Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “total scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Shielding and Build-up Considerations for Radiation Detection

Abstract -- Shielding for gamma radiation has traditionally focused on the reduction of dose effects. For these applications, reducing the energy of the radiation is important along with reducing the actual number of photons, and therefore large masses of high Z material are typically used. However, for measurements requiring low backgrounds or for detecting low activity signals, such as in homeland security applications, the primary use of shielding is to decrease the total number of background photons (perhaps in a region of interest), and therefore the processes of buildup and down scattering become important. In these applications, where the important measure is count rate instead of dose and low background are important, improved reduction in counts from background radiation may be achieved with specially designed configurations of thin layers of different materials instead of a single thick layer. This paper briefly describes recent modeling and experimental investigations in layered-shielding methodology and provides results with comparison to single shielding material such as Pb. Application of these techniques to some real world problems, such as detector systems for homeland security, is discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The ionic conductivity of Sm‐doped ceria

Abstract The oxygen ion conductivity of polycrystalline samples of Sm‐doped ceria and of Gd‐doped ceria is studied as a function of doping fraction and temperature using impedance spectroscopy allowing the separation of bulk and grain boundary conductivity. The introduction of a fine spacing for the Sm dopant fraction allows the clear identification of the dopant fraction leading to the largest bulk conductivity. At 267°C, the largest bulk conductivity is shown for Ce 0.93 Sm 0.07 O 1.965 . With increasing temperature, indications of an increase in the dopant fraction, which leads to the maximum in conductivity, are found. For the grain boundary conductivity, the maximum appears at larger dopant fractions compared to the bulk conductivity. The largest total conductivity for both dopants is again found for Sm‐doped ceria. In literature, different syntheses and sample preparation methods led to larger total conductivities for Gd‐doped ceria. In this work, we demonstrate that the variation of sintering conditions leads to scattering in the conductivity over one order of magnitude. Finally, we demonstrate that, in nominally pure cerium oxide, impurities dominate the ionic conductivity.

Koettgen, Julius↗

SU-G-IeP4-12: Performance of In-111 Coincident Gamma-Ray Counting: A Monte Carlo Simulation

Purpose: The decay of In-111 results in a non-isotropic gamma-ray cascade, which is normally imaged using a gamma camera. Creating images with a gamma camera using coincident gamma-rays from In-111 has not been previously studied. Our objective was to explore the feasibility of imaging this cascade as coincidence events and to determine the optimal timing resolution and source activity using Monte Carlo simulations. Methods: GEANT4 was used to simulate the decay of the In-111 nucleus and to model the gamma camera. Each photon emission was assigned a timestamp, and the time delay and angular separation for the second gamma-ray in the cascade was consistent with the known intermediate state half-life of 85ns. The gamma-rays are transported through a model of a Siemens dual head Symbia “S” gamma camera with a 5/8-inch thick crystal and medium energy collimators. A true coincident event was defined as a single 171keV gamma-ray followed by a single 245keV gamma-ray within a specified time window (or vice versa). Several source activities (ranging from 10uCi to 5mCi) with and without incorporation of background counts were then simulated. Each simulation was analyzed using varying time windows to assess random events. The noise equivalent count rate (NECR) was computed based on the number of true and random counts for each combination of activity and time window. No scatter events were assumed since sources were simulated in air. Results: As expected, increasing the timing window increased the total number of observed coincidences albeit at the expense of true coincidences. A timing window range of 200–500ns maximizes the NECR at clinically-used source activities. The background rate did not significantly alter the maximum NECR. Conclusion: This work suggests coincident measurements of In-111 gamma-ray decay can be performed with commercial gamma cameras at clinically-relevant activities. Work is ongoing to assess useful clinical applications.

60 APPLIED LIFE SCIENCES↗

Proton Spin Puzzle and Confinement of Quarks

It is shown that the confinement effect that is significant at great distances from the nucleon center is capable of inducing the appreciable quark helicity flip. A simultaneous change in projections of the orbital angular momentum of quarks on the direction of their motion, which follows from the Dirac equation, ensures the conservation of the total angular momentum of the system. Thus, a part of the proton spin, measured in experiments with deep inelastic scattering of leptons, may be hidden in the orbital angular momentum of quarks.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiative transfer in spherical shell atmospheres. I - Rayleigh scattering

The plane-parallel approximation and the more realistic spherical shell approximation for the radiance reflected from a planetary atmosphere are compared and are applied to the study of a planet the size of the earth with a homogeneous conservative Rayleigh scattering atmosphere extending to a height of 100 km. Inadequacies of the approximations are considered. Radiance versus height distributions for both single and multiple scattering are presented, as are results for the fractional radiance from altitudes in the atmosphere which contribute to the total unidirectional reflected radiance at the top of the atmosphere. The data can be used for remote sensing applications and planetary spectroscopy.

Adams, C. N.↗

Shuttle/payload contamination evaluation /SPACE/ program improvements

Performance features, analytic details, and applications of the SPACE computer code for simulating the contaminant environment experienced by Shuttle payloads on-orbit are outlined. A summary is presented of the model preset, input, and output parameters, capabilities, and analytical options. The program was designed to identify the molecular column density, molecular deposition in various scenarios, and the background brightness produced by the contaminant clouds. SPACE covers payload geometries such as the Orbiter and four Spacelab modules, configurations tracing and summing the production of contamination from distributed leakage sources or concentrated sources. A total of ten chemical species can be analyzed, with consideration given to line-of-sight mass transport or scattered molecule transport. Deposition levels can be computed, as can reflection evaluation. Trial results for the analyses of three different payloads are presented. Additionally, the Mini-SPACE code, for quick-look analyses during the payload planning analyses, is outlined.

Jarossy, F. J.↗

Radiative equilibrium model of Titan's atmosphere

The present global radiative equilibrium model for the Saturn satellite Titan is restricted to the two-stream approximation, is vertically homogeneous in its scattering properties, and is spectrally divided into one thermal and two solar channels. Between 13 and 33% of the total incident solar radiation is absorbed at the planetary surface, and the 30-60 ratio of violet to thermal IR absorption cross sections in the stratosphere leads to the large temperature inversion observed there. The spectrally integrated mass absorption coefficient at thermal wavelengths is approximately constant throughout the stratosphere, and approximately linear with pressure in the troposphere, implying the presence of a uniformly mixed aerosol in the stratosphere. There also appear to be two regions of enhanced opacity near 30 and 500 mbar.

Samuelson, R. E.↗

Sudden Radiative Braking in Colliding Hot-Star Winds

When two hot-star winds collide, their interaction centers at the point where the momentum fluxes balance. However, in WR+O systems, the imbalance in the corporeal momentum fluxes may be extreme enough to preclude a standard head-on wind/wind collision. On the other hand, an important component of the total momentum flux in radiatively driven winds is carried by photons. Thus, if the wind interaction region has sufficient scattering opacity, it can reflect stellar photons and cause important radiative terms to enter the momentum balance. This radiative input would result in additional braking of the wind. We use a radiative-hydrodynamics calculation to show that such radiative braking can be an important effect in many types of colliding hot-star winds. Characterized by sudden deceleration of the stronger wind in the vicinity of the weak-wind star, it can allow a wind ram balance that would otherwise be impossible in many WR+O systems with separations less than a few hundred solar radii. It also greatly weakens the shock strength and the encumbent X ray production. We demonstrate the significant features of this effect using V444 Cygni as a characteristic example. We also derive a general analytic theory that applies to a wide class of binaries, yielding simple predictions for when radiative braking should play an important role.

Gayley, K. G.↗

Simultaneous X-ray and Far-Ultraviolet Spectra of AGN with ASCA and HUT

We obtained ASCA spectra of the Seyfert 1 galaxy NGC 3516 in March 1995. Simultaneous far-UV observations were obtained with the Hopkins Ultraviolet Telescope on the Astro-2 shuttle mission. The ASCA spectrum shows a lightly absorbed power law of energy index 0.78. The low energy absorbing column is significantly less than previously seen. Prominent 0 VII and 0 VIII absorption edges are visible, but, consistent with the much lower total absorbing column, no Fe K absorption edge is detectable. A weak, narrow Fe K(alpha) emission line from cold material is present as well as a broad Fe K(alpha) line. These features are similar to those reported in other Seyfert 1 galaxies. A single warm absorber model provides only an imperfect description of the low energy absorption. In addition to a highly ionized absorber with ionization parameter U = 1.66 and a total column density of 1.4 x 10(exp 22)/sq cm, adding a lower ionization absorber with U = 0.32 and a total column of 6.9 x 10(exp 21)/sq cm significantly improves the fit. The contribution of resonant line scattering to our warm absorber models limits the Doppler parameter to less than 160 km/s at 90% confidence. Turbulence at the sound speed of the photoionized gas provides the best fit. None of the warm absorber models fit to the X-ray spectrum can match the observed equivalent widths of all the UV absorption lines. Accounting for the X-ray and UV absorption simultaneously requires an absorbing region with a broad range of ionization parameters and column densities.

Kriss, Gerard A.↗

PCA/HEXTE Observations of Coma and A2319

The Coma cluster was observed in 1996 for 90 ks by the PCA and HEXTE instruments aboard the RXTE satellite, the first simultaneous, pointing measurement of Coma in the broad, 2-250 keV, energy band. The high sensitivity achieved during this long observation allows precise determination of the spectrum. Our analysis of the measurements clearly indicates that in addition to the main thermal emission from hot intracluster gas at kT=7.5 keV, a second spectral component is required to best-fit the data. If thermal, it can be described with a temperature of 4.7 keV contributing about 20% of the total flux. The additional spectral component can also be described by a power-law, possibly due to Compton scattering of relativistic electrons by the CMB. This interpretation is based on the diffuse radio synchrotron emission, which has a spectral index of 2.34, within the range allowed by fits to the RXTE spectral data. A Compton origin of the measured nonthermal component would imply that the volume-averaged magnetic field in the central region of Coma is B =0.2 micro-Gauss, a value deduced directly from the radio and X-ray measurements (and thus free of the usual assumption of energy equipartition). Barring the presence of unknown systematic errors in the RXTE source or background measurements, our spectral analysis yields considerable evidence for Compton X-ray emission in the Coma cluster.

Rephaeli, Yoel↗

Transition Region Emission and the Energy Input to Thermal Plasma in Solar Flares

Understanding the energetics of solar flares depends on obtaining reliable determinations of the energy input to flare plasma. X-ray observations of the thermal bremsstrahlung from hot flare plasma provide temperatures and emission measures which, along with estimates of the plasma volume, allow the energy content of this hot plasma to be computed. However, if thermal energy losses are significant or if significant energy goes directly into cooler plasma, this is only a lower limit on the total energy injected into thermal plasma during the flare. We use SOHO UVCS observations of O VI flare emission scattered by coronal O VI ions to deduce the flare emission at transition region temperatures between 100,000 K and 1 MK for the 2002 July 23 and other flares. We find that the radiated energy at these temperatures significantly increases the deduced energy input to the thermal plasma, but by an amount that is less than the uncertainty in the computed energies. Comparisons of computed thermal and nonthermal electron energies deduced from RHESSI, GOES, and UVCS are shown.

Holman, Gordon D.↗

Dose reduction of scattered photons from concrete walls lined with lead: Implications for improvement in design of megavoltage radiation therapy facility mazes

Purpose: This study explores the possibility of using lead to cover part of the radiation therapy facility maze walls in order to absorb low energy photons and reduce the total dose at the maze entrance of radiation therapy rooms. Methods: Experiments and Monte Carlo simulations were utilized to establish the possibility of using high-Z materials to cover the concrete walls of the maze in order to reduce the dose of the scattered photons at the maze entrance. The dose of the backscattered photons from a concrete wall was measured for various scattering angles. The dose was also calculated by the FLUKA and EGSnrc Monte Carlo codes. The FLUKA code was also used to simulate an existing radiotherapy room to study the effect of multiple scattering when adding lead to cover the concrete walls of the maze. Monoenergetic photons were used to represent the main components of the x ray spectrum up to 10 MV. Results: It was observed that when the concrete wall was covered with just 2 mm of lead, the measured dose rate at all backscattering angles was reduced by 20% for photons of energy comparable to Co-60 emissions and 70% for Cs-137 emissions. The simulations with FLUKA and EGS showed that the reduction in the dose was potentially even higher when lead was added. One explanation for the reduction is the increased absorption of backscattered photons due to the photoelectric interaction in lead. The results also showed that adding 2 mm lead to the concrete walls and floor of the maze reduced the dose at the maze entrance by up to 90%. Conclusions: This novel proposal of covering part or the entire maze walls with a few millimeters of lead would have a direct implication for the design of radiation therapy facilities and would assist in upgrading the design of some mazes, especially those in facilities with limited space where the maze length cannot be extended to sufficiently reduce the dose.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of the integrated Luminosities of cross-section scan data samples around the ${\rm{\psi }}$(3770) mass region

To investigate the nature of the (3770) resonance and to measure the cross section for e + e - →D$\bar{D}$, a cross-section scan data sample, distributed among 41 center-of-mass energy points from 3.73 to 3.89 GeV, was taken with the BESIII detector operated at the BEPCII collider in the year 2010. By analyzing the large angle Bhabha scattering events, we measure the integrated luminosity of the data sample at each center-of-mass energy point. The total integrated luminosity of the data sample is 76.16±0.04±0.61 pb -1 , where the first uncertainty is statistical and the second systematic.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetic field amplification in nonlinear diffusive shock acceleration including resonant and non-resonant cosmic-ray driven instabilities

We present a nonlinear Monte Carlo model of efficient diffusive shock acceleration where the magnetic turbulence responsible for particle diffusion is calculated self-consistently from the resonant cosmic-ray (CR) streaming instability, together with non-resonant short- and long-wavelength CR-current-driven instabilities. We include the backpressure from CRs interacting with the strongly amplified magnetic turbulence which decelerates and heats the super-Alfvénic flow in the extended shock precursor. Uniquely, in our plane-parallel, steady-state, multi-scale model, the full range of particles, from thermal (∼eV) injected at the viscous subshock to the escape of the highest energy CRs (∼PeV) from the shock precursor, are calculated consistently with the shock structure, precursor heating, magnetic field amplification, and scattering center drift relative to the background plasma. In addition, we show how the cascade of turbulence to shorter wavelengths influences the total shock compression, the downstream proton temperature, the magnetic fluctuation spectra, and accelerated particle spectra. A parameter survey is included where we vary shock parameters, the mode of magnetic turbulence generation, and turbulence cascading. From our survey results, we obtain scaling relations for the maximum particle momentum and amplified magnetic field as functions of shock speed, ambient density, and shock size.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum trajectories in complex space: One-dimensional stationary scattering problems

One-dimensional time-independent scattering problems are investigated in the framework of the quantum Hamilton-Jacobi formalism. The equation for the local approximate quantum trajectories near the stagnation point of the quantum momentum function is derived, and the first derivative of the quantum momentum function is related to the local structure of quantum trajectories. Exact complex quantum trajectories are determined for two examples by numerically integrating the equations of motion. For the soft potential step, some particles penetrate into the nonclassical region, and then turn back to the reflection region. For the barrier scattering problem, quantum trajectories may spiral into the attractors or from the repellers in the barrier region. Although the classical potentials extended to complex space show different pole structures for each problem, the quantum potentials present the same second-order pole structure in the reflection region. This paper not only analyzes complex quantum trajectories and the total potentials for these examples but also demonstrates general properties and similar structures of the complex quantum trajectories and the quantum potentials for one-dimensional time-independent scattering problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of deuterium clusters mixed with helium gas for an application in beam-target-fusion experiments

We measured the average deuterium cluster size within a mixture of deuterium clusters and helium gas by detecting Rayleigh scattering signals. The average cluster size from the gas mixture was comparable to that from a pure deuterium gas when the total backing pressure and temperature of the gas mixture were the same as those of the pure deuterium gas. According to these measurements, the average size of deuterium clusters depends on the total pressure and not the partial pressure of deuterium in the gas mixture. To characterize the cluster source size further, a Faraday cup was used to measure the average kinetic energy of the ions resulting from Coulomb explosion of deuterium clusters upon irradiation by an intense ultrashort pulse. The deuterium ions indeed acquired a similar amount of energy from the mixture target, corroborating our measurements of the average cluster size. As the addition of helium atoms did not reduce the resulting ion kinetic energies, the reported results confirm the utility of using a known cluster source for beam-target-fusion experiments by introducing a secondary target gas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Raising the quantum efficiency of AlGaInN flip-chip LEDs by Reactive ion etching of the outer side of SiC substrates

A method for creating a light-scattering microprofile on the outer side of SiC substrates in order to diminish the light extraction loss caused by the effect of total internal reflection in light-emitting AlGaIn/GaN structures has been further developed. It is suggested to use thin photoresist layers as random masks for reactive ion etching of silicon carbide substrates. A microprofile with the required parameters has been obtained on the substrate surface by optimizing the etching modes, with the result that the external quantum efficiency of light-emitting crystals increased by more than 25%.

36 MATERIALS SCIENCE↗

First results from the Thomson scattering diagnostic on proto-MPEX

A Thomson scattering (TS) diagnostic has been successfully implemented on the prototype Material Plasma Exposure eXperiment (Proto-MPEX) at Oak Ridge National Laboratory. The diagnostic collects the light scattered by plasma electrons and spectroscopically resolves the Doppler shift imparted to the light by the velocity of the electrons. The spread in velocities is proportional to the electron temperature, while the total number of photons is proportional to the electron density. TS is a technique used on many devices to measure the electron temperature (T{sub e}) and electron density (n{sub e}) of the plasma. A challenging aspect of the technique is to discriminate the small number of Thomson scattered photons against the large peak of background photons from the high-power laser used to probe the plasma. A variety of methods are used to mitigate the background photons in Proto-MPEX, including Brewster angled windows, viewing dumps, and light baffles. With these methods, first results were measured from argon plasmas in Proto-MPEX, indicating T{sub e} ∼ 2 eV and n{sub e} ∼ 1 × 10{sup 19} m{sup −3}. The configuration of the Proto-MPEX TS diagnostic will be described and plans for improvement will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗