Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

On the interpretation of Langmuir probe data inside a spacecraft sheath

If a Langmuir probe is located inside the sheath of a negatively charged spacecraft, there is a risk that the probe characteristic is modified compared to that of a free probe in the ambient plasma. We have studied this probe-in-spacecraft-sheath problem in the parameter range of a small Langmuir probe (with radius r{sub LP}<<{lambda}{sub D}) using a modified version of the orbit motion limited (OML) probe theory. We find that the ambient electron contribution I{sub e}(U{sub LP}) to the probe characteristic is suitably analyzed in terms of three regions of applied probe potential U{sub LP}. In region I, where the probe is negatively charged (i.e., U{sub LP} U{sub 1}, there is first a transition region II in applied potential, U{sub 1}<U{sub LP}<U{sub 2}, in which the key factor to determine the shape of I{sub e}(U{sub LP}) is a potential minimum U{sub M} between the probe and the ambient plasma. This minimum gives the depth U{sub pl}-U{sub M} of a potential barrier that prevents the lowest energy ambient electrons from reaching the probe. For a high enough positive probe potential, in region III, the barrier becomes small. Here, I{sub e}(U{sub LP}) again approaches OML theory for a free probe. The boundary U{sub 2} between regions II and III is somewhat arbitrary; we propose a condition on the barrier, U{sub pl}-U{sub M}<<k{sub B}T{sub e}/e, as the definition of region III. The main findings in this work are qualitative rather than quantitative. The existence of the transition region points to that special care must be taken to extract plasma parameters from measured I(U{sub LP}) as the probe characteristic is likely to depart from usual OML in crucial respects: (1) the ambient plasma potential U{sub pl} falls into the transition region, but there is no obvious knee or other feature to identify it, (2) there is in this region no exponential part of I{sub e}(U{sub LP}) that can be used to obtain T{sub e}, instead, (3) the probe size is important in determining the curve shape. We have tentatively applied our simplified probe-in-sheath model to real probe data from the Cassini spacecraft, taken in the dense plasma of Saturn's magnetosphere. We propose that our model gives a better description than OML of measured Langmuir probe sweeps in space plasmas where the Langmuir probe is situated within the spacecraft sheath, i.e., for long Debye lengths. The understanding of these probe sweep effects in such regions may improve by self-consistent particle simulations of the spacecraft environment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chaotic electron trajectories in an electromagnetic wiggler free-electron laser with ion-channel guiding

Chaotic behavior of an electron motion in combined backward propagating electromagnetic wiggler and ion-channel electrostatic fields is studied. The Poincare surface-of-sections are employed to investigate chaotic behavior of electron motion. It is shown that the electron motion can exhibit chaotic behavior when the ion-channel density is low or medium, while for sufficiently high ion-channel density, the electron motion becomes regular (nonchaotic). Also, the chaotic trajectories decrease when the effects of self-fields of electron beam are taken into account and under Budker condition all trajectories become regular. The above result is in contrast with magnetostatic helical wiggler with axial magnetic field in which chaotic motion is produced by self-fields of electron beam. The chaotic and nonchaotic electron trajectories are confirmed by calculating Liapunov exponents.

43 PARTICLE ACCELERATORS↗

Laser beam combiner for Thomson scattering core LIDAR

The light detection and ranging Thomson scattering (TS) diagnostic is advantageous since it only requires a single view port into the tokamak. This technique requires a short pulse laser at high energy, usually showing a limited repetition rate. Having multiple lasers will increase the repetition rate. This paper presents a scanning mirror as a laser beam combiner. Measurements of the position accuracy and jitter show that the pointing stability of the laser beam is within {+-}25 {mu}rad for over tens of seconds. A control feedback loop is implemented to demonstrate the long term stability. Such a system could be applied for ITER and JET.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma bang time analysis at OMEGA

Absolute bang time measurements with the gas Cherenkov detector (GCD) and gamma reaction history (GRH) diagnostic have been performed to high precision at the OMEGA laser facility at the University of Rochester with bang time values for the two diagnostics agreeing to within 5 ps on average. X-ray timing measurements of laser-target coupling were used to calibrate a facility-generated laser timing fiducial with rms spreads in the measured coupling times of 9 ps for both GCD and GRH. Increased fusion yields at the National Ignition Facility (NIF) will allow for improved measurement precision with the GRH easily exceeding NIF system design requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stable coaxial-waveguide gyrotron backward-wave oscillator with distributed losses

This study analyzes the performance of a coaxial-waveguide gyrotron backward-wave oscillator (gyro-BWO) operating at the fundamental harmonic by considering mode competition, which may be attributed to higher-order axial modes and competing transverse modes. In the coaxial waveguide with a short length and uniform cross section, the threshold currents of the higher-order axial modes are substantially higher than the operating current. Additionally, when the beam voltage or the magnetic field is adjusted, the oscillation that neighbors the minimum start-oscillation current of a transverse mode has a positive-k{sub z} field profile, and is excited near the cutoff frequency. As a result, the distributed wall losses at the downstream end of the interaction structure effectively damp the positive-k{sub z} field, and raise significantly the minimum start-oscillation currents of the competing transverse modes. This study also investigates how the parameters, including lossy section length, outer wall resistivity, inner wall resistivity, and ratio of the outer radius to the inner radius, affect the start-oscillation currents of the competing transverse modes in order to obtain stable operation conditions in the frequency tuning range. As is forecasted, when using a 15 A electron beam, the Ka-band coaxial gyro-BWO produces an output power of 137 kW and 3 dB bandwidth of 4.2% by magnetic tuning and an output power of 145 kW and 3dB bandwidth of 2.0% by beam voltage tuning.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Obliquely propagating generalized lower-hybrid drift instability with nonlocal two-fluid theory in current sheet equilibrium

By employing nonlocal two-fluid analysis, a class of obliquely propagating current sheet drift instabilities with frequency in the lower-hybrid frequency range is investigated. A series of unstable modes with multiple eigenstates are found by numerical simulation after electrostatic approximation. It is found that the growth rate of the unstable modes, whose eigenfunctions are localized at the current sheet edge, increases as the propagation more oblique. However, as the wave vector attains more and more field-aligned components, the maximum growth rate suffers an acute drop after a certain critical angle, beyond which it finally diminishes. On the other hand, the growth rate associated with modes located near the center of the current sheet is found to be less sensitive to the increase in propagation angle, although it does undergo a gradual decrease until it is stabilized when the mode becomes near-field aligned.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatially resolvable optical emission spectrometer for analyzing density uniformity of semiconductor process plasma

We proposed a spatially resolved optical emission spectrometer (SROES) for analyzing the uniformity of plasma density for semiconductor processes. To enhance the spatial resolution of the SROES, we constructed a SROES system using a series of lenses, apertures, and pinholes. We calculated the spatial resolution of the SROES for the variation of pinhole size, and our calculated results were in good agreement with the measured spatial variation of the constructed SROES. The performance of the SROES was also verified by detecting the correlation between the distribution of a fluorine radical in inductively coupled plasma etch process and the etch rate of a SiO{sub 2} film on a silicon wafer.

36 MATERIALS SCIENCE↗

Stabilization of sample temperature in a surface-science vacuum chamber to 0.03 K and quartz-crystal microbalance frequency to 0.06 Hz over 0.5 h

Improvements have been made to a high-stability quartz-crystal microbalance for use in a typical surface-science, ultrahigh vacuum chamber, with a frequency stability of one part in 10{sup 8} (0.06 Hz) over 0.5 h. This gives a resolution equivalent to 2% of an atomic monolayer of oxygen over 0.5 h. The quartz-crystal microbalance (QCM) crystal can be rotated to different surface-analysis positions in the chamber. These characteristics open up the combination of surface and bulk adsorption studies on the same sample without transferring the sample to another chamber. To accomplish this, it was necessary to stabilize the sample temperature to {+-}0.03 K over several hours. The oscillator performance is illustrated by the uptake of oxygen by a gold-plated QCM crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact streak camera for 150 fs time resolved measurement of bright pulses in ultrafast electron diffraction

We have developed a compact streak camera suitable for measuring the duration of highly charged subrelativistic femtosecond electron bunches with an energy bandwidth in the order of 0.1%, as frequently used in ultrafast electron diffraction (UED) experiments for the investigation of ultrafast structural dynamics. The device operates in accumulation mode with 50 fs shot-to-shot timing jitter, and at a 30 keV electron energy, the full width at half maximum temporal resolution is 150 fs. Measured durations of pulses from our UED gun agree well with the predictions from the detailed charged particle trajectory simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broken ergodicity in two-dimensional homogeneous magnetohydrodynamic turbulence

Two-dimensional (2D) homogeneous magnetohydrodynamic (MHD) turbulence has many of the same qualitative features as three-dimensional (3D) homogeneous MHD turbulence. These features include several ideal (i.e., nondissipative) invariants along with the phenomenon of broken ergodicity (defined as nonergodic behavior over a very long time). Broken ergodicity appears when certain modes act like random variables with mean values that are large compared to their standard deviations, indicating a coherent structure or dynamo. Recently, the origin of broken ergodicity in 3D MHD turbulence that is manifest in the lowest wavenumbers was found. Here, we study the origin of broken ergodicity in 2D MHD turbulence. It will be seen that broken ergodicity in ideal 2D MHD turbulence can be manifest in the lowest wavenumbers of a finite numerical model for certain initial conditions or in the highest wavenumbers for another set of initial conditions. The origins of broken ergodicity in an ideal 2D homogeneous MHD turbulence are found through an eigenanalysis of the covariance matrices of the probability density function and by an examination of the associated entropy functional. When the values of ideal invariants are kept fixed and grid size increases, it will be shown that the energy in a few large modes remains constant, while the energy in any other mode is inversely proportional to grid size. Also, as grid size increases, we find that broken ergodicity becomes manifest at more and more wavenumbers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High accuracy wavelength calibration for a scanning visible spectrometer

Spectroscopic applications for plasma velocity measurements often require wavelength accuracies {<=}0.2 A. An automated calibration, which is stable over time and environmental conditions without the need to recalibrate after each grating movement, was developed for a scanning spectrometer to achieve high wavelength accuracy over the visible spectrum. This method fits all relevant spectrometer parameters using multiple calibration spectra. With a stepping-motor controlled sine drive, an accuracy of {approx}0.25 A has been demonstrated. With the addition of a high resolution (0.075 arc sec) optical encoder on the grating stage, greater precision ({approx}0.005 A) is possible, allowing absolute velocity measurements within {approx}0.3 km/s. This level of precision requires monitoring of atmospheric temperature and pressure and of grating bulk temperature to correct for changes in the refractive index of air and the groove density, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temporal symmetry of individual filaments in different spatial symmetry filaments pattern in a dielectric barrier discharge

The temporal behavior of individual filament in different spatial symmetry filaments patterns in dielectric barrier discharge is investigated by using an optical method. A series of return maps of the discharge moments of individual filaments is given. It is found that the temporal symmetry of individual filament changes with the change of the spatial symmetry of filaments pattern as the applied voltage increases. The role of wall charges for this phenomenon is analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Symmetries, weak symmetries, and related solutions of the Grad-Shafranov equation

We discuss a new family of solutions of the Grad-Shafranov (GS) equation that describes D-shaped toroidal plasma equilibria with sharp gradients at the plasma edge. These solutions have been derived by exploiting the continuous Lie symmetry properties of the GS equation and in particular a special type of 'weak' symmetries. In addition, we review the continuous Lie symmetry properties of the GS equation and present a short but exhaustive survey of the possible choices for the arbitrary flux functions that yield GS equations admitting some continuous Lie symmetry. Particular solutions related to these symmetries are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microcontroller based system for electrical breakdown time delay measurement in gas-filled devices

This paper presents realization of a digital embedded system for measuring electrical breakdown time delay. The proposed system consists of three major parts: dc voltage supply, analog subsystem, and a digital subsystem. Any dc power source with the range from 100 to 1000 V can be used in this application. The analog subsystem should provide fast and accurate voltage switching on the testing device as well as transform the signals that represent the voltage pulse on the device and the device breakdown into the form suitable for detection by a digital subsystem. The insulated gate bipolar transistor IRG4PH40KD driven by TC429 MOSFET driver is used for high voltage switching on the device. The aim of a digital subsystem is to detect the signals from the analog subsystem and to measure the elapsed time between their occurrences. Moreover, the digital subsystem controls various parameters that influence time delay and provides fast data storage for a large number of measured data. For this propose, we used the PIC18F4550 microcontroller with a full-speed compatible universal serial bus (USB) engine. Operation of this system is verified on different commercial and custom made gas devices with different structure and breakdown mechanisms. The electrical breakdown time delay measurements have been carried out as a function of several parameters, which dominantly influence electrical breakdown time delay. The obtained results have been verified using statistical methods, and they show good agreement with the theory. The proposed system shows good repeatability, sensitivity, and stability for measuring the electrical breakdown time delay.

36 MATERIALS SCIENCE↗

Superresolution confocal technology for displacement measurements based on total internal reflection

In order to achieve a higher axial resolution for displacement measurement, a novel method is proposed based on total internal reflection filter and confocal microscope principle. A theoretical analysis of the basic measurement principles is presented. The analysis reveals that the proposed confocal detection scheme is effective in enhancing the resolution of nonlinearity of the reflectance curve greatly. In addition, a simple prototype system has been developed based on the theoretical analysis and a series of experiments have been performed under laboratory conditions to verify the system feasibility, accuracy, and stability. The experimental results demonstrate that the axial resolution in displacement measurements is better than 1 nm in a range of 200 nm which is threefold better than that can be achieved using the plane reflector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High speed digital holography for density and fluctuation measurements (invited)

The state of the art in electro-optics has advanced to the point where digital holographic acquisition of wavefronts is now possible. Holographic wavefront acquisition provides the phase of the wavefront at every measurement point. This can be done with accuracy on the order of a thousandth of a wavelength, given that there is sufficient care in the design of the system. At wave frequencies which are much greater than the plasma frequency, the plasma index of refraction is linearly proportional to the electron density and wavelength, and the measurement of the phase of a wavefront passing through the plasma gives the chord-integrated density directly for all points measured on the wavefront. High-speed infrared cameras (up to {approx}40 000 fps at {approx}64x4 pixels) with resolutions up to 640x512 pixels suitable for use with a CO{sub 2} laser are readily available, if expensive.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Traveling wave model for laser-guided discharges

We present an easily solvable 1D traveling wave model for laser-guided discharges. By assuming constant propagation speed u, the hydro/electrodynamic/chemistry equations are reduced to ordinary differential equations in retarded time {tau}. Negative discharges are shown to propagate only if u>{mu}E{sub b}, where {mu} is electron mobility and E{sub b} is the breakdown field; positive discharges propagate only if the channel preconductance exceeds {approx}6x10{sup -11} m/{Omega}. The axial electric field E is shown to spike up to several times E{sub b} and then relax to {approx}E{sub b} for as long as the gas remains cold. In this streamer region, the channel conductance, current, and potential all increase linearly with {tau}. The transition to the leader stage, where E is much smaller, occurs in two steps: excitation of vibrational and low-lying electronic states, then gas heating. The propagation range decreases as a function of initial radius and (for given maximum voltage) of the voltage rise rate. Expansion of the hot channel is shown to increase the range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗