Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “method development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Development of Estimation Method for Radioactivity Concentration Distribution of Radioactive Wastes in a Box-shaped Container - 17034

We are developing a new estimation method suitable for determining radioactivity concentration distribution of radioactive wastes stored in a square box-shaped container. This method uses the Maximum A Posteriori (MAP) method which is a way to solve the inverse problem, and it estimates the radioactivity concentration distribution by comparing simulated data with measured data. In the measurement, gamma rays emitted from the radioactive wastes are measured by several gamma ray spectrometers which are set at different positions in relation to each other. On the other hand, the gamma ray spectrum data of each spectrometer are simulated by a Monte Carlo simulation code. The method uses an iterative calculation to solve the concentration distribution with measured spectrum data and simulated spectrum data. We conducted a simulation test to check the algorithm of our estimation method. And we also conducted an experiment using activated objects. We found that the concentration of the wastes in a box-shaped container could be estimated within a 20 % error for the simulation, and within a 40 % error for the experiment and we confirmed that feasibility of our method was favorable. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and Test of Collaring Methods for Nb$_3$SN Quadrupole Magnets

Fermilab is developing Nb 3 Sn quadrupole magnets for the planned upgrade of interaction regions of the Large Hadron Collider (LHC). Two distinctly different approaches have been employed, one using quadrupole‐symmetric and one using dipole‐symmetric collar laminations. This paper describes the design features of both collar types, collaring techniques for brittle Nb 3 Sn coils, and compares the advantages and disadvantages of the two approaches. Results of mechanical analysis for quadrupoles based on dipole‐type and quadrupole‐type collars are presented. Magnet construction issues and test results are reported. Test results include coil and component strain measurements during construction. Plans for the completion and test of the first dipole‐symmetric assembly are described.

Bossert, R.↗

Prediction of Redox Potentials for the Late Actinides Cm to Lr Using Electronic Structure Methods

Our previously developed computational method for calculating the aqueous redox potentials of the early actinides has been extended to the later elements in the actinide series: Cm, Bk, Cf, Es, Fm, Md, No, and Lr in multiple oxidation states. These calculations were performed using density functional theory with small-core pseudopotentials and their associated basis sets. Solvation effects were considered via a supermolecule-continuum approach, with 30 water molecules representing two solvation shells. Both the COSMO and SMD implicit solvation models were utilized. The structural parameters and hydration numbers for Cm(III), Bk(III), Bk(IV), and Cf(III) are in reasonable agreement with the available experimental data. For redox processes involving atomic cations in solution, the B3LYP/COSMO approach predicted redox potentials to within ±0.2 V of experiment for most redox couples, consistent with our prior work. Inclusion of spin-orbit corrections in specific redox pairs, especially those with the later actinides in high oxidation states, yields improved results relative to calculations including only scalar-relativistic corrections. The An +m /An(0) redox potentials were calculated using a Born-Haber cycle incorporating sublimation, ionization, and hydration energies. Due to a lack of experimental data, three sets of ionization energies were used for the Born-Haber cycle. The calculated An(III/0) potentials showed better agreement with experimental data when using the COSMO solvation model and the test set comprising the NIST recommended ionization energies. Furthermore, the Md(II/0) potential was better described with the SMD model, whereas No(II/0) was not well described by all methods. Finally, the computational approach was able to predict redox potentials that for most cases agreed with the current available experimental or estimated data.

Actinides↗

Renormalized effective actions in radially symmetric backgrounds: Exact calculations versus approximation methods

Our previously developed calculational method (the partial-wave cutoff method) is employed to evaluate explicitly scalar one-loop effective actions in a class of radially symmetric background gauge fields. Our method proves to be particularly effective when it is used in conjunction with a systematic WKB series for the large partial-wave contribution to the effective action. By comparing these numerically exact calculations against the predictions based on the large-mass expansion and derivative expansion, we discuss the validity ranges of the latter approximation methods.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Computerized quantitative evaluation of mammographic accreditation phantom images

Purpose: The objective was to develop and investigate an automated scoring scheme of the American College of Radiology (ACR) mammographic accreditation phantom (RMI 156, Middleton, WI) images. Methods: The developed method consisted of background subtraction, determination of region of interest, classification of fiber and mass objects by Mahalanobis distance, detection of specks by template matching, and rule-based scoring. Fifty-one phantom images were collected from 51 facilities for this study (one facility provided one image). A medical physicist and two radiologic technologists also scored the images. The human and computerized scores were compared. Results: In terms of meeting the ACR's criteria, the accuracies of the developed method for computerized evaluation of fiber, mass, and speck were 90%, 80%, and 98%, respectively. Contingency table analysis revealed significant association between observer and computer scores for microcalcifications (p<5%) but not for masses and fibers. Conclusions: The developed method may achieve a stable assessment of visibility for test objects in mammographic accreditation phantom image in whether the phantom image meets the ACR's criteria in the evaluation test, although there is room left for improvement in the approach for fiber and mass objects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Revealing Nanoscale Energy Flow Using Ultrafast THz to X-ray Beams (Final Technical Report)

We developed novel spectroscopic methods and made use of them to study energy flow and material properties on nanometer length scales and ultrafast time scales. Access to short length scales was provided through the use of light beams with short wavelengths (EUV through hard x-ray spectral ranges) and/or fabricated structural elements with nanometer dimensions. Recent advances in tabletop high harmonic generation of extreme ultraviolet (EUV) pulses were exploited to measure thermal transport and acoustic vibrations using time-resolved diffraction from photoexcited periodic nanostructures, revealing new physics that arises at length scales of tens to hundreds of nm. The tabletop EUV sources as well as the FERMI free electron laser at FERMI-Elettra in Trieste were used to generate as well as measure nanoscale thermoelastic responses without the need for patterned nanostructures, with the short length scale coming from optical interference patterns formed by crossing pairs of beams in transient grating experiments. We also used EUV and optical sources to excite and monitor ultrahigh-frequency acoustic waves (coherent phonons) at ultraflat interfaces and multilayer structures, extending our measurements of the highest-frequency coherent acoustic waves observed to date. Our measurements of acoustic properties allowed direct calculation of thermal conductivities which can be compared with our measurements of thermal transport and with first-principles calculations. Terahertz-frequency acoustic measurements can also be used to reveal complex relaxation dynamics in glass-forming liquids and partially disordered solids. Acoustic measurements were used to investigate the confinement effect in ultrathin liquid layers and to characterize mechanical properties of ultrathin solid layers. The methods we developed have broad fundamental applications and may also enable new practical metrology for use in nanoelectronics, just as earlier methods we developed have found commercial applications in microelectronics metrology.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Analysis of dynamics, stability, and flow fields' structure of an accelerated hydrodynamic discontinuity with interfacial mass flux by a general matrix method

We develop a general matrix method to analyze from a far field the dynamics of an accelerated interface between incompressible ideal fluids of different densities with interfacial mass flux and with negligible density variations and stratification. We rigorously solve the linearized boundary value problem for the dynamics conserving mass, momentum, and energy in the bulk and at the interface. We find a new hydrodynamic instability that develops only when the acceleration magnitude exceeds a threshold. This critical threshold value depends on the magnitudes of the steady velocities of the fluids, the ratio of their densities, and the wavelength of the initial perturbation. The flow has potential velocity fields in the fluid bulk and is shear-free at the interface. The interface stability is set by the interplay of inertia and gravity. For weak acceleration, inertial effects dominate, and the flow fields experience stable oscillations. For strong acceleration, gravity effects dominate, and the dynamics is unstable. For strong accelerations, this new hydrodynamic instability grows faster than accelerated Landau-Darrieus and Rayleigh-Taylor instabilities. For given values of the fluids' densities and their steady bulk velocities, and for a given magnitude of acceleration, we find the critical and maximum values of the initial perturbation wavelength at which this new instability can be stabilized and at which its growth is the fastest. The quantitative, qualitative, and formal properties of the accelerated conservative dynamics depart from those of accelerated Landau-Darrieus and Rayleigh-Taylor dynamics. New diagnostic benchmarks are identified for experiments and simulations of unstable interfaces.

Flow dynamics↗

A Poisson equation method for prescribing fully developed non-Newtonian inlet conditions for computational fluid dynamics simulations in models of arbitrary cross-section

Prescribing inlet boundary conditions for computational fluid dynamics (CFD) simulations of internal flow in complex geometries such as anatomical vascular models is challenging. In the absence of patient-specific inlet velocity data, a common approach for long blood vessels is to assume that the inlet flow is fully developed. In vessels of irregular cross section, however, prescribing fully developed conditions is complicated due to the lack of a general closed-form analytical solution. In this study, we develop a simple Poisson equation method for prescribing fully developed inlet conditions for the flow of either Newtonian or non-Newtonian fluids in CFD models of arbitrary cross-section. We first derive the generalized Poisson equation for fully developed flow of a non-Newtonian fluid and we then develop and verify a methodology for numerically computing the solution on any planar boundary domain. In addition, we develop a simple extension of the method for prescribing a non-orthogonal inlet velocity that represents fully developed flow from an upstream tube that is connected to the CFD inlet at a non-orthogonal angle. This may be used to investigate a common source of uncertainty in CFD simulations of internal flow that is due to a lack of information concerning the exact streamwise flow direction at the inlets. Comparison to several Newtonian and non-Newtonian benchmark verification solutions shows the method to be extremely accurate. As a practical demonstration case, we use the method to prescribe fully developed conditions on multiple non-circular inlets for the non-Newtonian flow of blood in a patient-specific model of the inferior vena cava (IVC). Finally, we further demonstrate the utility of the method by performing a sensitivity study using the patient-specific IVC model, wherein we investigate the influence of inlet velocity flow direction on the non-Newtonian IVC hemodynamics. Given its simplicity and computational efficiency, the method is shown to be far superior to alternative approaches for prescribing fully developed inlet conditions in such complicated geometries. In conclusion, to facilitate the adoption of our Poisson equation method, we have distributed our OpenFOAM source code and the associated test cases from this study as open-source software.

97 MATHEMATICS AND COMPUTING↗

Direct and precise measurement of displacement and velocity of flexible web in roll-to-roll manufacturing systems

Interest in the production of printed electronics using a roll-to-roll system has gradually increased due to its low mass-production costs and compatibility with flexible substrate. To improve the accuracy of roll-to-roll manufacturing systems, the movement of the web needs to be measured precisely in advance. In this paper, a novel measurement method is developed to measure the displacement and velocity of the web precisely and directly. The proposed algorithm is based on the traditional single field encoder principle, and the scale grating has been replaced with a printed grating on the web. Because a printed grating cannot be as accurate as a scale grating in a traditional encoder, there will inevitably be variations in pitch and line-width, and the motion of the web should be measured even though there are variations in pitch and line-width in the printed grating patterns. For this reason, the developed algorithm includes a precise method of estimating the variations in pitch. In addtion, a method of correcting the Lissajous curve is presented for precision phase interpolation to improve measurement accuracy by correcting Lissajous circle to unit circle. The performance of the developed method is evaluated by simulation and experiment. In the experiment, the displacement error was less than 2.5 μm and the velocity error of 1σ was about 0.25%, while the grating scale moved 30 mm.

36 MATERIALS SCIENCE↗

Development of the method for the preparation of Mg{sub 2}Si by SPS technique

The aim of the study was to develop a fast and simple method for preparation of polycrystalline Mg{sub 2}Si. For this purpose a Spark Plasma Sintering (SPS) method was used and synthesis conditions were adjusted in such a manner that no excess Mg was required. Materials were synthesized by the direct reaction of Mg and Si raw powders. To determine the phase and chemical composition, the fabricated samples were studied by X-ray diffraction and SEM microscopy coupled with EDX chemical analysis. Thermoelectric properties of samples (thermal conductivity, electrical conductivity and Seebeck coefficient) were measured all over temperature range of 300-650 K. The analysis by the scanning thermoelectric microprobe (STM) shows that samples have uniform distribution of Seebeck coefficient with mean value of about -405 {mu}VK{sup -1} and standard deviation of 94 {mu}VK{sup -1}. Prepared materials have intrinsic band gap of 0.45 eV and thermal conductivity {lambda}= 7.5 Wm{sup -1}K{sup -1} at room temperature.

36 MATERIALS SCIENCE↗

Development of an irradiation method with lateral modulation of SOBP width using a cone-type filter for carbon ion beams

Passive irradiation methods deliver an extra dose to normal tissues upstream of the target tumor, while in dynamic irradiation methods, interplay effects between dynamic beam delivery and target motion induced by breathing or respiration distort the dose distributions. To solve the problems of those two irradiation methods, the authors have developed a new method that laterally modulates the spread-out Bragg peak (SOBP) width. By reducing scanning in the depth direction, they expect to reduce the interplay effects. They have examined this new irradiation method experimentally. In this system, they used a cone-type filter that consisted of 400 cones in a grid of 20 cones by 20 cones. There were five kinds of cones with different SOBP widths arranged on the frame two dimensionally to realize lateral SOBP modulation. To reduce the number of steps of cones, they used a wheel-type filter to make minipeaks. The scanning intensity was modulated for each SOBP width with a pair of scanning magnets. In this experiment, a stepwise dose distribution and spherical dose distribution of 60 mm in diameter were formed. The nonflatness of the stepwise dose distribution was 5.7% and that of the spherical dose distribution was 3.8%. A 2 mm misalignment of the cone-type filter resulted in a nonflatness of more than 5%. Lateral SOBP modulation with a cone-type filter and a scanned carbon ion beam successfully formed conformal dose distribution with nonflatness of 3.8% for the spherical case. The cone-type filter had to be set to within 1 mm accuracy to maintain nonflatness within 5%. This method will be useful to treat targets moving during breathing and targets in proximity to important organs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Progress toward the development and testing of source reconstruction methods for NIF neutron imaging

Development of analysis techniques for neutron imaging at the National Ignition Facility is an important and difficult task for the detailed understanding of high-neutron yield inertial confinement fusion implosions. Once developed, these methods must provide accurate images of the hot and cold fuels so that information about the implosion, such as symmetry and areal density, can be extracted. One method under development involves the numerical inversion of the pinhole image using knowledge of neutron transport through the pinhole aperture from Monte Carlo simulations. In this article we present results of source reconstructions based on simulated images that test the methods effectiveness with regard to pinhole misalignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Decoupling Internalization, Acidification and Phagosmal-Endosomal/Iysosomal Phagocytosis of Internalin A coated Beads in epithelial cells

Phagocytosis has been extensively examined in 'professional' phagocytic cells using pH sensitive dyes. However, in many of the previous studies, a separation between the end of internalization, beginning of acidification and completion of phagosomal-endosomal/lysosomal fusion was not clearly established, and in several cases, it was treated as a one-step process. In addition, very little work has been done to systematically examine phagosomal maturation in 'non-professional' phagocytic cells, such as epithelial cells. Therefore, in this study, we developed a simple and novel method to decouple and accurately measure particle internalization, phagosomal acidification and phagosomal-endosomal/lysosomal fusion in Madin-Darby Canine Kidney (MDCK) and Caco-2 epithelial cells. Our method was developed using a pathogen mimetic system consisting of polystyrene beads coated with Internalin A (InlA), a membrane surface protein from Listeria monocytogenes known to trigger receptor-mediated internalization. We achieved independent measurements of the rates of internalization, phagosomal acidification and phagosomal-endosomal/lysosomal fusion in epithelial cells by combining the InlA-coated beads (InlA-beads) with antibody quenching, pH sensitive dyes and endosomal/lysosomal dyes, as follows: the rate of InlA bead internalization was measured via antibody quenching of a pH independent dye (Alexa488) conjugated to InlA-beads, the rate at which phagosomes containing internalized InlA beads became acidified was measured using a pH dependent dye (FITC) conjugated to the beads and the rate of phagosomal-endosomal/lysosomal fusion was measured using a combination of unlabeled InlA-beads and an endosomal/lysosomal dye. By performing these independent measurements under identical experimental conditions, we were able to decouple the three processes and establish time scales for each. In a separate set of experiments, we also exploited the phagosomal acidification process to demonstrate an additional, real31 time method for tracking bead binding, internalization and phagosomal acidification in both MDCK and Caco-2 cells, as well as 1 NIH 3T3 fibroblast cells, using FITC conjugated to InlA-beads or fibronectin-coated beads. Using this method, we found that the time scales for internalization, phagosomal acidification and phagosomal-endosomal/lysosomal fusion were 23-32 min, 3-4 min and 74-120 min, respectively, for epithelial cells, MDCK and Caco-2, which are slower than the kinetics observed in professional phagocytes such as macrophages. Both the static and real-time methods developed here are expected to be readily and broadly applicable, as they simply require conjugation of a fluorophore to a pathogen or mimetic of interest in combination with common cell labeling dyes, and are not limited to the InlA ligand or cell types used here. As such, these methods hold promise for future measurements of receptor-mediated internalization in other cell systems, e.g. other pathogen-host systems.

59 BASIC BIOLOGICAL SCIENCES↗

Development of new methods for studying nanostructures using neutron scattering

The goal of this project was to develop improved instrumentation for studying the microscopic structures of materials using neutron scattering. Neutron scattering has a number of advantages for studying material structure but suffers from the well-known disadvantage that neutrons’ ability to resolve structural details is usually limited by the strength of available neutron sources. We aimed to overcome this disadvantage using a new experimental technique, called Spin Echo Scattering Angle Encoding (SESAME) that makes use of the neutron’s magnetism. Our goal was to show that this innovation will allow the country to make better use of the significant investment it has recently made in a new neutron source at Oak Ridge National Laboratory (ORNL) and will lead to increases in scientific knowledge that contribute to the Nation’s technological infrastructure and ability to develop advanced materials and technologies. We were successful in demonstrating the technical effectiveness of the new method and established a baseline of knowledge that has allowed ORNL to start a project to implement the method on one of its neutron beam lines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Method for Measurement of Photonuclear-Reaction Cross Sections with the Aid of Simulated Quasimonoenergetic-Photon Spectra

A procedure for measuring photonuclear-reaction cross sections by employing the method of quasimonochromatization of the bremsstrahlung photon spectrum is developed. This procedure permits determining reaction cross sections via measuring the reaction yield at three fixed values of the electron energy. The procedure is equivalent to measuring the cross section in question for quasimonochromatic photons. Bremsstrahlung-photon spectra are obtained using state-of-the-art simulation means involving the GEANT4 code as applied to a specific experiment with allowance for its geometry, target thicknesses, electron-beam parameters, etc. The results obtained by simulating quasimonochromatic distributions of bremsstrahlung photons are presented for experiments at the LUE-8-5 linear electron accelerator of Institute for Nuclear Research (Moscow, Russian Academy of Sciences). These results are found to be in good agreement with the experimental energy distribution of the cross section for the reaction {sup 111}Cd(γ, γ') in the energy range between 5 and 8 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nonequilibrium solvent effects in Born-Oppenheimer molecular dynamics for ground and excited electronic states

The effects of solvent on molecular processes such as excited state relaxation and photochemical reaction often occurs in a nonequilibrium regime. Dynamic processes such as these can be simulated using excited state molecular dynamics. In this work, we describe methods of simulating nonequilibrium solvent effects in excited state molecular dynamics using linear-response time-dependent density functional theory and apparent surface charge methods. These developments include a propagation method for solvent degrees of freedom and analytical energy gradients for the calculation of forces. Molecular dynamics of acetaldehyde in water or acetonitrile are demonstrated where the solute-solvent system is out of equilibrium due to photoexcitation and emission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mercury speciation using microcolumns with a direct mercury analyzer (DMA). Development of analytical method for the Savannah River Site liquid system

Mercury in the Savannah River Site (SRS) Liquid Waste System (LWS) exists in various forms, including: a) ionic inorganic mercury, organomercury (e.g., methyl Hg), and other less abundant species dissolved in LWS fluids, b) mercury solids such as oxides, hydroxides, amalgams, sulfides, and sorbed mercury, c) accumulations of dense liquid elemental mercury, and d) vapor phase elemental and organomercury mercury in tank headspace gas and in evaporators. Strategic and proactive management of the estimated 60,000 Kg mercury in the LWS requires deployment of efficient and effective paradigms for sampling and analysis of the total quantity of mercury in the various physical-chemical forms. Scoping tests of selective gas-phase sorbents for mercury speciation were performed to support LWS objectives. This research specifically focused on developing and testing streamlined methods to obtain high-quality analytical results for gaseous mercury species. The proposed methods are straightforward, using small columns (microcolumns) filled with materials that selectively sorb one or more target forms of mercury. Simple differentiation of mercury species and quantification is then achieved using an efficient thermal-desorption-based total mercury analyzer as the final step. Benefits associated with transitioning from multistep procedures such as EPA Methods 245.1, 1630 and 1631to streamlined microcolumn approaches include reduced analysis time, labor, and waste generation. Such transitioning would maximize the value of the current deployment of direct mercury analysis (EPA Method 7473) at SRS. This work has two target end uses: 1) simplifying the analysis steps and reducing costs for liquid samples (e.g., developing a total organic mercury (TOM) method), and 2) providing options for high-quality onsite analysis and rapid turnaround for gas samples in support of SRS LWS industrial hygiene (IH) objectives.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial Development of a Method to Measure Carbon by Thermogravimetric Analysis-Mass Spectrometry

During HB-Line flowsheet development efforts at the Savannah River National Laboratory (SRNL), plutonium oxide (PuO 2 ) samples were produced using different precipitation and calcination conditions. To evaluate a potential cost savings for future analyses, this study measured the carbon (C) content of ten SRNL PuO 2 samples by two different methods: the accepted method of a carbon/sulfur (C/S) analyzer and a potential method of thermogravimetric analysis-mass spectrometry (TGA-MS). Though PuO 2 produced by HB-Line was not used in this study, the AFS-2 PuO 2 campaign is currently using TGA-MS for moisture analysis. Thus, using the same TGA-MS analysis for C could potentially provide a cost savings.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗