Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,681 records · Page 94

Geometrical optics without singularities: using the ray time as the coordinate space

Geometrical optics (GO) is widely used for reduced modelling of waves in plasmas, but it fails near reflection points, where it predicts a spurious singularity of the wave amplitude. We show how to avoid this singularity by adopting a different representation of the wave equation. Instead of the physical coordinate 𝑥 and the wavevector 𝑘, we use the ray time 𝜏 as the new canonical coordinate and the ray energy ℎ as the associated canonical momentum. To derive the envelope equation in the 𝜏-representation, we construct the Weyl symbol calculus on the (𝜏,ℎ) space and show that the corresponding Weyl symbols are related to their (𝑥,𝑘) counterparts by the Airy transform. This allows us to express the coefficients in the envelope equation through the known properties of the original dispersion operator. When necessary, solutions of this equation can be mapped to the 𝑥-space using a generalised metaplectic transform. However, the field per se might not even be needed in practice. Instead, knowing the corresponding Wigner function usually suffices for linear and quasilinear calculations. As a Weyl symbol itself, the Wigner function can be mapped analytically, using the aforementioned Airy transform. We show that the standard Airy patterns that form in regions where conventional GO fails are successfully reproduced within metaplectic GO (MGO) simply by remapping the field from the 𝜏-space to the 𝑥-space. An extension to mode-converting waves is also presented. This formulation, which we call generalised MGO, can be particularly useful, for example, for reduced modelling of the O–X conversion in inhomogeneous plasma near the critical density, an effect that is important for fusion applications and also occurs in the ionosphere. Overall, MGO can replace GO for any practical purposes, because it better handles cutoffs and is similar otherwise.

plasma waves↗

Experimental characterization and potential energy savings of insulated cladding for U.S. residential buildings

This study evaluates a novel insulated cladding composed of foamed cement and vinyl siding that is designed as a retrofit product to enhance thermal performance in U.S. residential buildings. Experimental measurements showed that foamed cement exhibits a thermal conductivity of 0.0334–0.0365 W/m-K (R-value of 4.0–4.3 °F⋅ft 2 ⋅h/BTU), which is significantly higher than that of conventional fiber cement boards. Although mechanical testing confirmed the material’s brittleness and low strength, it also indicated its suitability for nonstructural insulation applications. Water vapor permeability testing demonstrated effective moisture resistance with the polymer coating. To evaluate the insulated cladding’s energy performance, we used the U.S. Department of Energy’s prototype single-family building model and simulated across 50 locations spanning 16 International Energy Conservation Code climate zones. The R-7 (R-value of 7 °F⋅ft 2 ⋅h/BTU per inch) retrofit cladding resulted in heating energy savings up to 275 therms (Fairbanks, AK) and cooling energy savings up to 1,547 kWh (Phoenix, AZ). The energy cost savings varied by region, but the highest annual cost savings ($\$$434/year) were observed in Santa Maria, CA, and the highest annual cost savings percentage (37 %) were noted in Monterey, CA. On a national scale, the insulated retrofit provided an average annual energy cost reduction of 16 %, highlighting the cladding system’s broad applicability and financial viability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis and Design of Crew Sleep Station for ISS

This paper details the analysis and design of the Temporary Sleep Station (TeSS) environmental control system for International Space Station (ISS). The TeSS will provide crewmembers with a private and personal space, to accommodate sleeping, donning and doffing of clothing, personal communication and performance of recreational activities. The need for privacy to accommodate these activities requires adequate ventilation inside the TeSS. This study considers whether temperature, carbon dioxide, and humidity within the TeSS remain within crew comfort and safety levels for various expected operating scenarios. Evaluation of these scenarios required the use and integration of various simulation codes. An approach was adapted for this study, whereby results from a particular code were integrated with other codes when necessary. Computational Fluid Dynamics (CFD) methods were used to evaluate the flow field inside the TeSS, from which local gradients for temperature, velocity, and species concentration such as CO (sub 2) could be determined. A model of the TeSS, containing a human, as well as equipment such as a laptop computer, was developed in FLUENT, a finite-volume code. Other factors, such as detailed analysis of the heat transfer through the structure, radiation, and air circulation from the TeSS to the US Laboratory Aisle, where the TeSS is housed, were considered in the model. A complementary model was developed in G189A, a code which has been used by NASA/JSC for environmental control systems analyses since the Apollo program. Boundary conditions were exchanged between the FLUENT and G189A TeSS models. G189A provides human respiration rates to the FLUENT model, while the FLUENT model provides local convective heat transfer coefficients to G189A model. An additional benefit from using an approach with both a systems simulation and CFD model, is the capability to verify the results of each model by comparison to the results of the other model. The G189A and FLUENT models were used to evaluate various ventilation designs for the TeSS over a range of operating conditions with varying crew metabolic load, equipment operating modes, ventilation flow rates, and with the TeSS doors open and closed. Results from the study were instrumental in the optimization of a design for the TeSS ventilation hardware. A special case was considered where failure of the TeSS ventilation system occurred. In this case, a study was conducted in order to determine the time required for the CO (sub 2) concentration inside the TeSS to increase to ISS limit values under transient conditions. A lumped-capacitance code, SINDA-FLUINT was used in this case to provide accurate predictions of the human reaction to the TeSS cabin conditions including core and skin temperatures and body heat storage. A simple two-dimensional CFD model of a crewmember inside the TeSS was developed in FLUENT in order to determine the volume envelope of the respired air from the human, which maintained a minimum velocity profile. This volume was then used in the SINDA-FLUINT model to facilitate the calculations of CO (sub 2) concentrations, dry bulb temperatures and humidity levels inside the TeSS.

Keener, John F.↗

Mixed effects associated with air ingress in graphite channels

The next generation of nuclear power plants, such as Modular High Temperature Gas-Cooled Reactors (MHTGR), have passive safety design features to overcome transients during off-normal operation but it is unproven whether their safety systems will perform as per design requirements. The design and construction of a facility, to investigate the passive safety response of the complete reactor system will require significant resources. Therefore, a practical approach is to improve the understanding of this multi-physics or mixed effect problem in laboratory scale set-ups and computational models. The HTGR related separate effects experiments at academic institutions and other laboratories have been developed to provide validation data and complement computational efforts to identify critical issues related to passive safety design. There are several separate effect experimental studies currently under investigation or recently conducted by several academic institutions in U.S and throughout the world. The High Temperature Test Facility (HTTF) has been constructed at Oregon State University to conduct integral thermal-hydraulics experiments for the development of HTGRs. For Depressurized Conduction Cooling (DCC) experiments in HTTF, a mixture of nitrogen and helium gas is used to study internal natural convection up to 650?C. Similarly many other experimental studies have emphasized on HTGR core and plenum-to-plenum thermal-hydraulic behavior but with inert gases such as nitrogen or non-oxidizing solid substitutes for graphite. There is limited experimental data of mixed oxidation effects upon air ingress in nuclear grade graphite leading changes to thermal properties, heat generation due to chemical reactions and natural convection of air-helium mixture inside core at high temperatures (above 900?C). This work describes a unique experimental set-up developed by authors to conduct these mixed effect experiments. The current work is equally relevant to the designs well known by other names or geometries such as Very High Temperature Reactors (VHTRs) and Pebble Bed Modular Reactors (PBMRs). A common feature of HTGRs with passive safety design is that under certain accident conditions the decay heat is dissipated passively from the core by radiation/conduction/convection heat transport to the surrounding environment. Passive decay heat removal is one of the prime passive safety features of HTGRs and the heat conduction through the internal core region, graphite matrix, to the periphery is one of the major mechanisms of passive safety in HTGRs. The conduction and radiation heat transfer provide long-term heat removal but, during a Depressurized Loss of Forced Coolant (DLOFC) accident, the anticipated break in the coolant system will allow air ingress into the hot core region and can lead to graphite oxidation, which will negatively impact the core thermal behavior. In addition, air will also impact natural circulation of Helium and thus diminish the heat removal rate, which can further increase the graphite temperature. Therefore, both air ingress can eventually give rise to thermal instabilities and then to possible situations for breaching the safety envelope of TRISO fuel. This research summary is organized to present the background on oxidation studies, description of experimental setup and discussion of results in the following sections. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SMEX-Lite Modular Solar Array Architecture

For the most part, Goddard solar arrays have been custom designs that are unique to each mission. The solar panel design has been frozen prior to issuing an RFP for their procurement. There has typically been 6-9 months between RFP release and contract award, followed by an additional 24 months for performance of the contract. For Small Explorer (SMEX) missions, with three years between mission definition and launch, this has been a significant problem. The SMEX solar panels have been sufficiently small that the contract performance period has been reduced to 12-15 months. The bulk of this time is used up in the final design definition and fabrication of flight solar cell assemblies. Even so, it has been virtually impossible to have the spacecraft design at a level of maturity sufficient to freeze the solar panel geometry and release the RFP in time to avoid schedule problems with integrating the solar panels to the spacecraft. With that in mind, the SMEX-Lite project team developed a modular architecture for the assembly of solar arrays to greatly reduce the cost and schedule associated with the development of a mission- specific solar array. In the modular architecture, solar cells are fabricated onto small substrate panels. This modular panel (approximately 8.5" x 17" in this case) becomes the building block for constructing solar arrays for multiple missions with varying power requirements and geometrical arrangements. The mechanical framework that holds these modules together as a solar array is the only mission-unique design, changing in size and shape as required for each mission. There are several advantages to this approach. First, the typical solar array development cycle requires a mission unique design, procurement, and qualification including a custom qualification panel. With the modular architecture, a single qualification of the SMEX-Lite modules and the associated mechanical framework in a typical configuration provided a qualification by similarity to multiple missions. It then becomes possible to procure solar array modules in advance of mission definition and respond quickly and inexpensively to a selected mission's unique requirements. The solar array modular architecture allows the procurement of solar array modules before the array geometry has been frozen. This reduces the effect of procurement lead-time on the mission integration and test flow by as much as 50%. Second, by spreading the non-recurring costs over multiple missions, the cost per unit area is also reduced. In the case of the SMEX-Lite procurement, this reduction was by about one third of the cost per unit area compared to previous SMEX mission-unique procurements. Third, the modular architecture greatly facilitates the infusion of new solar cell technologies into flight programs as these technologies become available. New solar cell technologies need only be fabricated onto a standard-sized module to be incorporated into the next available mission. The modular solar array can be flown in a mixed configuration with some new and some standard cell technologies. Since each module has its own wiring terminals, the array can be arranged as desired electrically with little impact to cost and schedule. The solar array modular architecture does impose some additional constraints on systems and subsystem engineers. First, they must work with discrete solar array modules rather than size the array to fit exactly within an available envelope. The array area is constrained to an integer multiple of the module area. Second, the modular design is optimized for space radiation and thermal environments not greatly different from a typical SMEX LEO environment. For example, a mission with a highly elliptical orbit (e.g., Polar, SMEX/FAST) would require thicker coverglasses to protect the solar cells from the more intense radiation environment.

Lyons, John↗

Modeling and experimental assessment of a buried Leu–Ile mutation in dengue envelope domain III

Envelope protein domain III (ED3) of the dengue virus is important for both antibody binding and host cell interaction. Here, we focused on how a L387I mutation in the protein core could take place in DEN4 ED3, but cannot be accommodated in DEN3 ED3 without destabilizing its structure. To this end, we modeled a DEN4-L387I structure using the Penultimate Rotamer Library and taking the DEN4 ED3 main-chain as a fixed template. We found that three out of seven Ile{sup 387} conformers fit in DEN4 ED3 without introducing the severe atomic clashes that are observed when DEN3 serotype’s ED3 is used as a template. A more extensive search using 273 side-chain rotamers of the residues surrounding Ile{sup 387} confirmed this prediction. In order to assess the prediction, we determined the crystal structure of DEN4-L387I at 2 Å resolution. Ile{sup 387} indeed adopted one of the three predicted rotamers. Altogether, this study demonstrates that the effects of single mutations are to a large extent successfully predicted by systematically modeling the side-chain structures of the mutated as well as those of its surrounding residues using fixed main-chain structures and assessing inter-atomic steric clashes. More accurate and reliable predictions require considering sub-angstrom main-chain deformation, which remains a challenging task. - Highlights: • We mutated L387I of DEN4 ED3 and examined its effects on structure and stability. • We modeled the side-chain of Ile{sup 387} using DEN4 ED3's structure as a template. • We determined the crystal structure of DEN4-L387I and confirmed the modeling. • Side-chain repacking occurring around Ile{sup 387} involved >3 inter-connected residues. • These results explained why L387I mutation in DEN4 ED3 conserves thermostability.

60 APPLIED LIFE SCIENCES↗

Regional Analysis of Building Distributed Energy Costs and CO2 Abatement: A U.S. - China Comparison

The following paper conducts a regional analysis of the U.S. and Chinese buildings? potential for adopting Distributed Energy Resources (DER). The expected economics of DER in 2020-2025 is modeled for a commercial and a multi-family residential building in different climate zones. The optimal building energy economic performance is calculated using the Distributed Energy Resources Customer Adoption Model (DER CAM) which minimizes building energy costs for a typical reference year of operation. Several DER such as combined heat and power (CHP) units, photovoltaics, and battery storage are considered. The results indicate DER have economic and environmental competitiveness potential, especially for commercial buildings in hot and cold climates of both countries. In the U.S., the average expected energy cost savings in commercial buildings from DER CAM?s suggested investments is 17percent, while in Chinese buildings is 12percent. The electricity tariffs structure and prices along with the cost of natural gas, represent important factors in determining adoption of DER, more so than climate. High energy pricing spark spreads lead to increased economic attractiveness of DER. The average emissions reduction in commercial buildings is 19percent in the U.S. as a result of significant investments in PV, whereas in China, it is 20percent and driven by investments in CHP. Keywords: Building Modeling and Simulation, Distributed Energy Resources (DER), Energy Efficiency, Combined Heat and Power (CHP), CO2 emissions 1. Introduction The transition from a centralized and fossil-based energy paradigm towards the decentralization of energy supply and distribution has been a major subject of research over the past two decades. Various concerns have brought the traditional model into question; namely its environmental footprint, its structural inflexibility and inefficiency, and more recently, its inability to maintain acceptable reliability of supply. Under such a troubled setting, distributed energy resources (DER) comprising of small, modular, electrical renewable or fossil-based electricity generation units placed at or near the point of energy consumption, has gained much attention as a viable alternative or addition to the current energy system. In 2010, China consumed about 30percent of its primary energy in the buildings sector, leading the country to pay great attention to DER development and its applications in buildings. During the 11th Five Year Plan (FYP), China has implemented 371 renewable energy building demonstration projects, and 210 photovoltaics (PV) building integration projects. At the end of the 12th FYP, China is targeting renewable energy to provide 10percent of total building energy, and to save 30 metric tons of CO2 equivalents (mtce) of energy with building integrated renewables. China is also planning to implement one thousand natural gas-based distributed cogeneration demonstration projects with energy utilization rates over 70percent in the 12th FYP. All these policy targets require significant DER systems development for building applications. China?s fast urbanization makes building energy efficiency a crucial economic issue; however, only limited studies have been done that examine how to design and select suitable building energy technologies in its different regions. In the U.S., buildings consumed 40percent of the total primary energy in 2010 [1] and it is estimated that about 14 billion m2 of floor space of the existing building stock will be remodeled over the next 30 years. Most building?s renovation work has been on building envelope, lighting and HVAC systems. Although interest has emerged, less attention is being paid to DER for buildings. This context has created opportunities for research, development and progressive deployment of DER, due to its potential to combine the production of power and heat (CHP) near the point of consumption and delivering multiple benefits to customers, such as cost

25 ENERGY STORAGE↗