The Neutron Scattering Cross Section and Angular Distribution Measurement Program at LANL
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The Surrogate nuclear reactions method, an indirect approach for determining cross sections for compound-nuclear reactions involving difficult-to-produce targets, is reviewed. The underlying formalism is outlined, the challenges involved in carrying out a complete Surrogate treatment are detailed, and the present status of the theory is summarized. The approximations employed in the analyses of Surrogate experiments are discussed and their validity is examined.
A streaked radiography diagnostic has been proposed as a technique to determine the ablator mass remaining in an inertial confinement fusion ignition capsule at peak velocity. This instrument, the 'HXRI-5', has been designed to fit within a National Ignition Facility Diagnostic Instrument Manipulator. The HXRI-5 will be built at Sandia National Laboratories (SNL), and initial testing will be done at the SNL Z-Beamlet Facility. In this paper, we will describe the National Ignition Campaign requirements for this diagnostic, the instrument design, and the planned test experiments.
The detection of neutrons in fast-ignitor experiments or down-scattered neutrons in inertial fusion experiments is very challenging since it requires the neutron detection system to recover within 10–100 ns from a high background orders of magnitude stronger than the signal of interest. The background is either the hard x-ray emission from short-pulse laser target interactions for the fast-ignitor experiments or the primary neutron signal for the down-scattered neutrons. A liquid-scintillator detector has been developed using a gated photomultiplier that suppresses the background signal and eliminates the afterglow present in conventional plastic scintillators.
Photoconductive atomic force microscopy is used to investigate nanoscale incident photon-to-current efficiency spectra of polymer bulk heterojunction solar cells based on poly[2-methoxy-5-(3,7-dimethyloctyloxy)]-1,4-phenylenevinylene (MDMO-PPV) and [6,6]-phenyl-C 71 -butyric acid methyl ester (PC 71 BM) . Nanoscale external quantum efficiency reveals the complex morphology of MDMO-PPV:PC 71 BM films cast from toluene solution. Not only electron transfer from the photoexcited donor to the fullerene but also hole transfer process from photoexcited fullerene to the donor phase due to highest occupied molecular orbital offset is observed. The difference in performance between toluene and chlorobenzene-cast devices is explained by the variation in relative contributions from two charge transfer mechanisms.
The relativistic electron transport induced by an ultraintense picosecond laser is experimentally investigated using an x-ray two-dimensional imaging system. Previous studies of the electron beam divergence [R. B. Stephens et al. Phys. Rev. E 69, 066414 (2004), for instance] were based on an x-ray imaging of a fluorescence layer buried at different depths in the target along the propagation axis. This technique required several shots to be able to deduce the divergence of the beam. Other experiments produced single-shot images in a one-dimensional geometry. The present paper describes a new target design producing a single-shot, two-dimensional image of the electrons propagating in the target. Several characteristics of the electron beam are extracted and discussed and Monte Carlo simulations provide a good understanding of the observed beam shape. The proposed design has proven to be efficient, reliable, and promising for further similar studies.
Untangling the roles of different plasma formation mechanisms in high-current electrical discharges requires controlling each mechanism and isolating its effects. Recent experiments use this method to find that thermal formation of plasma occurs from 6061-alloy Al conductors by ohmic heating when the surface field reaches a magnetic field threshold of 2.2 MG (independently of {partial_derivative}B/{partial_derivative}t ranging from 30 to 80 MG/{mu}s) [T. J. Awe et al., Phys. Rev. Lett. 104, 035001 (2010)]. The experiments pulse 1.0 MA peak current on the surface of thick ({approx}1.0 mm diameter) aluminum rods in 100 ns. Strong electric fields are necessarily introduced, and precursor plasma may form (e.g., from arcing electrical contacts). To ensure plasma formation is predominantly thermal, a systematic study of multiple combinations of high-current electrodes and central-rod profiles was completed. Data from multiple diagnostics show that the time and location of plasma formation strongly correlate with the hardware combination used. An extensive dataset (greater than 100 shots) enabled numerous hypotheses to be tested regarding plasma formation mechanisms. For hardware with compressed, large-diameter current joints, plasma formation is a predominantly thermal process driven by ohmic heating.
Explore the source record for details and available documents.
Abstract not provided.
Recent data on the EMC effect from Jefferson Lab experiment E03103 suggest that the nuclear dependence of the high x quark distribution may depend on the local nuclear environment, rather than being a purely bulk effect. We briefly discuss the analysis and results of the E03103 experiment focusing on the light nuclei and high x region. In addition, we also discuss a future experiment at the upgraded 12 GeV Jefferson Lab facility which will further investigate the role of the local nuclear environment and the influence of detailed nuclear structure on the modification of quark distributions.
A microfabricated amorphous silicon nitride membrane-based nanocalorimeter is proposed to be suitable for an x-ray transparent sample platform with low power heating and built-in temperature sensing. In this work, thermal characterization in both air and vacuum are analyzed experimentally and via simulation. Infrared microscopy and thermoreflectance microscopy are used for thermal imaging of the sample area in air. While a reasonably large isothermal area is found on the sample area, the temperature homogeneity of the entire sample area is low, limiting use of the device as a heater stage in air or other gases. A simulation model that includes conduction, as well as radiation and convection heat loss, is presented with radiation and convection parameters determined experimentally. Simulated temperature distributions show that the homogeneity can be improved by using a thicker thermal conduction layer or reducing the pressure of the gas in the environment but neither are good solutions for the proposed use. A new simple design that has improved temperature homogeneity and a larger isothermal area while maintaining a thin thermal conduction layer is proposed and fabricated. This new design enables applications in transmission x-ray microscopes and spectroscopy setups at atmospheric pressure.
The Dante is a 15 channel filtered diode array which is installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The system yields the spectrally and temporally resolved radiation flux from 50 eV to 10 keV from various targets (i.e., Hohlraum, gas pipes, etc.). The absolute flux is determined from the radiometric calibration of the x-ray diodes, filters, and mirrors and an unfold algorithm applied to the recorded voltages from each channel. The unfold algorithm assumes an emitting source that is spatially uniform and has a constant area as a function of photon energy. The emitting x-ray source is usually considered to be the laser entrance hole (LEH) of a given diameter for Hohlraum type targets or the effective wall area of high conversion efficiency K-shell type targets. This assumption can be problematic for several reasons. High intensity regions or 'hot spots' in the x-ray are observed where the drive laser beams strike the target. The 'hot spots' create non-uniform emission seen by the Dante. Additionally, thinned walled (50 {mu}m) low-Z targets (C{sub 22}H{sub 10}N{sub 2}O{sub 5}) have an energy dependent source size since the target's walls will be fully opaque for low energies (E < 2-3 keV) yet fully transmissive at higher energies. Determining accurate yields can be challenging for these types of targets. Discussion and some analysis will be presented.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.