Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plug”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

The lightcone bootstrap and the spectrum of the 3d Ising CFT

In this paper. we compute numerically the dimensions and OPE coefficients of several operators in the 3d Ising CFT, and then try to reverse-engineer the solution to crossing symmetry analytically. Our key tool is a set of new techniques for computing infinite sums of SL(2,R) conformal blocks. Using these techniques, we solve the lightcone bootstrap to all orders in an asymptotic expansion in large spin, and suggest a strategy for going beyond the large spin limit. We carry out the first steps of this strategy for the 3d Ising CFT, deriving analytic approximations for the dimensions and OPE coefficients of several infinite families of operators in terms of the initial data $\{\Delta_\sigma,\Delta_\epsilon,f_{\sigma\sigma\epsilon},f_{\epsilon\epsilon\epsilon},c_T\}$. The analytic results agree with numerics to high precision for about 100 low-twist operators (correctly accounting for O(1) mixing effects between large-spin families). Plugging these results back into the crossing equations, we obtain approximate analytic constraints on the initial data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Embolization of the Internal Iliac Artery: Cost-Effectiveness of Two Different Techniques

The purpose of this study was to compare the cost-effectiveness of coils versus the Amplatzer Vascular Plug (AVP) for occlusion of the internal iliac artery (IAA). Between 2002 and January 2006, 13 patients (mean age 73 {+-} 13 years) were referred for stent-grafting of abdominal aortic aneurysm (n = 6); type I distal endoleak (n = 3), isolated iliac aneurysm (n = 3), or rupture of a common iliac aneurysm (n = 1). In all patients, extension of the stent-graft was needed because the distal neck was absent. Two different techniques were used to occlude the IIA: AVP in seven patients (group A) and coil embolization in six patients (group C). Immediate results and direct material costs were assessed retrospectively. Immediate success was achieved in all patients, and simultaneous stent-grafting was successfully performed in two of six patients in group C versus five of seven patients in group A. In all group A patients, a single AVP was sufficient to achieve occlusion of the IIA, accounting for a mean cost of 485 Euro , whereas in group C patients, an average of 7 {+-} 3 coils were used, accounting for a mean cost of 1,745 Euro . Mean average cost savings using the AVP was 1,239 Euro . When IIA occlusion is needed, the AVP allows a single-step procedure at significant cost savings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Testing Percutaneous Arterial Closure Devices: An Animal Model

The ovine superficial femoral artery was used for testing the efficacy of percutaneous arterial closure devices (PACDs) in their developmental stage. Two topical devices containing chitostan, one staple-mediated PACD and a porcine small intestinal submucosa plug, were tested by follow-up angiography in 37 sheep. Absence or presence of bleeding and time to bleeding cessation were the main criteria for evaluation of PAVD efficacy. The results of these tests directed modification of individual PACDs and improved their efficacy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Obesity: An Independent Risk Factor for Insufficient Hemostasis Using the AngioSeal Vascular Closure Device After Antegrade Puncture

Purpose: This study was designed to investigate the efficacy of the AngioSeal vascular closure device after antegrade puncture of the femoral artery. Methods: In a prospective study, 120 consecutive patients underwent lower limb vascular intervention by an antegrade access to the common femoral artery (CFA). After intervention, a 6F (n = 88) or an 8F (n = 32) AngioSeal vascular closure device was used to achieve hemostasis. The technical success or the cause of failure was documented. In addition, the coagulation status (platelets, INR, prothrombin time, atrial thromboplastin time (PTT)), hypertonus, locoregional habitus of the groin, body mass index (BMI), presence of calcifications, and history of previous surgical interventions of the CFA were evaluated. Results: Hemostasis was achieved in 97 patients (81%). In 12 patients (10%), persistent bleeding of the puncture site required manual compression. In another nine patients (8%) a kink of the sheath obviated the passage of the collagen plug toward the vessel, and in two patients the anchor dislodged out of the vessel, requiring manual compression. There were no significant differences between the groups of successful and unsuccessful sealing regarding the mean platelets (241 vs. 254 * 10{sup 9}/l; P = 0.86), INR (1.06 vs. 1.02; P = 0.52), prothrombin time (90% vs. 90%; P = 0.86), and PTT (30 vs. 31 s; P = 0.82). However, unsuccessful sealing was more likely in obese patients with an increased BMI (26.6 vs. 28.8 kg/m{sup 2}; P = 0.04). Conclusions: Obesity seems to be an independent risk factor for insufficient sealing using the AngioSeal vascular closure device after antegrade puncture of the CFA. In 8% of our patients, hemostasis could not be achieved due to kink of the flexible sheath.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Transsplenic Access to the Portal Vein for Management of Vascular Complication in Patients with Chronic Liver Disease

Purpose: To evaluate the safety and feasibility of percutaneous transsplenic access to the portal vein for management of vascular complication in patients with chronic liver diseases. Methods: Between Sept 2009 and April 2011, percutaneous transsplenic access to the portal vein was attempted in nine patients with chronic liver disease. Splenic vein puncture was performed under ultrasonographic guidance with a Chiba needle, followed by introduction of a 4 to 9F sheath. Four patients with hematemesis or hematochezia underwent variceal embolization. Another two patients underwent portosystemic shunt embolization in order to improve portal venous blood flow. Portal vein recanalization was attempted in three patients with a transplanted liver. The percutaneous transsplenic access site was closed using coils and glue. Results: Percutaneous transsplenic splenic vein catheterization was performed successfully in all patients. Gastric or jejunal varix embolization with glue and lipiodol mixture was performed successfully in four patients. In two patients with a massive portosystemic shunt, embolization of the shunting vessel with a vascular plug, microcoils, glue, and lipiodol mixture was achieved successfully. Portal vein recanalization was attempted in three patients with a transplanted liver; however, only one patient was treated successfully. Complete closure of the percutaneous transsplenic tract was achieved using coils and glue without bleeding complication in all patients. Conclusion: Percutaneous transsplenic access to the portal vein can be an alternative route for portography and further endovascular management in patients for whom conventional approaches are difficult or impossible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Celiac Injury Due to Arcuate Ligament: An Endovascular Approach

Celiac trunk injures are rare events, with high mortality rates and difficult management. Endovascular treatment may be considered to avoid bleeding. We report a case of severe bleeding in a 37-year-old man resulting from celiac trunk stretching after a motorcycle crash. Because direct celiac trunk catheterization was not possible, a retrograde catheterization of the common hepatic artery was performed via the superior mesenteric artery. Two vascular plugs (type IV) were released, and the exclusion of the celiac trunk origin was completed with the deployment of an aortic cuff. The patient's clinical condition immediately improved, and after 6 months' follow-up, imaging confirmed the complete exclusion of the celiac trunk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Suitability of Exoseal Vascular Closure Device for Antegrade Femoral Artery Puncture Site Closure

Purpose. To assess the efficacy and safety of the Exoseal vascular closure device for antegrade puncture of the femoral artery. Methods. In a prospective study from February 2011 to January 2012, a total of 93 consecutive patients received a total of 100 interventional procedures via an antegrade puncture of the femoral artery. An Exoseal vascular closure device (6F) was used for closure in all cases. Puncture technique, duration of manual compression, and use of compression bandages were documented. All patients were monitored by vascular ultrasound and color-coded duplex sonography of their respective femoral artery puncture site within 12 to 36 h after angiography to check for vascular complications. Results. In 100 antegrade interventional procedures, the Exoseal vascular closure device was applied successfully for closure of the femoral artery puncture site in 96 cases (96 of 100, 96.0 %). The vascular closure device could not be deployed in one case as a result of kinking of the vascular sheath introducer and in three cases because the bioabsorbable plug was not properly delivered to the extravascular space adjacent to the arterial puncture site, but instead fully removed with the delivery system (4.0 %). Twelve to 36 h after the procedure, vascular ultrasound revealed no complications at the femoral artery puncture site in 93 cases (93.0 %). Minor vascular complications were found in seven cases (7.0 %), with four cases (4.0 %) of pseudoaneurysm and three cases (3.0 %) of significant late bleeding, none of which required surgery. Conclusion. The Exoseal vascular closure device was safely used for antegrade puncture of the femoral artery, with a high rate of procedural success (96.0 %), a low rate of minor vascular complications (7.0 %), and no major adverse events.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aortic Branch Artery Pseudoaneurysms Associated with Intramural Hematoma: When and How to Do Endovascular Embolization

To describe when and how to perform endovascular embolization of aortic branch artery pseudoaneurysms associated with type A and type B intramural hematoma (IMH) involving the descending thoracic and abdominal aorta (DeBakey I and III) that increased significantly in size during follow-up. Sixty-one patients (39 men; mean {+-} standard deviation age 66.1 {+-} 11.2 years) with acute IMH undergoing at least two multidetector computed tomographic examinations during follow-up for 12 months or longer were enrolled. Overall, 48 patients (31 men, age 65.9 {+-} 11.5) had type A and type B IMH involving the descending thoracic and abdominal aorta (DeBakey I and III). Among the 48 patients, 26 (54 %; 17 men, aged 64.3 {+-} 11.4 years) had 71 aortic branch artery pseudoaneurysms. Overall, during a mean follow-up of 22.1 {+-} 9.5 months (range 12-42 months), 31 (44 %) pseudoaneurysms disappeared; 22 (31 %) decreased in size; two (3 %) remained stable; and 16 (22 %) increased in size. Among the 16 pseudoaneurysms with increasing size, five of these (three intercostal arteries, one combined intercostobronchial/intercostal arteries, one renal artery), present in five symptomatic patients, had a significant increase in size (thickness >10 mm; width and length >20 mm). These five patients underwent endovascular embolization with coils and/or Amplatzer Vascular Plug. In all patients, complete thrombosis and exclusion of aortic pseudoaneurysm and relief of back pain were achieved. Aortic branch artery pseudoaneurysms associated with type A and type B IMH involving the descending thoracic and abdominal aorta (DeBakey I and III) may be considered relatively benign lesions. However, a small number may grow in size or extend longitudinally with clinical symptoms during follow-up, and in these cases, endovascular embolization can be an effective and safe procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Two Pseudoaneurysms Originating From the Left Ventricle

A 67-year-old woman resented with an acute type A aortic dissection, which was treated surgically with aortic valve replacement as a composite graft with reimplantation of the coronary arteries. At the end of surgery, a left-ventricular venting catheter was placed through the apex and closed with a buffered suture. Consecutive computed tomography (CT) examinations verified a growing apex pseudoaneurysm. Communication between the ventricle and the pseudoaneurysm was successfully closed with an Amplatz septal plug by the transfemoral route. Follow-up CT showed an additional pseudoaneurysm, which also was successfully closed using the same method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of an Aneurysmal Aberrant Systemic Artery Supplying a Pulmonary Sequestrum

An aberrant systemic artery originating from the abdominal aorta supplying a pulmonary sequestration is a rare congenital malformation. This causes a left-to-left shunt. Symptoms include recurrent pneumonias, hemoptysis, and, in the long term, heart failure. Aneurysm of the aberrant vessel is rarely seen. Traditionally, treatment of pulmonary sequestrations includes ligation of the feeding vessel and lobectomy. A new promising treatment is an endovascular approach. Only a few cases describe endovascular treatment of pulmonary sequestration. This is the first published case of a giant aneurysmal branch from the abdominal aorta to the normal basal segments of the lung, successfully occluded with an Amplatzer Vascular Plug II (AVP II, St.Jude Medical, MN, USA) alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Embolization of Anomalous Systemic Arterial Supply to Normal Basal Segments of the Lung

PurposeTo evaluate transarterial embolization (TAE) for the management of anomalous systemic arterial (ASA) supply to normal basal segments of the lung.MethodsThirteen patients with ASA supply to normal basal segments of the lung underwent TAE. All patients presented with hemoptysis and had complete-type anomalies on pre-TAE or post-TAE computed tomography (CT). The anomaly was unilateral in all patients; 11 lesions were located in the left lung and 2 in the right. All patients underwent embolization with coils (n = 10) or a vascular plug (n = 3). Procedural success, clinical efficacy, and complications were assessed. Mean post-TAE CT and clinical follow-up was 25.4 and 42.1 months, respectively.ResultsTechnical success was achieved in 100 % of cases. Several changes were noted on follow-up CT: complete obstruction of the ASA in all cases, normal (n = 11) or decreased (n = 2) density of the affected lung parenchyma, reduction of the primary enlarged inferior pulmonary vein in all cases, and pulmonary infarction and thickening of the corresponding bronchial artery (n = 4). The main complication was pulmonary infarction in four cases.ConclusionTAE is a safe, effective, and minimally invasive therapeutic option for patients with ASA supply to normal basal segments of the lung.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Injection of Blood Products Versus Gelatin Sponge as a Technique for Local Hemostasis

PurposeTo provide a method of reducing risk of minimally invasive procedures on patients with abnormal hemostasis and evaluate efficacy of direct fresh frozen plasma injection through a procedure needle tract compared to Gelfoam (gelatin sponge) administration.Materials and MethodsEighty patients with elevated international standardized ratio (INR) undergoing minimally invasive procedures using imaging guidance were selected retrospectively. Forty patients had received Gelfoam as a means of tract embolization during the procedure. The other 40 received local fresh frozen plasma (FFP) through the needle tract. The number of complications and clinically significant bleeding events were recorded. A threshold of 30 cc of blood loss after a procedure was used to identify excess bleeding.ResultsNo patients experienced clinically significant bleeding after administration of FFP. Five patients experienced postoperative drops in hemoglobin or hematomas after administration of Gelfoam.ConclusionLocal injection of blood products can reduce postprocedure bleeding in patients undergoing minimally invasive procedures and provides a safe alternative to the use of synthetic fibrin plugs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Closure Devices for Iatrogenic Thoraco-Cervical Vascular Injuries

IntroductionThe unintentional arterial placement of a central venous line can have catastrophic complications. The purpose of this systematic review is to assess and analyse the available evidence regarding the use of the various vascular closure devices (VCDs) for the management of iatrogenic thoraco-cervical arterial injuries (ITCAI).MethodsA systematic review was performed according to PRISMA guidelines.ResultsThirty-two relevant case series and case reports were identified with a total of 69 patients having being studied. In the majority of the studies, plug-based VCDs were used (81%) followed by suture-based devices (19%). The majority of studies reported successful outcomes from the use of VCDs in terms of achieving immediate haemostasis without any acute complications. Long-term follow-up data were only available in nine studies with only one case of carotid pseudoaneurysm being reported after 1-month post-procedure. All other cases had no reported long-term complications. Five studies performed direct or indirect comparisons between VCDs and other treatments (open surgery or stent grafting) suggesting no significant differences in safety or effectiveness.ConclusionAlthough there is limited evidence, VCDs appear to be safe and effective for the management of ITCAIs. Further research is warranted regarding the effectiveness of this approach in comparison to surgery and in order to identify those patients who are more likely to benefit from this minimally invasive approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Approach, Technical Success, Complications, and Stent Patency of Sharp Recanalization for the Treatment of Chronic Venous Occlusive Disease: Experience in 123 Patients

Purpose: To report the technical success and complications following sharp recanalization of chronic venous occlusions. Materials and Methods: A total of 123 patients, including 75 (61.0%) men and 48 (39.0%) women, with mean age of 50.5 ± 17.5 years (range 19–90 years), underwent sharp recanalization of chronic venous occlusions. The etiologies of occlusion were chronic deep venous thrombosis (n = 43; 35.0%), prior central venous access (n = 39; 31.7%), indwelling cardiac leads (n = 21; 17.1%), and occluded venous stents (n = 20; 16.3%). The sites of venous occlusion included 59/123 (48.0%) thoracic central veins, 37 (30.1%) non-thoracic central veins, and 27 (22.0%) peripheral veins. Median length of occlusion was 3.2 ± 1.4 cm (range 1.3–10.9 cm). Results: Sharp recanalization was most commonly attempted with transseptal needles in 108/123 (87.8%), with a mean number of 1.2 ± 0.4 crossing devices per patient (range 1–4 devices). Targeting devices included a loop snare (n = 92; 74.8%), partially deployed Wallstent (n = 21; 17.1%), partially deployed Amplatzer vascular plug (n = 8; 6.5%), and an angioplasty balloon (n = 3; 2.4%). Technical success was achieved in 111 (90.2%) patients. There were 3 (2.4%) severe, 1 (0.8%) moderate, and 7 (5.7%) minor adverse events. Severe adverse events included 1 case each of pericardial tamponade, hemothorax, and inferior vena cava filter occlusion. 88 (71.5%) patients had venous stents placed; at the last follow-up examination, 68/86 (79.0%) stents were patent. Conclusion: Sharp recanalization has a high technical success and low rate of adverse events in the recanalization of chronic venous occlusions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiple Bifurcated Covered Self-Expanding Metallic Stents for Complex Tracheobronchial Fistulas or Stenosis

Objective: We aimed to determine the safety and feasibility of bifurcated covered self-expanding stents for the treatment of complex tracheobronchial fistulas or stenosis. Methods: Twenty-eight patients were treated by multiple bifurcated covered airway stents (Micro-Tech Co. Ltd., Nanjing, China), including 18 cases of gastrobronchial or gastrotracheal fistula, 6 cases of bronchopleural fistula and 4 cases of severe tracheobronchial stenosis. The large bifurcated covered stent was placed at the main carina, and the small stents were inserted into primary right carina or secondary left carina. Clinical and imaging data were retrospectively analyzed. Results: Stents were successfully inserted in 27 patients at the first attempt. In total, 29 large bifurcated covered stents, 27 small bifurcated covered stents and 5 small bifurcated covered single-plugged stents were inserted. All patients with fistula could resume eating without coughing after the procedure. No perioperative death or severe complications occurred. Two patients underwent stent removal due to intolerance of stenting; the clinical success rate was 93% (26/28). Nineteen complications were found in 12 patients; 8 patients needed stent removal or replacement, for a major complication rate of 29% (8/28). Eight patients underwent successful stent removal due to complications. Fifteen patients died of tumors and one patient died of pulmonary infection. The median survival was 33 months. Fistula recurrence was found in one patient 5 months after stenting, and second small bifurcated covered stent was inserted. Conclusions: Multiple bifurcated covered metallic stenting is effective and safe for complex tracheobronchial fistulas or stenosis, with good symptom palliation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Bronchial Embolization to Treat Intractable Bronchobiliary Fistula

Sixty-four-year-old female who underwent hemi-hepatectomy for intrahepatic cholangiocarcinoma a year ago presented with biliary sputum, cough and fever. Cross-sectional imaging showed a recurred tumor involving right diaphragmatic area and an abscess formation in liver dome with adjacent right lower lobe of lung. Percutaneous transhepatic biliary drainage and percutaneous drainage of lung abscess were performed. Tubogram showed connections between the lung abscess cavity and multiple distal bronchi, suggesting bronchobiliary fistulas. Two weeks of drainage treatment did not relieve symptoms. We successfully treated intractable bronchobiliary fistula via image-guided percutaneous access to closest distal bronchi near abscess with subsequent tandem placement of vascular plugs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Post-Biopsy Manoeuvres to Reduce Pneumothorax Incidence in CT-Guided Transthoracic Lung Biopsies: A Systematic Review and Meta-analysis

This systematic review and meta-analysis investigated post-biopsy manoeuvres to reduce pneumothorax following computed tomography-guided percutaneous transthoracic lung biopsy. Twenty-one articles were included with 7080 patients. Chest drain insertion rates were significantly reduced by ninefold with the normal saline tract sealant compared to controls (OR 0.11, 95% CI 0.02–0.48), threefold with the rapid rollover manoeuvre to puncture site down (OR 0.34, 95% CI 0.18–0.63), threefold with the tract plug (OR 0.33, 95% CI 0.22–0.48) and threefold with the blood patch (OR 0.39, 95% CI 0.26–0.58). The absolute chest drain insertion rates were the lowest in the normal saline tract sealant (0.8% vs 7.3% for controls), rapid rollover (1.9% vs 5.2%), deep expiration and breath-hold on needle extraction (0.9% vs 1.8%) and standard rollover versus no rollover (2.6% vs 5.2%). These findings highlight post-biopsy manoeuvres which could help reduce pneumothorax and chest drain insertions following lung biopsies. Level of Evidence: Level 1/no level of evidence, systematic review.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of a fluvial aquifer at a range of depths and scales: the Triassic St Bees Sandstone Formation, Cumbria, UK

Fluvial sedimentary successions represent porous media that host groundwater and geothermal resources. Additionally, they overlie crystalline rocks hosting nuclear waste repositories in rift settings. The permeability characteristics of an arenaceous fluvial succession, the Triassic St Bees Sandstone Formation in England (UK), are described, from core-plug to well-test scale up to ~1 km depth. Within such lithified successions, dissolution associated with the circulation of meteoric water results in increased permeability (K~10{sup −1}–10{sup 0} m/day) to depths of at least 150 m below ground level (BGL) in aquifer systems that are subject to rapid groundwater circulation. Thus, contaminant transport is likely to occur at relatively high rates. In a deeper investigation (> 150 m depth), where the aquifer has not been subjected to rapid groundwater circulation, well-test-scale hydraulic conductivity is lower, decreasing from K~10{sup −2} m/day at 150–400 m BGL to 10{sup −3} m/day down-dip at ~1 km BGL, where the pore fluid is hypersaline. Here, pore-scale permeability becomes progressively dominant with increasing lithostatic load. Notably, this work investigates a sandstone aquifer of fluvial origin at investigation depths consistent with highly enthalpy geothermal reservoirs (~0.7–1.1 km). At such depths, intergranular flow dominates in unfaulted areas with only minor contribution by bedding plane fractures. However, extensional faults represent preferential flow pathways, due to presence of high connective open fractures. Therefore, such faults may (1) drive nuclear waste contaminants towards the highly permeable shallow (< 150 m BGL) zone of the aquifer, and (2) influence fluid recovery in geothermal fields.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗