Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “soft”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Thin-Entrance Window Sensors for Soft X-rays at LCLS-II

Free electron lasers, such as SLAC’s LCLS-II, will provide unique scientific imaging opportunities. In order to fully utilize these facilities, we need to develop detectors with shallow entrance windows that will enable detection of soft x-rays from 250eV-1.5KeV. Here, a new microwave annealing technology provides an efficient way to achieve shallow entrance windows in fully depleted high resistivity silicon sensors.

47 OTHER INSTRUMENTATION↗

Use of Transition Models to Design High Performance TESs for the LCLS-II Soft X-Ray Spectrometer

We are designing an array of transition-edge sensor (TES) microcalorimeters for a soft X-ray spectrometer at the Linac Coherent Light Source at SLAC National Accelerator Laboratory to coincide with upgrades to the free electron laser facility. The complete spectrometer will have 1000 TES pixels with energy resolution of 0.5 eV full-width at half-maximum (FWHM) for incident energies below 1 keV while maintaining pulse decay-time constants shorter than 100 μs. In the past, TES pixels have often been designed for a particular scientific application via a combination of simple scaling relations and trial-and-error experimentation with device geometry. We have improved upon this process by using our understanding of transition physics to guide TES design. Using the two-fluid approximation of the phase-slip line model for TES resistance, we observe how the geometry and critical temperature of a TES will affect the shape of the transition. We have used these techniques to design sensors with a critical temperature of 55 mK. The best sensors achieve an energy resolution of 0.75 eV FWHM at 1.25 keV. Building upon this result, we show how the next generation of sensors can be designed to reach our goal of 0.5 eV resolution.

47 OTHER INSTRUMENTATION↗

Material Needs and Measurement Challenges for Advanced Semiconductor Packaging: Understanding the Soft Side of Science

This Perspective builds upon insights from the National Institute of Standards and Technology (NIST)-organized workshop, “Materials and Metrology Needs for Advanced Semiconductor Packaging Strategies,” held at the 35th annual Electronics Packaging Symposium in Binghamton, NY, on September 5, 2024. It outlines critical challenges and opportunities related to polymer-based “soft” materials in advanced semiconductor packaging, with emphasis on polymer science, measurement science (metrology), and the strategic development of Research-Grade Test Materials (RGTMs). These efforts, led by the NIST CHIPS team, aim to advance the fundamental understanding of structure-property-processing relationships, promote standardized guidelines and innovative methods for material characterization, and accelerate the development, qualification, and adoption of next-generation packaging materials. The Perspective also distills key insights from the panel discussion with industry experts, emphasizing the need for close collaboration among materials scientists, process engineers, and metrology experts to enable a holistic strategy, further highlighting the importance of cross-sector partnerships among industry, academia, and government to address pressing challenges in packaging materials and processes.

97 MATHEMATICS AND COMPUTING↗

Effects of Stopping Ions and LET Fluctuations on Soft Error Rate Prediction.

Variability in energy deposition from stopping ions and LET fluctuations is quantified for specific radiation environments. When compared to predictions using average LET via CREME96, LET fluctuations lead to an order-of-magnitude difference in effective flux and a nearly 4x decrease in predicted soft error rate (SER) in an example calculation performed on a commercial 65 nm SRAM. The large LET fluctuations reported here will be even greater for the smaller sensitive volumes that are characteristic of highly scaled technologies. End-of-range effects of stopping ions do not lead to significant inaccuracies in radiation environments with low solar activity unless the sensitivevolume thickness is 100 μm or greater. In contrast, end-of-range effects for stopping ions lead to significant inaccuracies for sensitive- volume thicknesses less than 10 μm in radiation environments with high solar activity.

42 ENGINEERING↗

SiC-Based 5-kV Universal Modular Soft-Switching Solid-State Transformer (M-S4T) for Medium-Voltage DC Microgrids and Distribution Grids

Medium-voltage DC (MVDC) grids are attractive for electric aircraft and ship power systems, battery energy storage system (BESS), fast charging electric vehicle (EV), etc. Such EV or BESS applications need isolated bidirectional MVDC to LVDC or LVAC converters. However, the existing Si-based solutions cannot fulfill the requirements of a high-efficiency and robust converter for MVDC grids. This paper presents a 5 kV SiC-based universal modular solid-state transformer (SST). This universal current-source SST can interface either a LVAC or LVDC grid with a MVDC grid in single-stage power conversion, while the conventional dual active bridge (DAB) converter needs an additional inverter. The proposed SST module using 3.3 kV SiC MOSFETs and diodes is bidirectional and can serve as a building block in series or parallel for higher-voltage higher-power systems. The topology of each module is based on the soft-switching solid-state transformer (S4T) with reduced conduction loss, which features reduced EMI through controlled dv/dt, and high efficiency with full-range ZVS for main devices and ZCS for auxiliary devices. Operation principle of the modular S4T (M-S4T), capacitor voltage balancing control between the cascaded modules, design of components including a medium-voltage (MV) medium-frequency transformer (MFT) to realize a 50 kVA 5 kV DC to 600 V DC or 480 V AC M-S4T are presented. Importantly, the MV MFT prototype achieves very low leakage inductance (0.13%) and 15 kV insulation with coaxial cables and nanocrystalline cores. Here, the proposed universal modular SST is compared against the DAB solution and verified with DC-DC and DC-AC simulation and 4 kV experimental results. Significantly, the MV experimental results of a modular DC transformer with each module at MVDC are rarely covered in the literature and reported for the first time.

14 SOLAR ENERGY↗

A Tri-Port Current-Source Soft-Switching Medium-Voltage String Inverter for Large-Scale Solar-Plus-Storage Farms

This article presents a tri-port current-source soft-switching medium-voltage string inverter (TMVSI) to reduce the Levelized cost of energy (LCOE) of large-scale solar-plus-storage (SPS) farms. Throughout this work, the topology, operating principle, circuit simulation, control, and hardware design of the TMVSI are introduced. In addition, three key challenges compromising the performance of the TMVSI are addressed in this article. First, a new feed-forward compensation for model predictive control of the TMVSI is proposed to compensate for sampling and computational delay and high dc-link ripple with low computational cost and high scalability. Second, the use of laminated permanent magnets is proposed to reduce the losses of the MV medium-frequency transformer (MFT) in the TMVSI while increasing its saturation current. Finally, an improved U-shape winding pattern is proposed to decrease the leakage inductance of the MV MFT and reduce the voltage stress across semiconductor switches without adding cost or complexity. Here, the effectiveness of the TMVSI is validated by experiments at up to 20kW/500V in different test cases with custom-built prototypes. The contributions of this work make the TMVSI a viable solution to SPS farms and unleash its potential for LCOE reduction.

14 SOLAR ENERGY↗

Soft X‐ray Ptychographic Imaging and Morphological Quantification of Calcium Silicate Hydrates (C–S–H)

Morphological details of calcium silicate hydrate (C–S–H) stemming from the hydration process of Portland cement ( PC ) phases are crucial for understanding the PC ‐based systems but are still only partially known. Here we introduce the first soft X‐ray ptychographic imaging of tricalcium silicate (C 3 S) hydration products. The results are compared using both scanning transmission X‐ray and electron transmission microscopy data. The evidence shows that ptychography is a powerful method to visualize the details of outer and inner product C–S–H of fully hydrated C 3 S, which have fibrillar and an interglobular structure with average void sizes of 20 nm, respectively. The high‐resolution ptychrography image enables us to perform morphological quantification of C–S–H, and, for the first time, to possibly distinguish the contributions of inner and outer product C–S–H to the small angle scattering of cement paste. The results indicate that the outer product C–S–H is mainly responsible for the q −3 regime, whereas the inner product C–S–H transitions to a q −2 regime. Various hypotheses are discussed to explain these regimes.

Bae, Sungchul↗

Multilayer on-chip stacked Fresnel zone plates: Hard x-ray fabrication and soft x-ray simulations

Fresnel zone plates are widely used as x-ray nanofocusing optics. To achieve high spatial resolution combined with good focusing efficiency, high aspect ratio nanolithography is required, and one way to achieve that is through multiple e-beam lithography writing steps to achieve on-chip stacking. A two-step writing process producing 50 nm finest zone width at a zone thickness of 1.14 µm for possible hard x-ray applications is shown here. The authors also consider in simulations the case of soft x-ray focusing where the zone thickness might exceed the depth of focus. In this case, the authors compare on-chip stacking with, and without, adjustment of zone positions and show that the offset zones lead to improved focusing efficiency. The simulations were carried out using a multislice propagation method employing Hankel transforms.

Li, Kenan↗

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission↗

In-flight verification of the calibration and performance of the ASTRO-H (Hitomi) Soft X-ray Spectrometer

The Soft X-ray Spectrometer onboard the Astro-H (Hitomi) orbiting x-ray observatory featured an array of 36 silicon thermistor x-ray calorimeters optimized to perform high spectral resolution x-ray imaging spectroscopy of astrophysical sources in the 0.3- to 12-keV band. Extensive preflight calibration measurements are the basis for our modeling of the pulse height–energy relation and energy resolution for each pixel and event grade, telescope collecting area, detector efficiency, and pulse arrival time. Because of the early termination of mission operations, we needed to extract the maximum information from observations performed only days into the mission when the onboard calibration sources had not yet been commissioned and the dewar was still coming into thermal equilibrium, so our technique for reconstructing the per-pixel time-dependent pulse height–energy relation had to be modified. The gain scale was reconstructed using a combination of an absolute energy scale calibration at a single time using a fiducial from an onboard radioactive source and calibration of a dominant time-dependent gain drift component using a dedicated calibration pixel, as well as a residual time-dependent variation using spectra from the Perseus cluster of galaxies. The energy resolution was also measured using the onboard radioactive sources. It is consistent with instrument-level measurements accounting for the modest increase in noise due to spacecraft systems interference. We use observations of two pulsar wind nebulae to validate our models of the telescope area and detector efficiency and to derive a more accurate value for the thickness of the gate-valve Be window, which had not been opened by the time mission operations ceased. We use observations of the Crab nebula to refine the pixel-to-pixel timing and validate the absolute timing.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and performance of Soft Gamma-ray Detector onboard the Hitomi (ASTRO-H) satellite

Hitomi (ASTRO-H) was the sixth Japanese x-ray satellite that carried instruments with exquisite energy resolution of <7 eV and broad energy coverage of 0.3 to 600 keV. The Soft Gamma-ray Detector (SGD) was the Hitomi instrument that observed the highest energy band (60 to 600 keV). The SGD design achieves a low background level by combining active shields and Compton cameras where Compton kinematics is utilized to reject backgrounds coming from outside of the field of view. A compact and highly efficient Compton camera is realized using a combination of silicon and cadmium telluride semiconductor sensors with a good energy resolution. Compton kinematics also carries information for gamma-ray polarization, making the SGD an excellent polarimeter. Following several years of development, the satellite was successfully launched on February 17, 2016. After proper functionality of the SGD components were verified, the nominal observation mode was initiated on March 24, 2016. The SGD observed the Crab Nebula for approximately two hours before the spacecraft ceased to function on March 26, 2016. We present concepts of the SGD design followed by detailed description of the instrument and its performance measured on ground and in orbit.

79 ASTRONOMY AND ASTROPHYSICS↗

Soft x-ray detection for small satellites with a commercial CMOS sensor at room temperature

Recently CMOS (complementary metal-oxide-semiconductor) sensors have progressed to a point where they may offer improved performance in imaging x-ray detection compared to the CCDs often used in x-ray satellites. We demonstrate x-ray detection in the soft x-ray band (250-1700 eV) by a commercially available back-illuminated Sony IMX290LLR CMOS sensor using the Advanced Photon Source at the Argonne National Laboratory. Additionally, while operating the device at room temperature, we measure energy resolutions (FWHM) of 47 eV at 250 eV and and 77 eV 1700 eV which are comparable to the performance of the Chandra ACIS and the Suzaku XIS. Furthermore, we demonstrate that the IMX290LLR can withstand radiation up to 17.1 krad, making it suitable for use on spacecraft in low earth orbit.

47 OTHER INSTRUMENTATION↗

Reconstructing the three-dimensional latent image of extreme ultraviolet resists with resonant soft x-ray scattering

© 2019 Society of Photo-Optical Instrumentation Engineers (SPIE). Extreme ultraviolet (EUV) lithography is one of the most promising printing techniques for high-volume semiconductor manufacturing at the 14-nm half-pitch device node and beyond. However, key challenges around EUV photoresist materials, such as the exposure-dose sensitivity or the line-width roughness, continue to impede its full adoption into industrial nanofab facilities. Metrology tools are required to address these challenges by helping to assess the impact of the EUV materials' properties and processing conditions along different steps of the nanofabrication process. We apply the resonant soft x-ray scattering (RSoXS) technique to gain insights into the structure of patterned EUV resists before the development step takes place. By using energies around the carbon K-edge to take advantage of small differences in chemistry, the electronic density contrast between the exposed and unexposed regions of the resists could be enhanced in order to image the patterns with subnanometer precision. Critical-dimension grazing-incidence small-angle x-ray scattering is then performed at energies where the contrast is maximized, enabling the reconstruction of the three-dimensional shape of the latent image. We demonstrate the potential of RSoXS to provide a high-resolution height-sensitive profile of patterned EUV resists, which will help in quantifying the evolution of critical features, such as the line-edge roughness, at a key step of the nanofabrication process.

Freychet, Guillaume↗

Design and demonstration of tunable soft x-ray lateral shearing and Hartmann wavefront sensors

We describe design guidelines for soft x-ray wavefront sensors and experimentally demonstrate their performance, comparing grating-based lateral shearing interferometry and Hartmann wavefront sensing. We created a compact shearing interferometer concept with a dense array of binary amplitude gratings in a single membrane to support one-dimensional wavefront measurements across a wide wavelength range without the need for longitudinal position adjustment. We find that a common scaling parameter based on wavelength and the distance to the measurement plane guides the design of both systems toward optimal sensitivity. We show preliminary results from recent experiments demonstrating one and two-dimensional wavefront sensing below the Marechal criterion.

Chao, Weilun↗

Using resonant soft x-ray scattering to image patterns on undeveloped resists

Copyright © 2018 SPIE. Extreme ultraviolet lithography is one of the most promising printing techniques for high volume semiconductor manufacturing at the 14 nm half-pitch device node and beyond. However, key challenges around EUV photoresist materials such as the exposure-dose sensitivity or the line-width roughness continue to impede the full adoption into industrial nanofab facilities. New metrology tools are required to address these challenges by helping to determine the impact of the EUV materials' properties and processing conditions on the roughness through the different step of the process. Here, we apply the resonant soft x-ray scattering (RSOXS) technique to gain insights into the structure of patterned EUV resists before the development step takes place. By using energies around the carbon absorption edge to take advantage of small differences in chemistry, the electronic density contrast between the exposed and unexposed regions of the resists could be enhanced in order to image the patterns with sub-nm precision. Critical-dimension grazing incidence small-angle X-ray scattering (CDGISAXS) was then performed at energies where the contrast was maximized, enabling the reconstruction of the 3D shape of the latent image. This demonstrates the potential of RSOXS to provide a high-resolution heightsensitive profile of patterned EUV resists, which will help to quantify the evolution of critical features, such as the line edge roughness, at each step of the nanofabrication process.

Pandolfi, Ronald J↗

Hybrid method simulations of a soft x-ray beamline

A wavefront propagation analysis of a soft X-ray beamline using the HYBRID method is reported. All elements of the beamline: the energy dependence of the insertion device emission, the beamline mirrors and their measured figure errors, the variable-line-spacing grating and its measured figure error, and several exit slit settings, are included in the simulations. The analysis of the propagated undulator radiation through the beamline at two slightly different deflection parameter values demonstrates that, within the beamline angular acceptance and when the monochromator is tuned to the same energy, the flux is higher when the undulator is tuned to slightly higher energy than that of the monochromator. The energy resolution determined from the FWHM of the energy bandwidth transmitted through the exit slit is narrower when the undulator is tuned to higher energy than the monochromator. This is not the case when the resolution is based on the standard deviation of the transmitted energy band. The diffraction effects due to the exit slit size and their consequence on the spot size at the sample position are investigated for a few photon energies.

beamline↗

Soft X-Ray Thomson Scattering in Warm Dense Hydrogen at FLASH

We present collective Thomson scattering with soft x-ray free electron laser radiation as a method to track the evolution of warm dense matter plasmas with {approx}200 fs time resolution. In a pump-probe scheme an 800 nm laser heats a 20 {micro}m hydrogen droplet to the plasma state. After a variable time delay in the order of ps the plasma is probed by an x-ray ultra violet (XUV) pulse which scatters from the target and is recorded spectrally. Alternatively, in a self-Thomson scattering experiment, a single XUV pulse heats the target while a portion of its photons are being scattered probing the target. From such inelastic x-ray scattering spectra free electron temperature and density can be inferred giving insight on relaxation time scales in plasmas as well as the equation of state. We prove the feasibility of this method in the XUV range utilizing the free electron laser facility in Hamburg, FLASH. We recorded Thomson scattering spectra for hydrogen plasma, both in the self-scattering and in the pump-probe mode using optical laser heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accuracy of real time noninvasive temperature measurements using magnetic resonance thermal imaging in patients treated for high grade extremity soft tissue sarcomas

Purpose: To establish accuracy of real time noninvasive temperature measurements using magnetic resonance thermal imaging in patients treated for high grade extremity soft tissue sarcomas. Methods: Protocol patients with advanced extremity sarcomas were treated with external beam radiation therapy and hyperthermia. Invasive temperature measures were compared to noninvasive magnetic resonance thermal imaging (MRTI) at 1.5 T performed during hyperthermia. Volumetric temperature rise images were obtained using the proton resonance frequency shift (PRFS) technique during heating in a 140 MHz miniannular phased array applicator. MRTI temperature changes were compared to invasive measurements of temperature with a multisensor fiber optic probe inside a no. 15 g catheter in the tumor. Since the PRFS technique is sensitive to drifts in the primary imaging magnetic field, temperature change distributions were corrected automatically during treatment using temperature-stable reference materials to characterize field changes in 3D. The authors analyzed MRT images and compared, in evaluable treatments, MR-derived temperatures to invasive temperatures measured in extremity sarcomas. Small regions of interest (ROIs) were specified near each invasive sensor identified on MR images. Temperature changes in the interstitial sensors were compared to the corresponding ROI PRFS-based temperature changes over the entire treatment and over the steady-state period. Nonevaluable treatments (motion/imaging artifacts, noncorrectable drifts) were not included in the analysis. Results: The mean difference between MRTI and interstitial probe measurements was 0.91 deg. C for the entire heating time and 0.85 deg. C for the time at steady state. These values were obtained from both tumor and normal tissue ROIs. When the analysis is done on just the tumor ROIs, the mean difference for the whole power on time was 0.74 deg. C and during the period of steady state was 0.62 deg. C. Conclusions: The data show that for evaluable treatments, excellent correlation ({Delta}T<1 deg. C) of MRTI-ROI and invasive measurements can be achieved, but that motion and other artifacts are still serious challenges that must be overcome in future work.

62 RADIOLOGY AND NUCLEAR MEDICINE↗