such, accurate dimensional profiling of thermal barriers prior to use is important. Due to the compliant nature of the thermal barriers, traditional contact measurement techniques (e.g., calipers and micrometers) are subjective and introduce significant error and variability into collected dimensional data. Implementation of a laser inspection system significantly enhanced the method by which thermal barriers are dimensionally profiled, and improved the accuracy and repeatability of collected data. A statistical design of experiments study comparing laser inspection and manual caliper measurement techniques verified these findings.

Taylor, Shawn C.↗

Air Launch: Examining Performance Potential of Various Configurations and Growth Options

The Advanced Concepts Office at NASA's George C. Marshall Space Flight Center conducted a high-level analysis of various air launch vehicle configurations, objectively determining maximum launch vehicle payload while considering carrier aircraft capabilities and given dimensional constraints. With the renewed interest in aerial launch of low-earth orbit payloads, referenced by programs such as Stratolaunch and Spaceship2, there existed a need to qualify the boundaries of the trade space, identify performance envelopes, and understand advantages and limiting factors of designing for maximum payload capability. Using the NASA/DARPA Horizontal Launch Study (HLS) Point Design 2 (PD-2) as a point-of-departure configuration, two independent design actions were undertaken. Both configurations utilized a Boeing 747-400F as the carrier aircraft, LOX/RP-1 first stage and LOX/LH2 second stage. Each design was sized to meet dimensional and mass constraints while optimizing propellant loads and stage delta V (ΔV) splits. All concepts, when fully loaded, exceeded the allowable Gross Takeoff Weight (GTOW) of the aircraft platform. This excess mass was evaluated as propellant/fuel offload available for a potential in-flight refueling scenario. Results indicate many advantages such as large, relative payload delivery of approximately 47,000 lbm and significant mission flexibility, such as variable launch site inclination and launch window; however, in-flight cryogenic fluid transfer and carrier aircraft platform integration are substantial technical hurdles to the realization of such a system configuration.

Waters, Eric D.↗

Improved Prediction of Losses with Large Eddy Simulation in a Low-Pressure Turbine

There is a need to improve predictions of losses resulting from large eddy simulations (LES) of low-pressure turbines (LPT) in gas turbines. This may be done by assessing the accuracy of predictions against validation data and understanding the source of any inaccuracies. LES is a promising approach for capturing the laminar/turbulent transition process in a LPT. In previous studies, the authors utilized LES to model the flow field over a Variable Speed Power Turbine (VSPT) blade and successfully captured characteristic features of separation/reattachment and transition on the suction side at both the cruise (positive incidence) and take-off conditions (negative incidence) and as well, simulated the effect of free-stream turbulence (FST) on those phenomena. The predicted pressure loading profiles agreed well with the experimental data for both a high and a low FST case at a Reynolds number of Re(ex)=220,000. In this paper, we present wake profiles resulting from computations for a range of FST values. Although the predicted wake profiles for the lowest FST case (Tu=0.5%) matched the experimental data, at higher FST (Tu=10-15%,) the wake was wider than the experimentally measured wake and for both cases were displaced laterally when compared to the experimental measurements. In our investigation of the causes of the said discrepancies we have identified important effects which could strongly influence the predicted wake profile. Predicted losses were improved by assuring the validity of the flow solution. This was done by utilizing spectral analysis to scrutinize the dynamic behavior of the wake and determine solution accuracy resulting from low mesh density and low accuracy of convective modeling.

LES-LDKM↗

Employing Fracture Statistics to Track Cell Reliability Through Module Fabrication

In this work we demonstrate how fracture statistics may be employed to track cell reliability through module fabrication steps. We were able to detect how cell cutting equipment could reduce cell fracture strain by 25 % as well as increase its variability. A smaller reduction was found to result from the ribbon soldering operation, and all cells measured were weaker when strained in an orientation perpendicular to the gridlines. Cell fracture measurements were found to be consistent with the number of cracked cells experienced in full sized modules exposed to mechanical loading. A structural mechanics model was created to elucidate how the requisite fracture strain is developed in a cell encapsulated within a PV module and demonstrates that this strain decreases more than 50 % from its center to edge when placed within the inner loading span of four-point flexure. The associated implications on the apparent cell strength is examined with an effective volume treatment.

14 SOLAR ENERGY↗