Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Multicoordination Control Strategy Performance in Hybrid Power Systems

This paper evaluates a state-space methodology of a multi-input multi-output (MIMO) control strategy using a 2 × 2 tightly coupled scenario applied to a physical gas turbine fuel cell hybrid power system. A centralized MIMO controller was preferred compared to a decentralized control approach because previous simulation studies showed that the coupling effect identified during the simultaneous control of the turbine speed and cathode airflow was better minimized. The MIMO controller was developed using a state-space dynamic model of the system that was derived using first-order transfer functions empirically obtained through experimental tests. The controller performance was evaluated in terms of disturbance rejection through perturbations in the gas turbine operation, and setpoint tracking maneuver through turbine speed and cathode airflow steps. The experimental results illustrate that a multicoordination control strategy was able to mitigate the coupling of each actuator to each output during the simultaneous control of the system, and improved the overall system performance during transient conditions. On the other hand, the controller showed different performance during validation in simulation environment compared to validation in the physical facility, which will require a better dynamic modeling of the system for the implementation of future multivariable control strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Online Diagnosis of Performance Variation in HPC Systems Using Machine Learning

As the size and complexity of HPC systems grow in line with advancements in hardware and software technology, HPC systems increasingly suffer from performance variation due to shared resource contention as well as software- and hardware-related problems. Such performance variations can lead to failures and inefficiencies, and are among the main challenges in system resiliency. To minimize the impact of performance variation, one must quickly and accurately detect and diagnose the anomalies that cause the variation and take mitigating actions. However, it is difficult to identify anomalies based on the voluminous, high-dimensional, and noisy data collected by system monitoring infrastructures. This paper presents a novel machine learning based framework to automatically diagnose performance anomalies at runtime. Our framework leverages historical resource usage data to extract signatures of previously-observed anomalies. We first convert the collected time series data into easy-to-compute statistical features. We then identify the features that are required to detect anomalies, and extract the signatures of these anomalies. At runtime, we use these signatures to diagnose anomalies with negligible overhead. Here, we evaluate our framework using experiments on a real-world HPC supercomputer and demonstrate that our approach successfully identifies 98% of injected anomalies and consistently outperforms existing anomaly diagnosis techniques.

97 MATHEMATICS AND COMPUTING↗

Thermal Performance of Exterior Insulation and Finish Systems Containing Vacuum Insulation Panels

A high-performance wall system is under development to improve wall thermal performance to a level of U-factor of 0.19 W/(m2 K) (R-30 [h ft2 F]/Btu) in a standard wall thickness by incorporating vacuum insulation panels (VIPs) into an exterior insulation finish system (EIFS). Such a system would be applicable to new construction and will offer a solution to more challenging retrofit situations as well. Multiple design options were considered to balance the need to protect theVIPs during construction and building operation, while minimizing heat transfer through the wall system. The results reported here encompass an indepth assessment of potential system performances including thermal modeling, detailed laboratory measurements under controlled conditions on the component, and system levels according to ASTM C518 (ASTM 2010). The results demonstrate the importance of maximizing the VIP coverage over the wall face. The results also reveal the impact of both the design and execution of system details, such as the joints between adjacent VIPs. The test results include an explicit modeled evaluation of the system performance in a clear wall.

Childs, Kenneth W↗

Energy Performance Testing of Asetek's RackCDU System at NREL's High Performance Computing Data Center

In this study, we report on the first tests of Asetek's RackCDU direct-to-chip liquid cooling system for servers at NREL's ESIF data center. The system was simple to install on the existing servers and integrated directly into the data center's existing hydronics system. The focus of this study was to explore the total cooling energy savings and potential for waste-heat recovery of this warm-water liquid cooling system. RackCDU captured up to 64% of server heat into the liquid stream at an outlet temperature of 89 degrees F, and 48% at outlet temperatures approaching 100 degrees F. This system was designed to capture heat from the CPUs only, indicating a potential for increased heat capture if memory cooling was included. Reduced temperatures inside the servers caused all fans to reduce power to the lowest possible BIOS setting, indicating further energy savings potential if additional fan control is included. Preliminary studies manually reducing fan speed (and even removing fans) validated this potential savings but could not be optimized for these working servers. The Asetek direct-to-chip liquid cooling system has been in operation with users for 16 months with no necessary maintenance and no leaks.

97 MATHEMATICS AND COMPUTING↗

Detailed Modeling, Design, and Evaluation of a Scalable Multi-level Checkpointing System

High-performance computing (HPC) systems are growing more powerful by utilizing more hardware components. As the system mean-time-before-failure correspondingly drops, applications must checkpoint more frequently to make progress. However, as the system memory sizes grow faster than the bandwidth to the parallel file system, the cost of checkpointing begins to dominate application run times. A potential solution to this problem is to use multi-level checkpointing, which employs multiple types of checkpoints with different costs and different levels of resiliency in a single run. The goal is to design light-weight checkpoints to handle the most common failure modes and rely on more expensive checkpoints for less common, but more severe failures. While this approach is theoretically promising, it has not been fully evaluated in a large-scale, production system context. To this end we have designed a system, called the Scalable Checkpoint/Restart (SCR) library, that writes checkpoints to storage on the compute nodes utilizing RAM, Flash, or disk, in addition to the parallel file system. We present the performance and reliability properties of SCR as well as a probabilistic Markov model that predicts its performance on current and future systems. We show that multi-level checkpointing improves efficiency on existing large-scale systems and that this benefit increases as the system size grows. In particular, we developed low-cost checkpoint schemes that are 100x-1000x faster than the parallel file system and effective against 85% of our system failures. This leads to a gain in machine efficiency of up to 35%, and it reduces the the load on the parallel file system by a factor of two on current and future systems.

99 GENERAL AND MISCELLANEOUS↗

Wide-area, real-time monitoring and visualization system

A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

47 OTHER INSTRUMENTATION↗

Wide-area, real-time monitoring and visualization system

A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Moisture Performance of High-R Wall Systems

High-performance homes offer improved comfort, lower utility bills, and assured durability. The next generation of building enclosures is a key step toward achieving high-performance goals through decreasing energy load demand and enabling advanced space-conditioning systems. Yet the adoption of high-R enclosures and particularly high-R walls has been a slow-growing trend because mainstream builders are hesitant to make the transition. In a survey of builders on this topic, one of the challenges identified is an industry-wide concern about the long-term moisture performance of energy-efficient walls. This study takes a step toward addressing this concern through direct monitoring of the moisture performance of high-R walls in occupied homes in several climate zones. In addition, the robustness of the design and modeling tools for selecting high-R wall solutions is evaluated using the monitored data from the field. The information and knowledge gained through this research will provide an objective basis for decision-making so that builders can implement advanced designs with confidence.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moisture Performance of High-R Wall Systems

High-performance homes offer improved comfort, lower utility bills, and assured durability. The next generation of building enclosures is a key step toward achieving high-performance goals through decreasing energy load demand and enabling advanced space-conditioning systems. Yet the adoption of high-R enclosures and particularly high-R walls has been a slow-growing trend because mainstream builders are hesitant to make the transition. In a survey of builders on this topic, one of the challenges identifi ed is an industry-wide concern about the long-term moisture performance of energy-effi cient walls. This study takes a step toward addressing this concern through direct monitoring of the moisture performance of high-R walls in occupied homes in several climate zones. In addition, the robustness of the design and modeling tools for selecting high-R wall solutions is evaluated using the monitored data from the field. The information and knowledge gained through this research will provide an objective basis for decision-making so that builders can implement advanced designs with confidence.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fail-Slow at Scale: Evidence of Hardware Performance Faults in Large Production Systems

Fail-slow hardware is an under-studied failure mode. We present a study of 114 reports of fail-slow hardware incidents, collected from large-scale cluster deployments in 14 institutions. We show that all hardware types such as disk, SSD, CPU, memory, and network components can exhibit performance faults. We made several important observations such as faults convert from one form to another, the cascading root causes and impacts can be long, and fail-slow faults can have varying symptoms. From this study, we make suggestions to vendors, operators, and systems designers.

fail-slow↗

Cooling performance of direct expansion system using multiple stages and adjustable heat exchange areas for fresh air handling

Providing fresh air to rooms can ensure indoor air quality. The direct expansion fresh air handling units are widely used, and most of them are single-stage treatment units, which are less energy-efficient under variable operating conditions. To overcome the shortcomings of existing systems, a direct expansion system using multiple stages and adjustable heat exchange areas for fresh air handling is proposed in this study. The fresh air is handled by coils stage by stage to achieve high efficiency, and the dampers of the idle coils are opened when some of the coils are working, which results in the performance improvement under partial load conditions. The simulation model is established, and operating conditions at load ratio of 95.70%, 45.38%, 31.76% and 0 are selected as typical operating conditions. The proposed system performances under different conditions are compared with traditional system. The results show that: (1) For four conditions, as the load rate decreases, the proposed system can save energy by 6.2%, 26.1%, 46.5%, and 25.0% compared to the traditional system respectively; (2) The proposed system can bypass the filter when the outdoor air is good, which can further save energy by 1.3%, 1.8%, 3.4%, and 25.9% under four conditions, respectively.

Zha, Fuhai↗

A Pulsar-Inspired Timing Framework for Power System: Optimization and Performance Evaluation

Due to their excellent stability, neutron pulsar stars are considered promising candidate timing sources for power system applications. However, the complexity of pulsar signals necessitates advanced processing algorithms to provide accurate timing references. This paper presents the foundational framework for pulsar signal processing, serving as the basis for further optimization. To enhance the timing accuracy and computation efficiency in pulsar period searches, three algorithms are proposed as the initial optimization step: wavelet de-noising, fast folding, and cross-correlation for profile evaluation. Wavelet de-noising improves signal-to-noise ratio (SNR) by 36%–70%. Fast folding reduces computation time from hundreds of seconds to mere milliseconds. Cross-correlation works better than traditional SNR-based methods by effectively identifying the optimal period. The performance of the proposed algorithms is evaluated using observation data from telescopes. Together, these algorithms significantly improve pulsar timing performance, reducing the error of the Pulse Per Second (PPS) signal from hundreds to tens of microseconds.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗

Computerized operator support system and human performance in the control room - 262

An operator aid technology to assist nuclear plant operators maintain situation awareness and detect faults earlier than would be possible using conventional control room technologies is described. Coined the Computerized Operator Support System (COSS), this technology is aimed at the human-machine interface. The COSS has been implemented as a prototype system operating in the control room environment of a full-scale simulator for a commercial nuclear power plant. A human factors assessment that involved two licensed reactor crews was performed to evaluate crew performance. This paper describes the development of the COSS, the underlying fault-detection architecture, and feedback received based on operator-in-the-loop studies. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance of the Ultra-High Rate Germanium (UHRGe) System

This report describes the final performance achieved with the detector system developed for the Ultra High Rate Germanium (UHRGe) project. The system performance has been evaluated at low, moderate and high rates and includes the performance of real-time analysis algorithms running in the FPGA of the data acquisition system. This performance is compared to that of offline analyses of streaming waveform data collected with the same data acquisition system the performance of a commercial Multi-Channel Analyzer designed for high-resolution spectroscopy applications, the Canberra LYNX.

47 OTHER INSTRUMENTATION↗

Investigation of the effects of passive pre-chamber nozzle pattern and ignition system on engine performance and emissions

The impact of passive pre-chamber (PC) internal volume, nozzle hole pattern (i.e. with and without a central axial nozzle), and PC igniter plug type on performance and emissions was investigated in an optically accessible, single-cylinder, gasoline research engine. The two PC igniter plugs investigated were a conventional inductive coil spark plug and a nanosecond repetitively pulsed (NRP) plasma discharge system previously demonstrated to accelerate early flame propagation. The baseline PC design featured a funnel shaped internal volume with a PC tip that contained six radial nozzles and a larger central axial nozzle. Two additional PC tip geometries were evaluated where either the baseline internal volume was increased or the axial nozzle was removed and the radial nozzle diameters were increased. A sweep of charge equivalence ratios ( ϕ) from nearly stoichiometric to the lean limit was performed for a fixed engine speed (1300 revolutions per minute), and engine load (3.5 bar gross indicated mean effective pressure). Time-resolved PC and main chamber (MC) pressure data as well as MC emissions data were collected to analyze engine performance and emissions characteristics. Combustion in the MC was further investigated using high-speed excited methylidyne radical (CH*) chemiluminescence imaging. Collected results highlighted that while all PC tips and ignition systems exhibited similar performance and emissions down to ϕ = 0.8, relevant differences in thermal efficiency and emissions for leaner charge mixtures were observed, with the results highly dependent on the nozzle pattern and ignition system. Major deviations were correlated to preferential de-pressurization of the PC through the axial nozzle for lean conditions that was not observed for mixture conditions closer to stoichiometric. Results show that a combination of radial and axial nozzle patterns in the PC extended lean-stability limits at the low-load condition evaluated. Further benefits were observed with the use of NRP ignition systems due to faster combustion within the PC volume provided that the volume was sufficiently large.

Di Sabatino, Francesco↗

Enhancing the Performance of Assisted Execution Runtime Systems through Hardware/Software Techniques

To meet the expected performance, future exascale systems will require programmers to increase the level of parallelism of their applications. Novel programming models simplify parallel programming at the cost of increasing runtime overheard. Assisted execution models have the potential of reducing this overhead but they generally also reduce processor utilization. We propose an integrated hardware/software solution that automatically partition hardware resources between application and auxiliary threads. Each system level performs well-defined tasks efficiently: 1) the runtime system is enriched with a mechanism that automatically detects computing power requirements of running threads and drives the hardware actuators; 2) the hardware enforces dynamic resource partitioning; 3) the operating system provides an efficient interface between the runtime system and the hardware resource allocation mechanism. As a test case, we apply this adaptive approach to STM2, an software transactional memory system that implements the assisted execution model. We evaluate the proposed adaptive solution on an IBMPOWER7 system using Eigenbench and STAMP benchmark suite. Results show that our approach performs equal or better than the original STM2 and achieves up to 65% and 86% performance improvement for Eigenbench and STAMP applications, respectively.

Kestor, Gokcen↗

Determining System Parameters for Optimal Performance of Hybrid DS/FFH Spread-Spectrum

In recent years there has been great interest in using hybrid spread-spectrum (HSS) techniques for commercial applications, particularly in the Smart Grid, in addition to their use in military communications because they accommodate high data rates with high link integrity, even in the presence of significant multipath effects and interfering signals. A highly useful form of this transmission technique for many types of command, control, and sensing applications is the specific code-related combination of standard direct sequence (DS) modulation with "fast" frequency hopping (FFH), denoted hybrid DS/FFH, wherein multiple frequency hops occur within a single data-bit time. In this paper, an optimization problem is formulated that maximizes the DS/FFH communication system performance in terms of probability of bit error and solves for the system design parameters. The objective function is non-convex and can be solved by applying the Karush-Kuhn-Tucker conditions. System design parameters of interest are the length of the DS code sequence, number of frequency hopping channels, number of channels corrupted by wide-band jamming, and number of hops per bit. The proposed formulation takes into account the effects from wide-band and partial-band jamming, multi-user interference and/or varying degrees of Rayleigh and Rician multipath fading. Numerical results are presented to demonstrate the method s viability.

direct sequence↗