Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stream operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Demonstration of Plasma Arc Environmental Technology Applications for the Demilitarization of DOD Stockpiles

Since 1989 the U.S. Army Construction Engineering Research Laboratories (USACERL) have been active participants in the research and development toward establishing Plasma Arc Technology (PAT) as an efficient, economical, and safe hazardous waste immobilization tool. A plasma torch capable of generating high temperatures makes this technology a viable and powerful tool for the thermal destruction of various military industrial waste streams into an innocuous ceramic material no longer requiring hazardous waste landfill (Class 1) disposal. The emerging pl asma environmental thermal treatment process, has been used to safely and efficiently meet the waste disposal needs for various demilitarized components disposal needs, such as: pyrotechnic smoke assemblies, thermal batteries, proximity fuses, cartridge actuated devices (CAD's), and propellant actuated devices (PAD's). MSE Technology Applications, Inc., (MSE) has proposed and fabricated a Mobile Plasma Treatment System to be a technology demonstrator for pilot-scale mobile plasma waste processing. The system is capable of providing small-scale waste remediation services, and conducting waste stream applicability demonstrations. The Mobile Plasma Treatment System's innovative concept provides the flexibility to treat waste streams at numerous sites and sites with only a limited quantity of waste, yet too hazardous to transport to a regional fixed facility. The system was designed to be operated as skid mounted modules; consisting of a furnace module, controls module, offgas module, and ancillary systems module. All system components have been integrated to be operated from a single control station with both semi-continuous feeding and batch slag-pouring capability.

Smith, Ed↗

Small Scale Trace Contaminant Testing of SA9T at Ambient and Reduced Pressure Conditions

A principle concern for air revitalization technology in a closed loop system is the capability to control carbon dioxide (CO2) and humidity (H2O). An amine based sorbent technology, SA9T, has long been evaluated for use in this application and several programs are evaluating it for use in both a cabin as well as space suit applications. While the CO2 and H2O performance of the sorbent has been tested extensively, the question of how trace contaminants impact performance requires further evaluation. This paper presents experimental results of small scale SA9T testing that was performed over a variety of test conditions and with a variety of trace contaminants. Testing evaluated the ability of SA9T media to sufficiently remove CO2 and H2O after exposure to a fully saturated trace contaminant at ambient conditions. Testing also evaluated the impact of CO2 and H2O removal performance at suit loop pressures during cyclic operation with a constant inlet contaminant load. In addition, testing evaluated the performance of SA9T at ambient conditions in a continuous 30-day test with a mixed trace contaminant stream.

Broerman, Craig↗

Automated Behavior Analysis of Malware: A Case Study of WannaCry Ransomware

Ransomware, a class of self-propagating malware that uses encryption to hold the victims’ data ransom, has emerged in recent years as one of the most dangerous cyber threats, with widespread damage; e.g., zero-day ransomware WannaCry has caused world-wide catastrophe, from knocking U.K. National Health Service hospitals offline to shutting down a Honda Motor Company in Japan [1]. Our close collaboration with security operations of large enterprises reveals that defense against ransomware relies on tedious analysis from high-volume systems logs of the first few infections. Sandbox analysis of freshly captured malware is also commonplace in operation. We introduce a method to identify and rank the most discriminating ransomware features from a set of ambient (non-attack) system logs and at least one log stream containing both ambient and ransomware behavior. These ranked features reveal a set of malware actions that are produced automatically from system logs, and can help automate tedious manual analysis. We test our approach using WannaCry and two polymorphic samples by producing logs with Cuckoo Sandbox during both ambient, and ambient plus ransomware executions. Our goal is to extract the features of the malware from the logs with only knowledge that malware was present. We compare outputs with a detailed analysis of WannaCry allowing validation of the algorithm’s feature extraction and provide analysis of the method’s robustness to variations of input data—changing quality/quantity of ambient data and testing polymorphic ransomware. Most notably, our patterns are accurate and unwavering when generated from polymorphic WannaCry copies, on which 63 (of 63 tested) antivirus (AV) products fail.

Chen, Qian↗

Data Analysis Approach for Large Data Volumes in a Connected Community

Recent advancements within smart neighborhoods where utilities are enabling automatic control of appliances such as heating, ventilation, and air conditioning (HVAC) and water heater (WH) systems are providing new opportunities to minimize energy costs through reduced peak load. This requires systematic collection, storage, management, and in-memory processing of large volumes of streaming data for fast performance. In this paper, we propose a multi-tier layered IoT software framework that enables effective descriptive and predictive data analysis for understanding live operation of the neighborhood, fault identification, and future opportunities for further optimization of load curves. We then demonstrate how we achieve live situational awareness of the connected neighborhood through a suite of visualization components. Finally, we discuss a few analytic dashboards that address questions such as peak load reductions obtained due to optimization, customer preference for automatic control of appliances (do they override the automatic control of HVAC?, etc.). 1 1 This manuscript has been authored by UT-Battelle, LLC under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a nonexclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes. The Department of Energy will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (http://energy.gov/downloads/doe-public-access-plan).

Chinthavali, Supriya↗

High-Resolution Characterization of Comingled Contaminants in the Deep Vadose Zone, Hanford Site, Washington - 17387

The contaminated deep vadose zone in the Central Plateau of the Hanford Site in Washington state presents a unique challenge to remediation. The Comprehensive Environmental Response, Compensation, and Liability Act, commonly known as the CERCLA project responsible for addressing these deep contaminants is designated as the 200-Deep Vadose Zone Operable Unit (DV-1 project). The vadose zone is 55-82 meters (180-270 feet) thick and is contaminated with both radiological and chemical contaminants from multiple historical waste streams. The mobile contaminants from this waste are still present in the deep vadose zone and pose a potential threat to the groundwater. Characterizing the nature and extent of the comingled mobile contaminants is an important step before assessing possible remedial alternatives. One factor controlling the migration and distribution of subsurface contaminants is the lithologic heterogeneity of the vadose zone sediments. A sampling plan for the DV-1 project includes continuous sediment core collection and analysis to identify key lithologic factors (i.e., small-scale bedding and structural features) that act as barriers, preferential pathways or conduits for mobile contaminants migrating through the vadose zone. Over six hundred meters (2,000 feet) of intact sediment core from 26 boreholes were collected in 1.5 meters (5 feet) long, 10 centimeter (4-inch) diameter segments. These intact sediment samples provide significant improvement in the level of detail and understanding of mechanisms and features controlling contaminant distribution that is not possible with traditional homogenized drill cuttings or conventional split-spoon samples. Detailed geological descriptions and photographs of the intact core are correlated to high-resolution geophysical logs which aid in the development of a comprehensive contaminant distribution profile of the borehole. These lithologic interpretations are used to define specific depth intervals for sampling based on changes in moisture, lithology, and elevated gamma radiation. The selected samples are analyzed for contaminants of concern, geochemical parameters, and hydraulic properties. Significant lithologic features observed in the intact cores include sharp contact boundaries to graded bedding, iron-oxide and carbonate cementation, silty laminations, clastic dike intrusions, and soft sediment deformation. Preliminary geologic logs integrated with the sample analysis indicate features that correlate to the variable distribution of contaminants both laterally and vertically. Integration of measured hydraulic parameters to lithologic units in individual borehole profiles provide key inputs for more precise geo-framework and vadose zone flux models supporting the DV-1 project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radioactive Test Platform Demonstrating the Direct Feed Low-Activity Waste Process at Hanford - 18628

The Hanford Site is implementing a phased process for treating liquid legacy radioactive waste. The process is called the Direct Feed Low-Activity Waste process (DFLAW). The DFLAW includes a filtration and ion-exchange unit in the Low-Activity Waste Pretreatment System (LAWPS) that removes solids and cesium. This pretreat feed is then sent to a vitrification facility where glass-forming solids are added and the waste is turned into glass in a melter. The melter off-gas liquid condensate is evaporated in the Effluent Management Facility (EMF), with the concentrate recycled back into the feed. A laboratory-scale test platform has been built to test various aspects of the DFLAW process using samples of actual radioactive waste. The current platform represents four of the major unit operations: filtration, ion-exchange, vitrification, and off-gas condensation. A lab scale EMF is being designed to supplement the current platform. The platform is expandable to add any or all unit operations. The radioactive test platform has three missions. The first is simply to demonstrate the DFLAW process with real waste. A second objective is to address flowsheet gaps and opportunities, some of which require testing with real waste. Some gaps and opportunities include addressing the fate of mercury in the flowsheet, evaluating salt and aluminum precipitation, and proving new glass formulations with real waste. A third objective of the radioactive test platform is to demonstrate or evaluate future operations and alternative flowsheets. Some of the future operations evaluated will be the life expectancy of the resin in real waste, resin sampling, evaluation of how waste affects melter throughput, and grouting various primary and secondary waste streams. The radioactive test platform is therefore a crucial tool for verifying and optimizing the DFLAW flowsheet at Hanford with real waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Collective Memory Transfers for Multi-Core Chips

Future performance improvements for microprocessors have shifted from clock frequency scaling towards increases in on-chip parallelism. Performance improvements for a wide variety of parallel applications require domain-decomposition of data arrays from a contiguous arrangement in memory to a tiled layout for on-chip L1 data caches and scratchpads. How- ever, DRAM performance suffers under the non-streaming access patterns generated by many independent cores. We propose collective memory scheduling (CMS) that actively takes control of collective memory transfers such that requests arrive in a sequential and predictable fashion to the memory controller. CMS uses the hierarchically tiled arrays formal- ism to compactly express collective operations, which greatly improves programmability over conventional prefetch or list- DMA approaches. CMS reduces application execution time by up to 32% and DRAM read power by 2.2×, compared to a baseline DMA architecture such as STI Cell.

97 MATHEMATICS AND COMPUTING↗

Tracking and data relay satellite system (TDRSS) - A worldwide view from space

The development, performance levels, and operational use of the TDRSS satellite system are outlined. The TDRSS spacecraft were conceived in the mid-1960s by NASA as a means of using GEO-positioned satellites to eliminate existing ground stations. The main ground terminal becomes Goddard Space Flight Center, through which users other than the Shuttle can also gain access. The TDRSS functions as a relay vehicle, with very little on-board processing except for status reports inserted into the data stream. Use of the TDRSS system by nonNASA agencies currently costs $110/min for forwards, return, and tracking, $24/min for forward service alone, and $8/min for return service only. The spacecraft can store data on board and dump it to the ground station during the limited hours of operation.

Macoughtry, W. O.↗

Sensing Electrical Networks Securely & Economically (SENSE)

The growing adoption of distributed energy resources (DERs) like battery energy storage systems and roof top solar/PV and the rapid penetration of electric vehicles (EVs), the electric grid is undergoing a major transformation with elevated stress on legacy grid assets. Despite a lot of expenditure to address these challenges, both in dollars and manpower, utilities have not been able to receive the value that was promised. The gains have been most visible at the transmission and substation level, especially where the main objective was improving operational and economic efficiency for the utility. Improving visibility and control at a few select points enhances the existing and established paradigm of centralized command and control. With changing load patterns, load types and the overall transition to an “active grid”, the centralized control and coordination paradigm gets challenged. To address the challenges, a new architecture and mechanism is needed, one that supports decentralized control and decision making, extracting value streams at the grid edge, particularly as the changes are fueled by transitions occurring in the distribution system. To address this, a communications and data processing platform, “GAMMA” was developed and demonstrated through the project. At the heart of the platform, are distributed, intelligent edge nodes with sensing and compute capabilities, that can record and analyze information locally. They are embedded in sensors and actuators specific to different distribution system applications. Phase 1 of the project focused on developing novel sensor technology that can be used for monitoring utility pole top distribution transformers. The sensors were designed with the objective of being low-cost, communicating with the GAMMA cloud using novel “delay-tolerant” networking using Bluetooth and a secure mobile application. They were non-intrusive in nature so that they can be installed quickly in the field, resulting in overall low cost of deployment and operations. Following the successful completion of Phase 1, the team manufactured 100 units for a field demonstration in Phase 2. The field demonstration was carried out on two real feeder systems with the local utility partner. In total, 100 sensors were installed and operated over a period of 6 months in the state of Georgia. The platform is operational end to end, with the cloud infrastructure deployed on a distributed, serverless environment that can serve multiple data streams, an analytics engine and a portal to securely view the data from multiple assets. The data collected through the GAMMA Mobile Phone app showcased the viability of the novel delay tolerant networking architecture, and the data processing algorithms developed through the course of the project, were successful in extracting important information about the overall network, improving the utility’s visibility and situational awareness in the distribution feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Small-Scale Spray Releases: Initial Aerosol Test Results

One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and net generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of antifoam agents was assessed with most of the simulants. Orifices included round holes and rectangular slots. For the combination of both test stands, the round holes ranged in size from 0.2 to 4.46 mm. The slots ranged from (width × length) 0.3 × 5 to 2.74 × 76.2 mm. Most slots were oriented longitudinally along the pipe, but some were oriented circumferentially. In addition, a limited number of multi-hole test pieces were tested in an attempt to assess the impact of a more complex breach. Much of the testing was conducted at pressures of 200 and 380 psi, but some tests were conducted at 100 psi. Testing the largest postulated breaches was deemed impractical because of the much larger flow rates and equipment that would be required. This report presents the experimental results and analyses for the aerosol measurements obtained in the small-scale test stand. It includes a description of the simulants used and their properties, equipment and operations, data analysis methodologies, and test results. The results of tests investigating the role of slurry particles in plugging small breaches are reported in Mahoney et al. (2012). The results of the aerosol measurements in the large-scale test stand are reported in Schonewill et al. (2012) along with an analysis of the combined results from both test scales.

Mahoney, Lenna A.↗

Electrocatalytic Valorization into H2 and Hydrocarbons of an Aqueous Stream Derived from Hydrothermal Liquefaction

Electrocatalytic oxidation is an attractive process for valorizing the carbon and removal of nitrogen present in the aqueous waste streams at ambient conditions. Here, we evaluated the electrocatalytic oxidation as a function of applied potential over a commercial Pt electrode of aqueous waste stream generated via hydrothermal liquefaction. We validated the conversion of quantifiable carbon (e.g., carboxylic acids, alpha hydroxyacids, alcohols, ketones, amides) and unquantifiable carbon as well as nitrogen removal. The unquantifiable carbon was valorized to quantifiable short chain organic molecules (e.g., acetic). Model studies showed that carboxylic acids, alcohol and ketones converted following (non-) Kolbe chemistry. Amides and alpha hydroxyacids formed carboxylic acids that subsequently converted via (non-) Kolbe chemistry. Ammonia was oxidized into N2. The reaction rate varied for each molecule family with carboxylic acids and ammonia having the highest reaction rates. The main reaction products from the electrocatalytic oxidation at the anode were volatile, short chain hydrocarbons (i.e., olefins, paraffins) and CO generated via Kolbe chemistry, while H2 was generated at the cathode. The parallel denitrification, valorization of carbon, and H2 generation of the aqueous waste can replace and simplify the current unit operations used in a commercial hydrothermal liquefaction process. The high operation potential required to drive the electrocatalytic reaction is responsible for high operation costs; however, they can be either partially subsidized with sale of excess H2 at the current DOE goal of $2/kg H2. Thus, the present work shows how electrocatalytic oxidation can be used to valorize aqueous waste streams into volatile hydrocarbons and H2.

Electrocatalytic oxidation, Aqueous waste valoriza↗

Geochemical Modeling of F Area Seepage Basin Composition and Variability

From the 1950s through 1989, the F Area Seepage Basins at the Savannah River Site (SRS) received low level radioactive wastes resulting from processing nuclear materials. Discharges of process wastes to the F Area Seepage Basins followed by subsequent mixing processes within the basins and eventual infiltration into the subsurface resulted in contamination of the underlying vadose zone and downgradient groundwater. For simulating contaminant behavior and subsurface transport, a quantitative understanding of the interrelated discharge-mixing-infiltration system along with the resulting chemistry of fluids entering the subsurface is needed. An example of this need emerged as the F Area Seepage Basins was selected as a key case study demonstration site for the Advanced Simulation Capability for Environmental Management (ASCEM) Program. This modeling evaluation explored the importance of the wide variability in bulk wastewater chemistry as it propagated through the basins. The results are intended to generally improve and refine the conceptualization of infiltration of chemical wastes from seepage basins receiving variable waste streams and to specifically support the ASCEM case study model for the F Area Seepage Basins. Specific goals of this work included: (1) develop a technically-based 'charge-balanced' nominal source term chemistry for water infiltrating into the subsurface during basin operations, (2) estimate the nature of short term and long term variability in infiltrating water to support scenario development for uncertainty quantification (i.e., UQ analysis), (3) identify key geochemical factors that control overall basin water chemistry and the projected variability/stability, and (4) link wastewater chemistry to the subsurface based on monitoring well data. Results from this study provide data and understanding that can be used in further modeling efforts of the F Area groundwater plume. As identified in this study, key geochemical factors affecting basin chemistry and variability included: (1) the nature or chemistry of the waste streams, (2) the open system of the basins, and (3) duration of discharge of the waste stream types. Mixing models of the archetype waste streams indicated that the overall basin system would likely remain acidic much of the time. Only an extended periods of predominantly alkaline waste discharge (e.g., >70% alkaline waste) would dramatically alter the average pH of wastewater entering the basins. Short term and long term variability were evaluated by performing multiple stepwise modeling runs to calculate the oscillation of bulk chemistry in the basins in response to short term variations in waste stream chemistry. Short term (1/2 month and 1 month) oscillations in the waste stream types only affected the chemistry in Basin 1; little variation was observed in Basin 2 and 3. As the largest basin, Basin 3 is considered the primary source to the groundwater. Modeling showed that the fluctuation in chemistry of the waste streams is not directly representative of the source term to the groundwater (i.e. Basin 3). The sequence of receiving basins and the large volume of water in Basin 3 'smooth' or nullify the short term variability in waste stream composition. As part of this study, a technically-based 'charge-balanced' nominal source term chemistry was developed for Basin 3 for a narrow range of pH (2.7 to 3.4). An example is also provided of how these data could be used to quantify uncertainty over the long term variations in waste stream chemistry and hence, Basin 3 chemistry.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sandia National Laboratories support of the Iraq Nuclear Facility Dismantlement and Disposal Program.

Because of past military operations, lack of upkeep and looting there are now enormous radioactive waste problems in Iraq. These waste problems include destroyed nuclear facilities, uncharacterized radioactive wastes, liquid radioactive waste in underground tanks, wastes related to the production of yellow cake, sealed radioactive sources, activated metals and contaminated metals that must be constantly guarded. Iraq currently lacks the trained personnel, regulatory and physical infrastructure to safely and securely manage these facilities and wastes. In 2005 the International Atomic Energy Agency (IAEA) agreed to organize an international cooperative program to assist Iraq with these issues. Soon after, the Iraq Nuclear Facility Dismantlement and Disposal Program (the NDs Program) was initiated by the U.S. Department of State (DOS) to support the IAEA and assist the Government of Iraq (GOI) in eliminating the threats from poorly controlled radioactive materials. The Iraq NDs Program is providing support for the IAEA plus training, consultation and limited equipment to the GOI. The GOI owns the problems and will be responsible for implementation of the Iraq NDs Program. Sandia National Laboratories (Sandia) is a part of the DOS's team implementing the Iraq NDs Program. This report documents Sandia's support of the Iraq NDs Program, which has developed into three principal work streams: (1) training and technical consultation; (2) introducing Iraqis to modern decommissioning and waste management practices; and (3) supporting the IAEA, as they assist the GOI. Examples of each of these work streams include: (1) presentation of a three-day training workshop on 'Practical Concepts for Safe Disposal of Low-Level Radioactive Waste in Arid Settings;' (2) leading GOI representatives on a tour of two operating low level radioactive waste disposal facilities in the U.S.; and (3) supporting the IAEA's Technical Meeting with the GOI from April 21-25, 2008. As noted in the report, there was significant teaming between the various participants to best help the GOI. On-the-ground progress is the focus of the Iraq NDs Program and much of the work is a transfer of technical and practical skills and knowledge that Sandia uses day-to-day. On-the-ground progress was achieved in July of 2008 when the GOI began the physical cleanup and dismantlement of the Active Metallurgical Testing Laboratory (LAMA) facility at Al Tuwaitha, near Baghdad.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Increased capabilities of the Langley Mach 7 Scramjet Test Facility

An experimental research program which explored the potential for expanding the operating range of NASA Langley's Mach 7 Scramjet Test Facility is described. The facility uses electric arc-heated air as the test gas and is configured for testing airframe-integrated scramjet engine models at conditions duplicating flight velocities and temperatures. Previous scramjet testing in this facility was limited to a single simulated flight condition of Mach 6.9 at 115,300 ft. altitude. The present arc heater research demonstrated that the facility can be used for scramjet testing at simulated flight conditions from Mach 4 (at altitudes from 77,000 to 114,000 ft.) to Mach 7 (at altitudes from 108,000 to 149,000 ft.). Flow quality was established from the uniformity of measured total temperature profiles. In addition, nitrogen oxide levels in the test stream were determined for relating engine test data to expected flight performance. The test frequency and reliability of the facility were also improved by a novel redesign of the heater downstream electrode and by defining limits for stable arc operation.

Thomas, S. R.↗

Use of Ionic Liquids as Physical Solvents for Selective Capture of CO2 from Fuel Gas Streams

This study is to investigate the potential use of ionic liquids (ILs) as physical solvents for selective CO2 capture from post water-gas-shift reactor streams at elevated pressures and temperatures. The equilibrium gas solubility (x*) and the volumetric mass transfer coefficients (kLa) for CO2 and H2 in two different ILs (TEGO IL K5 and TEGO IL P51P) were determined. The data were obtained in an agitated reactor, equipped with sight-windows, in wide ranges of pressures, temperatures, mixing speeds, and liquid heights. Under the operating conditions investigated, the CO2 solubilities in the two ILs increased with pressure at constant temperature and decreased with temperature at constant pressure. Also, the volumetric liquid-side mass transfer coefficients of CO2 increased with mixing speed, pressure, and temperature and decreased with liquid height. The CO2 solubilities in the TEGO IL K5 were greater than those in the other two ILs at 500 K. Under similar operating conditions, the CO2 solubilities in the two ILs were greater than those of H2, which reflects the selective nature of ILs for CO2 capture. In addition, the ILs appeared to have negligible vapor pressure up to 500 K, which presents an advantage over conventional physical solvents currently employed for CO2 capture from post water-gas-shift reactor streams. This study demonstrated the thermal stability of the ILs and highlighted their ability to selectively capture CO2 at temperatures up to 500 K and pressures as high as 30 bars.

08 HYDROGEN↗

Characterization of a dimer preparation method for nanoscale organic aerosol

Nanoscale dimers have application in studies of aerosol physicochemical properties such as aerosol viscosity. These particle dimers can be synthesized using the dual tandem differential mobility analyzer (DTDMA) technique, wherein oppositely charged particle streams coagulate to form dimers that can be isolated using electrostatic filtration. Although some characterization of the technique has been published, a detailed thesis on the modes and theory of operation has remained outside the scope of prior work. In this paper we present new experimental data characterizing the output DTDMA size distribution and the physical processes underlying its apparent modes. Key experimental limitations for both general applications and for viscosity measurements are identified and quantified in six distinct types of DTDMA experiments. The primary consideration is the production of an adequate number of dimers, which typically requires high mobility-selected number concentration in the range 25,000-100,000 cm -3 . The requisite concentration threshold depends upon the rate of spontaneous monomer decharging, which arises predominately from interactions of the aerosol with ionizing radiation within the coagulation chamber and is instrument location dependent. Lead shielding of the coagulation chamber reduced the first-order decharging constant from ~2.0 x 10 -5 s -1 to ~0.8 x 10 -5 s -1 in our laboratory. Dimer production at monomer diameters less than 40 nm is hindered by low bipolar charging efficiency. Results from the characterization experiments shed light on design considerations for general applications and for characterization of viscous aerosol phase transitions.

54 ENVIRONMENTAL SCIENCES↗

Performance of a CO 2 sorbent for indoor air cleaning applications: Effects of environmental conditions, sorbent aging, and adsorption of co-occurring formaldehyde

Indoor air cleaning systems that incorporate CO 2 sorbent materials enable HVAC load shifting and efficiency improvements. This study developed a bench-scale experimental system to evaluate the performance of a sorbent under controlled operation conditions. A thermostatic holder containing 3.15 g sorbent was connected to a manifold that delivered CO 2 -enriched air at a known temperature and relative humidity (RH). The air stream was also enriched with 0.8-2.1 ppm formaldehyde. The CO 2 concentration was monitored in real-time upstream and downstream of the sorbent, and integrated formaldehyde samples were collected at different times using DNPH-coated silica cartridges. Sorbent regeneration was carried out by circulating clean air in countercurrent. Almost 200 loading/regeneration cycles were performed in the span of 17 months, from which 104 were carried out at reference test conditions defined by loading with air at 25°C, 38% RH, and 1000 ppm CO 2 , and regenerating with air at 80°C, 3% RH and 400 ppm CO 2 . The working capacity decreased slightly from 43-44 mg CO 2 per g sorbent to 39-40 mg per g over the 17 months. The capacity increased with lower loading temperature (in the range 15-35°C) and higher regeneration temperature, between 40 and 80°C. The CO 2 capacity was not sensitive to the moisture content in the range 6-9 g/m 3 , and decreased slightly when dry air was used. Loading isothermal breakthrough curves were fitted to three simple adsorption models, verifying that pseudo-first-order kinetics appropriately describes the adsorption process. The model predicted that equilibrium capacities decreased with increasing temperature from 15 to 35°C, while adsorption rate constants slightly increased. The formaldehyde adsorption efficiency was 80%-99% in different cycles, corresponding to an average capacity of 86 ± 36 µg/g. Formaldehyde was not quantitatively released during regeneration, but its accumulation on the sorbent did not affect CO 2 adsorption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Approach for Configuring a Standardized Vessel for Processing Radioactive Waste Slurries

A standardized vessel design is being considered at the Waste Treatment and Immobilization Plant (WTP) that is under construction at Hanford, Washington. The standardized vessel design will be used for storing, blending, and chemical processing of slurries that exhibit a variable process feed including Newtonian to non-Newtonian rheologies over a range of solids loadings. Developing a standardized vessel is advantageous and reduces the testing required to evaluate the performance of the design. The objectives of this paper are to: 1) present a design strategy for developing a standard vessel mixing system design for the pretreatment portion of the waste treatment plant that must process rheologically and physically challenging process streams, 2) identify performance criteria that the design for the standard vessel must satisfy, 3) present parameters that are to be used for assessing the performance criteria, and 4) describe operation of the selected technology. Vessel design performance will be assessed for both Newtonian and non-Newtonian simulants which represent a range of waste types expected during operation. Desired conditions for the vessel operations are the ability to shear the slurry so that flammable gas does not accumulate within the vessel, that settled solids will be mobilized, that contents can be blended, and that contents can be transferred from the vessel. A strategy is presented for adjusting the vessel configuration to ensure that all these conditions are met.

pulse jet mixing↗