Pilot plant testing of elemental mercury reemission from a wet scrubber
This paper is to discuss the recent observations of elemental mercury (Hg{sup 0}) remission from a pilot-scale limestone wet scrubber. Simulated flue gas was generated by burning natural gas in a down-fired furnace and doped with 2000 ppm of sulfur dioxide (SO{sub 2}). Mercuric chloride (HgCl{sub 2}) solution was delivered to the scrubber at a controlled rate to simulate the absorption of ionized mercury (Hg{sup 2+}). Testing results have shown that, after Hg{sup 2+} was injected, elevated Hg{sup 0} concentrations were soon detected both in the scrubber effluent flue gas and the hold tank air, which reflected the occurrence of Hg{sup 0} reemission in both places. When the HgCl{sub 2} feed was stopped, the Hg{sup 0} reemission continued for more than 2 h. In addition, a significant Hg{sup 0} reemission was also detected outside the scrubber loop. In an attempt to understand the Hg{sup 0} reemission increase across the wet scrubber system under transient and steady states and to understand the underlying relationship with the mercury complexes retained in the wet scrubber system, a mercury reemission model was developed. With this model, it was found that the Hg{sup 0} reemission rate under the current testing conditions can be simulated by a first-order reaction, and only a portion of HgS(IV) complexes retained in the slurry were participating in the reemission reaction. 5 refs., 6 figs., 1 gab.